• Title/Summary/Keyword: angled

Search Result 298, Processing Time 0.022 seconds

Indirect calculation for volume of packed red cell(VPRC) by means of erythrocyte sedimentation rate(ESR) of diluted blood in dogs (개 회석혈의 적혈구침강율(ESR)에 의한 적혈구 침층용적(VPRC)치의 간접계산법)

  • Lee, Bang-whan;Park, Young-jun
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.2
    • /
    • pp.41-49
    • /
    • 1989
  • The study was undertaken to obtain indirect values of volume of packed red cell (VPRC) without centrifugation, using the erythrocyte sedimentation rate (ESR) of diluted blood in dogs. ESRs of diluted blood using the diluent of autologous plasma in which formed numerous RBC-rouleau clumps, autologous serum in which formed a few RBC-rouleau clumps, and 5% dextrose or 6% sucrose solutions in which formed numerous RBC-aggregation clumps, were accelerated. But, ESR of diluted blood using the 0.9% saline, D-S, ACD-B, CDP or D-PBS solutions were sluggish, because erythrocytes were dispersed in these diluents. Reliable values of VPRC on the basis of the correlating regressive equation to the ESR could be derived from values of$60^{\circ}$-angled-micro-ESR/40 min in the mixture, four parts of 5% dextrose solution and one part of whole blood. In the ESR values of diluted blood with low ratio, 1:1~3:1, $60^{\circ}$-micro-ESR was higher than $60^{\circ}$-Wintrobe-ESR. But, in the diluted blood with high ratio, 4:1~5:1, there was no different ESR values. For an aid of practical use, authers suggested a list of the $60^{\circ}$-micro-ESR/40 min in the diluted blood with equivalent VPRC of whole blood.

  • PDF

Indirect calculation for volume of packed red cell(VPRC) by means of erythrocyte sedimentation rate (ESR) of blood diluted with isotonic dextrose solution in cattle (소에 있어서 등장 dextrose액으로 희석한 혈액의 적혈구 침강율(ESR) 측정에 의한 적혈구 침층용적(VPRC)치의 간접계산법)

  • Lee, Bang-whan;Bahk, Young-woo;Min, Byeong-man
    • Korean Journal of Veterinary Research
    • /
    • v.30 no.1
    • /
    • pp.107-112
    • /
    • 1990
  • The purpose of this study is to derive indirect values of volume of packed red cell(VPRC), without centrifugation, from erythrocyte sedimentation rate(ESR) of blood diluted with isotonic dextrose solution in cattle. Each of ten blood samples taken from apprently healthy Korean cows and Holstein cows was used to produce eight different mixture of autologous plasma and blood corpuscles such that their values of VPRC lay between 15 to 50ml/100ml, and then each of the blood mixture was again diluted with 5% dextrose solution. The measurements of ESR using 45 degree-angled capillary hematocrit tube, 1.1~1.2mm bore, ($45^{\circ}$-micro-ESR) were practised for the diluted blood of various levels of VPRC under the ambient temperature of $10^{\circ}$, $20^{\circ}$ and $30^{\circ}C$. Reliable values of VPRC on the basis of the correlating linear regressive equation to the ESR could be derived from the values of $45^{\circ}$-micro-ESR/hr in the mixture of one part of whole blood and one part of 5% dextrose solution(1:1). For an aid of practical use, authors suggested a list of the $45^{\circ}$-micro-ESR/hr values of the diluted blood equivalent to VPRC of whole blood.

  • PDF

Design of Triangular-Patch Type Low Pass Filter (삼각패치형 저역 통과 여파기의 구현)

  • Oh, Song-Yi;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.355-360
    • /
    • 2012
  • In this paper, an stepped-impedance low pass filter(SI-LPF) of triangular-patch type is proposed. A SI-LPF designed according to the standard SI-LPF design procedure is folded as a right angled triangle. The figure of merits of this structure are the adjustabilities of the cut off frequency, the stopband and the attenuation pole frequency of the proposed LPF by varying the resultant slots after folding the SI-LPF compactly for miniaturization. The size of the fabricated LPF is $13.75mm{\times}6.875mm$, which is 24.4 % reduced one compared to that of the conventional SI-LPF. The measured results of the LPF show return loss of less than -10 dB at passband, insertion loss of less than -10 dB at stopband and wide stopband from 3.5 GHz to 10 GHz (about $3f_c$).

