• Title/Summary/Keyword: angle

Search Result 24,740, Processing Time 0.046 seconds

Percutaneous Lateral Release and Medial Reefing for Recurrent Patellar Dislocation (재발성 슬개골 탈구의 경피적 외측부 유리술 및 내측부 중첩술)

  • Choi, Chong-Hyuk;Oh, Kyung-Soo;Kim, Hyoung-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.33-38
    • /
    • 2006
  • Purpose: This study seeks to address the results of percutaneous lateral release and medial reefing for patients with recurrent patellar dislocation. Materials and Methods: This paper focuses on 27 cases from 25 patients who had a surgical operation at our hospital in a span of eight years and six months from the time of December 1996 to May 2005. The subjects consist of 11 males and 14 females, and their average age was 22.2 years old. All the patients had their trauma history, and the average frequency of dislocation before surgery was 11.5 times. Results: The congruence angle before operation was 23.3 degree on the average, while the lateral patellofemoral angle was -5.7 degree on average. However, the congruence angle after surgery came to -2.4 degree, while the lateral patellofemoral angle recovered to the normal range of within 11.5 degrees. Four cases showed the recurrent dislocation, and two out of those four cases had -35, -12 degrees of their lateral patellofemoral angle respectively and 59, 14 degrees of their congruence angle respectively. Conclusion: Using percutaneous lateral release with medial reefing can be considered as an effective treatment for recurrent patellar dislocation

  • PDF

Effect of 8 Weeks of Schroth Exercise (Three-dimensional Convergence Exercise) on Pulmonary Function, Cobb's Angle, and Erector Spinae Muscle Activity in Idiopathic Scoliosis (8주간의 슈로스운동(3차원적 융합운동)이 특발성 척추 측만증 환자의 폐기능과 Cobb's angle, Scoliometer angle, 척추세움근의 근활성도에 미치는 영향)

  • Park, Sang-Yong;Shim, Jae-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.4
    • /
    • pp.61-68
    • /
    • 2014
  • In the present study, we aimed to examine the effects of Schroth exercise(three-dimensional convergence exercise) on pulmonary function(vital capacity, and chest expansion), Cobb's angle, scoliometer angle, and erector spinae muscle activity. We examined 40 students with idiopathic scoliosis(Cobb's angle $10^{\circ}$). They were divided into the Schroth and conventional exercise groups, with 20 people in each group. Statistical analysis was performed by using SPSS 18.0 with a paired t-test(pre-post difference) and an independent t-test(between-group differnence). the result of were as follows; 1) After 8 weeks of Schroth exercise, significant improvements were observed in Cobb's angle, rib hump, vital capacity, chest expansion, and right thoracic longissimus muscle activity. 2) After 8 weeks of conventional exercise, a significant improvement was observed only in chest expansion. These findings indicate that the Schroth exercise program improved the Cobb's angle, rib hump, pulmonary function, and sEMG results. Therefore, this study demonstrates the usefulness of the Schroth exercise program for idiopathic scoliosis.

The Effect of Second Toe Valgus on Correction Loss of Hallux Valgus Angle in Surgical Treatment (무지외반증 수술에서 제 2족지의 외반 정도가 무지 외반각 교정소실에 미치는 영향)

  • Kang, Suk Woong;Song, Moo Ho;Kim, Yeong Joon;Oh, Young Kwang;Yoo, Seong Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.135-138
    • /
    • 2017
  • Purpose: The purpose of this study is to determine the correlation between the correction loss of hallux valgus angle and the severity of valgus angle of the second toe. Materials and Methods: We selected 312 cases from 268 surgical patients with hallux valgus deformity receiving distal chevron osteotomy. For a radiological evaluation, we analyzed the changes in the hallux valgus angles, first to second intermetatarsal angles, and valgus angle of the second toe post index operations. All patients were women; the mean age was 46 years. The mean follow-up period was 17 months. Results: The mean hallux valgus angle was $33.6^{\circ}$ preoperatively (range, $25.7^{\circ}{\sim}44.8^{\circ}$), $13.1^{\circ}$ (range, $8.4^{\circ}{\sim}16.4^{\circ}$) after 4 weeks of postoperative period, and $17.1^{\circ}$ (range, $9.4^{\circ}{\sim}28.5^{\circ}$) at their final follow-up. The mean valgus angle of the second toe was $8.4^{\circ}$ preoperatively (range, $2.0^{\circ}{\sim}25.8^{\circ}$) and $8.3^{\circ}$ (range, $1.7^{\circ}{\sim}24.9^{\circ}$) at the final follow-up. Preoperatively, there was a positive correlation between the valgus angle of the second toe and hallux valgus angle (r=0.747, p=0.001). The correction loss of hallux valgus angle had a significant correlation with the severity of valgus angle of the second toe (r=0.802, p=0.001). Conclusion: The existence of the second toe valgus deformity may present itself as a cause of correction loss of hallux valgus angle. The preoperative measurement of the second toe valgus angle may be a good predictor of correction loss; therefore, thorough preoperative warning on the possibility of correction loss should be conducted to maximize patient satisfaction after the procedure.

