• 제목/요약/키워드: analytical equipment

검색결과 280건 처리시간 0.032초

계층분석법을 이용한 도로관리장비 운영의 효율성 평가 (Evaluation for Operational Efficiency of Road Management Equipment using Analytical Hierarchy Process)

  • 양충헌;김인수
    • 한국도로학회논문집
    • /
    • 제14권5호
    • /
    • pp.157-164
    • /
    • 2012
  • PURPOSES: Regional offices of the Ministry of Land, Transport and Maritime Affairs use a computerized system called KAMIS so as to manage road equipment systematically. Road agencies can record number of operating days by equipment, actual working hours, accumulated operating hours (or distance) by equipment, and operating cost. However, KAMIS does not provide critical information, although it is strongly related to efficient road management equipment operation. In other words, road agencies do not know whether they have sufficient equipment to handle their actual work. METHODS: Therefore, this study suggests a methodology to evaluate for operational efficiency of road management equipment using analytical hierarchy process(AHP). First of all, estimated weights related criteria can be produced by AHP, and then use operational history by pieces of equipment. RESULTS: Results show that importance of management work can differ from weather conditions through five areas. CONCLUSIONS: Commonly, this results can imply to help save money for the purchase and maintenance of road management equipment, and they would improve the functional performance of KAMIS.

Buckling of axial compressed cylindrical shells with stepwise variable thickness

  • Fan, H.G.;Chen, Z.P.;Feng, W.Z.;Zhou, F.;Shen, X.L.;Cao, G.W.
    • Structural Engineering and Mechanics
    • /
    • 제54권1호
    • /
    • pp.87-103
    • /
    • 2015
  • This paper focuses on an analytical research on the critical buckling load of cylindrical shells with stepwise variable wall thickness under axial compression. An arctan function is established to describe the thickness variation along the axial direction of this kind of cylindrical shells accurately. By using the methods of separation of variables, small parameter perturbation and Fourier series expansion, analytical formulas of the critical buckling load of cylindrical shells with arbitrary axisymmetric thickness variation under axial compression are derived. The analysis is based on the thin shell theory. Analytic results show that the critical buckling load of the uniform shell with constant thickness obtained from this paper is identical with the classical solution. Two important cases of thickness variation pattern are also investigated with these analytical formulas and the results coincide well with those obtained from other authors. The cylindrical shells with stepwise variable wall thickness, which are widely used in actual engineering, are studied by this method and the analytical formulas of critical buckling load under axial compression are obtained. Furthermore, an example is presented to illustrate the effects of each strake's length and thickness on the critical buckling load.

지반-구조물-설비 상호작용을 고려한 지진응답 특성에 관한 해석적 연구 (An Analytical Study on Seismic Response Characteristics Considering Soil-Structure-Equipment Interaction)

  • 오현준;김유석
    • 한국지진공학회논문집
    • /
    • 제27권6호
    • /
    • pp.253-263
    • /
    • 2023
  • Non-structural elements, such as equipment, are typically affixed to a building's floor or ceiling and move in tandem with the structure during an earthquake. Seismic forces acting upon non-structural elements traverse the ground and the building's structure. Considering this seismic load transmission mechanism, it becomes imperative to account for the interactions between soil, structure, and equipment, establishing seismic design procedures accordingly. In this study, a Soil-Structure-Equipment Interaction (SSEI) model is developed. Through seismic response analysis using this model, how the presence or absence of SSEI impacts equipment behavior is examined. Neglecting the SSEI aspect when assessing equipment responses results in an overly conservative evaluation of its seismic response. This emphasizes the necessity of proposing an analytical model and design methodology that adequately incorporate the interaction effect. Doing so enables the calculation of rational seismic forces and facilitates the seismic design of non-structural elements.

서울2호선 TCMS 무선지상장치 개발 및 시험결과에 대한 고찰 (The Study about TCMS Wireless Depot Analytical Equipment Development and Test Results at SeoulMetro Line2)

  • 김도훈;서상준;한정수;김철호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.353-362
    • /
    • 2008
  • Operation data and fault data are recorded at the TCMS(Train Control and Monitoring System) of train are very important record for repairs and inspection of train. there are two ways to transfer the data today. one is using memory card and the other is using wireless communications. This paper is proposed about TCMS wireless depot analytical equipment that transfers data recorded in train to depot equipment via wireless method. The TCMS wireless depot equipment configuration is an AP(Access Point) and a central server PC at depot equipment. This method has the advantage of decrease of personnel expenses, collection time and convenience of staffs. This paper is verified about the utility of use, efficient establishment position of an AP at depot, the safety of data receiving, the exactitude of data and the shortening of transmission time. and this equipment is now operating at shin-jeong depot of SeoulMetro.

  • PDF

파워시프트 변속기 유압클러치시스템의 해석적 연구 (An Analytical Investigation of a Hydraulic Clutch System of Powershift Transmission)

  • 이재천
    • 유공압시스템학회논문집
    • /
    • 제6권1호
    • /
    • pp.25-31
    • /
    • 2009
  • This study presents an analytical model of hydraulic clutch system of a power shift transmission to analyze pressure modulation characteristics. A typical hydraulic clutch system was modeled by using AMESim in which the parameters of major components were measured for simulation. Test apparatus was established using the components of power shift and power shuttle clutches with instrumental equipment. The results of simulation and experiment were so close that the proposed analytical model in this study was validated. However the cylinder model analogized clutch dynamics need to be improved in future study. The effects of parameters of orifice diameter, accumulator stroke and oil temperature on pressure modulation were analyzed respectively. The results of parameter sensitivity analysis show that modulation time and set pressure can be easily adjusted by changing parameter values. It is also found that the hydraulic clutch system used in this study is so susceptible to oil temperature that cooling equipment is necessary.

