• Title/Summary/Keyword: analytical simulator

Search Result 80, Processing Time 0.027 seconds

Development of Three-Dimensional Ion Implantation Simulator Using Analytical Model (해석모델을 이용한 3차원 이온주입 시뮬레이터 개발)

  • 박화식;이준하;황호정
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.12
    • /
    • pp.43-50
    • /
    • 1993
  • Three-dimensional simulator for the ion implantation process is developed. The simulator based on an analytical model which would be a choice with high computational efficiency and accuracy. This is an important issue for the simulation of a numerous number of processing steps required in the fabrication of ULSI or GSI. The model can explain scattering and bulk channeling mechanism (1D). It can also explain depth dependent lateral diffusion effect(2D) and mask effect(3D). The model is consist of one-dimensional JPD(Joined Pearson Distribution) function and two-dimensional modified Gaussian functions. Final implanted profiles under typical mask structures such as hole, line and island structure are obtained with varying ion species.

  • PDF

Soft Error Rate Simulator for DRAM (DRAM 소프트 에러율 시뮬레이터)

  • Shin, Hyung-Soon
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.55-61
    • /
    • 1999
  • A soft error rate (SER) simulator for DRAM was developed. In comparison to the other SER simulator using device simulator or Monte Carlo simulator, the proposed simulator substantially reduced the CPU time using an analytical model for the alpha-particle-induced charge collection. By analysing the soft error modes in DRAM, the bit-bar mode was identified as the main cause of soft error. Using the new SER simulator, SER of 256M DRAM was investigated and it was found that the storage capacitance had a 5fF margin.

  • PDF

Development of a Nano-Electro-Mechanical Memory Simulator (나노전기기계 메모리 시뮬레이터의 개발)

  • Choi, Woo Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.122-127
    • /
    • 2012
  • A nano-electro-mechanical (NEM) memory simulator has been developed by using Matlab. The simulator can be used for the prediction of hysterisis curves, applied forces, steady- or transient-state behavior, program/erase energy consumption and potential energy. Predicting NEM memory behavior by simple user interface, the simulator will make the design of NEM memory cells simpler.

A Running Stability Test of 1/5 Scaled Bogie Using Small Scale Derailment Simulator (소형탈선시뮬레이터를 이용한 1/5 축소대차의 주행안정성 시험)

  • Eom, Beom-Gyu;Lee, Se-Yong;Lee, Young-Yeob;Kang, Bu-Byoung;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2600-2608
    • /
    • 2011
  • The dynamic stability of railway vehicle has been one of the important issues in railway safety. The dynamic simulator has been used in the study about the dynamic stability of railway vehicle and wheel/rail interface. Especially, a small scale simulator has been widely used in the fundamental study in the laboratory instead of full scale roller rig which is not cost effective and inconvenient to achieve diverse design parameters. But the technique for the design of the small scale simulator for the fundamental study about the dynamic characteristics of the wheel-rail system and the bogie system has not been well developed in Korea. Therefore, the research about the development of the small scale simulator and the bogie has been conducted. As this paper, To predict the dynamic behavior of railway vehicle, we studied running stability test of 1/5 scaled bogie that similarity laws is applied using small scale derailment simulator. For the operation of the small scale derailment simulator, it is required to investigate the performance and characteristics of the system. This could be achieved by a comparative study between an analysis and an experiment. This paper presented the analytical model which could be used for verifying of the test results and understanding of the physical behavior of the dynamic system comprising the small scale bogie and the simulator.

  • PDF

Analytical Modeling for Circuit Simulation of Amorphous Silicon Thin Film Transistors (비정질 실리콘 박막 트랜지스터의 회로 분석을 위한 해석적 모델링)

  • 최홍석;박진석;오창호;한철희;최연익;한민구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.5
    • /
    • pp.531-539
    • /
    • 1991
  • We develop an analytical model of the static and the dynamic characteristics of amorphous silicon thin film transistors (a-Si TFTs) in order to incorporate into a widely used circuit simulator such as SPICE. The critical parameters considered in our analytical model of a-Si TFT are the power factor (XN) of saturation source-drain current and the effective channel length (L') at saturation region. The power factor, XN must not always obey so-called

  • PDF

A Design of Real-time VOD Server Simulator (실시간 VOD 서버 시뮬레이터 설계)

  • 정지영;김성수
    • Journal of the Korea Society for Simulation
    • /
    • v.9 no.3
    • /
    • pp.65-75
    • /
    • 2000
  • In recent years, significant advances in computers and communication technologies have made multimedia services feasible. As a result, various queuing models and cost models on architecture and data placement for multimedia server have been proposed. However, these analytical techniques use only probabilistic models to represent the behavior of a system, and then they have several limitations like accuracy. Simulation is a viable alternative to analytical model. It avoids many of the limitations associated with analytical techniques, allowing for more precise representation of system attributes like workload in program code. In this paper, we propose a simulation test bed that can evaluate performance of real-time multimedia server by using simulation model.