Rotor Position Sensorless Control of Optimal Lead Angle in Bifilar-Wound Hybrid Stepping Motor (복권형 하이브리드 스테핑 전동기의 회전차 위치 센서리스 최적 Lead Angle 제어)

  • Lee, Jong-Eon;Woo, Kwang-Joon
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.120-130
    • /
    • 1999
  • In this paper, we show that the instantaneous phase current of the bifiler-wound hybrid stepping motor is dependent of lead angle and that the information of motor position is obtained from the instantaneous phase current at ${\pi}/2$ by the theoretical formular and its computer simulation results. From the facts, we design the microcontroller-based motor position sensorless controller of optimal lead angle, which generates the excitation pulses for the closed-loop drives. The controller is consist of microcontroller which has the function of A/D converter, programmable input/output timer, and the transfer table which has the values of optimal lead angle depending on motor velocity, and ROM which has the transfer table of the values of lead angle depending on velocity of motor and the values of instantaneous phase current at ${\pi}/2$. From the design of microcontroller-based controller, we minimize the external interface circuit and obtain flexibility by changing the contents of ROM transfer tables and the control software. We confirm that the designed controller drives the bifilar-wound hybrid stepping motor is the mode of optimal lead angle by comparing the instananeous phase current experimental results and computer simulation results.

  • PDF

Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint (슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가)

  • Kim, Hyun-jin;Joo, Yeong-chul;Choi, Jae-ho;Lim, Woo-taek
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

Analysis of Forefoot Bending Angle in Sprint Spikes According to Bobsleigh Start Lap Time for Development of Korean-Specific Bobsledding Shoes

  • Park, Seungbum;Lee, Kyungdeuk;Kim, Daewoong;Yoo, Junghyeon;Jung, Jaemin;Park, Kyunghwan;Park, Sungwon;Kim, Jinhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.315-321
    • /
    • 2016
  • Objective: The aim of this study was to analyze effects of the toe-spring angle of bobsleigh shoes on start speed lap time to develop Korean-specific bobsled shoes suitable for winter environments and for domestic players on the basis of sports science and optimized biomechanical performance. Method: Seven Korean bobsleigh athletes participated in this study, with three pairs of sprint spikes from three companies (Type A, Type B, Type C). To analyze sprint lap time and forefoot bending angle for each shoe, participants were instructed to drag a sled 15 meters from the start line at a maximum sprint. forefoot bending angle was collected by a high speed camera, and lap time speed was measured. Results: Lap time for type B shoes was $3.52{\pm}0.17sec$, type A was $3.55{\pm}0.19sec$, and type C was $3.56{\pm}0.18sec$. Forefoot bending angles were: angle 1, $6.88{\pm}5.55^{\circ}$; angle 2, $9.23{\pm}6.38^{\circ}$; angle 3, $15.56{\pm}5.39^{\circ}$; angle 4, $9.54{\pm}3.85^{\circ}$; angle 5, $9.22{\pm}5.08^{\circ}$; angle 6, $7.66{\pm}6.44^{\circ}$; and angle 7, $4.30{\pm}6.24^{\circ}$ (p<.001). Forefoot bending in angle 3 was as follows: type A, $16.47{\pm}6.01^{\circ}$; type B, $14.30{\pm}4.96^{\circ}$; and type C, $15.90{\pm}5.17^{\circ}$. Conclusion: Hard outsoles and midsoles are better than soft type for reduced start lap time when developing a prototype Korean bobsled shoe.

Technical Improvement for Spine Radiography by Comparing Scoliotic and Lordotic Angle with Different Positioning Methods (촬영자세별 척추측만각과 척추전만각의 비교 분석에 따른 개선 방안)

  • Jung, Jae-Yeon;Son, Soon-Yong;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.263-269
    • /
    • 2011
  • Since the spine radiography were explained differently at every several hospitals and textbooks. the technique has not been accurately defined and interfered each other. We would like to define the most appropriate positioning for clinical cases, and reference books, by comparing scoliotic angle and lordotic angle. From Mar 2009 to Sep 2011, 85 patient cases were studied, who had not been undergone surgical treatment among spondylopathy patients. Scoliotic angle and lordotic angle were measured, using Cobb's method. We analyzed statistically using t-test(SPSS 18), and evaluated spine general radiography position. Moreover, we researched on the actual condition at 10 university hospitals in Seoul. The results of scoliotic angle measurement, the value at erect position showed 20.98% higher than supine position, and it has statistical significance (p<.01). In lordotic angle measurement, the value at neutral holding position represented 29.3% higher than supine position, and it also has statistical significance(p<.01). The results of clinical survey, supine posine(70.0%) took much higher possession than erect position(30.0%). In conclusion, compare to supine position, erect position shows increased scoliotic and lordotic angle. It was agreed with the importance of clinical erect position radiography, which gravity affects. So clinical radiologist must recognize the difference, and conduct an accurate study.

