• 제목/요약/키워드: anchor bolt

검색결과 98건 처리시간 0.028초

터널의 굴착을 위한 수직사면의 안정대책 방안 수립 및 시행 (Slope stability method establish and carry out in vertical slope for tunnel excavation)

  • 박철숙;김준용;곽한;김민조;최우경
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.992-1006
    • /
    • 2008
  • The tunnel type spillways is under construction to increasing water reservoir capacity in Dae-am dam. Cutting-slope adjacent to outlet of spillways had been originally designed to be 63 degrees and about 65m in height. Examination is carried out in preceding construction that it is caused to some problems possibility which of machine for slope cutting couldn't approach to the site, blasting for cutting slope might have negative influence on highway and roads nearby, and fine view along the Tae-hwa river would be eliminated. In order to establish stability of tunnel and more friendly natural environment that we are carry out detailed geological surface survey and analysis of slope stability. So, we are design and construct for tunnel excavation with possible method that it is keep up natural slope. The result of survey and analysis that natural slope was divided 3 zone(A, B, C zone). In A and B zone, in first removed floating rock, high tensile tension net is install that it prevent of release and falling of rock, in order to security during under working. In addition to, pre-stressed rock anchor is install purpose of security during tunnel excavation because of fault zone near vertical developed above excavation level. Zone C is relatively good condition of ground, design is only carry out random rock bolt. All zone are designed and constructed drainage hole for groundwater and surface water is easily drain. Desinged slpoe is harmony with near natural environment. Successfully, construction is completed.

  • PDF

탈·부착식 교량 방호울타리의 3차원 유한요소 정적해석 및 안전성 평가 (Three-dimensional finite element static analysis and safety evaluation of attachable roadside barriers on bridges)

  • 이상열
    • 한국산학기술학회논문지
    • /
    • 제15권4호
    • /
    • pp.2414-2418
    • /
    • 2014
  • 본 연구에서는 교량 통합 부대시설 모듈 구조 개발을 위하여 측면 탈 부착식 교량 방호울타리의 3차원 유한요소해석 및 구조 안정성 평가를 수행하였다. LS-DYNA 프로그램을 사용하여 연결 모듈의 격벽 간격 및 볼트 갯수 변화가 방호울타리 구조의 변위 및 응력에 미치는 영향을 상세 분석하였다. 본 연구에서는 LS-DYNA 프로그램을 사용한 유한요소해석은 콘크리트 바닥판에 삽입된 앵커볼트로 연결된 모듈 위에 설치된 방호울타리의 정적 거동과 구조 안전성을 분석하기 위하여 확장되었다. 수치해석은 6개의 매개변수에 대하여 방호울타리에 발생된 처짐 및 응력분포를 비교 분석하였으며 모두 구조적으로 안전성을 확보하는 것으로 나타났다.

단관비계의 구조규격에 관한 연구 (A Study on the Structural Standard of the Tube and Coupler Scaffold)

  • 이영섭
    • 한국안전학회지
    • /
    • 제5권2호
    • /
    • pp.66-75
    • /
    • 1990
  • This study is conducted to establish the structural standard of tube and coupler scaffold which is suitable for our present stuation through the comparison analysis for domestic and foreign standards as well as measurement of field survey. The results of this study are as follows : 1) The load is classified by three categories, light-duty(equal and lower than 150kg/m$^2$), medium-duty(150-250 kg/m$^2$), heavy-duty(250-350kg/m$^2$), and the equivalent horizontal length of side posts is each, 1.5-1.8m, 1.2-1.5m, equal and lower than 1.2m, and the equivalent horizontal length between front and rear posts is each 1.2-1.5m, 0.9-1.2m, equal and lower thatn 0.9m, in accordance with the load classification. 2) The height between upper and lower runner is equal and lower than 1.5m, and the brace across the width of scaffold should be installed within 15m in horizontal direction at 45 degree angle. 3) The entire scaffold should be securely tied to the wall of permanent structure with uslng anchor and bolt at intervals not to exceed 6m in case of non-connection and 4.5m in case of connection in both horizontal and vertical direction. 4) The post should be installed on the sound foundation tied to lumber footing with using base plate, and standard platform plank should be produced in the factory and widely used in the construction field.

