• Title/Summary/Keyword: analytical equipment

검색결과 280건 처리시간 0.021초

건설기계 엔진 시스템의 가진력 예측 모델 개발 (A Study of the excitation force of an engine system for construction equipment)

  • 김우형;김성재;김인동
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.654-657
    • /
    • 2014
  • In this paper, we study the analytical method to predict the excitation forces for the engine system. The engine system on the construction equipment is one of the important power sources, and the characteristics of the engine decide the performance of noise and vibration for the equipment. We predict the excitation forces using the geometrical data of the crank system and the combustion pressure in the cylinder. The excited forces are represented by the torque fluctuation above the center of the crank shaft.

  • PDF

기기 기초 시스템의 지렛대 효과 해석 (The Analysis of Prying Action for Equipment Anchor System.)

  • 김강식;유원진;김갑순;서용표
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.83-90
    • /
    • 2002
  • Prying action caused by the eccentric loads within the equipment itself and the anchors can result in a lack of adequate stiffness and strength within the equipment and in additional moment loadings on the anchors. A typical case of prying action often found in power plants is the angle type anchorage system with expansion bolt. Experimental and analytical studies were performed to investigate the relationship between the amplification factors and various geometrical and material factors. It is revealed that the value of the factor is effected by the stiffness of bolt and angle, lateral stiffness of cabinet, and geometrical parameter of anchor system.

  • PDF

주파수 응답함수를 이용한 고정밀장비의 진동 허용규제치 결정기법에 관한 연구 (A Study on the Determination Vibration criteria for High Technology Facilities using FRF - Impact Test-)

  • 이홍기;박해동;김두훈;김사수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.377-385
    • /
    • 1996
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. the former is accurate but requires a great deal of time and efforts while the latter lacks reliability. this paper proposes a new method to solve this problem at a time. the permissible vibration level to a precision equipment can be easily obtained by analyzing a process of Frequency Response Function. This paper also demonstrates its effectiveness by applying the proposed method to finding the vibration criteria of a Computer Hard Disk Drive by impact Test.

  • PDF

사진기준점측량을 이용한 저등급 기준점의 좌표결정 (Coordinates Determination of tow Level Control Point by Aerial Triangulation)

  • 최재화;이석배;최윤수
    • 한국측량학회지
    • /
    • 제6권2호
    • /
    • pp.34-41
    • /
    • 1988
  • 오늘날 항공사진측량은 사용기재와 자료처리방법의 발달과 더불어 위치결정의 정확도가 날로 향상되고 있으며, 지상기준점측량을 하지 않고서 GPS를 이용한 사진기준점측량 방안이 모색되는 단계에 이르렀다. 해석도화기의 등장은 정확도와 효율성면에서 상당한 발전을 가능케 하였고 On-Line System의 구성을 통해서 사진 기준점측량의 작업환경을 크게 개선시켰다. 본 연구에서는 해석도화기를 이용한 사진기준점측량을 실시하여 저등급 측지기준점의 좌표결정에 있어서 정확도의 향상을 그 목표로 하고 있다. 연구결과 정확도 향상의 정도는 기존의 정밀도화기를 사용한 A.T.의 경우와 비교할 때에 평면에서 약 7%, 표고에서 약 40%의 정확도 향상을 가져왔다.

  • PDF

Buckling of simply supported thin plate with variable thickness under bi-axial compression using perturbation technique

  • Fan, Haigui;Chen, Zhiping;Wang, Zewu;Liu, Peiqi
    • Structural Engineering and Mechanics
    • /
    • 제70권5호
    • /
    • pp.525-534
    • /
    • 2019
  • An analytical research on buckling of simply supported thin plate with variable thickness under bi-axial compression is presented in this paper. Combining the perturbation technique, Fourier series expansion and Galerkin methods, the linear governing differential equation of the plate with arbitrary thickness variation under bi-axial compression is solved and the analytical expression of the critical buckling load is obtained. Based on that, numerical analysis is carried out for the plates with different thickness variation forms and aspect ratios under different bi-axial compressions. Four different thickness variation forms including linear, parabolic, stepped and trigonometric have been considered in this paper. The calculated critical buckling loads and buckling modes are presented and compared with the published results in the tables and figures. It shows that the analytical expressions derived by the theoretical method in this paper can be effectively used for buckling analysis of simply supported thin plates with arbitrary thickness variation, especially for the stepped thickness that used in engineering widely.

