• 제목/요약/키워드: and strain gauge

검색결과 552건 처리시간 0.025초

캔틸레버의 길이와 하중이 하악 임플랜트지지 고정성 보철물의 응력 분산에 미치는 영향 (EFFECT OF CANTILEVER LENGTH AND LOAD ON STRESS DISTRIBUTION OF FIXED IMPLANT-SUPPORTED PROSTHESES)

  • 태윤섭;이화영;조혜원
    • 대한치과보철학회지
    • /
    • 제36권4호
    • /
    • pp.615-643
    • /
    • 1998
  • The purpose of this study was to evaluate the effect of cantilever length, load, and implant number on the stress distribution of implant supported fixed prosthesis. In the replica of an edentulous human mandible, four or five implants were placed and spaced evenly between the mental foramina and symmetrical gold alloy cast superstructures with cantilever were fabricated. Strain gauges were placed in buccal and lingual side of implants. 9, 15, 21kg of loads at varying cantilever lengths were applied to the occlusal surface of fixed prostheses. The strains were recorded from each gauge and principal stresses were calculated The results were as follows : 1. Increasing the length of the cantilever increased the stresses on the bone supporting implants. and the ratio of increase became high as increasing the load. 2. In the model with four implants, the highest compressive stress was measured on lingual side of the first implants nearest loading point and the highest tensile stress was measured on buccal side of the second implants. 3. In the model with five implants, the highest compressive stress was measured on lingual side of the first implants nearest loading point. And the highest tensile stress was measured on buccal side of the second implants, and lingual side of the third implants. 4. There was no significant change of the magnitude of stress on the most distal imp]ant of non cantilevered side as increasing the cantilever length or load. 5. In general, the superstructure supported by five implants reduced the stress and was less affected by cantilever length compared to the support provided by four implants.

  • PDF

횐쥐 대동맥의 수축반응과 열충격단백질에 대한 비소의 영향 (Effect of Arsenic on Heat Shock Protein and Vascular Contractility of Rat Aorta)

  • 박태규;권윤정;김중영
    • 한국환경과학회지
    • /
    • 제12권6호
    • /
    • pp.651-657
    • /
    • 2003
  • In order to examine if arsenic, one of environmental stresses, contributes to hypertension as one of cardiovas cular pathological factors, this study was perfarmed in vivo and in vitro, using intacted or pithed rats and aorta ring preparation, respectively. And also the relationship between expression of heat shock protein (HSP) 90 and vasoactives-induced contractile response was elucidated. To measure blood pressure, the carotid arterial pressure was recorded on physiograph(Grass Co. 79E) connected to strain gauge. On the other hand, contractile response of vascular ring preparation isolated from rat was determined in organ bath and was recorded on physiograph connected to isometric transducer. And HSP was detacted by Western blotting whole cell Iysis. Preganglionic nerve stimulation was increased by 26.0% in arterial pressure of rat treated with arsenic. Vascular contractile response was monitored and HSP were measured by Western blotting of whole Iysis prepared from samples exposed with 0, 0.5, 1, 2 and 4 mM of arsenic for 8 hours. The dose-vascular responses of potassium chloride were augmented by increasing dose of arsenic in the strips exposed to arsenic for 8 hours, and were not augmented for 1, 3, 5 hours. And the response of relaxation of rat aorta induced by histamine was not influenced by arsenic stress. The increase of HSP 90 expression in rat aorta was pronounced at 8 hours after 4 mM of arsenic treatment, but HSP 60 expression was not. Arsenic stress not only increased the expression of HSP 90 in the rat aorta, but also augmented contractions to potassium chloride. These results indicated that arsenic stress was sufficient to induce heat shock protein 90, resulting in increased vascular contractility in rat aorta.

