• 제목/요약/키워드: anemometry

검색결과 103건 처리시간 0.022초

나선형의 표면돌출물이 부착된 원주의 근접후류에 관한 실험적 연구 (Experimental Study on the Near Wake Behind a Circular Cylinder with Helical Surface Protrusions)

  • 권기정;김형범
    • 대한기계학회논문집B
    • /
    • 제20권8호
    • /
    • pp.2601-2610
    • /
    • 1996
  • Surface protrusions have been attached on a cylinder surface to reduce the flow-induced structural vibration by controlling the wake flow. Wind tunnel tests on the near wake of a circular cylinder with surface protrusions were carried out to investigate the flow characteristics of the controlled wake. Three experimental models were used in this experiment; one plain cylinder of diameter D and two cylinders wrapped helically by three small wires of diameter d=0.075D with pitches of 5D and 10D, respectively. Free stream velocity was ranged to have Reynolds number from 5000 to 50,000. Streamwise and vertical velocity components of the wake were measured by a hot-wire anemometry. The spanwise velocity component measured by a one-component fiber optic LDV revealed that time-averaged wake field has a nearly two-dimensional structure. It was found that the surface protrusions elongate the vortex formation region, which decrease the vortex shedding frequency. The suppression of vortices caused by the surface protrusions increases the velocity deficit in the center of wake region.

유츨 허브를 갖는 HDD내 동시회전디스크 표면에서의 열전달 및 유동특성 해석 (Heat Transfer and Flow Characteristics on Co-rotating Disks with a Ventilation Hub in Hard Disk Drive)

  • 조형희;원정호;류구영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.382-389
    • /
    • 2001
  • In the present study, local heat transfer rates for co-rotating disks with two modified hubs having ventilation holes are investigated for Rossby number of 0.04, 0.1 and 0.35 to evaluate the influence of incoming flows through hub holes. A naphthalene sublimation technique is employed to determine the detailed local heat/mass transfer coefficients on the rotating disks using the heat and mass transfer analogy. Flow field measurements are conducted using Laser Doppler Anemometry (LDA) and numerical calculations are performed simultaneously to analyze the flow patterns induced by the disk rotation. The basic flow structure in a cavity between co-rotating disks consists of three regions; the solid-body rotating inner region, the outer region with turbulence vortices and the shroud boundary layer region. The heat/mass transfer. rates on the co-rotating disks are very low near the hub due to the solid-body rotation and those increase rapidly in the outer region due to turbulence mixing. The modified hubs with ventilation holes enhances significantly the heat/mass transfer rates on the region near the hub. The results also show that the heat transfer of Hub-2 is superior to that of Hub-1, but Hub-1 is more profitable for destructing the solid-body rotating inner region.

  • PDF

예혼합 연소기에서의 화염 전달 함수 측정 (Flame Transfer Function Measurement in a Premixed Combustor)

  • 김대식;김기태;전승배;이종근
    • 한국연소학회지
    • /
    • 제13권2호
    • /
    • pp.1-6
    • /
    • 2008
  • An experimental study of the flame response in a turbulent premixed combustor has been conducted with room temperature, atmospheric pressure inlet conditions using premixed natural gas. The fuel is premixed with the air upstream of a choked inlet to avoid equivalence ratio fluctuations. Therefore the observed flame response is only the result of the imposed velocity fluctuations, which are produced using a variable speed siren. Measurements are made of the velocity fluctuation in the nozzle using hot wire anemometry and of the heat release fluctuation in the combustor using chemiluminescence emission. The results are analyzed to determine the phase and gain of the flame transfer function as a function of the modulation frequency. Of particular interest is the effect of flame structure on the flame response predictions and measurements. The results show that both the gain and the phase of flame transfer function are closely associated with the flame length and structure, which is dependent upon the upstream flow perturbation as well as equivalence ratio in the current study.

  • PDF

이유체 선회분사 노즐의 액적크기에 관한 실험적 연구 (An Experimental Study on the Drop Size of a Twin-Fluid Swirl Jet Nozzle)

  • 오제하;김원태;강신재;노병준
    • 한국분무공학회지
    • /
    • 제1권1호
    • /
    • pp.21-27
    • /
    • 1996
  • This experimental study was to investigate spray angles and drop sizes in an external mixed twin-fluid swirl jet nozzle. Twin-fluid swirl jet nozzle with swirlers designed four swirl angles such as $0^{\circ},\;22.5^{\circ},\;45^{\circ},\;64.2^{\circ}$ was employed. A PDA system was utilized for the measurement of drop size and mean velocity. Water and air were used as the working fluids in this experiment. The mass flow rate of water was fixed as 0.03 kg/min, and air flow rates were controlled to have the air/liquid mass ratio from 1.0 to 6.0. As a result, swirl angle controlled to spray angles and drop sizes. It was found that swirl angle was increased with spray angle and with decreased SMD. However, the effect of swirl angle was reduced at large air/liquid mass ratio(Mr=6.0).

  • PDF

팬형분무의 주변조건에 따른 입자분포 변화 (The Droplet Size Distribution of Fan Spray at Different Surrounding Conditions)

  • 문석수;최재준;배충식
    • 대한기계학회논문집B
    • /
    • 제31권7호
    • /
    • pp.611-619
    • /
    • 2007
  • In this study, the droplet size distribution of a slit injector at different surrounding conditions, such as air flow and fuel temperature, were investigated. Phase Doppler anemometry (PDA) was utilized to investigate the initial droplet size distribution and the effect of fuel temperature and air flow on droplet size distribution. The entrained air motion was also evaluated by the temporal velocity profile of droplets. When the air flow velocity increased, the small droplets were more entrained to the upper and central parts of the spray and this tendency was confirmed by plotting the temporal velocity profile of droplets. This entrainment of small droplets at high airflow velocities caused relatively small mean droplet size at upper and central parts of the spray and the large mean droplet size at downstream and edge of the spray, compared to that of low airflow velocities. The total mean droplet size, obtained by averaging the size of all droplets measured at all test locations, decreased when the high airflow velocities were applied. The increased fuel temperature, with an airflow velocity of 10m/s, caused reduced droplet size at all test locations. However, the decreased value of mean droplet size at high fuel temperatures was relatively higher at upper parts of the spray, compared to downstream, as a result of enhanced entrainment of small droplets to upper parts of the spray.

