• Title/Summary/Keyword: and materials

Search Result 98,182, Processing Time 0.134 seconds

Radioimmunoassay Reagent Survey and Evaluation (검사별 radioimmunoassay시약 조사 및 비교실험)

  • Kim, Ji-Na;An, Jae-seok;Jeon, Young-woo;Yoon, Sang-hyuk;Kim, Yoon-cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.34-40
    • /
    • 2021
  • Purpose If a new test is introduced or reagents are changed in the laboratory of a medical institution, the characteristics of the test should be analyzed according to the procedure and the assessment of reagents should be made. However, several necessary conditions must be met to perform all required comparative evaluations, first enough samples should be prepared for each test, and secondly, various reagents applicable to the comparative evaluations must be supplied. Even if enough comparative evaluations have been done, there is a limit to the fact that the data variation for the new reagent represents the overall patient data variation, The fact puts a burden on the laboratory to the change the reagent. Due to these various difficulties, reagent changes in the laboratory are limited. In order to introduce a competitive bid, the institute conducted a full investigation of Radioimmunoassay(RIA) reagents for each test and established the range of reagents available in the laboratory through comparative evaluations. We wanted to share this process. Materials and Methods There are 20 items of tests conducted in our laboratory except for consignment tests. For each test, RIA reagents that can be used were fully investigated with the reference to external quality control report. and the manuals for each reagent were obtained. Each reagent was checked for the manual to check the test method, Incubation time, sample volume needed for the test. After that, the primary selection was made according to whether it was available in this laboratory. The primary selected reagents were supplied with 2kits based on 100tests, and the data correlation test, sensitivity measurement, recovery rate measurement, and dilution test were conducted. The secondary selection was performed according to the results of the comparative evaluation. The reagents that passed the primary and secondary selections were submitted to the competitive bidding list. In the case of reagent is designated as a singular, we submitted a explanatory statement with the data obtained during the primary and secondary selection processes. Results Excluded from the primary selection was the case where TAT was expected to be delayed at the moment, and it was impossible to apply to our equipment due to the large volume of reagents used during the test. In the primary selection, there were five items which only one reagent was available.(squamous cell carcinoma Ag(SCC Ag), β-human chorionic gonadotropin(β-HCG), vitamin B12, folate, free testosterone), two reagents were available(CA19-9, CA125, CA72-4, ferritin, thyroglobulin antibody(TG Ab), microsomal antibody(Mic Ab), thyroid stimulating hormone-receptor-antibody(TSH-R-Ab), calcitonin), three reagents were available (triiodothyronine(T3), Tree T3, Free T4, TSH, intact parathyroid hormone(intact PTH)) and four reagents were available are carcinoembryonic antigen(CEA), TG. In the secondary selection, there were eight items which only one reagent was available.(ferritin, TG, CA19-9, SCC, β-HCG, vitaminB12, folate, free testosterone), two reagents were available(TG Ab, Mic Ab, TSH-R-Ab, CA125, CA72-4, intact PTH, calcitonin), three reagents were available(T3, Tree T3, Free T4, TSH, CEA). Reasons excluded from the secondary selection were the lack of reagent supply for comparative evaluations, the problems with data reproducibility, and the inability to accept data variations. The most problematic part of comparative evaluations was sample collection. It didn't matter if the number of samples requested was large and the capacity needed for the test was small. It was difficult to collect various concentration samples in the case of a small number of tests(100 cases per month or less), and it was difficult to conduct a recovery rate test in the case of a relatively large volume of samples required for a single test(more than 100 uL). In addition, the lack of dilution solution or standard zero material for sensitivity measurement or dilution tests was one of the problems. Conclusion Comparative evaluation for changing test reagents require appropriate preparation time to collect diverse and sufficient samples. In addition, setting the total sample volume and reagent volume range required for comparative evaluations, depending on the sample volume and reagent volume required for one test, will reduce the burden of sample collection and planning for each comparative evaluation.

