• Title/Summary/Keyword: analytical testing

Search Result 442, Processing Time 0.044 seconds

Evaluation of seismic performance factors for steel DIAGRID structural system design

  • Lee, Dongkyu;Shin, Soomi;Ju, Youngkyu
    • Earthquakes and Structures
    • /
    • v.10 no.4
    • /
    • pp.735-755
    • /
    • 2016
  • This article presents a proposed analytical methodology to determine seismic force-resisting system R-values for steel diagrid framed systems. As current model building codes do not explicitly address the seismic design performance factors for this new and emerging structural system, the purpose of this study is to provide a sound and reliable basis for defining such seismic design parameters. An approach and methodology for the reliable determination of seismic performance factors for use in the design of steel diagrid framed structural systems is proposed. The recommended methodology is based on current state-of-the-art and state-of-the practice methods including structural nonlinear dynamic analysis techniques, testing data requirements, building code design procedures and earthquake ground motion characterization. In determining appropriate seismic performance factors (R, ${\Omega}_O$, $C_d$) for new archetypical building structural systems, the methodology defines acceptably low values of probability against collapse under maximum considered earthquake ground shaking.

Vibration Analysis for a Fuel Rod Continuously Supported by a Spacer Grid (지지격자 스프링으로 다점 지지된 환형 핵연료봉의 고유 진동 해석)

  • Kang, Heung-Seok;Yoon, Kyung-Ho;Kim, Hyung-Kyu;Song, Kee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.639-646
    • /
    • 2000
  • Estimation for the vibration behavior of a nuclear fuel rod with its supporting structure called spacer grid has been made by the both of experimental and analytical methods in order to compare the supporting performance of two kinds of the spacer grids which have been newly developed. For the analytical method the fuel rod was modeled as a beam continuously supported by the springs of the spacer grid, and ABAQUS computer code was utilized. After a modal testing was performed for the fuel rod supported by five spacer grids, two results has been compared to justify and compensate the both methods. It has been found that the spring design of the spacer grid could give significant effect to natural frequency and vibration amplitude of the fuel rod.

  • PDF

The Effects of Children's Self-perception and Human Rights Recognition in Local Children Center - Focusing on moderation effects of right guarantee and use satisfaction -

  • Rho, Seon-duk;Sim, Mi-young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.2
    • /
    • pp.201-207
    • /
    • 2019
  • The purpose of this study is to suggest some implications by empirical testing the relationships between children's self-perception and human rights recognition in local children's center. For this study, Total 438 children were sampled and surveyed. The analytical results are the followings. First, personal characteristics was shown to have a significant effect to human right recognition. Second, self-perception was shown to have a significant effect to human right recognition. Third, right guarantee of center was shown to moderate the relationship between self-perception and human right recognition. This study provides some theoretical and polcy implications basing on these analytical results.

Study on analysis of PAHs in consumer products (공산품 함유 PAHs 분석법에 관한 연구)

  • Song, Moon Hwan;Cho, Young Dal;Choe, Eun Kyung
    • Analytical Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.201-212
    • /
    • 2014
  • Polycyclic aromatic hydrocarbons (PAHs) that are carcinogenic and persistent will be restricted in consumer products from December 27, 2015 by EU REACH regulation. Pretreatment using Soxhlet extraction and quantitative analysis by GC-MS were studied to develop the method for analyzing 18 PAHs in consumer products as well as to detect the amounts and the kinds of PAHs in consumer products such as grips of a bag and a hammer, a cable and a plastic sandal. Linearity and precisions were evaluated by analyses of the standard PAH solutions ranging from 0.3125 mg/L to 5.00 mg of each of 18 PAHs. Linearity of resulting standard curves for all 18 PAHs were obtained with $R^2$ above 0.999. Precisions of the retention times and the peak areas were found to be 0.00%~0.05% and 1.16%~3.69% of relative standard deviations, respectively. The recoveries for spiked samples were all around 95%~105% after Soxhlet extration using three different solvents such as dichloromethane, hexane and toluene. The limits of quantitation for 18 PAHs in solutions and polymer samples by GC-MS were evaluated to be 0.327 mg/L (Benzo[ghi]perylene)~0.464 mg/L (Acenaphthylene) and 1.635 mg/kg (Benzo[ghi]perylene)~2.32 mg/kg (Acenaphthylene) based upon dilution factor of 5, respectively. Under the developed analytical method, only trace amounts of phenanthrene were detected in three samples while 15 kinds of PAHs including phenanthrene were detected in a grip of hammer with concentrations of maximum 83.4 mg/kg of Phenanthrene and minimum 8.5 mg/kg of Acenaphthylene. Further studies are needed to decrease the quantitation limit and to check the feasibility of decreasing Soxhlet time as well as to demonstrate cases that the clean up is required.

