• Title/Summary/Keyword: analysis system

Search Result 69,940, Processing Time 0.111 seconds

Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films (사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름)

  • Jang Ji-Sun;Shin Dong-Oh;Choi Byung-Ock;Lee Tae-Kyu;Choi Ihl-Bohng;Kim Moon-Chan;Kwon Soo-Il;Kang Young-Nam
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • The accuracy of the dosimetry in the Cyberknife system is accomplishing important role from all processes of the stereotactic radiosurgery. In this study, we estimated relative output factors for Cyberknife. All measurements were peformed by six different detectors: diode detector, X-Omat V film, Gafchromic EBT film, 0.015 cc, 0.125 cc and 0.6 cc ionization chamber The diode detector and three ionization chambers peformed using water phantom at 80 cm SSD and 1.5 cm depth. When the film measurements were peformed, the water phantom was replaced with a solidwater phantom. Each collimator normalized with respect to the output factor of the largest collimator (60 mm). For the collimators over than 30 mm, the output factors from the different detectors showed a good agreement within 0.5% except 0.6 cc ion chamber For the collimators less than 15 mm, there were substantial differences In the output factors among different detectors. That is, the value of output factor for the 5 mm collimator of a diode and Gafchromic film was each $0.656{\pm}0.009$ and $0.777{\pm}0.013$. In the ion chamber and diode detector, those difference were due to the presence of large dose gradients and lack of electronic equilibrium in narrow megavoltage x-ray beams Therefore, the Gafchromic EBT film were considered more accurate than the others detectors.

  • PDF

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times (호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Woong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • The gated RapidArc may produce a dosimetric error due to the stop-and-go motion of heavy gantry which can misalign the gantry restart position and reduce the accuracy of important factors in RapidArc delivery such as MLC movement and gantry speed. In this study, the effect of stop-and-go motion in gated RapidArc was analyzed with varying gating window time, which determines the total number of stop-and-go motions. Total 10 RapidArc plans for treatment of liver cancer were prepared. The RPM gating system and the moving phantom were used to set up the accurate gating window time. Two different delivery quality assurance (DQA) plans were created for each RapidArc plan. One is the portal dosimetry plan and the other is MapCHECK2 plan. The respiratory cycle was set to 4 sec and DQA plans were delivered with three different gating conditions: no gating, 1-sec gating window, and 2-sec gating window. The error between calculated dose and measured dose was evaluated based on the pass rate calculated using the gamma evaluation method with 3%/3 mm criteria. The average pass rates in the portal dosimetry plans were $98.72{\pm}0.82%$, $94.91{\pm}1.64%$, and $98.23{\pm}0.97%$ for no gating, 1-sec gating, and 2-sec gating, respectively. The average pass rates in MapCHECK2 plans were $97.80{\pm}0.91%$, $95.38{\pm}1.31%$, and $97.50{\pm}0.96%$ for no gating, 1-sec gating, and 2-sec gating, respectively. We verified that the dosimetric accuracy of gated RapidArc increases as gating window time increases and efforts should be made to increase gating window time during the RapidArc treatment process.

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.

Antioxidant Activity and Component Analysis of Fermented Lavandula angustifolia Extracts (라벤더 발효추출물의 항산화 활성과 성분 분석)