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.

Radiation Dose-escalation Trial for Glioblastomas with 3D-conformal Radiotherapy (3차원 입체조형치료에 의한 아교모세포종의 방사선 선량증가 연구)

  • Cho, Jae-Ho;Lee, Chang-Geol;Kim, Kyoung-Ju;Bak, Jin-Ho;Lee, Se-Byeoung;Cho, Sam-Ju;Shim, Su-Jung;Yoon, Dok-Hyun;Chang, Jong-Hee;Kim, Tae-Gon;Kim, Dong-Suk;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.237-246
    • /
    • 2004
  • Purpose: To investigate the effects of radiation dose-escalation on the treatment outcome, complications and the other prognostic variables for glioblastoma patients treated with 3D-conformal radiotherapy (3D-CRT). Materials and Methods: Between Jan 1997 and July 2002, a total of 75 patients with histologically proven diagnosis of glioblastoma were analyzed. The patients who had a Karnofsky Performance Score (KPS) of 60 or higher, and received at least 50 Gy of radiation to the tumor bed were eligible. All the patients were divided into two arms; Arm 1, the high-dose group was enrolled prospectively, and Arm 2, the low-dose group served as a retrospective control. Arm 1 patients received $63\~70$ Gy (Median 66 Gy, fraction size $1.8\~2$ Gy) with 3D-conformal radiotherapy, and Arm 2 received 59.4 Gy or less (Median 59.4 Gy, fraction size 1.8 Gy) with 2D-conventional radiotherapy. The Gross Tumor Volume (GTV) was defined by the surgical margin and the residual gross tumor on a contrast enhanced MRI. Surrounding edema was not included in the Clinical Target Volume (CTV) in Arm 1, so as to reduce the risk of late radiation associated complications; whereas as in Arm 2 it was included. The overall survival and progression free survival times were calculated from the date of surgery using the Kaplan-Meier method. The time to progression was measured with serial neurologic examinations and MRI or CT scans after RT completion. Acute and late toxicities were evaluated using the Radiation Therapy Oncology Group neurotoxicity scores. Results: During the relatively short follow up period of 14 months, the median overall survival and progression free survival times were $15{\pm}1.65$ and $11{\pm}0.95$ months, respectively. The was a significantly longer survival time for the Arm 1 patients compared to those in Arm 2 (p=0.028). For Arm 1 patients, the median survival and progression free survival times were $21{\pm}5.03$ and $12{\pm}1.59$ months, respectively, while for Arm 2 patients they were $14{\pm}0.94$ and $10{\pm}1.63$ months, respectively. Especially in terms of the 2-year survival rate, the high-dose group showed a much better survival time than the low-dose group; $44.7\%$ versus $19.2\%$. Upon univariate analyses, age, performance status, location of tumor, extent of surgery, tumor volume and radiation dose group were significant factors for survival. Multivariate analyses confirmed that the impact of radiation dose on survival was independent of age, performance status, extent of surgery and target volume. During the follow-up period, complications related directly with radiation, such as radionecrosis, has not been identified. Conclusion: Using 3D-conformal radiotherapy, which is able to reduce the radiation dose to normal tissues compared to 2D-conventional treatment, up to 70 Gy of radiation could be delivered to the GTV without significant toxicity. As an approach to intensify local treatment, the radiation dose escalation through 3D-CRT can be expected to increase the overall and progression free survival times for patients with glioblastomas.