  • PDF

The effects of work environment monitoring organization's analysts' equipment and chemical substance incident response to the safety management awareness

  • Park, Hyun-A;Choi, Seo-Yeon;Rie, Dong-Ho
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권5호
    • /
    • pp.97-103
    • /
    • 2017
  • In this paper, we propose a method to investigate the safety consciousness of a analyst incident response. This study conducted a statistical survey on 154 analysts who hired as expert in environment monitoring organizations in South Korea. The results of the analyses showed that respondents had good awareness on the equipment incident response and complied with laboratory safety regulations very well. Secondly, respondents were aware of the importance in the order of equipment incident response, an analytical laboratory incident response, and the cause of a chemical substance associated incident in an analytical laboratory in regarding the regulation compliance for creating a safe laboratory environment and the securement of laboratory safety. Therefore, (it was identified that) it would be necessary to create a safe environment and integrate a safety management system.

납-고무베어링을 적용한 제어장치의 동적평가를 위한 해석적 연구 (Analytical Study to Determine the Dynamic Property of Control Equipment Room using LRB)

  • 김우범;김대곤;이경진;박병구
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.473-480
    • /
    • 2003
  • In these days, The base isolation system is often used improve the seismic capacity of the structure Instead of conventional techniques of strengthening the structural members. The purpose of this study is to evaluate dynamic property evaluation of control equipment using Lead Rubber Bearing. In this study, analysis numerical was performed to determine the optimal dynamic property of lead rubber bearing and damper which minimize the response of base from in main control room. Also the analytical results was composed with the test results peformed in previous study

  • PDF

국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (II) (Evaluation of the Possession of Measurement and Analytical Instruments in Domestic Work Environment Monitoring Service Providers (II))

  • 장재길
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.182-192
    • /
    • 2014
  • Objectives: The aim of this study is to analyze the current status of possession of measurement and analytical instruments at work environment monitoring organizations and their relationships with human resources, including the number of professional engineers and evaluation scores resulting from evaluation programs in 2012. Materials: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency(KOSHA) and the Ministry of Employment and Labor(MoEL) during the evaluation program for 2012. Data for 11 monitoring instruments and nice pieces of analytical equipment were collected from 103 organizations. Additional data such as the type of service provides and the number of professional engineers employed were also recorded by the inspectors. Evaluation scores could be acquired from KOSHA. Results: Comprehensive Occupational Health Service Providers showed good operation quality, while University or Hospital Subsidiary and Work Environment Monitoring Organizations recorded relatively poor results. Evaluation scores correlated well with the possession of measurement instruments and human resources for each organization. High yields provided by professional engineers also showed statistically-associated contributions to evaluation scores and monitoring instrument possession. Compared with monitoring instruments, the amount of analytical equipment had little positive impact on organizations' competence. Conclusions: The evaluation results for domestic monitoring organizations revealed that human resources, possession of instruments, and the quality of employees were critical factors for operating the corporations. Each organization should give considerable effort to improving their ability to strengtheninternal quality, resulting in high-yield production for workers and employers by providing improved workplace monitoring services.

제조국가별 국가연구시설장비 구축 현황에 따른 국산연구장비 산업 활성화 정책 제언: 기초·분석과학 분야 중심으로 (Policy Suggestions for Korean Research Equipment Industry According to the State of Construction of National Research Facility and Equipment by Country of Manufacture : Focusing on Basic and Analytical Science Field)

  • 김창용;정태원;공재현;서인수;박찬수
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.322-333
    • /
    • 2019
  • 본 연구의 목적은 과거 14년간 한국 정부가 투자한 연구시설 장비의 구축정보를 기반으로 제조국가별로 기초 분석과학 분야의 연구시설 장비 구축 수와 구축금액 차이를 비교 분석하여 국산연구장비의 시장규모와 시장점유의 수준을 알아보고자 하였다. 2019년 1월 1일을 기준으로 2005년부터 2018년까지 국내에 구축되고, 기초 분석과학 분야에 활용되는 연구시설 장비(구축금액이 3천만원 이상인 주장비 기준) 20,687점의 구성, 장비표준분류, 구축 수, 그리고 구축금액을 제조국가별로 분석하였다. 제조국가별 연구시설 장비 구축 수 차이를 비교 분석하기 위하여 단일표본 카이제곱검정 방법을, 구축금액 차이를 비교 분석하기 위하여 일요인 분산분석 방법과 본페로니 사후검정 분석을 사용하였다. 본 연구결과, 각 제조국가별로 연구시설 장비 구축 수(p<.001)와 구축금액(p<.05)은 통계학적으로 유의하게 차이가 있었으며 특히, 장비표준분류에 따라 국내 기업의 연구시설 장비 점유 규모가 통계학적으로 유의하게 상이하였다(p<.05). 따라서 기초 분석과학 분야에 대한 연구장비 국산화 정책 지원 시, 장비유형 및 구축금액별로 정부의 차별화된 전략과 함께 상이한 정책연구 기획이 필요할 것으로 사료된다.

연면방전의 특성과 절연체의 영향 및 그 응용 (A Study on the Effects of Insulating Material Barrier on the Surface Creepage over Discharge)

  • 이승원
    • 전기의세계
    • /
    • 제19권2호
    • /
    • pp.12-17
    • /
    • 1970
  • In the design of electrical equipment insulation, it is customary to place pressboard and other insulating material at right angle to the electrical discharge path, which is based on the insulation tests performed on equipment under various conditions such as types of insulation, applied voltage and other unique situations. Since electrical equipment manufacturing started only recently, there is a scarcity of available data on insulation problems, which make it difficult for the design engineers. The author untook this study to provide such analytical design data for various conditions based on the experiment conducted on the equipment being manufactured, thus reducing possible errors in the process.

  • PDF