그래핀 기반 지능형 나노복합소재를 이용한 고감도 임팩트 페인트 센서 개발 연구 (Development of Novel Impact Paint Sensor by Using Graphene based Smart Nano Composite)

  • 김성용;박세훈;최경락;박형기;강인필
    • 한국소음진동공학회논문집
    • /
    • 제24권3호
    • /
    • pp.247-252
    • /
    • 2014
  • This paper presents a novel impact sensor which can be fabricated with smart paint made of grapheme. This smart nano paint can be easily installed on structures using a spray-on technique and that can make the sensor low cost and practical. The graphene effectively improves the piezoresistivity of the smart paint and that is available to achieve sensitive impact sensor with high gauge factor. The nano smart-paint can detect sufficient impact to cover the damaged energy range of the composite around 1~3J. The voltage outputs from the sprayed paints show fairly linear responses after signal processing. The impact makes deformation of the structure and it brings change of piezoresistivity of the paint and those converts into voltage output consequently by means of a simple signal processing system. The nano smart paint is lightweight and easily applied to the structural surface, and there is no stress concentration. The nano smart paint is expected to be a cost effective and sensitive multi-functional sensor for composites and other damage monitoring applications in the field of structural health monitoring.

마이크로 컴퓨터를 이용한 식품가공(食品加工) 공정중(工程中)의 온도및 무게 측정용(測定用) Analog-digital 변환(變換)및 접속(接續) 시스템의 제작(製作) (Microcomputer-based Data Acquisition System for the Measurements of Temperature and Weight in Food Processing)

  • 최부돌;전재근
    • 한국식품과학회지
    • /
    • 제19권2호
    • /
    • pp.129-133
    • /
    • 1987
  • 마이크로컴퓨터를 식품가공 공정및 연구에서 자료수집및 제어에 응용하기 위하여 Apple ll 컴퓨터에 접속가능한 접속장치(接續裝置)를 설계 제작하였다. 또한 식품의 여러 공정에 주요한 변수가 되는 온도 및 무게값을 전기적 신호로 감지하는 센서와 A/D변환기(變換器)의 적정 입력전압범위 전환을 위한 증폭회로를 구성하였다. 이들을 연결시켜 필요한 BASIC어(語) 프로그램을 작성하여 식품건조 장치의 온도및 무게값의 측정장치로 활용 가능함을 보였다. 컴퓨터를 응용함으로써 공정자료의 정확성과 신뢰성을 향상시키고 여러가지 공정변수를 다량 수집할 수 있게되고 수집된 많은 자료를 용이하게 저장, 분석할 수 있었다. 본 실험장치에 여러가지 목적에 따라 필요한 측정 센서를 개발하여 부착(附着)함으로 비단 온도와 무게 측정뿐 아니라 제반(諸般)식품(食品)제조 공정과 실험의 자동화에 활용할 수 있는 기초적인 자료를 얻었다.

  • PDF

로타리 경운작업 시 트랙터 PTO 가혹도 평가 (Evaluation of Tractor PTO Severeness during Rotary Tillage Operation)

  • 김용주;정선옥;최창현;이대현
    • Journal of Biosystems Engineering
    • /
    • 제36권3호
    • /
    • pp.163-170
    • /
    • 2011
  • Analysis of load on major parts of the tractor power drive line is critical for efficient and optimum design of a tractor. The purpose of this study was to evaluate severeness of the tractor PTO driving axle during rotary tillage operation. First, S-N (stress vs. number of cycle) curve of a PTO driving gear was obtained through the fatigue life test using a PTO dynamometer. Second, PTO severeness was evaluated during rotary tillage operation. Torque measurement system was constructed with strain-gauge sensors to measure torque of a PTO axle, an I/O interface to acquire the sensor signals, and an embedded system to calculate severeness. The severeness of PTO was analyzed using measured torque data during rotary tillage. In the PTO gear life fatigue test, breakage time and bending stress of the gear were measured by tooth widths and torque change during the fatigue life test. The S-N curve showed a good linear relationship between bending stress and number of cycle (life) with a coefficient of determination of 0.97. For PTO severenss evaluation, rotary tillage operations were conducted at two PTO rotational speeds (level-1, level-2) under different paddy and upland field sites with different soil conditions. Results of averaged relative severeness for PTO level-1 and PTO level-2 were 1.96 and 3.34, respectively, at paddy field sites, and they were 1.36 and 2.51, respectively, at upland field sites. The results showed that the PTO driving axle experienced more severe load during rotary tillage at paddy fields than at upland sites, and relative severeness was greater at the higher PTO rotational speed under all of the soil conditions.