  • PDF

Effect of Anchorage Number on Behavior of Reinforced Concrete Beams Strengthened with Glass Fiber Plates

  • Kaya, Mustafa;Kankal, Zeynel Cagdas
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권4호
    • /
    • pp.415-425
    • /
    • 2015
  • Reinforced concrete beams with insufficient shear reinforcement were strengthened using glass fiber reinforced polymer (GFRP) plates. In the study, the effect of the number of bolts on the load capacity, energy dissipation, and stiffness of reinforced concrete beams were investigated by using anchor bolt of different numbers. Three strengthened with GFRP specimens, one flexural reference specimen designed in accordance to Regulation on Buildings Constructed in Disaster Areas rules, and one shear reinforcement insufficient reference specimen was tested. Anchorage was made on the surfaces of the beams in strengthened specimens using 2, 3 and 4 bolts respectively. All beams were tested under monotonic loads. Results obtained from the tests of strengthened concrete beams were compared with the result of good flexural reference specimen. The beam in which 4 bolts were used in adhering GFRP plates on beam surfaces carried approximately equal loads with the beam named as a flexural reference. The amount of energy dissipated by strengthened DE5 specimen was 96 % of the amount of energy dissipated by DE1 reference specimen. Strengthened DE5 specimen initial stiffness equal to DE1 reference specimen initial stiffness, but strengthened DE5 specimen yield stiffness about 4 % lower than DE1 reference specimen yield stiffness. Also, DE5 specimen exhibited ductile behavior and was fractured due to bending fracture. Upon the increase of the number of anchorages used in a strengthening collapsing manner of test specimens changed and load capacity and ductility thereof increased.

Comparison of structural foam sheathing and oriented strand board panels of shear walls under lateral load

  • Shadravan, Shideh;Ramseyer, Chris C.;Floyd, Royce W.
    • Advances in Computational Design
    • /
    • 제4권3호
    • /
    • pp.251-272
    • /
    • 2019
  • This study performed lateral load testing on seventeen wood wall frames in two sections. Section one included eight tests studying structural foam sheathing of shear walls subjected to monotonic loads following the ASTM E564 test method. In this section, the wood frame was sheathed with four different types of structural foam sheathing on one side and gypsum wallboard (GWB) on the opposite side of the wall frame, with Simpson HDQ8 hold down anchors at the terminal studs. Section two included nine tests studying wall constructed with oriented strand board (OSB) only on one side of the wall frame subjected to gradually applied monotonic loads. Three of the OSB walls were tied to the baseplate with Simpson LSTA 9 tie on each stud. From the test results for Section one; the monotonic tests showed an 11 to 27 percent reduction in capacity from the published design values and for Section two; doubling baseplates, reducing anchor bolt spacing, using bearing plate washers and LSTA 9 ties effectively improved the OSB wall capacity. In comparison of sections one and two, it is expected the walls with structural foam sheathing without hold downs and GWB have a lower wall capacity as hold down and GWB improved the capacity.

Strength of connection fixed by TOBs considering out-of-plane tube wall deformation-Part 1: Tests and numerical studies

  • Wulan, Tuoya;Wang, Peijun;Xia, Chengxin;Liu, Xinyu;Liu, Mei;Liu, Fangzhou;Zhao, Ou;Zhang, Lulu
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.49-57
    • /
    • 2022
  • This paper presents a study on the behavior of a bolted T-stub to square tube connection using Thread-fixed One-side Bolts (TOBs) through tests and numerical simulations. It outlines a research work of four connections with focus on the failure modes and strengths of the connection under tensile load. It was observed that the thread anchor failure caused by shear failure of hole threads controlled the final failure of the connection in the tests. Meanwhile, the out-of-plane deformation of tube wall resulted in the contact separation between hole threads and bolt threads, which in turn reduced the shear strength of hole threads. Finite element models (FEMs) allowing for the configuration details of the TOBs fixed connection are then developed and compared with the test results. Subsequently, the failure mechanism of hole threads and stress distribution of each component are analyzed based on FEM results. It was concluded that the ultimate strength of connection was not only concerned with the shear strength of hole threads, but also was influenced by the plastic out-of-plane deformation of tube wall. These studies lay a foundation for the establishment of suitable design methods of this type of connection.