The Effect of Interferon-γ on Bleomycin Induced Pulmonary Fibrosis in the Rat (Interferon-γ 투여가 쥐에서의 Bleomycin 유도 폐 섬유화에 미치는 영향)

  • Yoon, Hyoung Kyu;Kim, Yong Hyun;Kwon, Soon Seog;Kim, Young Kyoon;Kim, Kwan Hyung;Moon, Hwa Sik;Park, Sung Hak;Song, Jeong Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.1
    • /
    • pp.51-66
    • /
    • 2004
  • Objectives : The matrix metalloproteinases (MMPs) that participate in the extracellular matrix metabolism play a important role in the progression of pulmonary fibrosis. The effects of the MMPs are regulated by several factors including Th-1 cytokines, $interferon-{\gamma}$ ($IFN-{\gamma}$). Up to now, $IFN-{\gamma}$ is known to inhibit pulmonary fibrosis, but little is known regarding the exact effect of $IFN-{\gamma}$ on the regulation of the MMPs. This study investigated the effects of $interferon-{\gamma}$ on the pulmonary fibrosis and the expression of the lung MMP-2,-9, TIMP-1,-2, and Th-2 cytokines in aa rat model of bleomycin induced pulmonary fibrosis. Materials and methods : Male, specific pathogen-free Sprague-Dawley rats were subjected to an intratracheal bleomycin instillation. The rats were randomized to a saline control, a bleomycin treated, and a bleomycin+$IFN-{\gamma}$ treated group. The bleomycin+$IFN-{\gamma}$ treated group was subjected to an intramuscular injection of $IFN-{\gamma}$ for 14 days. At 3, 7, 14, and 28 days after the bleomycin instillation, the rats were sacrificed and the lungs were harvested. In order to evaluate the effects of the $IFN-{\gamma}$ on lung fibrosis and inflammation, the lung hydroxyproline content, inflammation and fibrosis score were measured. Western blotting, zymography and reverse zymography were performed at 3, 7, 14, 28 days after bleomycin instillation in order to evaluate the MMP-2,-9, and TIMP-1,-2 expression level. ELISA was performed to determine the IL-4 and IL-13 level in a lung homogenate. Results : 1. 7 days after bleomycin instillation, inflammatory changes were more severe in the bleomycin+$IFN-{\gamma}$ group than the bleomycin group (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$2.08{\pm}0.15:2.74{\pm}0.29$, P<0.05), but 28 days after bleomycin instillation, lung fibrosis was significantly reduced as a result of the $IFN-{\gamma}$ treatment (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$3.94{\pm}0.43:2.64{\pm}0.13$, P<0.05). 2. 28 days after bleomycin instillation, the lung hydroxyproline content was significantly reduced as a result of $IFN-{\gamma}$ treatment (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$294.04{\pm}31.73{\mu}g/g:194.92{\pm}15.51{\mu}g/g$, P<0.05). 3. Western blotting showed that the MMP-2 level was increased as a result of the bleomycin instillation and highest in the 14 days after bleomycin instillation. 4. In zymography, the active forms of MMP-2 were significantly increased as a result of the $IFN-{\gamma}$ treatment 3 days after the bleomycin instillation, bleomycin+$IFN-{\gamma}$ group (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$209.63{\pm}7.60%:407.66{\pm}85.34%$, P<0.05), but 14 days after the bleomycin instillation, the active forms of MMP-2 were significantly reduced as a result of the $IFN-{\gamma}$ treatment (bleomycin group : bleomycin+$IFN-{\gamma}$ group=$159.36{\pm}20.93%:97.23{\pm}12.50%$, P<0.05). 5. The IL-4 levels were lower in the bleomycin and bleomycin+$IFN-{\gamma}$ groups but this was not significant, and the IL-13 levels showed no difference between the experiment groups. Conclusion : The author found that lung inflammation was increased in the early period but the pulmonary fibrosis was inhibited in the late stage as a result of $IFN-{\gamma}$. The inhibition of pulmonary fibrosis by $IFN-{\gamma}$ appeared to be associated with the inhibition of MMP-2 activation by $IFN-{\gamma}$. Further studies on the mechanism of the regulation of MMP-2 activation and the effects of MMP-2 activation on pulmonary fibrosis is warranted in the future.