The Effect of Tomographic Angles on the Osteophytic Lesion Detectability of the Mandibular Condyle (단층촬영 각도의 변화가 하악과두의 골 증식성 병소의 인식에 미치는 영향)

  • Han Sang-Sun;Kim Kee-Deog
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.309-325
    • /
    • 1999
  • Purpose: To find out the effects that different tomographic angles have on the osteophytic lesion detectability of condyle head by comparison the individualized lateral tomographic image with the various tomographic angled images using SCANORA/sup (R)/. Materials & Methods: This study is performed to simulate osteophytic lesions by a series of dentin chips placed at six locations on condyle head. The control angle is 15° and from this angle. tomographic angle were varied with -10°, +10°, +20°. All the images with each sized dentin chip were scored by three dental radiologists with the use of confidence levels for presence or absence of the lesion, each examiner viewed one of the images twice. A rating scale from 0 to 2 (0, lesion definitely not present; 1. uncertain if lesion is present; 2, lesion definitely present). Responses were assessed by Tukey' s multiple comparison method and kappa value. Results: 1. The lesion size of 0.3 mm could not be detected in all the tomographic angles. As the size of the lesion increased the average value of lesion detectability also increased. 2. In the lesion sizes of 0.7 mm there was statistically significant difference between the 15° control angle and the altered tomographic angles (p<0.05). In 1.0 mm lesion there was no significant difference in the ±10° altered angles (p >0.05). but there was significant difference in the altered angle (p<0.05). In the lesion sizes of 0.3 mm and 2.0 mm there was no significant difference between the 15° control angle and all the altered angles (p >0.05). 3. In the anteromedial. anterosuperior, anterolateral area there was no significant difference between the 15° control angle and the ±10° altered angle (p >0.05), but in the comparison with the +20° altered angle there was significant difference (p<0.05). Conclusion: When imaging the lateral tomography of the temporomandibular joint used by SCANORA/sup (R)/, it can be considered that in the osteophytic lesion size of 2 mm and above, the tomographic angle difference within +20° to the horizontal angle of the condyle. has little effect on the lesion detectability. And in the lesion size of 1 mm, the altered angle within ±10° also has little effect on the lesion detectability.

  • PDF

The Comparison of Kinematic Data of the Body Orientation in Sitting Position to Adapt Dynamically Changing Angle of the Base of Support in Stroke Patients and Healthy Adults (뇌졸중 환자와 정상 성인의 앉은 자세에서 지지면의 동적 각도 변화에 적응하는 신체 정위의 운동형상학적 비교)

  • Song, In-Su;Choi, Jong-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3513-3520
    • /
    • 2012
  • This study aimed to investigate the difference of the body orientation ability in sitting position to adapt to dynamically changing angle of the base of support in stroke patients and Healthy adults. The angle between vertical and head and trunk in 12 stroke patients (6 male and 6 female) and 12 healthy adults (6 male and 6 female) were measured by video motion analysis system. The head and trunk angle between stroke patients and healthy adults in sitting position were significantly different when increase the angle of dominant side(p<.05). The head and trunk angle between stroke patients and healthy adults in sitting position were significantly different when increase the angle of non-dominant side(p<.05). The head and trunk angle between stroke patients and healthy adults in sitting position were significantly different when decrease the angle of non-dominant side(p<.05). The head angle between stroke patients and healthy adults in sitting position was significantly different(p<.05), but the trunk angle was not significantly different when decrease the angle of dominant side(p>.05), Stroke patients compared to healthy adults had more deficits in their body orientation ability in sitting position to adapt to dynamically changing angle of the base of support. This finding may help to understand postural control deficits more clearly in stroke patients in sitting position.

A Study on the Hyperspectral Image Classification with the Iterative Self-Organizing Unsupervised Spectral Angle Classification (반복최적화 무감독 분광각 분류 기법을 이용한 하이퍼스펙트럴 영상 분류에 관한 연구)

  • Jo Hyun-Gee;Kim Dae-Sung;Yu Ki-Yun;Kim Yong-Il
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.2
    • /
    • pp.111-121
    • /
    • 2006
  • The classification using spectral angle is a new approach based on the fact that the spectra of the same type of surface objects in RS data are approximately linearly scaled variations of one another due to atmospheric and topographic effects. There are many researches on the unsupervised classification using spectral angle recently. Nevertheless, there are only a few which consider the characteristics of Hyperspectral data. On this study, we propose the ISOMUSAC(Iterative Self-Organizing Modified Unsupervised Spectral Angle Classification) which can supplement the defects of previous unsupervised spectral angle classification. ISOMUSAC uses the Angle Division for the selection of seed points and calculates the center of clusters using spectral angle. In addition, ISOMUSAC perform the iterative merging and splitting clusters. As a result, the proposed algorithm can reduce the time of processing and generate better classification result than previous unsupervised classification algorithms by visual and quantitative analysis. For the comparison with previous unsupervised spectral angle classification by quantitative analysis, we propose Validity Index using spectral angle.