  • Park, Soo-Nam;Ahn, You-Jin;Won, Bo-Ryoung;Kang, Myung-Kyu;Kim, Jai-Hyun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.2
    • /
    • pp.125-134
    • /
    • 2009
  • In this study, the antioxidative effects, inhibitory effects on tyrosinase, and component of non-fermented and fermented Lavandula angustifolia extracts were investigated. The ethyl acetate fraction of fermented extract (5.95 ${\mu}g/mL$) showed the most prominent the free radical (1,1-diphenyl-2-picrylhydrazyl, DPPH) scavenging activity ($FSC_{50}$). Reactive oxygen species (ROS) scavenging activities ($OSC_{50}$) of L. angustifolia extracts on ROS generated in $Fe^{3+}-EDTA/H_2O_2$ system were investigated using the luminol-dependent chemiluminescence assay. The ethyl acetate fraction of fermented extract (1.45 ${\mu}g/mL$) showed the most prominent ROS scavenging activity. The protective effects of extract/fractions of L. angustifolia on the rose-bengal sensitized photohemolysis of human erythrocytes were investigated. The L. angustifolia extracts suppressed photohemolysis in a concentration dependent manner (1 ${\sim}$ 50 ${\mu}g/mL$). The inhibitory effect of L. angustifolia extracts on tyrosinase was investigated to assess their whitening efficacy. Inhibitory effects ($IC_{50}$) on tyrosinase were determined with ethyl acetate fraction of L. angustifolia extract (144.80 ${\mu}g/mL$) and ethyl acetate fraction of fermented extract (122.40 ${\mu}g/mL$). Fractions of ethyl acetate and fermented extracts showed both 3 band in TLC and 3 peaks, 2 peaks in HPLC (340 nm), respectively. In each chromatography, fractions of ethyl acetate both from non-fermented and fermented L. angusfifolia have rosmarinic acid in common. These results indicate that the component and content of non-fermented and fermented extracts of L. angustifolia are different. Both of the extract of L. angustifolia can be used as an antioxidant.

Mean Field Analysis of Exchange Coupling in Amorphous RE$Fe_2$-B (RE=Dy, Sm) Alloy Ribbons (비정질 RE$Fe_2$-B (RE=Dy, Sm) 합금 리본에서 평균장 이론에 의한 교환상호작용 계산)

  • Lee, J. M.;J. K. Jung;S.H. Lim
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.85-96
    • /
    • 2001
  • Experimental magnetization-temperature curves for melt-spun ribbons of amorphous alloys (Dy$\_$0.33/Fe$\_$0.67/)$\_$1-x/B$\_$x/(x=0 ,0.05, 0.1, and 0.15) and (Sm$\_$0.33/Fe$\_$0.67/)$\_$1-x/B$\_$x/(x=0, 0.01, 0.02, and 0.03) (in atomic fraction) are fitted with theoretical equations based on the mean field theory in order to calculate exchange couplings between constituent elements as a function of the B content. In the case of the DyFe$_2$-B system, the sign of the exchange coupling between Dy and Fe is negative, indicating that the magnetization direction of Dy is antiparallel to that of Fe. The sign of the other two couplings are positive indicating a parallel alignment. The exchange coupling between Fe ions are greatest, while that between Dy ions is negligible. In the case of the SmFe$_2$B alloys, the sign of all the couplings are positive, indicating ferromagnetic coupling between the spins. The exchange couplings between Fe ions, and Fe and Sm are comparable to each other, but they are much greater than that between Sm ions. The high exchange coupling between Fe and Sm, which is considered to occur indirectly, is rather unexpected, but it is considered to be unique characteristics of amorphous Sm-Fe alloys. In both alloy systems, the exchange coupling between Fe ions increases with increasing B content. and this may be explained by the increase of the Fe-Fe separation with increasing B content. The exchange coupling between Fe and RE also increases with increasing B content. As the B content increases, the magnetization decreases over the whole temperature range, and the Curie temperature also decreases.

  • PDF

Anti-inflammatory effects of Ishige sinicola ethanol extract in LPS-induced RAW 264.7 cell and mouse model (LPS로 유도된 RAW 264.7 Cell과 마우스 모델에 대한 넓패(Ishige sinicola) 에탄올 추출물의 항염증 효과)