A Study on the Influence of the Selective Attributes of Home Meal Replacement on Perceived Utilitarian Value and Repurchase Intention: Focus on Consumers of Large Discount and Department Stores (HMR(Home Meal Replacement) 선택속성이 지각된 효용적 가치, 재구매 의도에 미치는 영향에 관한 연구: 대형 할인마트와 백화점 구매고객을 대상으로)

  • Seo, Kyung-Hwa;Choi, Won-Sik;Lee, Soo-Bum
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.6
    • /
    • pp.934-947
    • /
    • 2011
  • The purpose of this study is to analyze products for good taste and convenience, which become an engine to constantly create customers. In addition, this study is aimed at investigating the relationship between the selective attributes of Home Meal Replacement, the perceived utilitarian value, and the repurchase intention, and drawing new suggestions on the Home Meal Replacement market from a new marketing perspective. Based on a total of 215 samples, this study reviewed the reliability and fitness of the research model and verified a total of 5 hypothesized using the Amos program. The result of study modeling was GFI=0.905, AGFI=0.849, NFI=0.889, CFI=0.945, and RMR=0.0.092 at the level of $x^2$=230.22 (df=126, p<0.001). First, the food quality (${\beta}$=0.221), convenience (${\beta}$=0.334), packing (${\beta}$=0.278), and employee service (${\beta}$=0.204) of home meal replacement consideration attributes had a positive (+) influence on perceived utilitarian value. Second, perceived utilitarian value (${\beta}$=0.584) had a positive (+) influence on repurchase intention. The factors to differentiate one company from other competitors in terms of the utilitarian value are the quality of food, convenience, wrapping, and services by employees. This study has illustrated the need to focus on the development of a premium menu to compete with other companies and to continue to research and develop nutritious foods that are easy to cook. Moreover, the key factors to have a distinct and constant competitive edge over other companies are the alleviation of consumer anxiety over wrapping container materials, the development of more designs, and the accumulation of service know-how. Therefore, it is necessary for a company to strongly develop the key factors based on its resources as a core capability.

Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients (토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가)

  • Woo, Joong-Yeol;Kim, Joo-Ho;Kim, Joon-Won;Baek, Jong-Geal;Park, Kwang-Soon;Lee, Jong-Min;Son, Dong-Min;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2012
  • Purpose: We evaluated usefulness of abdominal compressor for stereotactic body radiotherapy (SBRT) with unresectable hepatocellular carcinoma (HCC) patients and hepato-biliary cancer and metastatic liver cancer patients. Materials and Methods: From November 2011 to March 2012, we selected HCC patients who gained reduction of diaphragm movement >1 cm through abdominal compressor (diaphragm control, elekta, sweden) for HT (Hi-Art Tomotherapy, USA). We got planning computed tomography (CT) images and 4 dimensional (4D) images through 4D CT (somatom sensation, siemens, germany). The gross tumor volume (GTV) included a gross tumor and margins considering tumor movement. The planning target volume (PTV) included a 5 to 7 mm safety margin around GTV. We classified patients into two groups according to distance between tumor and organs at risk (OAR, stomach, duodenum, bowel). Patients with the distance more than 1 cm are classified as the 1st group and they received SBRT of 4 or 5 fractions. Patients with the distance less than 1 cm are classified as the 2nd group and they received tomotherapy of 20 fractions. Megavoltage computed tomography (MVCT) were performed 4 or 10 fractions. When we verify a MVCT fusion considering priority to liver than bone-technique. We sent MVCT images to Mim_vista (Mimsoftware, ver .5.4. USA) and we re-delineated stomach, duodenum and bowel to bowel_organ and delineated liver. First, we analyzed MVCT images to check the setup variation. Second we compared dose difference between tumor and OAR based on adaptive dose through adaptive planning station and Mim_vista. Results: Average setup variation from MVCT was $-0.66{\pm}1.53$ mm (left-right) $0.39{\pm}4.17$ mm (superior-inferior), $0.71{\pm}1.74$ mm (anterior-posterior), $-0.18{\pm}0.30$ degrees (roll). 1st group ($d{\geq}1$) and 2nd group (d<1) were similar to setup variation. 1st group ($d{\geq}1$) of $V_{diff3%}$ (volume of 3% difference of dose) of GTV through adaptive planing station was $0.78{\pm}0.05%$, PTV was $9.97{\pm}3.62%$, $V_{diff5%}$ was GTV 0.0%, PTV was $2.9{\pm}0.95%$, maximum dose difference rate of bowel_organ was $-6.85{\pm}1.11%$. 2nd Group (d<1) GTV of $V_{diff3%}$ was $1.62{\pm}0.55%$, PTV was $8.61{\pm}2.01%$, $V_{diff5%}$ of GTV was 0.0%, PTV was $5.33{\pm}2.32%$, maximum dose difference rate of bowel_organ was $28.33{\pm}24.41%$. Conclusion: Despite we saw diaphragm movement more than 5 mm with flouroscopy after use an abdominal compressor, average setup_variation from MVCT was less than 5 mm. Therefore, we could estimate the range of setup_error within a 5 mm. Target's dose difference rate of 1st group ($d{\geq}1$) and 2nd group (d<1) were similar, while 1st group ($d{\geq}1$) and 2nd group (d<1)'s bowel_organ's maximum dose difference rate's maximum difference was more than 35%, 1st group ($d{\geq}1$)'s bowel_organ's maximum dose difference rate was smaller than 2nd group (d<1). When applicating SBRT to HCC, abdominal compressor is useful to control diaphragm movement in selected patients with more than 1 cm bowel_organ distance.

