• Title/Summary/Keyword: analyzer

Search Result 4,506, Processing Time 0.029 seconds

Total Mercury Content of Restaurant Meals in Seoul Area (대중음식중의 총 수은 함량 측정)

  • 김명희;정남준;김정헌;박성배
    • Journal of Food Hygiene and Safety
    • /
    • v.4 no.1
    • /
    • pp.21-27
    • /
    • 1989
  • This study was performed to investigate the mercury concentration of restaurant meals and to estimate the total dietary intake of mercury. Experimental subjects were 66 cases in 11 kinds of common restaurant meals collected from the Seoul area. Total mercury was determined by Hg-analyzer and two kinds of atomic absorption spectrophotometer (AAS). The results were as follows: 1. Mean value of mercury contents in fluid of meals was about 0.002 ppm and there was no significant difference between the two methods. 2. Mercury concentration of residue by AAS was significantly higher than that by Hg-analyzer. The mean values of mercury concentration were 2.423 ppm, 10.229 ppm and 11.655 ppm by Hg-analyzer, AAS-PE and AAS-Hi, respectively. 3. Dietary intake of mercury from the meals was estimated $7.806\;\mu\textrm{g}/day$ by Hg-analyzer and 31.290, $35.349\;\mu\textrm{g}/day$ by two kinds of AAS. The values were lower than the FAO/WHO limit, $42.9\;\mu\textrm{g}/day$.

  • PDF

Non-imaging Optical Design of a Measurement Probe for LCD Display Used in a Color Analyzer (LCD 디스플레이용 색채계 렌즈에 관한 비결상 광학설계)

  • Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.5
    • /
    • pp.239-244
    • /
    • 2011
  • We introduce Gaussian (or paraxial) optics that can be successfully applied to design, for use in a color analyzer, a non-imaging optical system on a measurement probe for LCD display. The color analyzer is used to decompose colored lights leaving from some measurement area on the LCD display to red, green, and blue. The color analyzer must include a condenser lens whose purpose is to gather colored lights to illuminate a small area on the sensor. In order to satisfy a reduction ratio between the measurement area and the sensing area with a non-imaging condition, a condenser lens is analytically treated by means of Gaussian optics so that good understanding of the non-imaging condenser lens is achieved as a good design is derived. As a result, the technique shows the necessity of analytical treatment in contrast to the design approach using only commercial software such as CODE-V, Light-Tools, and others. Of course, CODE V and Light-Tools are also utilized in this paper to confirm and complete the Gaussian optical design.

Automatic Decision-Making on the Grade of 6 Year-Old Fresh Ginseng (Panax ginseng C. A. Meyer) by an Image Analyzer II. Decision of Rusty Root of Ginseng (Image Analyzer를 이용한 수삼등급의 자동판정 II. 수삼의 적변판정)

  • 강제용;이명구
    • Journal of Ginseng Research
    • /
    • v.26 no.1
    • /
    • pp.6-9
    • /
    • 2002
  • This study was undertaken to evaluate the automatic decision-making on the rusty root of fresh ginseng (Panax ginseng C.A. Meyer) by an image analyzer. Critical value of rusty root of ginseng by image analyzing was the percentage of grey value 0∼148 area (G 148) to the total area of grey value 0∼255. And the discriminant formula of rusty root of ginseng as follows; rusty root of ginseng : 6.68$\times$G(148) +3.74, normal ginseng : 2.86$\times$G(148) +9.96, and fitness rates of this formula were 89.8%. Also, we developed the automatic rusty root of decision-making program. As the result of this study, the automatic decision-making on the rusty root of fresh ginseng by an image analyzer seems to have high possibility.

