• Title/Summary/Keyword: anemometer

Search Result 329, Processing Time 0.03 seconds

Computer-Interfacing Development for Propeller-Anemometer

  • Saad, Nor Hayati;Janin, Zuriati;Piah, Ruhaidawati Mohd Ali
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.515-519
    • /
    • 2004
  • A Propeller-Anemometer is an instrument used specifically, to measure the wind speed. The accurate measurement of the wind speed is vitally important such required by any weather stations. In this research, the measurand of the instrumentation was the rotational speed of the propeller and the instrumentation result or output data was wind velocity. The speed measured was recorded digitally in the computer by using specific software. A specific sensor used to measure a variable by converting information of the variable (rotational speed of the propeller) into a dependent signal such as electrical signal in form of voltage. The development of Propeller-Anemometer involved few sets of instrumentation process and equipment. It included three major parts, mechanical, electronics and computer. The main instrumentation processes were physical and signal interfacing, signal conditioning, logic interfacing, data transmission to computer and processing the data. Generally, this paper presents the overall concept and design of Propeller-Anemometer Instrumentation. However, an emphasis was mainly in designing and building the interfacing system, hardware and software. Basically, for the first phase of the development, this project designed and built the RS232 terminal using Peripheral Interface Controller (PIC), PIC16F873. The hardware can be interfaced to computer or other compatible devices. This routine converted input voltage from the circuit to speed (velocity) and transmitted them afterwards to the target device by using the RS232 transmission protocol. This implementation implied a computer display as visual interface. For the purpose of this paper, RS232 data transmission was carried out using a Microsoft Visual Basic software routine.

  • PDF

Development of Easy Measurement Method of Orthogonal Triple-Sensor Hot-Wire Anemometer (삼직교 열선유속계의 간편한 측정법 개발)

  • Kim, Jin-Kwon;Kang, Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.85-92
    • /
    • 2000
  • Easy measurement method of orthogonal triple-sensor hot-wire anemometer is developed. Advantages of the new method is that it does not require either the exact orthogonality of the installed wires which cannot be kept during the probe manufacture and repair, nor the knowledge of the wire installation angles and the yaw and pitch coefficient of the wires. The new method introduced yaw and pitch calibration coefficients which are designed to increase monotonically with yaw and pitch angles. So the resulting calibration network is simple to recognize compared with that of the previously suggested calibration method. Verification experiments showed good accuracy and independency of the directional calibration on velocity.

Fabrication and Characteristics of Hot-film Anemometer (열박막 풍속계의 제작 및 특성)

  • Kim, Hyung-Pyo;Cho, Chan-Seob
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.190-195
    • /
    • 2000
  • The paper presents the constant temperature digital hot-film anemometer that measures easily a wind velocity at the indoor. The output is linearized using microprocessor and analog-to-digital converter, because the fourth root of the wind velocity is the output voltage of the sensor. The comparison result between fabricated and reference anemometer is less than ${\pm}2%$. In the range of air temperature of $23^{\circ}C{\sim}60^{\circ}C$, the error is about ${\pm}1%$ in wind velocity 10m/sec.

  • PDF

Seasonal Variations of $SO_2$Dry Deposition Velocity Obtained by Sonic Anemometer-Thermometer (초음파 풍속온도계를 이용한 $SO_2$건성침착속도의 계절변화 특징)

  • 이종범;박세영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.465-478
    • /
    • 1998
  • In this study, seasonal variations of the dry deposition velocity and deposition flux for the sulfur dioxide were analysed. The field observation was performed during one year (from November 1, 1995 to October 31, 1996) in Chunchon basin. The turbulence data were measured by 3-dimensional sonic anemometer/thermometer, and were estimated by mean meteorological data obtained at two heights (2.5 m and 10 m) of meteorological tower. Also, the estimation methods were evaluated by comparing the turbulence data. The results showed that the estimated dry deposition velocity and turbulence parameter such as uc and sensible heat flux using mean meteorological data were relatively similar to the sonic measurements, but all showed somewhat large differences. The dry deposition velocity was large in summer and small in winter mainly due to canopy resistance (rc). The major factor which affects diurnal variation of the velocity was aerodynamic resistance (rw). The SO2 dry deposition flux was large in winter and small in summer in Chunchon.

  • PDF

Research on Improvement of Performance of Anemometer Using PTC Thermistor (PTC 서미스터를 이용한 유속계의 성능향상에 관한 연구)

  • Yoon, Joon-Yong;Cho, Nahm-Gyoo;Kim, Jin-Rae;Sung, Nak-Won;Kim, Hwang-Jin
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.15-21
    • /
    • 2000
  • An anemometer employing the bulk PTC thermistor as the sensing element is investigated in this study. The numerical and experimental works are carried out to improve the sensitivity problem of the element by focusing fluid dynamics point of view. The typical shape of the sensing element has been used as a rectangular type, but this shape has a sensitivity problem because of flow separations on the sharp edge when the flow direction is different from that of the sensing element. In order to reduce the reading error, the installer has to be very careful about the flow direction. The reading error fluctuation by time as well as the sensitivity problem can be improved considerably through this study. It can be concluded that the small change of the sensor shape can improve the performance of the flow sensor.