소규모 철골조 노출형 주각부의 반복가력 실험 (Cyclic Loading Test for Exposed Column-base Plate Connections of Small-size Steel Structures)

  • 임우영;유영찬;유미나
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권2호
    • /
    • pp.34-45
    • /
    • 2017
  • 본 연구에서는 소규모 철골조에 대한 기존 건축물의 접합부 현황조사와 분석을 통해 노출형 주각부에 대한 내진성능을 평가하였다. 총 9개의 주각부에 대한 반복가력 실험을 통해 휨강도, 변형능력, 그리고 초기강성 등이 조사되었다. 실험의 주요 변수는 베이스 플레이트의 두께, 앵커볼트의 개수와 매립깊이, 앵커볼트 후크의 유무, 그리고 리브 플레이트의 유무이다. 본 실험결과에 의하면, 주각부의 휨거동은 앵커볼트의 개수와 매립깊이, 그리고 베이스 플레이트의 두께에 영향을 받는 것으로 나타났다. 반면에, 주각부에 설치된 리브플레이트는 휨강도에 큰 영향을 주지 않는 것으로 나타났다. 종합적으로 노출형 철골 주각부와 기초부 그리고 앵커볼트 등이 모두 현행 구조기준을 만족한다고 할지라도, 앵커볼트와 기초부 콘크리트 사이의 부착력이 충분하지 않을 경우, 슬립형 거동이 관측되어 개선이 필요한 것으로 파악되었다. 앵커볼트의 매립깊이가 현행 구조기준을 만족하고, 앵커볼트에 후크가 설치된 경우, 노출형 주각부의 초기강성은 주각부가 구속되었을 때의 휨강성 하한값의 약 15% 수준인 것으로 나타났다.

해수 염기 침투방지를 위한 성능개선 형 물배출 앵커 및 트랩볼트 개발에 관한 연구 (Developing an improved water discharge anchor & trap bolt to prevent basic salt penetration to harbor structures)

  • 옥종호;문상덕;이화선;신경수
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.674-682
    • /
    • 2018
  • 노후된 철근콘크리트 항만 구조물을 보수보강하기 위한 기존의 공법 대부분은 염기침투와 균열발생을 막기 위한 목적으로 개발되었으며 슬래브나 보 하부를 섬유복합체나 섬유복합체 패널로 벽지 바르듯 빈틈없이 접착시키는 공정으로 이루어져 있다. 하지만 이런 공법들은 섬유제품의 밀폐성 때문에 항만구조물 상부에서 유입되는 빗물 등의 수분을 외부로 배출시키지 못한다. 배출되지 않은 물은 보수보강 부위를 물통역할을 하게 되어 슬래브나 보의 피복콘크리트 전체를 탈락시키는 문제를 발생케 한다. 이에 본 연구진은 선행연구에서 콘크리트 구조물 내부로 유입된 수분을 배출하는 물배출 앵커 및 트랩볼트를 개발하였다. 하지만 앵커볼트의 매입부분의 수분은 배출되지 않아 잔류수분 문제가 발생하였다. 본 연구에서는 이런 잔류수분 문제를 해결하기 위해 기 개발된 물배출 앵커 및 트랩볼트 측면에 홀을 추가로 천공하는 여러 대안을 제시하였다. 또한 보수보강 현장에서 물배출 앵커를 적용할 경우 앵커의 설계하중 적용을 위해 인장강도시험, 인발강도시험을 수행하였고, 배수성능시험을 통해 최적의 성능개선 형 물배출 앵커 및 트랩볼트를 개발하였다.

