• 제목/요약/키워드: analytical testing

검색결과 442건 처리시간 0.025초

알루미늄 마이크로 박판소재의 방향성에 관한 실험적 연구 (An experimental study on the oriented mechanical properties of aluminum micro thin foil material)

  • 이혜진;이낙규;최석우;이형욱;최태훈;황재헉;곽동기
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.295-298
    • /
    • 2005
  • This paper is concerned with the precision material property measurement of a micro metal thin foil that is used in MEMS technology. Since these MEMS components require great precision and accuracy, evaluation of reliability such as the lift cycle endurance test, impact test, and residual stress test is necessary for these components. However, in practice, real reliability tests are not easy to perform due to consideration of various factors. Rather than actual testing, it would be much easier to evaluate the reliability of components by the analytical approach. Although the analytical method is utilized by software tools, it is obviously necessary to acquire fundamental properties of materials through real test methods. In this paper, the oriented mechanical properties of aluminum thin foil are measured by nano scale material property measurement system.

  • PDF

Comparison between Field Test and Numerical Analysis for a Jacket Platform in Bohai Bay, China

  • Yang He-Zhen;Park Han-Il;Choi Kyung-Sik;Li Hua-Jun
    • 한국해양공학회지
    • /
    • 제20권2호
    • /
    • pp.1-7
    • /
    • 2006
  • This paper, presents a comparison between numerical analysis and field test on a real offshore platform in Bohai Bay, China. This platform is a steel jacket offshore platform with vertical piles. The field testing under wave-induced force and wind force etc. was conducted, in order to obtain the dynamic parameters of the structure, including the frequencies of the jacket platform, as well as the corresponding damping ratios and mode shapes. The natural excitation technology (NexT) combined with eigensystem realization algorithm (ERA) and the peak picking (PP) method in frequency domain are carried out for modal parameter indentification under operational conditions. The three-dimeansional finite element model (FEM) is constructed by ANSYS and analytical modal analysis is performed to generate modal parameters. The analytical results were compared with experimental results. A good agreement was achieved between the finite element and analysis and field test results. It is further demonstrated that the numerical and experimental modal analysis provide a comprehensive study on the dynamic properties of the jacket platform. According to the analysis results, the modal parameters identification under ambient excitation can calibrate finite element model of the jacket platform structures, or can be used for the structural health monitoring system.

섬유강화 복합재료 내 탄성파 반사현상의 제3임계각 (The Third Critical Angle in Reflection of Elastic Waves in Fiber-reinforced Composites)

  • 임현준;백은솔
    • Composites Research
    • /
    • 제20권1호
    • /
    • pp.15-22
    • /
    • 2007
  • 이 논문에서는 섬유강화 복합재료에서의 초음파의 거동에 대해 파동의 모드, 방향, 자유표면에서의 반사파의 반사계수 등을 예측하는 해석적인 방법을 소개한다. 이 논문은 또한 복합재료의 자유표면에서 반사가 일어날 때의 특이한 현상을 새로이 고찰하였는데, 이는 완도면(slowness surface)만을 고려하면 존재할 것으로 예상되지만 실제로는 존재하지 않는 반사파에 대한 것이다. 이는 입사파가 유사횡파일 경우, 입사각이 이 논문에서 새로 정의된 제3임계각을 넘어설 경우 나타나는 현상이다. 본 논문의 내용은 초음파검사와 같은 해당 분야에 종사하는 연구자들에게 유용한 가이드라인을 제시할 것으로 기대된다.

수산나프로닐 캡슐 및 염산트라마돌 캡슐의 용출시험에 관한 연구 (Development of the Dissolution Tests for Nafronyl Oxalate Capsules and Tramadol Hydrochloride Capsules)

  • 황정분;문현주;고서연;장기욱;이규하;손경희;김인규;조대현
    • 약학회지
    • /
    • 제55권5호
    • /
    • pp.411-418
    • /
    • 2011
  • The dissolution test method and an analytical procedure by HPLC were developed and validated for nafronyl oxalate capsules and tramadol hydrochloride capsules. These drugs were not yet characterized by the dissolution specifications in the Korean Pharmaceutical Codex. So, with each reference and test drugs, we did the preliminary and standard experiments based on the Korean Pharmacopeia Guideline of dissolution testing for solid oral dosage forms. The dissolution test for nafronyl oxalate capsules was carried out under sink conditions as follows: dissolution medium phosphate buffer pH 6.8, paddle rotation speed 100 rpm and vessel volume 900 ml. More than 80% of its label amount was released within 30 min in this method. Also the dissolution test for tramadol hydrochloride capsules was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 50 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 15 min in this method. The dissolution samples were analyzed with a validated HPLC analytical procedure. The analytical methodology showed acceptable values in terms of specificity, linearity, precision and accuracy. The dissolution test methods described above were adequate for the purpose and may be proposed as a pharmacopeial standard to assess the performance of nafronyl oxalate capsules and tramadol hydrochloride capsules. Furthermore, the outcomes of this study were expected to help create an environment where safe and high quality drugs would be distributed on the domestic market making contributions to advancing public health.

