• 제목/요약/키워드: analytical instrument

검색결과 129건 처리시간 0.023초

국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (I) (Evaluation of the Possession of Measurement and Analytical Instruments among Domestic Work Environment Monitoring Service Providers (I))

  • 장재길
    • 한국산업보건학회지
    • /
    • 제23권3호
    • /
    • pp.250-260
    • /
    • 2013
  • Objectives: The aim of this study is to analyze the current status of the possession of measurement and analytical instruments among work environment monitoring organizations that have been designated by the Ministry of Employment and Labor (MoEL) in Korea. Methods: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency (KOSHA) and MoEL during the evaluation program for designated work environment monitoring service providers in 2012. Data for 11 monitoring instruments and nine analytical instruments were collected from 108 organizations. Basic data such as the type of service provides and the size of employment were also recorded by the inspector. Results: The total number of personal air samplers including high and low flow rates operated in Korea was 5,418, with average of 50.2. Average operation number of noise dosimeters was 35.0, while 3,780 dosimeters were used in 108 work environment monitoring organizations. There were 10,488 monitoring instruments in total. All service providers possessed at least one AAS and GC in their analytical laboratory. Total number of HPLC/MS was five, followed by ICP/MS of seven, with an average of 0.07. Conclusions: Based on the data, domestic work environment monitoring service providers possessed relatively reasonable measurement and analytical instruments. Nearly all instruments had been imported from advanced countries such as USA, UK and Japan. Periodic gathering of data on these instruments may help maintain good workplace monitoring results and the health of workers at the sites.

Standardized Design of the Transmitting Coils in Inductive Coupled Endoscope Robot Driving Systems

  • Ke, Quan;Jiang, Pingping;Yan, Guozheng
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.835-847
    • /
    • 2017
  • A transmitting coil with an optimal topology and number of turns can effectively improve the performance of the wireless power transfer (WPT) systems for endoscope robots. This study proposes the evaluation parameters of the transmitting coils related to the performance of the WPT system to standardize the design of the transmitting coils. It considers both the quality factor of transmitting coils and the coupling factor between the two sides. Furthermore, an analytical model of transmitting coils with different topologies is built to exactly estimate the evaluation parameters. Several coils with the specified topologies are wound to verify the analytical model and the feasibility of evaluation parameters. In the case of a constant power received, the related evaluation parameters are proportional to the transfer efficiency of the WPT system. Therefore, the applicable frequency ranges of transmitting coils with different topologies are determined theoretically. Then a transmitting coil with a diameter of 69 cm is re-optimized both theoretically and experimentally. The transfer efficiency of the WPT system is increased from 3.58% to 7.37% with the maximum magnetic field intensity permitted by human tissue. Finally, the standardized design of the transmitting coil is achieved by summing-up and facilitating the optimization of the coils in various situations.

국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (II) (Evaluation of the Possession of Measurement and Analytical Instruments in Domestic Work Environment Monitoring Service Providers (II))

  • 장재길
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.182-192
    • /
    • 2014
  • Objectives: The aim of this study is to analyze the current status of possession of measurement and analytical instruments at work environment monitoring organizations and their relationships with human resources, including the number of professional engineers and evaluation scores resulting from evaluation programs in 2012. Materials: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency(KOSHA) and the Ministry of Employment and Labor(MoEL) during the evaluation program for 2012. Data for 11 monitoring instruments and nice pieces of analytical equipment were collected from 103 organizations. Additional data such as the type of service provides and the number of professional engineers employed were also recorded by the inspectors. Evaluation scores could be acquired from KOSHA. Results: Comprehensive Occupational Health Service Providers showed good operation quality, while University or Hospital Subsidiary and Work Environment Monitoring Organizations recorded relatively poor results. Evaluation scores correlated well with the possession of measurement instruments and human resources for each organization. High yields provided by professional engineers also showed statistically-associated contributions to evaluation scores and monitoring instrument possession. Compared with monitoring instruments, the amount of analytical equipment had little positive impact on organizations' competence. Conclusions: The evaluation results for domestic monitoring organizations revealed that human resources, possession of instruments, and the quality of employees were critical factors for operating the corporations. Each organization should give considerable effort to improving their ability to strengtheninternal quality, resulting in high-yield production for workers and employers by providing improved workplace monitoring services.