편측 후방 치아 잔존시 의치 설계에 따른 지대치지지 조직과 잔존 치조제의 응력 분석에 관한 연구 (STRESS ANALYSIS AT SUPPORTING TISSUE OF ABUTMENT TEETH AND RESIDUAL RIDGE ACCORDING TO DENTURE DESIGN WITH REMAINING UNILATERAL POSTERIOR TEETH)

  • 안광호;정영완;진태호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.185-199
    • /
    • 1999
  • This study was peformed to investigate the distribution and magnitude of stress at supporting tissue of abutment teeth and residual ridge tissue with remaining unilateral posterior teeth. Four types of removable partial dentures that included clasp retained removable partial denture, attachment retained removable partial denture, telescopic removable partial denture, and swing-lock partial denture were designed, and strain gauge was used for stress analysis. Each prosthesis was subjected to simulated vertical and oblique load. The following conclusions were drawn from this study. 1. The clasp retained removable partial denture generally distributed simulated vertical force more evenly to the supporting structure. 2. The stress at buccal side of 1st premolar was the lowest in swing-lock partial denture and that was highest in attchment retained removable partial denture. The stress at lingual side of 1st premolar was the lowest in telescopic partial denture. 3. In clasp retained removable partial denture, stress was lower at load site and ridge crest at mid-line, but it was higher at 1st premolar area on vertical load. 4. In attachment removable partial denture, stresses at buccal side of 1st premolar. lingual side of 1st premolar on vertical load, and ridge crest at midline on oblique load were higher. 5. In telescopic removable partial denture, stress at lingual side of 1st premolar was the least in all removable partial dentures, but the stress at load site was higher. 6. In swing-lock removable partial denture, stress at buccal side of 1st premolar was the lowest, and stresses at load site and distal end of residual ridge crest were higher.

  • PDF

진동가속도계의 주파수응답특성 개선에 관한 연구 (Study on improvement of frequency response characteristics of accelerometer)

  • 한응교;조진호
    • 오토저널
    • /
    • 제3권1호
    • /
    • pp.61-68
    • /
    • 1981
  • There are three types in frequency response accelerometer; one is lightly damped piezp type, another is oil damping stainguage type and the third is electro induction type accelerometer within electromagnetic damping. The usable frequency range of lightly damped accelerometers is limited to 0.2 of their mounted natural frequency for amplitude distortion of less than 5 percents. There have been situation where the measured motion contains unforeseen high - frequency components, which are regarded as such due to the accelerometer transfer function. There are several way to overcome amplitude distortion of the higher than anticipated frequency components; (I) to make use of the accelerometer with natural frequency three times and more as high as the measured frequency, (II) to establish data-analysis techniques which will account for the amplitude distortion, (III) to set up a notch filter circuit which has a transfer function that is the reciprocal of the accelerometer transfer function, and so on. This paper makes a report of the method as to(III), i. e., set up a few notch filter circuits, it is discussed what happens when the transfer functions, are in discord as to natural frequency of the filter and accelerometer damping vs. filter damping. And especially as for the cantilever strain gauge type accelerometer made by oneself with ease, it was compared and discussed between the ideological value and the experimental value of actual designed circuit in case of the mismatching of the transfer functions, and it was considered whether to be practicable or not, the result of which was as following; the useful frequency range of the accelerometer can be extended to near resonance if (a) the accelerometer mounted natural frequency and the filter center frequency are matched within .+-. 2 percent and (b) the damping ratios are matched within two factors. Therefore, we obtained the good result in improvement for extending frequency response characteristics of accelerometer.