  • PDF

Development of Compressible Three Phases Flow Simulator Based on Fractional Flow Approach (압축성을 고려한 분율 흐름 접근 방식에 근거한 삼상흐름모델 개발)

  • Suk, Hee-Jun;Ko, Kyung-Seok;Yeh, Gour-Tsyh
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.731-746
    • /
    • 2008
  • Most multiphase flow simulators following fractional flow approach assume incompressibility of fluid and matrix or consider only two phase flow (water and air, water and NAPL). However, in this study, mathematical governing equations were developed for fully compressible three-phase flow using fractional flow based approach. Also, fully compressible multiphase flow simulator (CMPS) considering compressibilities of matrix and fluid was developed using the mathematical governing equations. In order to verify CMPS, the CMPS were compared with analytical solution and the existing multiphase flow simulator, MPS, which had been developed for simulating incompressible multiphase flow (Suk and Yeh 2007; Suk and Yeh 2008). According to the results, solutions of CMPS and MPS and analytical solutions are well matched each other. Thus, it is found that CMPS has the capability of simulating compressible three phase flow phenomena assuming compressibilities of fluids and matrix.

Performance Evaluation of OGS-FLAC Simulator for Coupled Thermal-Hydrological-Mechanical Analysis (열-수리-역학적 연계해석을 위한 OGS-FLAC 시뮬레이터의 성능 평가)

  • Park, Dohyun;Park, Chan-Hee
    • Tunnel and Underground Space
    • /
    • v.32 no.2
    • /
    • pp.144-159
    • /
    • 2022
  • The present study developed a sequential approach-based numerical simulator for modeling coupled thermal-hydrological-mechanical (THM) processes in the ground and investigated the computational performance of the coupling analysis algorithm. The present sequential approach linked the two different solvers: an open-source numerical code, OpenGeoSys for solving the thermal and hydrological processes in porous media and a commercial code, FLAC3D for solving the geomechanical response of the ground. A benchmark test of the developed simulator was carried out using a THM problem where an analytical solution is given. The benchmark problem involves the coupled behavior (variations in temperature, pore pressure, stress, and deformation with time) of a fully saturated porous medium which is subject to a point heat source. The results of the analytical solution and numerical simulation were compared and the validity of the numerical simulator was investigated.

Application of OMA on the bench-scale earthquake simulator using micro tremor data

  • Kasimzade, Azer A.;Tuhta, Sertac
    • Structural Engineering and Mechanics
    • /
    • v.61 no.2
    • /
    • pp.267-274
    • /
    • 2017
  • In this study was investigated of possibility using the recorded micro tremor data on ground level as ambient vibration input excitation data for investigation and application Operational Modal Analysis (OMA) on the bench-scale earthquake simulator (The Quanser Shake Table) for model steel structures. As known OMA methods (such as EFDD, SSI and so on) are supposed to deal with the ambient responses. For this purpose, analytical and experimental modal analysis of a model steel structure for dynamic characteristics was evaluated. 3D Finite element model of the building was evaluated for the model steel structure based on the design drawing. Ambient excitation was provided by shake table from the recorded micro tremor ambient vibration data on ground level. Enhanced Frequency Domain Decomposition is used for the output only modal identification. From this study, best correlation is found between mode shapes. Natural frequencies and analytical frequencies in average (only) 2.8% are differences.

OMA of model chimney using Bench-Scale earthquake simulator

  • Tuhta, Sertac
    • Earthquakes and Structures
    • /
    • v.16 no.3
    • /
    • pp.321-327
    • /
    • 2019
  • This study investigated the possibility of using the recorded micro tremor data on ground level as ambient vibration input excitation data for investigation and application Operational Modal Analysis (OMA) on the bench-scale earthquake simulator (The Quanser Shake Table) for model chimney. As known OMA methods (such as EFDD, SSI and so on) are supposed to deal with the ambient responses. For this purpose, analytical and experimental modal analysis of a model chimney for dynamic characteristics was performed. 3D Finite element model of the chimney was evaluated based on the design drawing. Ambient excitation was provided by shake table from the recorded micro tremor ambient vibration data on ground level. Enhanced Frequency Domain Decomposition is used for the output only modal identification. From this study, best correlation is found between mode shapes. Natural frequencies and analytical frequencies in average (only) 1.996% are different.