Characteristic of the pulse wave in hypertension using pulse analyzer with array piezoresistive sensor (어레이 압저항 센서 장착 맥진기의 고혈압 맥파 특성)

  • Choi, Yong-Seok;Kim, Kyung-Yo;Hwang, Seung-Yeon;Kim, Jong-Yeol;Lee, Si-Woo;Kim, Hyun-Hee;Joo, Jong-Cheon
    • Korean Journal of Acupuncture
    • /
    • v.24 no.3
    • /
    • pp.105-116
    • /
    • 2007
  • Objectives : This study was performed to determine whether a pulse analyzer using array piezoresistive sensor was useful to characterize the variables of pulse wave of hypertentive patients (HT) , compared with those of healthy subjects. Methods : One hundred twenty two subjects participated in this study. Sixty nine subjects had hypertension and fifty three subjects had no specific history or disease associated with hypertension. We used automatic pulse analyzer with array piezoreslstive sensor. Results : Calibrated in Chon, no specific differences was between HT group and the healthy group. Calibrated in Gwan. sum of pulse pressure (SPP) of HT group was higher than that of the healthy group. Calibrated in Cheek, mean of height of main peak (Mm) and height of main peak (h1) of HT group were higher than those of the healthy group. Conclusions : Pulse analyzer was useful to determine the risk degree or development possibility of hypertension.

  • PDF

Development of a Data Bus Analyzer for Avionics Interfaces of Various Types (다종 항공전자 인터페이스를 위한 데이터 버스 분석 장비 개발)

  • Kim, Min-Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.9
    • /
    • pp.825-832
    • /
    • 2016
  • This paper describes the development of a data bus analyzer for use in avionics systems integration test. The data bus analyzer is equipped with MIL-STD-1553B, CAN and Ethernet interface cards which is incorporated in a majority of the avionics systems to accommodate a variety of interfaces. It has an individual hardware for a capture engine and a analyzing engine in order to perform the collection and the analysis of the bus data at the same time efficiently. It provides a data display function of the grid, 2-dimensional and 3-dimensional form to increase the data analysis efficiency. Verification of the data bus analyzer was carried out module unit testing and inter-module integration testing on the basis of the test procedures. Verification of interlocking requirement and usefulness of developed equipment was confirmed through an integration test result performed on a system integration laboratory of aircraft which is an actual testing environment.

An XPDL-Based Workflow Control-Structure and Data-Sequence Analyzer

  • Kim, Kwanghoon Pio
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.3
    • /
    • pp.1702-1721
    • /
    • 2019
  • A workflow process (or business process) management system helps to define, execute, monitor and manage workflow models deployed on a workflow-supported enterprise, and the system is compartmentalized into a modeling subsystem and an enacting subsystem, in general. The modeling subsystem's functionality is to discover and analyze workflow models via a theoretical modeling methodology like ICN, to graphically define them via a graphical representation notation like BPMN, and to systematically deploy those graphically defined models onto the enacting subsystem by transforming into their textual models represented by a standardized workflow process definition language like XPDL. Before deploying those defined workflow models, it is very important to inspect its syntactical correctness as well as its structural properness to minimize the loss of effectiveness and the depreciation of efficiency in managing the corresponding workflow models. In this paper, we are particularly interested in verifying very large-scale and massively parallel workflow models, and so we need a sophisticated analyzer to automatically analyze those specialized and complex styles of workflow models. One of the sophisticated analyzers devised in this paper is able to analyze not only the structural complexity but also the data-sequence complexity, especially. The structural complexity is based upon combinational usages of those control-structure constructs such as subprocesses, exclusive-OR, parallel-AND and iterative-LOOP primitives with preserving matched pairing and proper nesting properties, whereas the data-sequence complexity is based upon combinational usages of those relevant data repositories such as data definition sequences and data use sequences. Through the devised and implemented analyzer in this paper, we are able eventually to achieve the systematic verifications of the syntactical correctness as well as the effective validation of the structural properness on those complicate and large-scale styles of workflow models. As an experimental study, we apply the implemented analyzer to an exemplary large-scale and massively parallel workflow process model, the Large Bank Transaction Workflow Process Model, and show the structural complexity analysis results via a series of operational screens captured from the implemented analyzer.