Field testing of a seismically isolated concrete bridge

  • Chang, K.C.;Tsai, M.H.;Hwang, J.S.;Wei, S.S.
    • Structural Engineering and Mechanics
    • /
    • v.16 no.3
    • /
    • pp.241-257
    • /
    • 2003
  • The first seismically isolated structure in Taiwan was completed in early 1999. Seven new bridges of the Second National Freeway located at Bai-Ho area, a region which is considered to be of high seismic risk, have been designed and constructed with lead-rubber seismic isolation bearings. Since this is the first application of seismic isolation method to the practical construction in Taiwan, field tests were conducted for one of the seven bridges to evaluate the assumptions and uncertainties in the design and construction. The test program is composed of ambient vibration tests, forced vibration tests, and free vibration tests. For the free vibration tests, a special test setup composed of four 1000 kN hydraulic jacks and a quick-release mechanism was designed to perform the function of push-and-quick release. Valuable results have been obtained based on the correlation between measured and analytical data so that the analytical model can be calibrated. Based on the analytical correlation, it is concluded that the dynamic characteristics and free vibration behavior of the isolated bridge can be well captured when the nonlinear properties of the bearings are properly considered in the modeling.

Development of Asbestos Quality Contral Samples for Proficiency Analytical Testing II - Evaluation of Amosite and Chrysotile Quality Contral Samples - (석면분석 정도관리용 표준시료 개발연구 II - Amosite 및 Chrysotile 표준시료 평가 -)

  • Yi, Gwang Yong;Yoon, Chung sik;Han, Jin Ku;Yun, Moonjong;Jung, Sijeong;Lee, Jong Han;Lee, In Sub;Park, Doo Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.288-296
    • /
    • 2009
  • We conducted validation for asbestos quality control (QC) samples made by the developed method which was presented in our published paper. The main results of the validation study are as follows. The pooled coefficient variations of analytical results in three different concentrations (low, medium, and high concentration) for amosite and chrysotile were less than 20 %, which met the sample homogenicity criteria of NIOSH. Also we confirmed the homogenicity of asbestos samples by using the relocatable field slide. To evaluate the field applicability of the developed asbestos QC samples, the field validation was performed with four proficient asbestos analysts by using the statistical methods of AIHA asbestos PAT program. All analytical results from four asbestos analysts were located in the acceptable range.

Estimation of conbined uncertainty for dioxin reference materials from the fly ash (소각재에 함유된 다이옥신의 확장불확도 평가)

  • Kim, Woo-Il;Shin, Sun-Kyoung;Lee, Su-Young;Kim, Dong-Hoon;Kang, Hak-Gu;Han, Jin-Suk
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.363-370
    • /
    • 2010
  • This study was performed to validate reference materials (RMs) for proficiency testing (PT) in waste inter-laboratories. Dioxin RMs were prepared from fly ash in industrial incinerators. The relative standard deviations (RSDs) of analytical results were 2.6~15.7% for the dioxin RMs in 10 replicates (between and withinbottles). Data were collected and statistical analysis was performed by the One-way ANOVA test. The combined uncertainties of target isomers in dioxin analysis were 0.114~7.091.

Comparison of Liquid-Liquid Extraction and Solid-Phase Extraction Coupled with GC/MS for Determination of Priority Pollutants in Water (액체 추출법과 고체상 추출법에 의한 수질 중 유해물질 농축법 비교)

  • Yook, Keun-Sung;Hong, Sa-Moon;Kim, Jong-Ho
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.441-453
    • /
    • 1994
  • Two extraction methods, liquid-liquid extraction(LLE) and solid-phase extraction(SPE), coupled with GC/MS were compared as preconcentration procedures for priority pollutants in water. Among the semi-volatile priority pollutants, 11 acid and 44 base/neutral compounds were spiked in reagent water. With LLE, which is a modification of EPA Method 625, the overall mean recovery of the 54 compounds was 91% with a mean relative standard deviation(RSD) of 4.6%. With SPE, the overall mean recovery of the 52 compounds was 53% with a mean RSD of 8.9%. The detection limits of both methods were in the range of $1{\sim}5{\mu}g/l$.

  • PDF

A Study for the Measurement of a fluid Density in a ripe Using Elastic Waves

  • Kim, Jin-Oh;Hwang, Kyo-Kwang;Bau, Haim-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.583-593
    • /
    • 2003
  • The effect of liquid confined in a pipe on elastic waves propagating in the pipe wall was studied theoretically and experimentally. The axisymmetric motion of the wave was modeled with the cylindrical membrane shell theory. The liquid pressure satisfying the axisymmetric wave equation was included in the governing equation as a radial load. The phase speed of the wave propagating in the axial direction was calculated, accounting for the apparent mass of the liquid. Experiments were performed in a pipe equipped with ring-shaped, piezoelectric transducers that were used for transmitting and receiving axisymmetric elastic waves in the pipe wall. The measured wave speeds were compared with the analytical ones. This work demonstrates the feasibility of using pipe waves for the determination of the density and, eventually, the flow rate of the liquid in a pipe.

Ultrasonic Reflection at a Water/Fiber Reinforced Polymer Composite/Water Interface (물/섬유강화 고분자 복합재료/물 경계면에서의 초음파 반사)

  • Lee, J.H.;Lee, S.C.;Jun, J.N.;Oh, S.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 1993
  • This study describes ultrasonic reflection at a water/fiber reinforced polymer composite/water interface. Theoretical predictions of reflected beam amplitudes are also presented. Four different polymer composite laminates are investigated : T300/5208 graphite/epoxy $[0]_{31T},\;[45/90/-45/0]_{3S},\;[45/-45]_{2S}$, and S-2 glass/epoxy $[0/90]_{4S}$. The analytical leaky plate wave dispersion curves for the unidirectional laminate and other three laminates can be obtained by searching for the minimum magnitude of the reflection coefficient.

  • PDF