  • PDF

공작기계용 접촉식 측정 프로브의 프로빙 오차 보상에 관한 연구 (Touch-Trigger Probe Error Compensation in a Machining Center)

  • 이찬호;이응석
    • 대한기계학회논문집A
    • /
    • 제35권6호
    • /
    • pp.661-667
    • /
    • 2011
  • 접촉식 측정 프로브는 3 차원 좌표 측정기 및 CNC 공작기계 등에서 제품 검사에 많이 활용되고 있고, 최근 품질 향상을 위한 가공 및 검사장비의 고정도화에 따라 측정의 정확도도 또한 매우 중요시 되고 있다. 이에 따라 스트레인 게이지 등을 이용한 고정도의 측정 프로브가 사용되고 있기는 하지만, 본 연구에서는 경제적인 측면을 고려하여 산업현장에서 공작기계에 많이 활용되는 일반 접촉식 측정 프로브의 메커니즘을 이해하고, 측정 시 발생할 수 있는 프로빙 오차에 대한 분석 및 보정을 통하여 그 활용성을 높이고자 하였다. 이를 위하여 스타일러스 반경 및 중심 정렬오차가 규명되었고, 3 차원 공간상의 측정 좌표에서 프로빙 오차에 대한 해석이 이루어졌다. 이러한 오차들을 보정하기 위한 알고리즘이 개발되었으며, 실제 CNC 공작기계 상에서 기준구 측정을 통한 검증이 이루어졌다.

전진 비행하는 Quad-Tilt Propeller 형상 무인기 날개에서 나타나는 공력간섭 현상에 대한 실험적 연구 (A Experimental Study of Aerodynamic Interference on Quad-Tilt Propeller UAV Wings in Forward Flight Condition)

  • 김태우;정진덕;김양원;박철완;조태환
    • 한국항공우주학회지
    • /
    • 제47권2호
    • /
    • pp.81-89
    • /
    • 2019
  • 본 연구는 쿼드 틸트 프로펠러(Quad Tilt Propeller)형상의 탠덤날개 항공기의 전진비행 조건을 풍동실험하여 전방 날개 및 프로펠러가 후방날개에 작용하는 공력 간섭효과를 분석하였다. 6축 밸런스시스템을 이용해 전기체의 힘을 측정하였고 날개뿌리에 부착된 스트레인게이지를 이용하여 각 날개의 굽힘모멘트를 측정하였다. 12홀 프로브를 이용해 날개 및 프로펠러 후류의 유동장을 측정하였으며, 털실과 스모크를 이용한 유동가시화 실험을 통해 유동 특징을 정성적으로 확인하였다. 요소별 공력간섭 현상을 측정하기 위해 프로펠러 부착 조합을 바꿔가며 전방날개와 프로펠러가 후방날개에 작용하는 영향을 분석하였다.

건조수축에 따른 균열 억제를 위한 규사 혼입 CLC의 특성 (Properties of CLC using Silica to Suppress Cracking due to Drying Shrinkage)

  • 이창우;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.125-126
    • /
    • 2021
  • In order to improve the housing culture, construction changes for the utilization of diverse and multifunctional spaces are appearing in response to the increasing diverse needs of consumers. Cellular Light-weight Concrete (CLC) is being developed for use in fire-resistant heat-insulating walls and non-bearing walls. However, manufacturing non-uniformity has become a problem as a drawback due to the use of foamed bubbles and normal temperature curing, and additional research is required. Therefore, in order to suppress cracks due to drying shrinkage, silica sand is mixed with CLC to try to understand its characteristics. In the experiment, the compressive strength from 7 to 28 days of age was measured via a constant temperature and humidity chamber, and the drying shrinkage was analyzed according to each condition using a strain gauge. The compressive strength of matrix tends to decrease as the substitution rate of silica sand increases. This is judged by the result derived from the fact that the specific surface area of silica sand is smaller than that of slag. Based on KS F 2701 (ALC block), the compressive strength of 0.6 products is 4.9 MPa or more as a guide, so the maximum replacement rate of silica sand that satisfies this can be seen at 60%. Looking at the change in drying shrinkage for just 7 days, the shrinkage due to temperature change and drying is 0.7 mm, and the possibility of cracking due to shrinkage can be seen, and it seems that continuous improvement and supplementation are needed in the future.

  • PDF