• 제목/요약/키워드: and resonance

검색결과 10,602건 처리시간 0.032초

Double Resonance Spectra Involving Torsional Excited Levels and CO Stretch Band Transitions of $CD_3OH$

  • Choi, Sung-Eul
    • 한국광학회지
    • /
    • 제6권2호
    • /
    • pp.165-171
    • /
    • 1995
  • Infrared-Radio frequency double resonance (IRRFDR) and Infrared-Microwave double resonance (IRMWDR) spectroscopy have been used to probe a level of A symmetry for $CD_{3}$OH. Double resonance spectra of $CD_{3}$OH have been investigated over the range of 940 to 1020 $cm ^{-1}$ . Twenty K-type doublet transitions have been observed in both the radio frequency region, which covers 50 MHz to 1 GHz, and the microwave region, which covers 8 GHz to 12 GHz. The results propose new assignments of infrared (IR) absorption transitions and far-infrared (FIR) laser emission lines. These involve torsional excited levels and CO stretch states. Measurements of the A state splitting have permitted the determination of the asymmetry splitting parameters $S^{o}$(n, K) and $^{co}$ (n, K) for (n, K)=(0.3) and (1.3)

  • PDF

Detailed Study on Insulation Coordination of a 25kV Power System Connected with a VCB and Transformer

  • Baek, Byung-San;Kim, Yong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1245-1249
    • /
    • 2017
  • Recently, unusual transformer failures have been reported in 25kV power systems connected with a VCB and transformer. In this study, performance of the protection system, dielectric strength of the transformers, characteristics of switching surges and resonance phenomena were analysed and assessed. All investigations regarding the insulation breakdown of the transformers were carried out by simulations, laboratory tests, factory tests and on-site measurements in order to thoroughly investigate the root causes. Furthermore, experimental methods for investigating the resonance phenomenon were derived and tests were conducted applying the derived method to recreate the phenomenon in the transformer. It is found that resonance between the transformer and switching surge generated by closing a VCB can initiate the breakdown of internal windings of a transformer.

Current Status of Magnetic Resonance Imaging in Patients with Malignant Uterine Neoplasms: A Review

  • Yu-Ting Huang;Yen-Ling Huang;Koon-Kwan Ng;Gigin Lin
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.18-33
    • /
    • 2019
  • In this study, we summarize the clinical role of magnetic resonance imaging (MRI) in the diagnosis of patients with malignant uterine neoplasms, including leiomyosarcoma, endometrial stromal sarcoma, adenosarcoma, uterine carcinosarcoma, and endometrial cancer, with emphasis on the challenges and disadvantages. MRI plays an essential role in patients with uterine malignancy, for the purpose of tumor detection, primary staging, and treatment planning. MRI has advanced in scope beyond the visualization of the many aspects of anatomical structures, including diffusion-weighted imaging, dynamic contrast enhancement-MRI, and magnetic resonance spectroscopy. Emerging technologies coupled with the use of artificial intelligence in MRI are expected to lead to progressive improvement in case management of malignant uterine neoplasms.

Foramen transversarium enlargement caused by vertebral artery tortuosity: Diagnosis with cone-beam computed tomography and magnetic resonance angiography

  • Omami, Galal
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.329-332
    • /
    • 2021
  • A markedly enlarged foramen transversarium was discovered incidentally on a cone-beam computed tomography scan of a 72-year-old male patient who was referred for dental implant placement. Further evaluation with magnetic resonance angiography revealed that the foramen enlargement was caused by a tortuosity in the course of the vertebral artery. This case report highlights the importance of recognizing significant incidental findings on diagnostic images and the potential need for additional imaging as part of the complete interpretative process.

척추의 확산강조 자기공명영상 (Diffusion-Weighted Magnetic Resonance Imaging of Spine)

  • 윤영철
    • 대한영상의학회지
    • /
    • 제81권1호
    • /
    • pp.58-69
    • /
    • 2020
  • 척추영상에 사용되는 확산강조영상의 기술적 측면, 양성과 악성 척추체 압박골절의 구분, 다발성골수종이나 전이암의 발견과 감별진단, 그리고 항암화학요법이나 방사선치료 후 반응 평가에 대해 기술하고자 한다.