  • Kim, Ji-Hye;Kim, Min-Ji;Kim, Koth-Bong-Woo-Ri;Park, Sun-Hee;Cho, Kwang-Su;Kim, Go-Eun;XU, Xiaotong;Lee, Da-Hye;Park, Ga-Ryeong;Ahn, Dong-Hyun
    • Food Science and Preservation
    • /
    • v.24 no.8
    • /
    • pp.1149-1157
    • /
    • 2017
  • Inflammation is the first response of the immune system to infection or irritation in our body. The use of medicinal plants has been widely applied as an alternative source for drug development. One of marine natural resources, the anti-inflammatory effect of Ishige sinicola ethanol extract (ISEE), was evaluated by using LPS-induced RAW 264.7 cell and mice model. As a result, the production of nitric oxide (NO) and pro-inflammatory cytokines (IL-6, IL-$1{\beta}$, TNF-${\alpha}$) were inhibited with increasing concentration of ISEE without any cytotoxicity. Furthermore, ISEE suppressed the expression of not only inducible nitric oxide synthase (iNOS), cyclooxygenase-2 (COX-2), nuclear factor-kappa B (NF-${\kappa}B$) p65, and mitogen-activated protein kinases (MAPKs), including extracellular signal-regulated kinase (ERK) 1/2, p38, and c-Jun N-terminal kinase (JNK) in a dose-dependent manner. In mice ear edema test, the formation of edema was reduced at the highest dosage of ISEE and the reduction of the number of infiltrated mast cells was observed in histological analysis. These results indicate that ISEE has a potent anti-inflammatory activity and can be used as a pharmaceutical material for many kinds of inflammatory disease.

Empirical Study of Key Factors in Satisfaction with Subway Services (지하철 이용만족도 결정요인에 관한 실증적 연구 -서울지역을 중심으로-)

  • Shim, Jong-Seop;Jeon, Ki-Heung
    • Korean Business Review
    • /
    • v.13
    • /
    • pp.49-66
    • /
    • 2000
  • Despite the fact that understanding customers satisfaction with transportation services is a subject of great importance, authors, so far, found no systematic researches referred to that issue. From this point, studying the satisfaction with subways services can be extremely useful. Empirical study of key factors in the satisfaction with subway services is the departure point, which holds as objectives, and we believe, will contribute to overall increasing in the number of subways services used and in the amount of public benefits derived from that usage. In order to achieve these goals: First, several items referred to some key factors in the satisfaction of subway usage were systemized. Second, a research of specific weights attached to those key factors by subway passengers was conducted. Knowledge of the satisfaction variables system can provide deep insights into ones perceptual experience when using a subway. The results were as follows: Various interrelated factors compose a passengers satisfaction with subway services. People do not just use subway passively; a number of key factors, like physical and personal services, exact timing, easiness to access etc. determine the passengers satisfaction with subway. In order to find out specific weights of these key factors multiple regression analysis was employed. Results showed that satisfaction with subway is determined by (in order of importance) easiness to access, quality of physical services, friendliness of working stuff and timing exactness. According to the findings, passengers do not use subway as a simple mean of transportation, rather they perceive it as a complex combination of environmental elements and overall satisfaction depends on these various factors. Therefore, to learn passengers satisfaction with subways services, passengers subway experience must be thoroughly studied and analyzed, and this is where papers value resides.

  • PDF

Synaptic Organization of Vibrissa Afferent Terminals in the Trigeminal Interpolar Nucleus (삼차신경중간핵에서 저역치기계자극수용기 유래 들신경섬유 종말의 연접양상)