터보차져의 로터다이나믹 해석모델 개발 및 진동응답 해석 (Development of Rotordynamic Analytical Model and Analysis of Vibration Response of a Turbocharger)

  • 김병옥;이안성
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.35-42
    • /
    • 2010
  • This paper deals with the development of analytical model of a turbocharger and its detail rotordynamic analysis. Two analytical models, which are verified by experimental modal testing, are proposed and the analytical model including rotor shaft extended to compressor and turbine wheel end side is chosen. A rotordynamic analysis includes the critical map, Campbell diagram, stability, and unbalance response, especially nonlinear transient response considering nonlinear fluid film force at bearings. Although the linearized analysis accurately predicts the critical speeds, stability limit, and stability threshold speed, the predicted vibration results are not valid for speeds above the stability threshold speed since the rotor vibrates with a subsynchronous component much larger than the one synchronous with rotor speed. Hence, for operating speed above the stability threshold, a nonlinear transient analysis considering nonlinear fluid film force must be performed in order to accurately predict vibration responses of rotor and guarantee results of analysis.

An analytical investigation of soil disturbance due to sampling penetration

  • Diao, Hongguo;Wu, Yuedong;Liu, Jian;Luo, Ruping
    • Geomechanics and Engineering
    • /
    • 제9권6호
    • /
    • pp.743-755
    • /
    • 2015
  • It is well known that the quality of sample significantly determines the accuracy of soil parameters for laboratory testing. Although sampling disturbance has been studied over the last few decades, the theoretical investigation of soil disturbance due to sampling penetration has been rarely reported. In this paper, an analytical solution for estimating the soil disturbance due to sampling penetration was presented using cavity expansion method. Analytical results in several cases reveal that the soil at different location along the sample centerline experiences distinct phases of strain during the process of sampling penetration. The magnitude of induced strain is dependent on the position of the soil element within the sampler and the sampler geometry expressed as diameter-thickness ratio D/t and length-diameter ratio L/D. Effects of sampler features on soil disturbance were also studied. It is found that the induced maximum strain decreases exponentially with increasing diameter-thickness ratio, indicating that the sampling disturbance will reduce with increasing diameter or decreasing wall thickness of sampler. It is also found that a large length-diameter ratio does not necessarily reduce the disturbance. An optimal length-diameter ratio is suggested for the further design of improved sampler in this study.

ABS 중 phthalates 가소제 CRM 개발에 대한 연구 (A study on the development of phthalate plasticizers CRM in ABS resin)

  • 정정설;박정우;유석;권성일;홍성택;선일식;박천민;최창휴
    • 분석과학
    • /
    • 제25권5호
    • /
    • pp.273-283
    • /
    • 2012
  • 현재 RoHS 및 REACH, CPSC 등에서 phthalates 가소제를 유해물질로 분류하여 규제하고 있는 실정이다. 이러한 국제환경규제에 대응하기 위해 phthalates 가소제 정량분석용 ABS 인증표준물질을 개발하였으며 인증 대상물질은 DMP, DEP, DBP, BBP, DEHP, DnOP이다. 후보물질은 전기 전자제품에 많이 사용되고 있는 ABS 수지에 phthalates 가소제 6가지 물질을 혼합한 후 쌍축압출기(twin screw extruder)를 이용하여 압출, 냉각, 펠렛, 건조의 과정을 거쳐 제조하였으며 ISO Guide 35의 절차에 따라 인증하였다. 동위원소희석 질량분석법(ID-GC/MS)을 이용하여 균질성, 단기안정성 및 장기안정성을 평가하였으며, 소급성 확립을 위해 한국표준과학연구원(KRISS)의 일차표준물질을 이용하여 인증값을 결정하였다. 향후 인증표준물질로서 인증을 받은 후, 국제 표준물질 데이터베이스(COM AR:code of reference material)에 등록하고 국내 외 산업체 및 시험기관에 보급할 예정이다.