  • PDF

The 1998, 1999 Patterns of Care Study for Breast Irradiation After Breast-Conserving Surgery in Korea (1998, 1999년도 우리나라에서 시행된 유방보존수술 후 방사선치료 현황 조사)

  • Suh Chang-Ok;Shin Hyun Soo;Cho Jae Ho;Park Won;Ahn Seung Do;Shin Kyung Hwan;Chung Eun Ji;Keum Ki Chang;Ha Sung Whan;Ahn Sung Ja;Kim Woo Cheol;Lee Myung Za;Ahn Ki Jung
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.192-199
    • /
    • 2004
  • Purpose: To determine the patterns on evaluation and treatment in the patient with early breast cancer treated with conservative surgery and radiotherapy and to improve the radiotherapy techiniques, nationwide survey was peformed. Materials and Methods: A web-based database system for korean Patterns of Care Study (PCS) for 6 common cancers was developed. Two hundreds sixty-one randomly selected records of eligible patients treated between 1998$\~$1999 from 15 hospitals were reviewed. Results: The patients ages ranged from 24 to 85 years(median 45 years). Infiltrating ductal carcinoma was most common histologic type (88.9$\%$) followed by medullary carcinoma (4.2$\%$) and infiltrating lobular carcinoma (1.5$\%$). Pathologic T stage by AJCC was T1 in 59.7$\%$ of the casses, T2 in 29.5$\%$ of the cases, Tis in 8.8$\%$ of the cases. Axillary lymph node dissection was peformed I\in 91.2$\%$ of the cases and 69.7$\%$ were node negative. AJCC stage was 0 in 8.8$\%$ of the cases, stage I in 44.9$\%$ of the cases, stage IIa in 33.3$\%$ of the cases, and stage IIb in 8.4$\%$ of the cases. Estrogen and progesteron receptors were evaluated in 71.6$\%$, and 70.9$\%$ of the patients, respectively. Surgical methods of breast-conserving surgery was excision/lumpectomy in 37.2$\%$, wide excision in 11.5$\%$, quadrantectomy in 23$\%$ and partial mastectomy in 27.5$\%$ of the cases. A pathologically confirmed negative margin was obtained in 90.8$\%$ of the cases. Pathological margin was involved with tumor in 10 patients and margin was close (less than 2 mm) in 10 patients. All the patients except one recieved more than 90$\%$ of the planned radiotherapy dose. Radiotherapy volume was breast only In 88$\%$ of the cases, breast+supraclavicular fossa (SCL) in 5$\%$ of the cases, and breast+ SCL+ posterior axillary boost in 4.2%$\%$of the cases. Only one patient received isolated internal mammary lymph node irradiation. Used radiation beam was Co-60 in 8 cases, 4 MV X-ray in 115 cases, 6 MV X-ray in 125 cases, and 10 MV X-ray in 11 cases. The radiation dose to the whole breast was 45$\~$59.4 Gy (median 50.4) and boost dose was 8$\~$20 Gy (median 10 Gy). The total radiation dose delivered was 50.4$\~$70.4 Gy (median 60.4 Gy). Conclusion: There was no major deviation from current standard in the patterns of evaluation and treatment for the patients with early breast cancer treated with breast conservation method. Some varieties were identified in boost irradiation dose. Separate analysis for the datails of radiotherapy planning will be followed and the outcome of treatment is needed to evaluate the process.