주파수 응답함수를 이용한 고정밀 장비의 진동허용규제치 결정기법에 관한 연구 (A Study on the Vibration Criteria Decision for High Technology Facilities using FRF)

  • 이홍기;김두훈;김사수
    • 소음진동
    • /
    • 제6권3호
    • /
    • pp.363-373
    • /
    • 1996
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in promotion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. The former is accurate but requires a great deal of time and efforts while the latter lacks reliability. This paper proposes a new method to solve this problem at a time. The permissible vibration level to a precision equipment can be easily obtained by analyzing the process of Frequency Response Function(FRF). This paper also demonstrates its effectiveness by applying the proposed method to finding the permissible vibration criteria of a Computer Hard Disk Drive.

  • PDF

충격시험을 이용한 고정밀장비의 진동허용규제치 결정기법에 관한 연구 (A Study on the Determination of Vibration Criteria for Vibration Sensitive Equipments Using Impact Test)

  • 이홍기;박해동;김두훈;김사수
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.247-254
    • /
    • 1997
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. This paper proposes a new method to solve this problem at a time. The permissible vibration level to a precision equipment can be easily obtained by analyzing a process of Frequency Response Function. This paper also demonstrates its effectiveness by applying the proposed method to finding the vibration criteria of a Computer Hard Disk Driver by Impact Test.

  • PDF

3차원 자계해석을 통한 GIS 모선의 와전류에 의한 온도 상승 (30 Magnetic Analysis on Temperature Rise Resulting from Induced Eddy current In Gas Insulated Switchgear)

  • 이방욱;손종만;강종성;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2274-2276
    • /
    • 1999
  • In this work, temperature rise and eddy current distribution on the enclosure and conductor of 3 pole gas insulated switchgear were investigated using analytical and experimental measures. The design of the diameters of the conductors and the enclosures of a meal clad gas insulated switchgear is primarily based on the insulation requirements. It is very difficult problem to predict the temperature rise of enclosed switchgear due to the complexity of the phenomena of heat transfer and existence of eddy current loss. To overcome this situations, we focused on the eddy current distribution on the enclosure of switchgear caused by high current 3 pole conductor as a fundamental basis. The experimental results about temperature distribution of 3 pole gas insulated switchgear were reported and measurements are compared with predictions of three-dimensional thermal model for eddy current analysis. As a result, three dimensional numerical analysis found to be in close relationship with experimental results and thermal model is efficient to predict the abnormal temperature rise in switchgear.

  • PDF

15층 철근콘크리트 건물에 설치된 통신설비 면진장치 동적 거동에 대한 실험적 연구 (An Experimental Study on the Dynamic Behavior of the Seismic Isolator for Telecommunication Equipment Installed in a 15-Story Reinforced Concrete Building)

  • 최형석;정동혁;서영득;백은림
    • 한국지진공학회논문집
    • /
    • 제25권6호
    • /
    • pp.241-249
    • /
    • 2021
  • Communication facilities play an essential role in disaster situations. Therefore, communication facilities need to have structural and functional safety during and after earthquakes. Recently, technology for partial seismic isolation has been increasing to protect data facilities and communication equipment installed in buildings from earthquakes. However, excessive displacement may occur in the seismic isolator during an earthquake due to the resonance between the building and the seismic isolator having long-period characteristics, which may cause overturning and separation of the installed equipment. In this study, analytical and experimental studies were conducted to evaluate the safety of seismic isolators installed in high-rise buildings. It was confirmed that damages might occur in buildings' seismic isolator, with resonance characteristics of less than 1 Hz.

The Impact of Applying Technical Equipment on the Quality of e-Learning at Northern Border University

  • Alenezi, Dr. Ahmed Maajoon
    • International Journal of Computer Science & Network Security
    • /
    • 제22권2호
    • /
    • pp.261-271
    • /
    • 2022
  • The study aimed to identify the impact of the application of technical equipment for infrastructure to achieve the quality of e-learning for students in the faculties at Northern Border University, in Arar city. The study applied the analytical survey study method. To achieve the study purpose, the researcher prepared a study tool which is a questionnaire to measure the impact o of applying technical instrument for the infrastructure to achieve the quality of e-learning for students. The study sample size reached (218) students from both groups from the university faculties in Arar city. The results of the study revealed a tendency in the study sample's responses to the availability of the majority of the questionnaire criteria significantly. This indicates the positive impact of the application of technical equipment on the infrastructure to achieve the application quality of e-learning at Northern Border University, the study recommended the following: The need to pay attention to measuring the quality of electronic courses every two years in addition to the need to adjust the quality standards of e-content provided through e-learning platforms. Also, there is the gradual application of e-learning at the university in addition to spreading the culture of e-learning quality among all groups of the university community. Also, it is necessary to direct them towards benefiting from the advantages of e-learning that observes quality standards.