• Title/Summary/Keyword: angle

Search Result 24,686, Processing Time 0.048 seconds

An Experimental Study on Selection Pitch Angle on backward flow of an Axial Fan with Adjustable Pitch Angle Blades (피치각 조정형 송풍-역풍 겸용 축류팬에서 배연용 피치각 선정을 위한 실험적 연구)

  • Chang, Taek-Soon;Hur, Jin-Huek;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.5 no.1
    • /
    • pp.45-50
    • /
    • 2009
  • In this study, the experimental study has carried out to select pitch angle on the backward flow in an axial fan that has adjustable pitch blades. With the change of pitch angle of axial fan with adjustable blade, air flow rate, pressure and air flow direction can be changed. Because of this merit, adjustable axial fan can be used in the backward flow. For the selection of the backward flow pitch angle, fan performance test method is selected by KS B 6311. Dynamic pressure, static pressure, electric current and voltage are measured in each pitch angles of axial fan that are $36^{\circ}$, $-16^{\circ}$, $-21^{\circ}$, $-26^{\circ}$, $-31^{\circ}$ and $-36^{\circ}$. In the result of test, fan performance curves at several pitch angle has been investigated. Finally, pitch angle of $-26^{\circ}$ has been selected to get largest flow rate at backward flow situation.

  • PDF

IMPROVEMENT OF DRIFT RUNNING PERFORMANCE BY STEERING SYSTEM WHICH ADDS DIFFERENTIATION STEER ASSISTANCE

  • NOZAKI H.
    • International Journal of Automotive Technology
    • /
    • v.6 no.6
    • /
    • pp.615-623
    • /
    • 2005
  • In this research, an effective technique was examined to improve the drift running performance. Concretely, the driver model by which the counter steer was done was assumed to the model by which the vehicle body slip angle (and the vehicle body slip angle velocity) was feed back. Next, the effectiveness of the system which added the assist steer angle corresponding to the steering wheel angle velocity to a front wheel steer angle was clarified as a drift running performance improvement technique of the vehicle. As a result, because the phase advances when the differentiation steer assistance is added, it has been understood to be able to cover the delay of the counter steer when the drift running. Therefore, it has been understood that the drift control does considerably easily. Moreover, it has been understood that the differentiation steer assistance acts effectively at the drift cornering by which the drift angle is maintained in cornering and the severe lane change with a drift at a situation. That is, it was understood to be able to settle to the drift angle of the aim quickly at the time of the drift cornering because the delay of the control steer angle of the counter steer was improved. Moreover, it was understood for the transient overshoot of the vehicle tracks to be able to decrease, and to return to the state of stability quickly at the severe lane change.

Effects of EMG-Biofeedback Using Closed Kinetic Chain Exercise on Q-angle and Quadriceps Muscle Activation in Patellofemoral Pain Syndrome

  • Kim, Je-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.65-70
    • /
    • 2016
  • Purpose: The aim of this study was to determine the effects of electromyographic (EMG)-Biofeedback using closed kinetic chain exercise (EB-CKCE) on quadriceps angle (Q-angle) and quadriceps muscle activation and muscle activation ratio in subjects with patellofemoral pain syndrome and to provide fundamental information on rehabilitation exercise in patellofemoral pain syndrome. Methods: Thirty participants who met the criteria were included. The subjects were randomly divided into three groups: control group (Group I, n=10), semi-squat exercise group (Group II, n=10), and EMG-Biofeedback using closed kinetic chain exercise group (Group III, n=10). Intervention was provided to each group for eight weeks (three times per week; 30 minutes per day). Subjects were measured on Q-angle and quadriceps muscle activation. Results: Significant difference in Q-angle and quadriceps muscle activation was observed in groups II and III compared with control group I (p<0.01). Results of post-hoc analysis showed a significant difference in Q-angle and quadriceps muscle activation in on group III compared with groups I and II. Conclusion: Findings of this study suggest that closed kinetic chain exercise using EMG-Biofeedback that provides real-time biofeedback information on muscle contraction may have a beneficial effect on improvement of Q-angle and quadriceps muscle activation in patellofemoral pain syndrome.