The Comparative Analysis of the Titer of Seroconversion Rate Through the Natural Antibody and Antibody after Vaccination of Hepatitis A (A형 간염의 자연항체와 예방접종을 통한 항체 생성률의 역가 비교분석)

  • Kwon, Won Hyun;Kim, Kyung Hwa;Cho, Kyung A;Moon, Ki Choon;Kim, Jung In;Lee, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.95-100
    • /
    • 2013
  • Purpose: Since 2008, hepatitis A patients was rapidly increasing. So, Most of the health checkup examinees were interested in whether hepatitis A antibody was a lot. thereby The number of tests was increasing. In recent years, Antibody test results in the range of cut-off values were increased. According to the cause analysis, most examinees had a hepatitis A vaccine. This study was conducted to classify hepatitis A antibody as natural antibody and antibody after vaccination and compared the titer for seroconversion rate based on cut-off values. Materials and Methods: For a month in August 2012, First, We surveyed 185 health examinees and classified 119 health examinees who had acquired natural antibody. Second, for employees who were inoculated against hepatitis at our hospital, We classified into 53 primary inoculators and 59 secondary inculators. when the standard of cut-off value was 1, The seroconversion rate was compared the titer divided by 0.90-1.10 (${\pm}$), 0.60-0,89 (1+), 0.30-0.59 (2+), 0.01-0.29 (3+) and we compared the titer for seroconversion rate by each manufacturer after vaccination. Results: When the standard of cut-off value was 1, the titer of 119 health examinees who had acquired natural antibody was 0.90-1.10 (${\pm}$): 0%, 0.60-0.89 (1+): 0%, 0.30-0.59 (2+): 4.2%, 0.01-0.29 (3+): 96% and the titer of <0.60 ($${\geq_-}2+$$) was 100%. The titer of 53 primary inoculators was 0.90-1.10 (${\pm}:59.1%$), 0.60-0.89 (1+): 18.1%, 0.30-0.59 (2+): 18.1%, 0.01-0.29 (3+): 4.6% and the seroconversion rate was 45.3%. The titer of $${\geq_-}0.60$$ ($${\leq_-}1+$$) was 77.3%. The titer of 59 secondary inoculators was 0.90-1.10 (${\pm}:1.9%$), 0.60-0.89 (1+): 15.4%, 0.30-0.59 (2+): 36.54%, 0.01-0.29 (3+): 46.2% and the seroconversion rate was 88.1%. The titer of <0.60 ($${\geq_-}2+$$) was 82.7%. When we compared the titer for seroconversion rate by each manufacturer after vaccination, the seroconversion rate of 53 primary inoculators was BNIBT: 20.8% (${\pm}:24.5%$), GB: 15.7% (${\pm}:7.8%$), RIAKEY: 94.3% (${\pm}:3.8%$), ROCHE: 83% (${\pm}:0%$), ABBOTT: 73.1% (${\pm}:5.8%$) and the seroconversion rate of 59 secondary inoculators was BNIBT : 86.4% (${\pm}:1.7%$), GB: 88.5% (${\pm}:1.9%$), RIAKEY: 100% (${\pm}:0%$), ROCHE: 98.3% (${\pm}:0%$), ABBOTT: 98.2% (${\pm}:0%$). Conclusion: The study show that the titer of natural immune antibodies is higher than the titer of vaccination and the titer of secondary inoculation is mainly higher than the titer of primary inoculation. Consequently, if we know the titer of hepatitis A antibodies, it will help to give resullt reports. And then, when we compared the titer and the seroconversion rate by each manufacturer, There was a very distinct difference. As the test subjects inoculate against hepatitis A (HAV), it is considered BNIBT, GB will occur false negative rate and RIAKEY, ROCHE, ABOTT will occur false positive rate.