Photosynthesis and Respiration (P&R) Analyzer Analysis Optimization for Microalgal Activity Evaluation (미세조류 활성도 평가를 위한 Photosynthesis and Respiration (P&R) Analyzer 분석조건 최적화)

  • Huh, Jae-Hee;Sim, Tae-Suk;Hwang, Sun-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.449-457
    • /
    • 2021
  • Photosynthesis and respiration rate of microalgae are important factors during advanced wastewater treatment research using microalgae, There are several equipments and measurement methods for measuring photosynthesis and respiration, with different challenges that occur during pretreatment and stabilization of the analysis process. Therefore, in this study, for accurate Photosynthesis and Respiration (P&R) analyzer measurement, the analysis process was divided into pre-processing, DO stabilization, and analysis stages and each was optimized to enable accurate evaluation. For this purpose, the effect of DO saturation of the sample on P&R analysis, DO stabilization according to the degassing flow rate, and photoinhibition of the OD level on photosynthesis was investigated. Based on our study results, when DO was supersaturated, photosynthetic efficiency decreased due to photorespiration, making it inappropriate as a P&R sample. In addition, 0.5 L-N2/min level was the optimal nitrogen degassing flow rate for DO desaturation. The inhibition of photosynthetic efficiency by self-shading caused by the increase in OD was observed from OD 2.0, and it was found that P& R analysis is preferably performed on samples with OD less than 2.0. In addition, based on the above three optimization results, an optimized P&R Analyzer instruction for accurate P&R analysis was also presented.

Extended Neutral Particle Analyzer System for the KSTAR

  • Kim, Sun-Ho;Gu, Dong-Jin;Park, Min;Ahn, Chan-Yong;Wang, Son-Jong;Kim, Sung-Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.272-272
    • /
    • 2012
  • Additional neutral particle analyzer has been installed to investigate the variation of fast ion tails with regard to the line of sight during 2012 KSTAR campaign. The system has the same photo-diode particle detector as previous system [1]. Both newly installed system and previous system modifield for 2012 campaign have two channels. One has a particle stopper transparent to hard X-ray, the other has no one. It will be used to separate the hard X-ray component from total hard X-ray and fast neutral counts. It is expected to measure fast ion tails more clearly through this extended system. A detailed system and calibration result will be presented in the conference.

  • PDF

Design and Implementation of an optical wavelength analyzer (광파장분석기 설계 및 구현)

  • Park, Sung-Hoon;Park, Jong-Won;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.571-574
    • /
    • 2012
  • optical wavelength analyzer design and implementation of this study is about. For experiments, the input light in the infrared, ultraviolet, visible as a light source was used. I-V Converting circuit configured as a photodiode. I-V Converting circuit voltage is measured. Measured voltage can be determined for a wavelength in size.

  • PDF

Korean Speakers' Pronunciation and Pronunciation Training of English Stops (한국인의 영어 폐쇄음 발화와 발화 훈련)

  • Kim, Ji-Eun
    • Phonetics and Speech Sciences
    • /
    • v.2 no.3
    • /
    • pp.29-36
    • /
    • 2010
  • The purposes of this study are (1) to see if language transfer effect is found in Korean speakers' pronunciation of English stops and to correct them and (2) to investigate the effectiveness of mimicry training and Speech Analyzer training on subjects' pronunciation of English stops. For these purposes, 20 Korean speakers' VOT values of English stops were measured using Speech Analyzer and their post-training production was compared with their pre-training production. The result shows that Korean speakers have no difficulty in correcting pronunciation errors of English voiceless stops and voiced stops and such a result indicates that language transfer effect is not noticed as expected. In addition, the result of pronunciation training shows that the training using Speech Analyzer is more effective than mimicry training.

  • PDF