Development of Electronic Opening and Shutting Device for One-Ton Wing-Body Truck

  • Han, Jong-Soo;Seo, Chang-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.565-569
    • /
    • 2004
  • The wing-body trucks are special vehicles that are designed to provide large carrying space and to protect the freights from outside impacts and bad weather. They are constructed to the structure opening and shutting three-layered aluminum top. In the middle- and large-size(above one-ton) wing-body trucks, wing-body is opened/closed by opening and shutting device of oil pressure type. But one-ton truck is constructed that its wing-body is opened/closed in manual to use helping of stay-dampers. So, we developed an electronic opening and shutting device for one-ton wing-body trucks to improve the inconvenience of usage for manually operated wing-body. The developed device is consisted of two connected links and a dc motor combined with an worm gear. The worm gear changes the rotation axis of the dc motor to a right-angled direction and transfers the torque of dc motor to the links. The two connected links open/shut the wing-body using the torque transferred from the dc motor. When the wing-body starts to be opened, the biggest torque is required from the dc motor for opening the wing-body. And as the wing-body is opened more and more, the required torque is smaller for opening the wing-body. Thus, the structure of two connected links are designed to locate at the center of worm gear so that maximum torque of the dc motor is transferred the links at the initial time starting to open wing-body. The controller of the device with open and closed buttons also is designed to protect the device from over-opening and over shutting operations. The developed device is accomplished for many experiments using actual vehicle. Those experiments show that the device has more excellent performance than the oil pressure type.

  • PDF

Resistivity Survey on Stylobate of Five-story Stone Pagoda in Tamni-ri, Uiseong (의성 탑리리 오층석탑 기단부 전기비저항 탐사)

  • Oh, Hyundok;Kwon, Moonhee
    • Geophysics and Geophysical Exploration
    • /
    • v.23 no.4
    • /
    • pp.253-260
    • /
    • 2020
  • The five-story stone pagoda in Tamni-ri located in Uiseong County in Gyeongsangbuk-do had an unstable upper structure, and the structural deformation of the foundation stone and the stylobate was severe. In order to repair the base of the pagoda, it must be confirmed if there are support stones inside the base. Resistivity survey was performed to study the inner base stone structure during the repair work. The stylobate was exposed soil and broken stones after removing the walls and the cover of the stylobate. Modified pole-dipole array II was used for the resistivity survey, and compared with the typical pole-dipole array method. And in this study, a physical scale-down model experiment was performed to compare and analyze distortions caused by severe topographical undulations such as right-angled lines. The results show that the stylobate of Five-story Stone Pagoda in Tamni-ri Uiseong has base stones inside the reinforced filling soil and are located beneath the pillar of the body and supporting the pagoda.

Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow (초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 요철이 설치된 유출면에서의 열/물질전달 특성)

  • Rhee, Dong-Ho;Nam, Yong-Woo;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.338-348
    • /
    • 2004
  • The present study is conducted to investigate the effect of rib arrangements on an impingement/effusion cooling system with initial crossflow. To simulate the impingement/effusion cooling system, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of tile hole diameter. Initial crossflow passes between the injection and effusion plates, and the square ribs (3mm) are installed on the effusion plate. Both the injection and effusion hole diameters are 10mmand Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effects of rib arrangements, various rib arrangements, such as 90$^{\circ}$transverse and 45$^{\circ}$angled rib arrangements, are used. Also, the effects of flow rate ratio of crossflow to impinging jets are investigated. With the initial crossflow, locally low transfer regions are formed because the wall jets are swept away, and level of heat transfer rate get decreased with increasing flow rate of crossflow. When the ribs are installed on the effusion plate, the local distributions of heat/mass transfer coefficients around the effusion holes are changed. The local heat/mass transfer around the stagnation regions and the effusion holes are affected by the rib positions, angle of attack and rib spacing. For low blowing ratio, the ribs have adverse effects on heat/mass transfer, but for higher blowing ratios, higher and more uniform heat transfer coefficient distributions are obtained than the case without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. Average heat transfer coefficients with rib turbulators are approximately 10% higher than that without ribs, and the higher values are obtained with small pitch of ribs. However, the attack angle of the rib has little influence on the average heat/mass transfer.

