• Title/Summary/Keyword: and CCC

Search Result 196, Processing Time 0.032 seconds

A Study on Various Soil Stiffness Evaluation Methods with Field Test (현장시험을 통한 다양한 지반강성 평가방법에 대한 연구)

  • Yoo, Wan-Kyu;Kim, Byoung-Il;Kim, Ju-Hyong;Park, Keun-Bo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1373-1380
    • /
    • 2010
  • The plate loading test(PLT) and the field density test are mainly used on the construction of embankments to control the compaction of a limited layer thickness. These two test methods are very time consuming and inefficient, but they are still commonly used as the methods of quality control for soil compaction. In the last 3 decades, many devices such as geogauge, light falling weight deflectometer(LFWD) and dynamic cone penetrometer(DCP) etc., have been introduced into the engineering market with the objective of acquiring in situ stiffness properties of the compacted soil layers. Recently, a new type of sensor, called compactometer, which in mounted on the drum of a roller and measures impact forces continuously with GPS, called as Continuous Compaction Control(CCC), has come into use in many countries such as America, Germany, Japan and so on. The main objective of this paper is to assess the potential use of these new devices as quality control and assurance devices for compacted soil layers. Based on this study, compactometer and the LFWD results werestrongly correlated with the result obtained from the PLT and the field density test.

An Empirical Analysis about the usefulness of Internal Control Information on Corporate Soundness Assessment (기업건전성평가에 미치는 내부통제정보의 유용성에 관한 실증분석 연구)

  • Yoo, Kil-Hyun;Kim, Dae-Lyong
    • Journal of Digital Convergence
    • /
    • v.14 no.8
    • /
    • pp.163-175
    • /
    • 2016
  • The purpose of this study is to provide an efficient internal control system formation incentives for company and to confirm empirically usefulness of the internal accounting control system for financial institutions by analyzing whether the internal control vulnerabilities of companies related significantly to the classification and assessment of soundness of financial institutions. Empirical analysis covered KOSPI, KOSDAQ listed companies and unlisted companies with more than 100 billion won of assets which have trading performance with "K" financial institution from 2008 until 2013. Whereas non-internal control vulnerability reporting companies by the internal control of financial reporting received average credit rating of BBB on average, reporting companies received CCC rating. And statistically significantly, non-reporting companies are classified as "normal" and reporting companies are classified as "precautionary loan" when it comes to asset quality classification rating. Therefore, reported information of internal control vulnerability reduced the credibility of the financial data, which causes low credit ratings for companies and suggests financial institutions save additional allowance for asset insolvency prevention and require high interest rates. It is a major contribution of this study that vulnerability reporting of internal control in accordance with the internal control of financial reporting can be used as information significant for the evaluation of financial institutions on corporate soundness.

Assessment of the Angstrom-Prescott Coefficients for Estimation of Solar Radiation in Korea (국내 일사량 추정을 위한 Angstrom-Prescott계수의 평가)

  • Hyun, Shinwoo;Kim, Kwang Soo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.221-232
    • /
    • 2016
  • Models to estimate solar radiation have been used because solar radiation is measured at a smaller number of weather stations than other variables including temperature and rainfall. For example, solar radiation has been estimated using the Angstrom-Prescott (AP) model that depends on two coefficients obtained empirically at a specific site ($AP_{Choi}$) or for a climate zone ($AP_{Frere}$). The objective of this study was to identify the coefficients of the AP model for reliable estimation of solar radiation under a wide range of spatial and temporal conditions. A global optimization was performed for a range of AP coefficients to identify the values of $AP_{max}$ that resulted in the greatest degree of agreement at each of 20 sites for a given month during 30 years. The degree of agreement was assessed using the value of Concordance Correlation Coefficient (CCC). When $AP_{Frere}$ was used to estimate solar radiation, the values of CCC were relatively high for conditions under which crop growth simulation would be performed, e.g., at rural sites during summer. The statistics for $AP_{Frere}$ were greater than those for $AP_{Choi}$ although $AP_{Frere}$ had the smaller statistics than $AP_{max}$ did. The variation of CCC values was small over a wide range of AP coefficients when those statistics were summarized by site. $AP_{Frere}$ was included in each range of AP coefficients that resulted in reasonable accuracy of solar radiation estimates by site, year, and month. These results suggested that $AP_{Frere}$ would be useful to provide estimates of solar radiation as an input to crop models in Korea. Further studies would be merited to examine feasibility of using $AP_{Frere}$ to obtain gridded estimates of solar radiation at a high spatial resolution under a complex terrain in Korea.