A Digitized Decoupled Dual-axis Micro Dynamically Tuned Gyroscope with Three Equilibrium Rings

  • Xia, Dunzhu;Ni, Peizhen;Kong, Lun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.385-395
    • /
    • 2017
  • A new digitized decoupled dual-axis micro dynamically tuned gyroscope with three equilibrium rings (TMDTG) is proposed which can eliminate the constant torque disturbance (CTD) caused by the double rotation frequency of a driving shaft with a micro dynamically tuned gyroscope with one equilibrium ring (MDTG). A mechanical and kinematic model of the TMDTG is theoretically analyzed and the structure parameters are optimized in ANSYS to demonstrate reliability. By adjusting the thickness of each equilibrium ring, the CTD can be eliminated. The digitized model of the TMDTG system is then simulated and examined using MATLAB. Finally, a digitized prototype based on FPGA is created. The gyroscope can be dynamically tuned by adjusting feedback voltage. Experimental results show the TMDTG has good performance with a scale factor of $283LSB/^{\circ}/s$ in X-axis and $220LSB/^{\circ}/s$ in Y-axis, respectively. The scale factor non-linearity is 0.09% in X-axis and 0.13% in Y-axis. Results from analytical models, simulations, and experiments demonstrate the feasibility of the proposed TMDTG.

식이보충제로 사용되는 히알루론산의 분석법에 대한 불확도 산정 (Measurement Uncertainty for Analytical Method of Hyaluronic Acid Used as a Dietary Supplement)

  • 박상욱;김형범;김광준;이원재
    • KSBB Journal
    • /
    • 제32권1호
    • /
    • pp.54-62
    • /
    • 2017
  • This study aimed to estimate the measurement uncertainty related to determination of hyaluronic acid used as a dietary supplement by high-performance liquid chromatography. According to the guidelines of the Association of Official Analytical Chemists, the analytical processes for determination of hyaluronic acid were performed. And the measurement uncertainty obtained during the analytical processes were expressed in accordance with mathematical/ statistical guidances of GUM (Guide to the Expression of Uncertainty in Measurement) & EURACHEM (Focus for Analytical Chemistry in Europe) for the analytical operations. For the uncertainty in measurement produced based on this analytical method, the expanded uncertainty was calculated by using the relative standard uncertainty between analytical results and sources of uncertainty in measurement (sample weight, final volume, extraction volume, standard solution, matrix and instrument etc). In the results of 95% confidence interval, it was calculated that the uncertainty in measurement was $57.75{\pm}8.76{\mu}g/kg$ (k=2.0). Therefore, it showed that the measurement uncertainty obtained by this analytical method influences on 15.2% of the contents of hyaluronic acid as the analytical results.

GC/MS분석자료의 목표물질 인식에 관한 연구 (A Study on the Identification of Target Compounds From the GC/MS Data)

  • 민홍기;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.223-228
    • /
    • 1989
  • In this paper, the computerized interpretation of the analytical chemical data, especially GC/MS data, was performed for the purpose of prescreening of the target compounds. First, the data from the analytical instrument was analyzed to get the information about the retention time of the ISTD and the time inteval between the records. Second, the identification of the characteristic ion peaks was performed by calculating the ratio of the heights and the relative slope sensitivity of the characteristic mass abundance.