Influence of spacing between buildings on wind characteristics above rural and suburban areas

  • Kozmar, Hrvoje
    • Wind and Structures
    • /
    • 제11권5호
    • /
    • pp.413-426
    • /
    • 2008
  • A wind tunnel study has been carried out to determine the influence of spacing between buildings on wind characteristics above rural and suburban type of terrain. Experiments were performed for two types of buildings, three-floor family houses and five-floor apartment buildings. The atmospheric boundary layer (ABL) models were generated by means of the Counihan method using a castellated barrier wall, vortex generators and a fetch of roughness elements. A hot wire anemometry system was applied for measurement of mean velocity and velocity fluctuations. The mean velocity profiles are in good agreement with the power law for exponent values from ${\alpha}=0.15$ to ${\alpha}=0.24$, which is acceptable for the representation of the rural and suburban ABL, respectively. Effects of the spacing density among buildings on wind characteristics range from the ground up to $0.6{\delta}$. As the spacing becomes smaller, the mean flow is slowed down, whilst, simultaneously, the turbulence intensity and absolute values of the Reynolds stress increase due to the increased friction between the surface and the air flow. This results in a higher ventilation efficiency as the increased retardation of horizontal flow simultaneously accompanies an intensified vertical transfer of momentum.

소형 액체로켓엔진 인젝터의 분무패턴 분석 (Spray Pattern Analysis of the Injector in a Small Liquid-Rocket Engine)

  • 정훈;김진석;김정수;박정;김성초;장기원
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.146-149
    • /
    • 2006
  • 단일액체추진제 하이드라진 추력기의 인젝터로부터 발생하는 분무 특성을 파악하기 위해 입자영상유속계 및 레이저 도플러 유속계 기법을 적용하였다. 입자영상유속계를 이용하여 순간 평면 이미지를 획득하고 이 영상 자료를 통해 압력에 따른 분무정도 및 인젝터 분무성능을 판단하였다. 영상 이미지에서 누락된 분무 입자의 속도 및 입경 계측을 위해 레이저 도플러 유속계 계측방법을 적용하였다. 계측된 두 실험결과를 비교함으로써 분무 특성에 대한 명확한 이해 뿐만 아니라 인젝터 설계 변수 도출이 본 연구의 목적이다.

  • PDF

원주상으로 배열된 원형 제트의 유동 측정 (Flow Measurements of Circular Jets Arrayed Circumferentially)

  • 진학수;김성초;김정수;최종욱
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.11-14
    • /
    • 2006
  • 본 연구에서는 열선풍속계를 이용하여 다중 제트 유동장을 측정하여 해석하였다. 노즐배열은 원주상에 등간격으로 배열되였으며, 중심에 노즐이 있거나 혹은 없는 두 가지 경우로 분류하였다. 두 가지 경우의 레이놀즈 수가 노즐 출구에서 약 $10^4$일 때, 평균 속도, 레이놀즈 응력 등을 측정하였다. Tollmien 의 이론 속도 분포식은 중심에 노즐이 있는 경우에서 노즐 출구로부터 약 48d인 지점에서 성립하였다. 최대속도 감소와 상호작용은 중심 노즐의 유무에 의존한다.

  • PDF

드럼형 회전연료노즐의 미립화 기구 및 분무특성 연구 (The Atomization Mechanism and Spray Characteristics of Drum Type Rotary Atomizer)

  • 이동훈;최현경;최성만;유경원;허환일
    • 한국추진공학회지
    • /
    • 제12권2호
    • /
    • pp.57-65
    • /
    • 2008
  • 가스터빈엔진에 적용할 수 있는 드럼형 회전연료노즐의 모델링을 통해 원심력이 충분한 연료분사압력을 발생시킴을 보였고, 회전연료분사의 미립화 현상에 대해 실험적으로 연구하였다. 회전연료분사의 미립화기구 및 분무특성을 이해하기 위하여 고속 회전연료노존 시험리그를 이용하여 $5,000\;{\sim}\;40,000rpm$의 영역에서 분무가시화와 PDA를 이용한 분무액적 측정을 실시하여 회전연료분무의 미립화 특징을 규명하고, 미립화성능 향상을 위해서는 회전속도증가를 통해 액적분열시점을 앞당기는 것이 중요함을 알았다.

직접분사방식 추력기 노즐오리피스로부터 발생하는 분무입자의 발달특성 (Evolutionary Feature of Spray Droplets Exiting from a Direct-Injection Type Thruster Nozzle-Orifice)

  • 김진석;정훈;김정수;박정;김성초
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2009
  • 직접분사방식 추력기 노즐오리피스로부터 분사되는 분무입자의 발달특성을 연구하기 위해 분무의 다양한 위치에서 평균속도, 직경, 그리고 부피유속과 같은 분무특성인자들을 측정한다. 실험 결과로부터, 고속의 큰 직경을 갖는 분무 입자들이 주변 공기로의 운동량 손실로 인해 하류로 이동함에 따라 저속의 작은 입자로 분열한다. 또, 분무 확산 및 분산에 의해 높은 부피유속의 영역이 반경방향으로 넓게 확장된다.

  • PDF