균열방지 슬리브가 매설된 패널식 옹벽 (Concrete-Panel Retaining Wall anti-crack sleeve inserted)

  • 장성호;정지승
    • 문화기술의 융합
    • /
    • 제5권3호
    • /
    • pp.345-349
    • /
    • 2019
  • 우리나라는 산지가 70% 이상으로 도로, 철도, 산업단지 조성 등의 기반시설 구축시 원지반 일부를 깍아 부지를 형성하는 이른바 깍기 비탈면이 널리 쓰이고 있다. 최근에는 환경 훼손에 대한 규제가 더욱 엄격해져 대규모 깍기 비탈면을 지양하고 최소한의 용지사용으로 목적구조물을 건설하기 위하여 다양한 방법의 공법들이 개발되어 적용되고 있으며, 그 중 활발하게 적용되는 공법이 패널식 옹벽 공법이다. 패널식 옹벽은 지보재 보강을 통한 원지반의 전단강도 증가와 그 지보재 전면에 프리캐스트 옹벽을 체결하여 벽체를 형성시킴으로써 수평토압에 저항하는 공법이다. 지보재는 쏘일네일링, 어스볼트, 그라운드앵커 등이 사용되고 있으며, 그 중 그라운드앵커는 강선에 미리 인장하중을 도입하는 보다 적극적인 보강형태로 전면판인 패널에 큰 집중하중이 작용하게 된다. 이러한 집중하중은 콘크리트 패널에 균열을 발생시키고 옹벽 자체의 내구성을 저해시키는 요인으로 본 연구에서는 이러한 기존 패널식 옹벽의 단점을 보완하기 위하여 패널 정착부에 강관 슬리브 및 보강재를 매입함으로써 균열을 방지하고, 패널 단부에 요철 모양의 전단키를 적용하여 기존 그라우트앵커가 가지는 개별거동에 대한 취약점을 보완하여 안정성을 향상시켰으며, 옹벽 전면 콘크리트 노출 및 정착부 돌출에 의한 경관성 저하문제를 자연석 문양 연출과 정착부를 돌출시키지 않는 단면구성으로 해결하였다. 패널에 사용된 균열방지 슬리브 및 보강재의 효과를 검증하기 위하여 실내시험 및 3차원 수치해석을 수행한 결과, 강관슬리브 및 보강재의 사용으로 패널의 전반적인 강도 증가와 균열억제 효과가 입증되었다.

알루미늄 보강재 적용에 따른 원형 단부 콘크리트 블록의 지압 보강 효과 (Bearing Reinforcing Effect of Concrete Block with a Round End according to the Application of Aluminum Stiffener )

  • 전석현;권태윤;안진희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권3호
    • /
    • pp.38-46
    • /
    • 2023
  • 본 연구에서는 원형 단부 콘크리트의 알루미늄 보강재 적용에 따른 지압 성능을 평가하기 위하여 지압 시험을 수행하고 이를 해석적으로 평가하였다. 지압강도 실험에서는 원형 단부 콘크리트 제작용 알루미늄 거푸집을 이용한 알루미늄 보강재와 부재이동 및 조립을 위한 강재 앵커볼트로 인한 지압성능 변화를 확인하였다. FE 해석모델은 실험조건과 동일하게 구성하여 결과를 실험과 비교하였으며, 균열 양상과 응력 거동 등도 확인하였다. 또한, 알루미늄 보강재의 강도변화가 원형 단부 콘크리트에 미치는 영향도 해석적으로 평가하였다. 원형 단부 콘크리트는 알루미늄 보강재로 인하여 지압강도가 약 20% 증가하였고, 강재 앵커볼트는 지압강도에 영향을 미치지 않는 것으로 확인되었다. FE 해석 결과 나타난 최대 하중과 균열 양상은 실험과 유사하게 나타났다. 알루미늄 보강재의 강도변화에 따른 FE 해석 결과, 알루미늄 보강재의 강도가 10%, 20% 증가 및 감소함에 따른 최대하중 변화는 강도변화 전과 비교하여 최대 약 4% 수준으로 큰 영향이 없는 것으로 평가되었다.