  • Ahn, Hyoung-Joon;Paik, Sang-Kyoo;Bae, Yong-Chul;Choi, Jong-Hoon;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.87-106
    • /
    • 2005
  • In order to evaluate the mechanism of transmission as well as processing of sensory information originating from low-threshold mechanoreceptor in oral and maxillofacial region at primary synaptic region of trigeminal nervous system, vibrissa afferent fibers of adult cat were labeled with intra-axonal HRP injection. Serial sections containing labeled boutons were obtained from the piece of trigeminal interpolar nucleus. Under electron microscope, total 30 labeled boutons were observed, and ultrastructural characteristics, frequency of occurence, synaptic organizations of vibrissa afferent terminals were analysed. The results were as follows: 1. Labeled boutons contained clear, spherical synaptic vesicles with diameter of 45$\sim$55nm. They formed asymmetrical synapse with dendrites showing definite postsynaptic density, larger synaptic cleft, multiple synaptic structures at various regions. With unlabeled axon terminals(p-ending) containing polymorphic synaptic vesicles, they formed symmetrical synapse showing indefinite postsynaptic density and narrower synaptic area. 2. Each labeled bouton formed 1 to 15 synapses, the average of 4.77$\pm$3.37 contacts per labeled bouton, with adjacent neuronal profiles. Relatively complex synaptic organization, which formed synapses with more than 5 neuronal profiles, was observed in a large number(46.7%, n=14) of labeled boutons. 3. Axo-somatic synapse was not observed. The number of axo-dendritic synapse was 1.83$\pm$1.37 per labeled bouton. Majority(85.0%) of axo-dendritic synapses were formed with dendritic shafts, nonprimary dendrites(n=47, 1.57$\pm$1.38/1 bouton), however, synapses formed with primary dendrites(n=6, 0.20$\pm$0.41/1 bouton) or dendritic spines(n=2, 0.07$\pm$0.25/1 bouton) were rare. 4. 76.7%(n=23) of labeled boutons formed axo-axonic synapse (2.93$\pm$2.36/1 bouton) with p-endings containing pleomorphic vesicles. Synaptic triad, in which p-endings formed synapses with labeled boutons and dendrites adjacent to the labeled boutons simultaneoulsy, were also observed in 60.0%(n=18) of labeled boutons. From the above results, vibrissa afferent terminals of adult cat showed distinctive synaptic organization in the trigeminal interpolar nucleus, thus, suggests their correlation with the function of the trigeminal interpolaris nucleus, which participates in processing of complex sensory information such as two-point discrimination and motivational-affective action. Further studies on physiologic functions such as quantitative analysis on ultrastructures of afferent terminals and nerve transmitters participating in presynaptic inhibition are required.

An Ecological Comparison of Benthic Macroinvertebrate Community in Downstream Region of Large Dams (대형댐 하류지역 저서성 대형무척추동물 군집의 생태학적 비교)

  • Kim, Jae-Sung;Lee, Hwang-Goo;Choi, Jun-Kil
    • Korean Journal of Environment and Ecology
    • /
    • v.27 no.1
    • /
    • pp.52-63
    • /
    • 2013
  • Benthic macroinvertebrates were investigated in Yongdam-dam and Hapcheon-dam resions from June to October 2011, Korea. Yongdam-dam and Hapcheon-dam are geographically contiguous, but they are classified as other water system. Experiment site(YE-1, 2, 3; HE-1, 2, 3) which is thought to be affected by dam, control site(YC-1, 2; HC-1, 2) which is thought not to be affected by dam were selected. Species composition, macroinvertebrate communities, composition of the functional feeding groups, habitat orientied groups and community stability were assessed Yongdam-dam and Hapcheon-dam regions. Ten sites were selected for quantitative(Surber sampler $30cm{\times}30cm$) of benthic macroinvertebrates. As a results, a total of 6,369 individuals including 69 species, 33 families, 12 orders, 6 classes and 4 phyla were recognized in Yongdam-dam region. Also, a total of 5,728 individuals including 81 species, 44 families, 13 orders, 5 classes and 4 phyla were recognized in Hapcheon-dam region. Dominance index was 0.27~0.50(mean${\pm}$SD $0.38{\pm}0.09$), diversity index was 2.22~2.97($2.67{\pm}0.29$), evenness index was 0.63~0.76($0.72{\pm}0.06$) and richness index was 4.43~7.06($5.69{\pm}0.99$) in Yongdam-dam region. Dominance index was 0.40~0.81($0.59{\pm}0.18$), diversity index was 1.40~2.39($2.00{\pm}0.43$), evenness index was 0.38~0.68($0.56{\pm}0.13$) and richness index was 4.04~5.80($4.95{\pm}0.70$) in Hapcheon-dam region. In the functional feeding groups, filtering-collectors and gathering-collectors were the highest in the whole sites. In the habitat orientied groups, burrowers, clingers and swimmers were considerably occupied in all sites. As a result of community stability analysis, experiment sites has been identified much as species high resistance and resilience to environmental changes in Yongdam-dam. Control sites has been identified much as species low resistance and resilience to environmental changes in Hapcheon-dam. Species belonging to the Igroup is considered to be important in the river ecosystem stability of large dams downstream areas.