• Title/Summary/Keyword: angle

Search Result 24,685, Processing Time 0.047 seconds

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.

Types of tweezers and their culture of use (족집게(鑷)의 유형과 사용 문화)

  • KIM, Jihyeon
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.3
    • /
    • pp.4-23
    • /
    • 2021
  • The purpose of this study was to classify the types of tweezers used across time and to examine the social culture of periods through the use of tweezers. Chapter II summarized the terms for tweezers and looked at the use of tweezers in two cases related to the social culture and politics of a period. The first is the use of tweezers for beauty purposes. Men used tweezers as a kind of self-management to maintain their social status and power, and thus they helped develop a wide range of tweezers cultures. People with gray hair are usually old. The perception that we should step down from politics when we are aged has become strong. Therefore, politicians pulled out gray hairs with tweezers to maintain only black hair and show youth, which indicates that their social influence is still strong. The second is the use of tweezers for first aid. Chapter III classified tweezers by type during the Goryeo and Joseon periods. The tweezers are largely divided into basic and composite types. The basic type of tweezers is a form that has been continued since the Three Kingdoms Period and consists of tongs and handles, and a fixed type of tweezers with a fixed ring appeared. Composite tweezers are made by grafting earpick or multipurpose knives. Composite tweezers are all-in-one tweezers with an earpick and an all-in-one knife. Tweezers are usually all-in-one. Among the composite tweezers, rivet separation and ring separation are characterized by separation, unlike the all-in-one tweezers. The method of connecting is divided into rivets and connection rings. The all-in-one tweezers appear only during the Goryeo Dynasty and are characterized by the lifestyle that provides a glimpse of the tastes of contemporary users. The manufacturing takes shape after making a thin metal plate. Decorative techniques are carved on soft metal tweezers, such as silver and bronze with a line, point, and a pressed angle. These tweezers are presumed to have been used by the royal family or aristocrats. However, most tweezers are made of strong bronze or iron. Therefore, the majority of simple X-shaped patterns are sampled or without patterns. The biggest reason why there are such diverse types of tweezers is that the culture of tweezers was widespread regardless of the times. In addition, the basic type of tweezers has been used since the Three Kingdoms Period and has been modified and used together as necessary because the shape of tweezers is a practical daily tool. Study of metal crafts have been limited to royal objects and Buddhist crafts. We hope that research on everyday tools such as tweezers will continue to serve as an opportunity to examine the social and cultural aspects of the times in various ways.

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.

Investigation on Diesel Injection Characteristics of Natural Gas-Diesel Dual Fuel Engine for Stable Combustion and Efficiency Improvement Under 50% Load Condition (천연가스-디젤 혼소 엔진의 50% 부하 조건에서 제동효율 및 연소안정성 개선을 위한 디젤 분무 특성 평가)

  • Oh, Sechul;Oh, Junho;Jang, Hyungjun;Lee, Jeongwoo;Lee, Seokhwan;Lee, Sunyoup;Kim, Changgi
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.3
    • /
    • pp.45-53
    • /
    • 2022
  • In order to improve the emission of diesel engines, natural gas-diesel dual fuel combustion compression ignition engines are in the spotlight. In particular, a reactivity controlled compression ignition (RCCI) combustion strategy is investigated comprehensively due to its possibility to improve both efficiency and emissions. With advanced diesel direct injection timing earlier than TDC, it achieves spontaneous reaction with overall lean mixture from a homogeneous mixture in the entire cylinder area, reducing nitrogen oxides (NOx) and particulate matter (PM) and improving braking heat efficiency at the same time. However, there is a disadvantage in that the amount of incomplete combustion increases in a low load region with a relatively small amount of fuel-air. To solve this, sensitive control according to the diesel injection timing and fuel ratio is required. In this study, experiments were conducted to improve efficiency and exhaust emissions of the natural gas-diesel dual fuel engine at low load, and evaluate combustion stability according to the diesel injection timing at the operation point for power generation. A 6 L-class commercial diesel engine was used for the experiment which was conducted under a 50% load range (~50 kW) at 1,800 rpm. Two injectors with different spray patterns were applied to the experiment, and the fraction of natural gas and diesel injection timing were selected as main parameters. Based on the experimental results, it was confirmed that the brake thermal efficiency increased by up to 1.3%p in the modified injector with the narrow-angle injection added. In addition, the spray pattern of the modified injector was suitable for premixed combustion, increasing operable range in consideration of combustion instability, torque reduction, and emissions level under Tier-V level (0.4 g/kWh for NOx).