  • PDF

Preliminary Report of the $1998{\sim}1999$ Patterns of Care Study of Radiation Therapy for Esophageal Cancer in Korea (식도암 방사선 치료에 대한 Patterns of Care Study ($1998{\sim}1999$)의 예비적 결과 분석)

  • Hur, Won-Joo;Choi, Young-Min;Lee, Hyung-Sik;Kim, Jeung-Kee;Kim, Il-Han;Lee, Ho-Jun;Lee, Kyu-Chan;Kim, Jung-Soo;Chun, Mi-Son;Kim, Jin-Hee;Ahn, Yong-Chan;Kim, Sang-Gi;Kim, Bo-Kyung
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.79-92
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: For the first time, a nationwide survey in the Republic of Korea was conducted to determine the basic parameters for the treatment of esophageal cancer and to offer a solid cooperative system for the Korean Pattern of Care Study database. $\underline{Materials\;and\;Methods}$: During $1998{\sim}1999$, biopsy-confirmed 246 esophageal cancer patients that received radiotherapy were enrolled from 23 different institutions in South Korea. Random sampling was based on power allocation method. Patient parameters and specific information regarding tumor characteristics and treatment methods were collected and registered through the web based PCS system. The data was analyzed by the use of the Chi-squared test. $\underline{Results}$: The median age of the collected patients was 62 years. The male to female ratio was about 91 to 9 with an absolute male predominance. The performance status ranged from ECOG 0 to 1 in 82.5% of the patients. Diagnostic procedures included an esophagogram (228 patients, 92.7%), endoscopy (226 patients, 91.9%), and a chest CT scan (238 patients, 96.7%). Squamous cell carcinoma was diagnosed in 96.3% of the patients; mid-thoracic esophageal cancer was most prevalent (110 patients, 44.7%) and 135 patients presented with clinical stage III disease. Fifty seven patients received radiotherapy alone and 37 patients received surgery with adjuvant postoperative radiotherapy. Half of the patients (123 patients) received chemotherapy together with RT and 70 patients (56.9%) received it as concurrent chemoradiotherapy. The most frequently used chemotherapeutic agent was a combination of cisplatin and 5-FU. Most patients received radiotherapy either with 6 MV (116 patients, 47.2%) or with 10 MV photons (87 patients, 35.4%). Radiotherapy was delivered through a conventional AP-PA field for 206 patients (83.7%) without using a CT plan and the median delivered dose was 3,600 cGy. The median total dose of postoperative radiotherapy was 5,040 cGy while for the non-operative patients the median total dose was 5,970 cGy. Thirty-four patients received intraluminal brachytherapy with high dose rate Iridium-192. Brachytherapy was delivered with a median dose of 300 cGy in each fraction and was typically delivered $3{\sim}4\;times$. The most frequently encountered complication during the radiotherapy treatment was esophagitis in 155 patients (63.0%). $\underline{Conclusion}$: For the evaluation and treatment of esophageal cancer patients at radiation facilities in Korea, this study will provide guidelines and benchmark data for the solid cooperative systems of the Korean PCS. Although some differences were noted between institutions, there was no major difference in the treatment modalities and RT techniques.