The Assessment of Wastewater Treatment and Management Using Performance Indicators and Cluster Analysis (수행능 지표(Performance Indicator)와 군집분석을 이용한 하수도시설 및 운영 평가)

  • Kim, Shin-Geol;Choi, Tae-Yong;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.165-175
    • /
    • 2007
  • Performance indicators haven't been used for the assessment of the wastewater treatment facility or management in Korea yet, therefore they are going to be important parts in wastewater utilities because they are used to understand present situation and to compare one with other wastewater utilities. In this study, we used performance indicators to assess the condition of wastewater utilities and they were divided into four categories (A, B, C, and D). A category represented the condition of the planning & construction and composed of wastewater supply, disaster defence and employees. B category represented maintenance of wastewater utilities and were composed of manhole, sewer, and technical employees. C category showed the operation efficiency of wastewater utilities and D category represented the environmental load. To analyze the situation of wastewater utilities overall, cluster analysis was performed using four categori' es indicators. And CCC (Cubic Clustering Criterion) and R-square were used to decide the proper number of clusters, and wastewater utilities of 48 cities were divided into 5 groups(I, II, III, IV, and V groups). Each cluster was analyzed by average and standard deviation to understand the situation of wastewater utilities. A group analysis showed that IV and V clusters were insufficient, B group showed that I and IV groups were insufficient, C group showed all clusters are above average, and D group was also like C group.

Modeling and simulation of foxboro control system for YGN#3,4 power plant (영광 3,4호기 Foxboro 제어시스템 모델링 및 시뮬레이션)

  • 김동욱;이용관;유한성
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.179-182
    • /
    • 1997
  • In a training simulator for power plant, operator's action in the MCR(Main Control Room) are given to plant process and computer system model as an inputs, and the same response as in real power plant is provided in real time. Inter-process communication and synchronization are especially important among various inputs. In the plant simulator, to simulate the digital control system such as FOXBORO SPEC-200 Micro control system, modification and adaptation of control card(CCC) and its continuous display station(CDS) is necessary. This paper describes the modeling and simulation of FOXBORO SPEC-200 Micro control system applied to Younggwang nuclear power plant unit #3 & 4, and its integration process to the full-scope replica type training simulator. In a simulator, display station like CDS of FOXBORO SPEC-200 Micro control system is classified as ITI(Intelligent Type Instrument), which has a micro processor inside to process information and the corresponding alphanumeric display, and the stimulation of ITI limits the important functions in a training simulator such as backtrack, replay, freeze and IC reset. Therefore, to achieve the better performance of the simulator, modification of CDS and special firmware is developed to simulate the FOXBORO SPEC-200 Micro control system. Each control function inside control card is modeled and simulated in generic approach to accept the plant data and control parameter conveniently, and debugging algorithms are applied for massive coding developed in short period.

  • PDF

대구대학교 도서관 발전계획에 관한 연구

  • 윤희윤
    • Journal of Korean Library and Information Science Society
    • /
    • v.24
    • /
    • pp.519-557
    • /
    • 1996
  • The purpose of this study is to suggest the strategic development model for the Taegu University Library preparing the 21st century. The results of the study are summarized as follows. 1. Size of collection aim to 697,000 volumes and 1,605 titles until 2000, 975,000 volumes and 3,224 titles until 2005, and 1,185,000 volumes and journals of 6,482 titles until 2010. 2. The library should have 36 professionals until 2000, 53 professionals until 2005, and 69 professionals until 2,010. And library should reorganize 3 departments and 14 sections up to 2,000, 6 departments and 22 sections up to 2,010. After that, the university should grope for a best way to combine the library and the CCC (Computing and Communication Center) into a single unit. 3. In case of space plan, it is necessary that library have to the total area of 31,478m$^{2}$. To find the recommended area, the library must improve the ratio of the net space 50 percent to 75 percent. 4. The model of scholarly information system should be designed to provide a total array of information services to the students and professors, envisioned as typically a user seeking information at a desk and workstation, regardless of format or computing capacity.

  • PDF

Restriction endonuclease maps of three plasmids from bacillus thuringiensis serovar israelensis 4Q1 (Bacillus thuringiensis serovar israelensis 4Q1로부터 분리된 plasmid 제한효소지도 작성)