  • PDF

작업환경측정 지정기관의 분석실 현황 및 분석결과의 신뢰성에 영향을 주는 요인 (Current status of working environment monitoring the designated organization's laboratory and factors affecting reliability of the analysis results)

  • 김기웅;박해동;김성호;노지원;황은송;정은교;조기홍
    • 한국산업보건학회지
    • /
    • 제28권1호
    • /
    • pp.108-116
    • /
    • 2018
  • Objectives: This study investigated to the analytical work environment, analyst's expert and status of analytical instrument in the designated organization's laboratory for measuring work environment, and carried out to ensure reliability of analytical results. Methods: This study was conducted by 114 analysts who work in designated organization's laboratory for measuring work environment. Information on the working environment and personal characteristics of the analysts were collected using a self-reported questionnaire and were analyzed using the SPSS program through analysis of frequency and t-test. Results: The speciality of subjects was occupational health(57.0%), environmental health(38.6%) and environmental engineering(4.4%), and they had a higher level of academic ability than workers in other industries. Analysts had to handle a large number of sample analysis and many tasks other than analytical work. The analysts answered that it was difficult to analyze organic substances than inorganic substances, and the difficult parts were the analytical methods setting of new substances(55.3%), instrument analysis(24.6%) and principle of analysis(23.7%). Analytical instruments mainly have legally required instruments. The difficulty of the analysis is solved from the senior analyst in the laboratory and analytical information is mainly exchanged through seminar organized by the Association of Occupational Health Analysts. The analysts who are planning to move or considering the company were 48.2%, and the reasons for moving the company were difficult to work(14.0%), low salary(9.6%), employment type(8.8%) and job stress(7.0%). Conclusions: The conclusions of our study were that it was possible to secure reliability by solving the problems such as implementing professional education to improve expertise of analysts, strengthening analytical instruments through institutional improvement and improving work environment.

임상보고 가능범위의 실증적 연구 (An Empirical Study of the Clinically Reportable Range in Clinical Chemistry)

  • 장상우;이상곤;최호성;송은영;박용원;이인애
    • 대한임상검사과학회지
    • /
    • 제39권1호
    • /
    • pp.31-36
    • /
    • 2007
  • The purpose of the clinically reportable range (CRR) in clinical chemistry is to estimate linearity in working range. The reportable range includes all results that may be reliably reported, and embraces two types of ranges: the analytical measurement range (AMR) is the range of analyte values that a method can directly measure on the specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. CAP and JCAHO require linearity on analyzers every six months. The clinically reportable range is the range of analyte values that a method can measure, allowing for specimen dilution, concentration, or other pretreatment used to extend the direct analytical measurement range. The AMR cannot exceed the manufacturer's limits. Establishing AMR is easily accomplished with Calibration Verification Assessment and experimental Linearity. For example: The manufacturer states that the limits of the AST on their instrument are 0-1100. The lowest level that could be verified is 2. The upper level is 1241. The verified AMR of the instrument is 2-1241. The lower limit of the range is 2, because that is the lowest level that could be verified by the laboratory. The laboratory could not use the manufacturer's lower limit of 2 because they have not proven that the instrument values below 2 are valid. The upper limit of the range is 1241, because although the lab has shown that the instrument is linear to 1241, the manufacturer does not make that claim. The laboratory needs to demonstrate the accuracy and precision of the analyzer, as well the validation of the patient AMR. Linearity requirements have been eliminated from the CLIA regulations and from the CAP inspection criteria, however, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. If a lab chooses to continue linearity studies, these studies must fully comply with the calibration/calibration verification requirements of CLIA and/or CAP. The results of lower limit and upper limit of clinically reportable range were total protein (2.1 - 79.9), albumin (1.3 - 39), total bilirubin (0.2 - 106.2), alkaline phosphatase (13 - 6928.2), aspartate aminotransferase (24 - 7446), alanine aminotransferase (13 - 6724.2), gamma glutamyl transpeptidase (16.64 - 9904.2), creatine kinase (15.26 - 4723.8), lactate dehydrogenase (127.66 - 13231.8), creatinine (0.4 - 129.6), blood urea nitrogen (8.67 - 925.8), uric acid (1.6 - 151.2), total cholesterol (48.52 - 3162), triglycerides (36.91 - 3367.8), glucose (31 - 4218), amylase (21 - 6694.2), calcium (3.1 - 118.2), inorganic phosphorus (1.11 - 108), HDL (11.74 - 666), NA (58.3 - 1800), K (1.0 - 69.6), CL (38 - 1230).

  • PDF