A Study of Costume Types and background of Occurence in the Era of Renaissance (르네상수시대의 복식 유형과 그발생배경에 관한연구)

  • 이순홍
    • Journal of the Korean Society of Costume
    • /
    • v.30
    • /
    • pp.275-294
    • /
    • 1996
  • In fashion there was a move away from the ascetic of the Gothic according to the appear-ance of a new spirit at the beginning of the fourteenth centuries initially in Italy. The new spirit Humanism applied their interest not to the universal but to the individual and particular. The Renaissace costume style based on the Humanism was sharp angled and curvy and had a grotesque silhouette with the exaggerated and tense decorations. The purpose of this study is researching the background led to the balanced costume style characterized by unique details. out of the tastte for luxury and beauty grew a new style known as slashing in which seams were left open and colored linigs thrust through or cuts were made in an entire cos-tume and contrasting material puffed out of the cuts. With the slashes another element was characterized in the high Renaissance cos-tume style that was the use of points or lace to hold a costume together. For the masculint costumes pads became into a fashion and were used for forming the antinatural artificial and bulky silhouettes. The body was distorted and tensed by putting the pads into the sleeves and bodice. The jacket with a full rounded bodice like a bow known as peascod belly and haut de chausses a onion-shaped trunk hose with a codipiece ap-peared and grew one of the most characteristic of Renaissance style. According to these sociological changes the view of the beauty based on the human body and in both of men and women the costume style was changed very much to emphasixed their physical beauty and finally it grew a grotesque style and even more a exposed style that exposed a part of their body. Those backgrounds as were stated above can be said to lead to the appearance of the grotesque style in the Renaissance Age.

  • PDF

Study on the Conventional Tomographic Findings for the Patients with Temporomandibular Disorders (턱관절장애환자의 일반단층촬영 소견에 관한 연구)

  • Seo, Seong-Jong;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.3
    • /
    • pp.277-290
    • /
    • 2001
  • 영상촬영술은 개방형 외과적 관절수술이나 관절경 검사법을 할 수 없는 상태에서 관절의 상태에 대한 시각적 정보를 확보할 수 있는 유일한 방법이다. 이것의 주된 목적은 진단과 치료계획과정을 도와주는 정보를 제공하는데 있다. 그중 방사선 촬영술은 턱관절의 구조적 질병을 진단하는데 기본적인 수단으로서 오래동안 사용되어 왔 다. 그러나 어떠한 방사선 소견이 개별 관절질환의 특징적 소견인지는 찾아내기가 어려운 실정이다. 그러나 통상적 턱관절 방사선 촬영술로서도 구조적 골변화를 찾아낼 수 있으며 특히 시상 단층촬영술은 턱관절에서 가장 유익한 정보를 보여준다고 한다. 또한 보고에 의하면 턱관절 장애는 다양한 해부학적 요인들과 관련이 있다고 한다. 따라서 본 연구에서는 통상적인 방사선 단층촬영술을 이용하여 턱관절 장애환자의 턱관절에서 나타나는 골변화를 찾아내고 이러한 골변화가 하악과두 수평각, 하악과두 형태, 과두위치 등과 같은 여러 요인들과 서로 관련이 있는 지 찾아보고저 하였다. 단국치대 구강내과 안면동통진료실에 내원한 256명의 환자 중, 턱관절장애를 편측으로만 호소하는 환자 73명을 대상으로 SCANORA를 이용하여 방사선 단층촬영을 시행하였다. 먼저 악하두정위 촬영을 통해 정중선에 대한 하악과두의 방향을 찾아내고 단층촬영 부위를 계산하였으며, 모든 촬영면은 4 mm 두께로 하고 턱관절 부위에만 국한되도록 조준하였다. 폐구 시 4개의 시상 촬영과 개구 시 한개의 시상 및 전두촬영상을 구한 후, 하악과두, 과두 형태 및 하악과두위치 등과 같은 요인들에 대한 골변화간의 관련성을 조사하고저 자료를 측정한 후 Contengency table analyses를 시행하였다. 본 연구의 결과에 따르면 결론적으로 하악과두의 형태, 하악과두의 수평각 및 하악과두의 위치 등은 턱관절의 골변화와 상호 관련이 있다는 가설을 확인할 수 있었다. 즉 하악과두상의 골변화는 과두가 후방위치되고 과두각이 25도 이상 크며, 특히 20대에서는 flat type, 40대에서는 angled type의 과두형태를 가지며 두 과두각의 차이가 9도에서 12도 정도로 큰 차이가 있는 남성환자에서 증가한다.