RELATIONSHIPS BETWEEN MANDIBULAR ANGLE FRACTURE AND STATE OF THE LOWER THIRD MOLAR (하악제3대구치의 존재양상과 하악우각부 골절과의 관계)

  • Kim, Hee-Kwang
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.6
    • /
    • pp.530-535
    • /
    • 2004
  • Objectives. The purpose of this study was to evaluate mandibular third molars as risk factors for angle fracture in a patient sample with fractured mandible. Materials and methods. The medical records and panoramic radiographs of 107 patients with mandibular fractures were examined. The presence and absence and degree of impaction of the lower third molar were assessed for each patient and related to the occurrence of fracture of the mandibular angle. Data were also collected for age, sex and mechanism of injury. Data were analyzed by a chisquare statistics and Student t test. Result. The incidence of mandibular angle fracture was found to be significantly greater when a lower third molar was present(p <0.05) especially at class III state.(p < 0.05)(by Pell & Gregory system) Of the 78 patients with a lower third molar, 46(58.97%) had angle fractures. Of the 29 without a lower third molar, 24(82.76%) had not angle fractures. Conclusion. The result of this study showed that the mandibular angle that have a lower third molar is more susceptible to fracture when exposed to an impact than an angle without an lower third molar.

A Comparative Sudy on Accuracy of Occlusal Plane Angle on Mounting The Hanau 96-H2 Articulator (Hanau 96-H₂교합기에 상악 모형 부착시 교합면 경사각에 대한 비교 연구)

  • Hwang, Hie-Seong;Lee, Ho-Yong
    • The Journal of the Korean dental association
    • /
    • v.25 no.9 s.220
    • /
    • pp.861-872
    • /
    • 1987
  • The Purpose of this study was to know the differences between the occlusal plane angles formed by F-H plane on cephalograms and the occlusal plane angles by the upper margin of the articulator, and to ind the contributing factors to the difference of occlusal angles. for this study, 39 young adults (20 men, 19 women) were selected who had normal occlusion, no severe attrition, no missing tooth, not been under orthodontic treatment and occlusal equilibration and no temporomandibular disorders. The maxillary casts were mounted with Hanau 159-1 ear piece type face-bow and measured the occlusal plane angle with prototype occlusal plane projector. The following results were obtained; 1. The mean value of the ear rod F-H plane occlusal angle was 14.75˚, articulator occlusal angle was 9.26˚ and strong positive correlation between these angles, 2. It was almost same angle between the ear rod F-H plane angle (14.75˚) and the beyron point to infraorbital rim-6mm. occlusal angle (14.46˚) 3. The mean distance from the ear rod porion to the Byron point was 5.67mm. 4. It was no significant correlation between the distances Po-Beyron point, Or-infraorbital rim and articulator occlusal angle.

  • PDF

Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

  • Sim, Sook Young;Choi, Chi Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.400-404
    • /
    • 2014
  • Objective : Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. Methods : Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the angle and number of streak artifacts in axial images, and the maximal diameter of artifacts in three-dimensional (3-D) volume-rendered images. The correlation coefficient (CC) was determined between each clip artifact type and the clip blade length and clip orientation to the CT scan (angle a, lateral clip inclination in axial images; angle b, clip gradient to scan plane in lateral scout images). Results : Angle b correlated negatively with white artifacts (r=-0.589, p<0.001) and positively with the angle (r=0.636, p<0.001) and number (r=0.505, p<0.001) of streak artifacts. Artifacts in 3-D images correlated with clip blade length (r=0.454, p=0.004). Multiple linear regression analysis revealed that angle b was the major parameter influencing white artifacts and the angle and number of streak artifacts in axial images (p<0.001), whereas clip blade length was a major factor in 3-D images (p=0.034). Conclusion : Use of a clip orientation perpendicular to the scan gantry angle decreased the amount of white artifacts and allowed better visualization of the clip site.

Flow and Heat Transfer Measurements of Film Injectant from a Row of Holes with Compound Angle Orientations

  • Bumsoo Han;Sohn, Dong-Kee;Lee, Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1137-1146
    • /
    • 2002
  • An experiment has been conducted on the flow and heat transfer characteristics of film coolant injected from a row of five holes with compound angle orientations of 35$^{\circ}$ inclination angle and 45$^{\circ}$ orientation angle. The Reynolds number based on the mainstream velocity and injection hole diameter 3.58${\times}$10$^4$. Three-dimensional velocity, film cooling effectiveness and heat transfer coefficient data are presented at three different mass flux ratios of 0.5, 1.0 and 2.0. Flow entrainment has been found between the vortices generated by adjacent injectants. The injectant with compound angle orientation entrains not only the mainstream boundary layer flow but also the adjacent injectant. Because of the flow entrainment, the injectant. With compound angle orientation is characterized by a single vortex while two bound vortices are usually observed in the case of simple angle injection. The strength of the secondary flow depends strongly on the mass flux ratio, which shows significant influence on the film cooling effectiveness and heat transfer coefficient.