공정분석기술: 제약산업에서의 기술개발 사례 및 현황 (Process analytical technology (PAT): field applications and current status in pharmaceutical industries)

  • 우영아;김종윤;박용준;연제원;송규석;김효진
    • 분석과학
    • /
    • 제22권1호
    • /
    • pp.35-43
    • /
    • 2009
  • 단순히 완제품만을 평가하는 기존의 방법에서 제조 공정의 보다 깊은 이해와 공정 제어를 통한 품질 확보가 PAT (공정분석기술, process analytical technology)가 지향하고 있는 핵심이다. 생산 상 위험 요소가 많이 발생하는 공정을 제어할 수 있는 목적으로 새로운 실시간 공정 제어 기술을 개발하는 것이 PAT 연구 내용이다. 공정 단계에 대한 이해, 공정에 필요한 여러 가지 변수 및 공정 생산품의 평가 기술은 PAT를 수행하기 위한 기술적 핵심 요소이다. 이에 관련하여 다국적 제약회사의 실제 공정에서의 실시간 품질관리 사례는 상당히 많은 것으로 알려져 있으나, 제조공정 및 분석 기술 자체가 기업 비밀인 경우가 많아 관련 정보는 극히 제한되어 있다. 본 총설을 통하여 실제 제약 산업 현장에서 활용되고 있는 적용사례를 소개하고, 각 제조 공정 및 완제품 실시간 품질 관리를 위한 PAT 연구 사례 및 기술개발 현황에 대하여 언급하고자 한다.

고충격폴리스티렌 중 브롬계 난연제 숙련도시험 결과 평가 (Evaluation of the proficiency testing results for brominated flame retardants in high impact polystyrene)

  • 김달호;유제훈;최용욱
    • 분석과학
    • /
    • 제24권6호
    • /
    • pp.435-442
    • /
    • 2011
  • 폴리 브롬화 디페닐 에테르류(PBDEs)는 난연제의 한 종류로서 인체와 생태계에 영향을 미치는 잠재적인 독성물질이며 최근 들어 관심의 대상이 되고 있는 화학물질이다. 유럽연합을 비롯하여 많은 국가들은 전기전자제품에 이 물질의 사용을 제한하고 있다. 이와 관련된 시험소인정을 지원하기 위해 고충격 폴리스티렌(HIPS) 중 PBDE류 측정을 위한 숙련도시험을 ISO/IEC 17043을 기초로 하여 수행하였다. 고충격 폴리스티렌에 포함된 4종의 PBDE류(PBDE-154, 183, 206, 209)를 측정 대상 물질로 하여 숙련도시험이 수행되었다. 10 g의 펠렛형 고충격 폴리스티렌 시료를 35개 참가실험실들에게 배포하였고 실험실들의 능력을 평가하기 위해 z-score를 사용하였다. 숙련도 시험의 결과 및 참가 실험실 평가결과를 기술하였다.

Development and validation of a qualitative GC-MS method for methamphetamine and amphetamine in human urine using aqueous-phase ethyl chloroformate derivatization

  • Kim, Jiwoo;Sim, Yeong Eun;Kim, Jin Young
    • 분석과학
    • /
    • 제33권1호
    • /
    • pp.23-32
    • /
    • 2020
  • Methamphetamine (MA) is the most common and available drug of abuse in Korea and its primary metabolite is amphetamine (AP). Detection of AP derivatives, such as MA, AP, phentermine (PT), MDA, MDMA, and MDEA by the use of immunoassay screening is not reliable and accurate due to cross-reactivity and insufficient specificity/sensitivity. Therefore, the analytical process accepted by most urine drug-testing programs employs the two-step method with an initial screening test followed by a more specific confirmatory test if the specimen screens positive. In this study, a gas chromatography-mass spectrometric (GC-MS) method was developed and validated for confirmation of MA and AP in human urine. Urine sample (500 µL) was added with N-isopropylbenzylamine as internal standard and ethyl chloroformate as a derivatization reagent, and then extracted with 200 µL of ethyl acetate. Extracted samples were analysed with GC-MS in the SIM/ Scan mode, which were screened by Cobas c311 analyzer (Roche/Hitachi) to evaluate the efficiency as well as the compatibility of the GC-MS method. Qualitative method validation requirements for selectivity, limit of detection (LOD), precision, accuracy, and specificity/sensitivity were examined. These parameters were estimated on the basis of the most intense and characteristic ions in mass spectra of target compounds. Precision and accuracy were less than 5.2 % (RSD) and ±14.0 % (bias), respectively. The LODs were 3 ng/mL for MA and 1.5 ng/mL for AP. At the screening immunoassay had a sensitivity of 100% and a specificity of 95.1 % versus GC-MS for confirmatory testing. The applicability of the method was tested by the analysis of spiked urine and abusers' urine samples.