  • PDF

Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study

  • Elsyad, Moustafa Abdou;Setta, Fathi Abo;Khirallah, Ahmed Samir
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.116-124
    • /
    • 2016
  • PURPOSE. The aim of the present study was to evaluate, by means of strain gauge analysis, the effect of different implant angulations on strains around two implants retaining mandibular overdenture with Locator attachments. MATERIALS AND METHODS. Four duplicate mandibular acrylic models were constructed. Two implants were inserted in the canine regions using the following degrees of distal inclinations: group I (control); $0^{\circ}$, group II; $10^{\circ}$, group III; $20^{\circ}$, and group IV; $30^{\circ}$. Locator pink attachments were used to connect the overdenture to the implants and Locator red (designed for severely angled implants) was used for group IV (group $IV_{red}$). For each group, two linear strain gauges were attached at the mesial and distal surfaces of the acrylic resin around each implant. Peri-implant strain was measured on loading and non-loading sides during bilateral and unilateral loading. RESULTS. For all groups, the mesial surfaces of the implants at loading and non-loading sides experienced compressive (negative) strains, while the distal implant surfaces showed tensile (positive) strains. Group IV showed the highest strain, followed by group III, group II. Both group I and group $IV_{red}$ showed the lowest strain. The strain gauges at the mesial surface of the loading side recorded the highest strain, and the distal surface at non-loading side showed the lowest strain. Unilateral loading recorded significantly higher strain than bilateral loading. CONCLUSION. Peri-implant strains around two implants used to retain mandibular overdentures with Locator attachments increase as distal implant inclination increases, except when red nylon inserts were used.

Numerical Study of the Rib Arrangements for Enhancing Heat Transfer in a Two-pass Channel of Large Aspect Ratio (종횡비가 큰 이차유로에서 냉각성능 향상을 위한 요철배열 연구)

  • Han, Sol;Choi, Seok Min;Sohn, Ho-Seong;Cho, Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.161-169
    • /
    • 2017
  • The present study investigated the effect of the rib arrangement and a guide vane for enhancing internal cooling of the blade. Two types of rib arrangements were used in the first and second passage in parallel. Aspect ratio of the channel was 5 and a fixed Reynolds number based on hydraulic diameter was 10,000. The attack angle of rib was $60^{\circ}$, rib pitch-to-height ratio (p/e) was 10, and the rib height-to-hydraulic-diameter ratio ($e/D_h$) was 0.075. The effect of an interaction between Dean vortices and the secondary vortices from the first passage was observed. Overall, the attack angle of rib in the first passage was dominant factor to heat transfer and flow patterns in turning region. Also, the channel with a guide vane showed enhanced heat transfer at the tip surface with reducing flow separation and recirculation.