Cluster Analysis for Foot Type (II) -The subject of the college men between the age of 19~24 years- (발의 형태 분석을 위한 군집분석(II) -19~24세 남자대학생을 중심으로-)

  • 문명옥
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.5
    • /
    • pp.637-645
    • /
    • 1994
  • The purpose of this study was to analyze the characteristics of men's foot and the foot type by cluster analysis for men's footwear. The sample size for the study was 200 college men between age 19 and 24 in Pusan urban area. There were measured 17 items of the foot for factor analysis and cluster analysis. The result was as follows: 1. The size of If items of men's foot is larger than women's foot. 2. There were 9 items selected by factor analysis. 3. The cluster analysis of the direct measurement: Cluster 1: The items of the direct measurement is all much the same to mean value of this age group. Cluster 2: The foot size is relatively small to other clusters. Cluster 3: The foot size is relatively large to other clusters. 4. The cluster analysis of indirect measurement: Cluster 1: The foot print angle is the most value and Metatarso-Phalanx angle is nomral Cluster 2: The foot print angle is middle and Metatarso-Phalanx angle is normal. Cluster 3: The foot print angle is high and Metatarso-Phalanx angle is the smallest. Cluster 4: The foot print angle is low and Metatarso-Phalanx angle is all the much same to mean value of this age group.

  • PDF

Influence on the Difference in Proportion of Leg Joint Angle during Walking, Cobb's Angle, Foot Pressure (가방 착용 방법에 따른 보행 시 다리관절 각도, 콥스 각, 족압 비율의 변화)

  • Lee, Jonathan;Lee, Su-Hyun;Jang, Sang-Hun
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.2
    • /
    • pp.7-14
    • /
    • 2018
  • Purpose: This study was conducted to analyze the effect of bag type on gait kinematic factors. The purpose of this study was to compare the Cobb's angle, leg angle and foot pressure difference according to bag type among 20 university students. Methods: The bag type was applied with two kinds of bags: not wearing a bag, backpack, and an eco bag. The bag weight was 10% of subjects weight in during experiment and only bag weight was 0.5kg. Results: Knee joint angle is increased when wearing backpack or an eco bag than not wearing bag. Cobb's angle increased when wearing backpack and wearing eco back. The difference in right and left foot pressure increased when wearing eco bag than not wearing bag and wearing backpack. Conclusion: Therefore, wearing a heavy backpack or an eco bag when walking for a long time may cause scoliosis and change the walking form.

Effects of UV light irradiation condition and imidization temperature for the generation of pretilt angle on polyimide surfaces (폴리이미드 표면에서의 프리틸트각 발생에 대한 UV조사 조건과 이미드화온도의 영향)

  • Yu, Mun-Sang;Seo, Dae-Shik;Hwang, Jeoung-Yeon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.61-64
    • /
    • 1998
  • We have investigated the effects of ultraviolet (UV) light irradiation condition and imidization temperature for the generation of pretilt angle in nematic liquid crystal (NLC) on the two kinds of the polyimide (PI) surfaces. High pretilt angle of NLC is generated with oblique p-polarized UV light irradiation of 30$^{\circ}$ on PI surface for 20 min. Also, the high pretilt angle of NLC is generated with oblique p-polarized UV light irradiation of 10-30$^{\circ}$ on PI surface at 20min. The pretilt angle of NLC decreases with increasing the imidization temperature on all rubbed PI surfaces ; the pretilt angle of NLC with oblique p-polarized UV light irradiation of 30$^{\circ}$on PI surface decreases with increasing the imidization temperature. The high pretilt angle of NLC is observed due to high photo-depolymerization reaction by low surface energy at low imidization temperature. We suggest that the pretilt angle of NLC is strongly attributed to the photo-depolymerization reaction with the UV light irradiation condition and imidization temperature.

  • PDF