LC공진을 이용한 원격측정용 압력센서의 제작 및 실험 (A Telemetry Silicon Pressure Sensor of LC Resonance Type)

  • 김학진;김순영;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1872-1874
    • /
    • 2001
  • This paper presents an implantable telemetry LC resonance-type pressure sensor to measure the cerebral ventricle pressure. The sensor consists of an inductor and a capacitor. The LC resonant circuit consists of the sensor and an external antenna coil that are coupled magnetically. The resonance frequency of the circuit decreases as the applied pressure increases the capacitance of the sensor. The sensor is designed in consideration of the biocompatibility and long lifetime for continuous monitoring of the ventricle pressure. The sensor is simple to fabricate and small in comparison with others reported previously. The inductor is fabricated by electroplating and the variable capacitor is constructed with a flexible p+ diaphragm. Also, the deflection of the diaphragm, the variation of the capacitance and the resonance frequency are analyzed and calculated.

  • PDF

1[MHz] 대역의 자계 공명을 이용한 무선 전력 전송 장치에 관한 연구 (A Study on the Wireless Power Transfer System using Magnetic Resonance at the 1[MHz] Frequency Band)

  • 박정흠
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.75-81
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed, analyzed by circuit analysis methode and the calculated transfer function was compared with the measured one. The self-resonant coil was made up of the commonly used capacitor which had the lumped capacitance and it enabled the stable magnetic resonance not to be affected by the circumstance. The transmission efficiency of this system was 70[%] at the 15[cm] between the transmission and receiving coil and the measured transfer function was similar to the calculated one, which means the circuit analysis methode is valid in this system. When the intermediate coils were added between the transmission and receiving coil, the transmission efficiency was increased, which produced the increase of transfer distance. In the case of the five intermediate coils adding, the 35[%] transmission efficiency was achived at the 90[cm] distance.

Extranodal Malignant Lymphoma Concurrent Involving Female Urethra and Cervix: a Case Report

  • Kim, Dong Chan;Kim, You Me
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.168-173
    • /
    • 2020
  • Extranodal lymphoma presents in almost one-third of all non-Hodgkin lymphoma cases. The gastrointestinal tract, skin, and central nervous system are common sites of involvement, whereas the urethra and cervix are very rare. To the best of our knowledge, this is the first report on concurrent extranodal involvement of the uterine cervix and urethra. We report imaging findings of malignant lymphoma involving urethra and cervix concurrently in a 79-year-old female patient with literature review. The magnetic resonance imaging showed huge intermediate to high signal intensity mass on T2 weighted images and strong homogeneous enhancement in uterine cervix and periurethral area, but no surrounding architectural disruption.

Mode Identification in the Design of Wideband Cylindrical Monopole Antenna

  • Chun, Joong-Chang;Kim, Sang-Youl;Jeung, Deuk-Soo
    • Journal of information and communication convergence engineering
    • /
    • 제7권3호
    • /
    • pp.263-267
    • /
    • 2009
  • Cylindrical monopole antenna is one of most promising candidates for multi-band applications such as PCS, WLAN, DMB, and UWB wireless services. In this research, we demonstrate that there exist two types of current distributions according to the exciting frequency in a double band cylindrical monopole antenna, in which double resonance is achieved by adjusting the coupling structure of the antenna base. The operating modes of current distributions are identified from CST software simulations, the standing wave mode in a lower band and the traveling wave mode in a higher band. Also it is noticed that the mode behavior is quite similar to a helical antenna, a standing-wave (resonance) mode and a traveling-wave (non-resonance) mode according to the electrical dimensions of antenna. The effective ranges for operating modes and design formulas of the double band antenna are derived from simulation and measured results.

대칭-비대칭 공진모드를 이용한 초음파 리니어 모터의 구동특성 연구 (A Study on The Driving Characteristics of Ultrasonic Linear Motor Using Symmetric And Anti-Symmetirc Resonance Modes)

  • 최명일;배석명;박태곤
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1962-1966
    • /
    • 2007
  • Transducer for ultrasonic linear motor with the symmetric and anti-symmetric modes was studied. The ultrasonic linear motor consists of two Langevin type piezoelectric vibrators that cross at right angles with each other in tip. In order to excite symmetric and anti-symmetric resonance modes, the transducer must have a phase shift of 90 degree in space and time. Therefore, the tip of transducer moves on an elliptical motion. In this paper, the finite element analysis was used to optimize dimension and displacement of the transducer. The ultrasonic motor was fabricated using the simulated result and the driving characteristics were measured. No-load velocity was 0.28[m/s] and the maximum efficiency was 30[%] in resonance frequency.