Usefulness of Stomach Extension after Drinking Orange Juice in PET/CT Whole Body Scan (PET/CT 전신 영상에서 오렌지 주스(Orange Juice)를 이용한 위장 확장 영상의 유용성)

  • Cho, Seok-Won;Chung, Seok;Oh, Shin-Hyun;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.86-92
    • /
    • 2009
  • Purpose: The PET/CT has a clear distinction on the lesion of the functional image by adding anatomical information. It also could reduce the examination time using CT data as the attenuation-correction. When the stomach was contracted from a fast, it could bring a misinterpretation of the cancer of the lesion with a presence of physiological $^{18}F$-FDG uptake in stomach and it occasionally would bring an additional scan to confirm. To complement this shortcoming, the method that the patients had water before the examination to extend the stomach had been attempted. However, a short excretion time of the stomach did not give sufficiently extended image of the stomach. Then the patients had additional water and had the examination again. Therefore, the noticed fact is that the stomach excretion time depends on calories, protein content, and the level of carbohydrate. In this study, we use an orange juice to evaluate the extension of the stomach and usefulness of it. Materials and Methods: PET/CT scan were obtained on total 150 of patient from February 2008 to October2008, There were 3 groups in this study and each group had 50 patients. First group drank nothing, Second group drank water and third group drank orange juice. The patients (man 25, female 25) not drinking are the age of 30~71 years old (average: 54), the patients (man: 25, female: 25) drinking water (400 cc) are the age of 28~71 years old (average: 54) and the patients (man: 25, female: 25) drinking orange juice (400 cc) are the age of 32~74 years old (average: 56). The patients were fasted in 6-8 hours before the test, the patients were not diabetic. $^{18}F$-FDG 370~555 MBq were injected intravenously. The patients were in stable position for 1 hour, than the image was obtained. The patients drank water and other patients drank orange juice before Whole body scan. The image scan started from mid-femur to skull base. The emission scan acquired for three minutes per bed and the images were reconstructed. Stomach extension analysis is measured from vertical and horizontal length. Results: Stomach Extension was described as the vertical length of the Non Drink Group was $1.20{\pm}0.50\;cm$, horizontal length was $1.4{\pm}0.53\;cm$, the vertical length of the Water Drink Group was $1.67{\pm}0.63\;cm$, horizontal length was $1.65{\pm}0.77\;cm$, the vertical length of Orange juice Drink Group was $3.48{\pm}0.77\;cm$, horizontal length was $3.66{\pm}0.77\;cm$ in coronal image. Stomach Extension was described the vertical length of the Non Drink Group was $2.03{\pm}0.62\;cm$, horizontal length was $1.69{\pm}0.68\;cm$, the vertical length of Water Drink Group was $5.34{\pm}1.62\;cm$, horizontal length was $2.45{\pm}0.72\;cm$, the vertical length of Orange juice Drink Group was $7.74{\pm}1.62\;cm$, horizontal length was $3.57{\pm}0.77\;cm$ in transverse image. The Stomach Extension has specific differences (p<0.001). The SUVs shows the Non Drink Group were measured as Liver $2.52{\pm}0.42$, Lung $0.51{\pm}0.14$, the Water Drink Group were measured as Liver $2.47{\pm}0.38$, Lung $0.50{\pm}0.14$, Orange juice Drink Group were measured as Liver $2.47{\pm}0.38$, Lung $0.50{\pm}0.14$. The SUVs did not have specific differences (p>0.759). Conclusions: There was not a large difference of SUV in three groups. When the patients drank Orange juice and water, the range extension of stomach was higher than without drinking nothing and it was possible to acquire fully extended images. Therefore, it will be possible that unnecessary additional stomach scans will be reduced by drinking orange juice before the examination so that the patients' claim from uncomfortable and long period of fast will be minimized.

  • PDF