Evaluation of Sensitivity and Retrieval Possibility of Land Surface Temperature in the Mid-infrared Wavelength through Radiative Transfer Simulation (복사전달모의를 통한 중적외 파장역의 민감도 분석 및 지표면온도 산출 가능성 평가)

  • Choi, Youn-Young;Suh, Myoung-Seok;Cha, DongHwan;Seo, DooChun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1423-1444
    • /
    • 2022
  • In this study, the sensitivity of the mid-infrared radiance to atmospheric and surface factors was analyzed using the radiative transfer model, MODerate resolution atmospheric TRANsmission (MODTRAN6)'s simulation data. The possibility of retrieving the land surface temperature (LST) using only the mid-infrared bands at night was evaluated. Based on the sensitivity results, the LST retrieval algorithm that reflects various factors for night was developed, and the level of the LST retrieval algorithm was evaluated using reference LST and observed LST. Sensitivity experiments were conducted on the atmospheric profiles, carbon dioxide, ozone, diurnal variation of LST, land surface emissivity (LSE), and satellite viewing zenith angle (VZA), which mainly affect satellite remote sensing. To evaluate the possibility of using split-window method, the mid-infrared wavelength was divided into two bands based on the transmissivity. Regardless of the band, the top of atmosphere (TOA) temperature is most affected by atmospheric profile, and is affected in order of LSE, diurnal variation of LST, and satellite VZA. In all experiments, band 1, which corresponds to the atmospheric window, has lower sensitivity, whereas band 2, which includes ozone and water vapor absorption, has higher sensitivity. The evaluation results for the LST retrieval algorithm using prescribed LST showed that the correlation coefficient (CC), the bias and the root mean squared error (RMSE) is 0.999, 0.023K and 0.437K, respectively. Also, the validation with 26 in-situ observation data in 2021 showed that the CC, bias and RMSE is 0.993, 1.875K and 2.079K, respectively. The results of this study suggest that the LST can be retrieved using different characteristics of the two bands of mid-infrared to the atmospheric and surface conditions at night. Therefore, it is necessary to retrieve the LST using satellite data equipped with sensors in the mid-infrared bands.

3D Point Cloud Reconstruction Technique from 2D Image Using Efficient Feature Map Extraction Network (효율적인 feature map 추출 네트워크를 이용한 2D 이미지에서의 3D 포인트 클라우드 재구축 기법)

  • Kim, Jeong-Yoon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.408-415
    • /
    • 2022
  • In this paper, we propose a 3D point cloud reconstruction technique from 2D images using efficient feature map extraction network. The originality of the method proposed in this paper is as follows. First, we use a new feature map extraction network that is about 27% efficient than existing techniques in terms of memory. The proposed network does not reduce the size to the middle of the deep learning network, so important information required for 3D point cloud reconstruction is not lost. We solved the memory increase problem caused by the non-reduced image size by reducing the number of channels and by efficiently configuring the deep learning network to be shallow. Second, by preserving the high-resolution features of the 2D image, the accuracy can be further improved than that of the conventional technique. The feature map extracted from the non-reduced image contains more detailed information than the existing method, which can further improve the reconstruction accuracy of the 3D point cloud. Third, we use a divergence loss that does not require shooting information. The fact that not only the 2D image but also the shooting angle is required for learning, the dataset must contain detailed information and it is a disadvantage that makes it difficult to construct the dataset. In this paper, the accuracy of the reconstruction of the 3D point cloud can be increased by increasing the diversity of information through randomness without additional shooting information. In order to objectively evaluate the performance of the proposed method, using the ShapeNet dataset and using the same method as in the comparative papers, the CD value of the method proposed in this paper is 5.87, the EMD value is 5.81, and the FLOPs value is 2.9G. It was calculated. On the other hand, the lower the CD and EMD values, the better the accuracy of the reconstructed 3D point cloud approaches the original. In addition, the lower the number of FLOPs, the less memory is required for the deep learning network. Therefore, the CD, EMD, and FLOPs performance evaluation results of the proposed method showed about 27% improvement in memory and 6.3% in terms of accuracy compared to the methods in other papers, demonstrating objective performance.

Clinical Results of Medial Unicompartmental Knee Arthroplasty in Elderly Patients Older than 70 Years of Age (70세 이상의 고령 환자에서 시행한 내측 슬관절 단일구획치환술의 임상 결과)