  • Faust, R.M.;;;C.L.Meyers-Dowling;P.E.McCawley
    • Korean Journal of Microbiology
    • /
    • v.23 no.2
    • /
    • pp.122-128
    • /
    • 1985
  • Bacillus thuringiensis serovar israelensis 4Q1 contains 8 different covalently closed-circular (CCC) plasmids of molecular weight 204, 267, 109, 103, 16, 7.6, 6.4, and 5.0kb. The three smallest plasmids, designated pBti6, and pBti8 may prove to be useful as cloning vectors because of thier size and ease of isolation. The three plasmids were incubated separately with 9 different restriction enzymes and 7 of the enzymes tested cleaved one or more of the plasmids. Plasmid pBti6 has a single site for Bg1 II, Pst I and Pvu II, two sites for Bc1 I and Eco RI, and five sites for Hind III. Plasmid pBti7 has a single site for Bam HI and Pst I, two sites for Hind III, and three sites for PvuII. Plasmic pBti8 has a single site for Bam HI, BelI and Hind III, two sites for Eco RI, and three sites for Bgl II and Pvu II. Composite restriction enzyme maps for pBti6, pBti7 and pBti8 were constructed. The sites of restriction enzyme cleavage were determined by single, double and partial digests of the plasmid DNA. All the restriction sites were aligned relative to the single Bgl II(pBti6), Pst I(pBti7) or Hind III(pBti8) site, respectively.

  • PDF

IDLE PERFORMANCE OF AN SI ENGINE WITH VARIATIONS IN ENGINE CONTROL PARAMETERS

  • Kim, D.S.;Cho, Y.S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.7
    • /
    • pp.763-768
    • /
    • 2006
  • Emission reduction in the cold start period of SI engines is crucial to meet stringent emission regulations such as SULEV Emissoin reduction is the starting point of the study in the which the variable valve timing (VVT) technology may be one promising method to minimize cold start emissions while maintaining engine performance. This is because it is possible to change valve overlap and residual gas fraction during cold start and idle operations. Our previous study showed that spark timing is another important factor for reducing cold-start emissions since it affects warm-up time of close-coupled catalysts (CCC) by changing exhaust gas temperature. However, even though these factors may be favorable for reduction of emissions, they may deteriorate combustion stability in these operating conditions. This means that the two variables should be optimized for best exhaust emissions and engine stability. This study investigated the effects of valve and spark timings in idle performance such as combustion stability and exhaust emissions. Experiments showed that valve timings significantly affected engine stability and exhaust emissions, especially CO and $NO_x$, due to change in residual gas fraction within the combustion chamber. Spark timing also affects HC emissions and exhaust gas temperature. Yet it has no significant effects on combustion stability. A control strategy of proper valve timing and spark timing is suggested in order to achieve a reduction in exhaust emissions and a stable operation of the engine in a cold start and idle operation.

Structural and Functional Stability of the Genetic Recombinant Plasmid pCU103 in Different Water Environments

  • Kim, Chi-Kyung;Kwak, Myoung-Ja;Lee, Sung-Gie
    • Journal of Microbiology
    • /
    • v.34 no.3
    • /
    • pp.241-247
    • /
    • 1996
  • The stability of the genetically engineered microorganisms and their recombinant plasmids released in natural environments has been regarded as one of the molecular ecological topics. In this study, the recombinant plasmids pCU103 in which the pcbCD genes involved in biodegradation of biphenyl and 4-chlorobiphenyl were cloned in pBluescript SK(+) vector, were examined for their structural and functional stability in different waters at 15 $^{\circ}C$ by the methods of electrophoresis, Southern hybridization, quantification with fluorescent dye, and transformation. The recombinant plamids maintained their stabilities for about 30 days in sterilized distilled water (SDW), 15 days in autoclaved creek water (AW), 25 days in filtered and autoclaved non-sterile creek water (FAW), 4 days in Luria-Bertani (LB) broth, and less than one day in filtered non-sterile creek water (FW). The covalently closed circular (CCC) form of the plasmid was decreased and open circular (OC) form was increased as a function of incubation time, and then linear (L) form was produced to be ultimately degraded out. The degradation rates of the plasmid were proportionally correlated to trophic level of the water, and the biological factor such as DNases was found to be one of the most critical factors affecting structural and functional stability of the plasmid in non-sterile natural water.

  • PDF

Development of Education Courseware for Clinical Care Classification System based PC and Smartphone (PC와 스마트 폰 기반 임상간호분류체계 교육 코스웨어 개발)

  • Hong, Hae-Sook;Lee, In-Keun;Cho, Hune;Kim, Hwa-Sun
    • Journal of Internet Computing and Services
    • /
    • v.12 no.3
    • /
    • pp.49-56
    • /
    • 2011
  • It is urgently needed to develop programs supporting lifelong education for nurses and students of nursing, which are not restricted by time or space and use personal computers or smartphone. The purpose of this study is to develop CCC(Clinical Care Classification) System into a education program and provides guideline to support clinical tasks for students of nursing. Comparing the search times of the book guideline and the web guideline developed, this study found that it was over 3.5 times faster. And its error rate was over four times lower. This result shows that it can provide accurate intervention for patients since it approaches to intervention and evaluation guideline fast and precisely in the actual tasks of nursing.