• Title/Summary/Keyword: angle of incidence

Search Result 583, Processing Time 0.026 seconds

Wind Tunnel Test of Floating Offshore Structure (해양부유 구조물의 풍동실험)

  • 이동환;신현경;김기은
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.125-137
    • /
    • 1996
  • Experimental wind tunnel tests have been attempted to investigate the aerodynamic characteristics of floating offshore structure using some types of scaled mldels. The static behaviors of lift, drag forces and pitching moment of its models are measured to exammine the relationship between wind loads and incidence angle, wind velocity, shape of models. The effect of solid ground has been obtained also.

  • PDF

Wave Screening Effectiveness of Infilled Trenches (방진벽의 표면가 산란효과)

  • 이종세
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.152-159
    • /
    • 1997
  • An analytical method is developed to study the propagation of surface waves across infilled trenches. The Green's function technique is used to estimate the reflection and transmission coefficients of Rayleigh waves across a semi-infinite plate inserted between two homogeneous quarter-spaces. After validating the method against experimental data, influence of the material contrast and the angle of incidence on the screening effectiveness of an infilled trench is examined.

  • PDF

Analysis of ultrasonic signals through media in transformer (변압기의 전달 매질에 따른 초음파 신호의 특성 분석)

  • Chin, Sang-Bum;Park, Hyun-Soo;Shin, Dong-Seok;Kwak, Hee-Ro;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2057-2059
    • /
    • 1999
  • This paper describes the phenomena of the refraction and reflection when the ultrasonic signals generated by PD(Partial Discharge) in a transformer propagate through the boundary between insulating oil and the tank of the transformer. In this paper, considering the characteristic of the ultrasonic signal and the velocity of the propagation in medium, propagation time from PD source to sensor for incidence angle was calculated. As a result, it was found that the shortest time at specific angle exists. Taking into account the velocity of the propagation in medium, the shortest time with a computer was simulated. It was shown that the simulation was same as experimental result at a real PD source in the transformer.

  • PDF

NUMERICAL STUDY OF FLOW PATTERNS PAST AN INCLINED SQUARE CYLINDER (기울어진 정방형 실린더를 지나는 유동패턴의 수치해석적 연구)

  • Yoon, Dong-Hyeog;Yang, Kyung-Soo;Choi, Choon-Bum
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.19-24
    • /
    • 2009
  • A parametric study has been carried out to elucidate the characteristics of flow past a square cylinder inclined with respect to the main flow for Re$\leq$150. Reynolds number and angle of incidence are the key parameters which determine the flow characteristics. This study would be the first step towards understanding flow pattern past a cylindrical structure under a strong gust of wind from the viewpoint of wind hazards. A complete classification of flow pattern has been obtained in the laminar region.

The Relationship between Foot Arch Structure and March Fractures - Comparative study between 15(30feet) normal person and the 15(30feet) patients with march fracture - (행군골절 발생과 발아치 구조의 연관성에 대한 연구보고)

  • Bae, Young-Jae;Yoon, Sung-Il
    • Journal of Korean Foot and Ankle Society
    • /
    • v.2 no.2
    • /
    • pp.71-75
    • /
    • 1998
  • The fact that, under similar training activities performed in the same environment, march fractures develop in only a certain percentage of the trainees indicates that intrinsic factors are affecting the prevalence of these fractures. Among these intrinsic factors, the relation between foot arch type and the occurance of march fractures was investigated in this study. From 1997 to 1998, at one infantry medical company of infantry corps in Korea, 15 march fracture patients were detected among infantry soldiers. Quantitative measures of the foot arch (longitudinal) structure of 15(30feet) march fracture patients were established and compared with those of 15(30feet) normal person. The results were as follows. 1. From the lateral X-ray film, three parameters (i.e. calcaneal angle, forefoot angle, height to length ratio)were defined to describe the structure of the longitudinal arch of the foot. 2. The mean value of the calcaneal angle of march fracture group and normal control group showed 16.4 degree, 20.5 degree respectively. The difference between two groups was statistically significant (P>0.006), but those of forefoot angle and height to length ratio were not. 3. In the calcaneal angle twenty-six feet(87%) of march fracture group were lower than 17 degrees but twenty-five feet(83%) of normal control group were more than 17 degrees. That is, march fracture were more prevalent in feet with low calcaneal angle. 4. In the low arch foot, the orthotic device might relieve the energy load carried by the foot, thus reducing the incidence of march fractures, and should be analyzed in further study.