  • PDF

A Wind Tunnel Study on Influences of ILS Tower on Wind Speed Measurement (계기착륙장치 타워가 풍속관측에 미치는 영향에 관한 풍동실험연구)

  • Choi, Cheol-Min;Kim, Kye-Hwan;Kim, Young-Chul;Kwon, Kybeom
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.513-517
    • /
    • 2013
  • In this study, it is first intended to simulate the vertical profile of atmospheric flow in a short wind tunnel. In order to accomplish it, proper devices are designed properly to reduce freestream flow momentum and it is confirmed from the measured velocity profile using hot-wire anemometer that momentum flux of the tunnel free stream can be reduced and desired atmospheric boundary can be created. Second, experiments are performed to identify influences of a surrounding structure measuring correct wind velocity by an anemometer, which are located nearby due to area limitation in actual airport and correction factors are proposed from experimental results. One of findings is that in order to limit the velocity attenuation due to a nearby structure under 10%, wind velocity measuring equipment should be installed at least 6 times of the structure height away from the structure of concern.

Measurements of Turbulent Flows in the $180^{\circ}$ Curved Duct by Hot-wire Anemometer (열선유속계를 이용한 $180^{\circ}$ 곡덕트 내 난류유동의 측정)

  • Han, Seong-Ho;Kim, Won-Kap;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.729-734
    • /
    • 2003
  • This paper reports the characteristics of the three dimensional turbulent flow in the rectangular-sectioned 180 degree bends by Hot-wire anemometer. Grande and Kool proposed a cooling law for the measurements of the flow through the narrow passage. The authors noticed that the calibration coefficients of original method are not constant and fairly sensitive to the flow approaching angle. Measured voltages are converted to three velocity and six Reynolds stress components using the modified method in which the coefficients are treated as a function of approaching angle.

  • PDF

Characterization of three-dimensional ultrasonic anemometer using phase measurement (위상측정방식을 이용한 3차원 초음파 풍향풍속계의 특성분석)

  • Park, Do-Hyun;Yeh, Yun-Hae
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.442-448
    • /
    • 2006
  • Ultrasonic anemometers using pulse envelope detection-based method are standard instruments in most meteorological studies. In this paper, a new phase measurement method is tried to achieve the enhanced resolution without changing dimensions. The measurement sensitivity, dynamic range, and measurement speed of the new instrument are 0.2 mm/s, 13.3 m/s, and 13 measurements/sec, respectively. A graphic user interface is added to show the velocity and direction of the wind with the speed of sound and temperature of the wind in the 3 dimensional space. The new anemometer could be useful for the measurement of the air speed, the flow of fluids, and even air flow inside the downtown buildings.

Temperature Compensation of Hot-Wire Anemometer with Photoconductive Cell (광도전성저항을 이용한 열선유속계의 온도보상)

  • Lee, Sin-Pyo;Go, Sang-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.295-303
    • /
    • 1996
  • A new temperature compensation technique for hot-wire anemometer is proposed in this article. In contrast to the available compensation techniques, a photoconductive cell is introduced here as a variable resistor in the bridge. The major advantage of adopting an active component such as photoconductive cell is that temperature compensation can be achieved by using any kind of temperature sensors, once the output of temperature sensor is given as a voltage. Thereby, the temperature compensation can be made automatically and intelligently by a computer software or a hardware device. Validation experiments using a photoconductive cell with a thermocouple-thermometer are conducted in the temperature range from 3$0^{\circ}C$ to 5$0^{\circ}C$ and the velocity ranges from 8 m/s to 18 m/s.

Load Ratio between Two Adjacent Wings of Load Cell Type Anemometer according to Wind Direction (풍향에 따른 로드 셀형 풍향풍속계의 인접한 두 날개 사이의 하중 비)

  • Han, Dong-Seop
    • Journal of Navigation and Port Research
    • /
    • v.36 no.5
    • /
    • pp.357-361
    • /
    • 2012
  • Anemometer is a meteorological instrument that measures wind direction and wind speed in real time, and is mounted to the cranes that are used at ports, shipbuilding yards, off-shore structure, or construction sites that are influenced by wind, and it is used in conjunction with the safety system. Load cell-type anemometer measures the wind direction through the ratio of load between 4 positions by mounting the thin plate to 4 load cells, and measures wind velocity through the summation of loads. In this study, we compared and analyzed the results in the theoretic approach, analytic approach and experimental approach to derive the correlation between load ratio and wind direction. Wind direction was selected as the design variable, and selected 9 wind direction conditions from $0^{\circ}{\sim}90^{\circ}$ with $11.25^{\circ}$ space for analysis, and 10 wind direction conditions with $10^{\circ}$ space for experiment.