  • Kim, Kyung Tae;Lee, Song;Kim, Jin Hak;Lee, Ho Young;Kim, Myung Jin
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • Purpose: To evaluate the long-term clinical results and survivorship of unicompartmental knee arthroplasty (UKA) in elderly patients older than 70 years by analyzing cases that have been implanted for >10 years ago. Materials and Methods: The long-term follow-up results were evaluated in 39 patients (46 cases) who underwent medial UKA from March 2002 to February 2004. The mean age of the patients at the time of surgery was 74.0 years, and the preoperative diagnosis was degenerative arthritis of the knee in all cases. Results: Of the 46 cases, reoperation occurred due to the complications in four cases. In 22 cases without 14 cases of death and six cases of follow-up loss, follow-up more than 10 years was possible. The mean Knee Society knee and function scores improved significantly from 53.0 and 52.5 points pre-operatively to 89.4 and 80.9 points at the last follow-up, respectively (p<0.001). The mean range of motion of the knee recovered to 132.5°, and the mean tibiofemoral angle changed to 5.9° of valgus at the last follow-up. Complications following the UKA occurred in four cases; the most prevalent complication was mobile bearing dislocation (n=2). One case of failure occurred due to aseptic loosening and degenerative arthritis of the lateral compartment, respectively. The cumulative survival rate of the implants was 95.0% at 10 years and 85.7% at 15 years. Of the 40 cases, excluding six cases of follow-up loss, 36 cases (90.0%) could be used without reoperation until death or at the last follow-up after surgery. Conclusion: These results showed the outstanding functions of the knee and satisfactory long-term survivorship after UKA. Therefore, UKA could be a useful method for the treatment of osteoarthritis of the knee in elderly patients older than 70 years of age.

Preliminary Result of Revision Fusion Surgery for Thoracolumbar Spine Using Revision Rod (Revision Rod를 이용한 흉요추 유합 재수술 예비 결과)

  • Youn, Yung-Hun;Cho, Kyu-Jung;Park, Ye-Su;Park, Jae-Woo;Park, Jin-Sung;Kwon, Won-Hwan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.520-526
    • /
    • 2020
  • Purpose: The need for revision fusion surgery after spinal fusion has increased. A revision rod that connects to the previous rod was newly developed for revision surgery. The purpose of this study was to analyze the clinical and radiological results after spinal fusion revision surgery using revision rods. Materials and Methods: Twenty-one patients who underwent revision fusion surgery after spinal fusion in two university hospitals with minimum 1 year follow-up were reviewed. This study assessed 16 cases of adjacent-segment disease, four cases of thoracolumbar fracture, and one case of ossification of ligament flavum. The Oswestry Disability Index (ODI) and numerical rating scale (NRS) were evaluated as clinical outcomes, and the union rate, lordosis or kyphosis of the revision level, lumbar lordosis, T5-12 kyphosis, and proximal junctional kyphosis angle were evaluated as the radiological outcomes. Results: The average ODI was 54.6±12.5 before surgery and improved to 29.8±16.5 at the final follow-up. The NRS for back pain and leg pain was 5.0±1.7 and 6.4±2.0 before surgery, which changed to 2.9±1.6 and 2.9±2.2 at the final follow-up. Lumbar lordosis was 18.1°±11.9° before surgery and 21.1°±10.3° at the final follow-up. Proximal junctional kyphosis was 10.8°±10.1° before surgery, and 9.2°±10.5° at the final follow-up. These angles were not changed significantly after surgery. Bony union was successful in all cases except for one case who underwent posterolateral fusion. Conclusion: Revision surgery using a newly developed revision rod on the thoracolumbar spine achieved good clinical outcomes with successful bony union. No problems with the newly developed revision rod were encountered.

Clinical Results of Lateral-Posterior Internal Fixation for the Treatment of Scapular Body Fractures (견갑골 체부 골절에서 외측 후방 금속판 고정술의 치료 결과)

  • Lee, Yoon-Min;Yeo, Joo-Dong;Song, Seok-Whan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.46-53
    • /
    • 2020
  • Purpose: Scapular body fractures have generally been treated with non-surgical methods. This study reports the clinical and radiological outcomes after lateral-posterior internal fixation for treating displaced scapular body fractures. Materials and Methods: From March 2007 to May 2017, out of 40 patients who underwent internal fixation for scapular fractures, 13 cases of lateral plate fixation of a scapular body fracture were reviewed retrospectively. Preoperative and postoperative displacement, angulation and glenopolar angle (GPA) were measured. The range of shoulder motion, visual analogue scale (VAS), and disabilities of the arm, shoulder, and hand (DASH), and Constant score were assessed at the last follow-up. Results: The mean follow-up period was 17.7 months (range, 6-45 months). The mean preoperative GPA was 23.3°±3.96° (range, 17.8°-28.1°) and the postoperative GPA was 31.1°±4.75° (range, 22.5°-40.1°). Injury to the suprascapular nerve, nonunion, fracture redisplacement, metallic failure, or infection did not occur. At the last follow-up, the mean range of motion was 150.5°±19.3° in forward flexion, 146.6°±2.34° in lateral abduction, 66.6°±19.1° in external rotation, and 61.6°±18.9° in internal rotation. The VAS, DASH, and Constant scores were 1.7±1.3, 6.2±2.4, and 86±7.9 points, respectively. Conclusion: A scapular body fracture with severe displacement, angulation and marked decreased GPA can be stabilized by lateralposterior plate fixation using the appropriate surgical technique with good functional and radiological results.