  • PDF

The effect of botulinum toxin-A injection into the masseter muscles on prevention of plate fracture and post-operative relapse in patients receiving orthognathic surgery

  • Shin, Sung-Ho;Kang, Yei-Jin;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.36.1-36.5
    • /
    • 2018
  • Background: Botulinum toxin-A (BTX-A) injection into muscle reduces muscular power and may prevent post-operative complication after orthognathic surgery. The purpose of this study was (1) to evaluate BTX-A injection into the masseter muscle on the prevention of plate fracture and (2) to compare post-operative relapse between the BTX-A injection group and the no injection group. Methods: Sixteen patients were included in this study. Eight patients received BTX-A injection bilaterally, and eight patients served as control. All patients received bilateral sagittal split ramus osteotomy for the mandibular setback and additional surgery, such as LeFort I osteotomy or genioplasty. Post-operative plate fracture was recorded. SNB angle, mandibular plane angle, and gonial angle were used for post-operative relapse. Results: Total number of fractured plates in patients was 2 out of 16 plates in the BTX-A injection group and that was 8 out of 16 plates in the no treatment group (P = 0.031). However, there were no significant differences in post-operative changes in SNB angle, mandibular plane angle, and gonial angle between groups (P > 0.05). Conclusions: BTX-A injection into the masseter muscle could reduce the incidence of plate fracture.

A Study on the Chattering Phenomena of a Check Valve (역지밸브 채터링 현상 해소방안 연구)

  • 유기완;이준신;김태룡
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.1
    • /
    • pp.36-41
    • /
    • 2002
  • The cause and the elimination method for the chattering phenomena were investigated in a check valve attached to the exit of an auxiliary cooling water pump in a Korean nuclear powerplant. From the site experiment and the numerical calculation, the incident angle of the disk was so small that it was not able to produce the sufficient lifting force to overcome the gravitational component of the disk weight. Moreover, it turned out that the installation position was not symmetric for the secondary vortical flow generated inside the elbow so that the flow structure had strongly unstable flow characteristics. From this study, the tapping noise and the chattering phenomena were eliminated exactly by changing the incidence angle of the valve disk and the installation position of the calve body.

A stydy on the chattering noise elimination of the check valve (역지 밸브 채터링 해소방안 연구)

  • Ryu, Ki-Wahn;Lee, Jun-Shin;Kim, Tae-Ryong;Kim, Kyoung-Ku
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1848-1853
    • /
    • 2000
  • Cause and the elimination method for the chattering phenomena were investigated the check valve attached exit of the auxiliary cooling water pump at a korean nuclear powerplant. From the site experiment and numerical calculation the incident angle of the disk was so small that it was not able to produce the lifting force to overcome the component of disk weight. Moreover, it turned out that the installed position was not symmetric for the secondary vortical flow generated inside the elbow, so that the flow structure had strongly unstable flow characteristics. From this technical support, the tapping noise and the chattering phenomena were eliminated exactly by changing the incidence angle of the valve disk and installed position of the check valve.

  • PDF

Initial Growth and Surface Stability of 1,4,5,8,9,11-Hexaazatriphenylene-exanitrile (HATCN) Thin Film on an Organic Layer

  • Kim, Hyo Jung;Lee, Jeong-Hwan;Kim, Jang-Joo;Lee, Hyun Hwi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.192.2-192.2
    • /
    • 2013
  • Crystalline order and surface stability of 1,4,5,8,9,11-hexaazatriphenylene-hexanitrile (HATCN) thin films on organic surface were investigated using grazing incidence wide angle x-ray scattering and x-ray reflectivity measurements. In the initial growth regime (less than 20 nm), HATCN molecules were stacked to low crystalline order with substantial amorphous phase. Meanwhile, a thicker film with 50 nm thickness showed high crystalline order of hexagonal phase with three different orientational domains. The domain distribution was quantitatively obtained as a function of tilted angle. By an organic-inorganic interface formation of IZO/HATCN thin film from an indium zinc oxide (IZO) electrode deposition, the surface stability of HATCN film was investigated and the sharp interface was confirmed by the x-ray reflectivity measurement.

  • PDF

The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View (Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가)

  • Ko, Ye-Weon;Joo, Young-Cheol;Kim, Min-suk;Go, Yu-Rim
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.