• Title/Summary/Keyword: anaerobic digester

Search Result 139, Processing Time 0.022 seconds

Waste Activated Sludge Digestion with Thermophilic Attached Films (친열성(親熱性) 생물막공법(生物膜工法)을 이용(利用)한 폐활성(廢活性) 슬러지의 혐기성(嫌氣性) 소화(消化))

  • Han, Ung Jun;Kabribk, R.M.;Jewell, W.J.
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.4
    • /
    • pp.31-44
    • /
    • 1985
  • The application of anaerobic attached microbial films in the expanded bed process has recently been examined at high temperatures ($55^{\circ}C$) and with particulate matter. Extrapolation of the kinetics suggested that waste activated sludge (WAS) could be efficiently digested at hydraulic retention times as short as six hours in the expanded bed process. This would represent a 99 percent digester reactor volume reduction and would introduce interesting solids management alternatives if such a high rate process were developed. This paper presents a summary of a 1.5 year study of the feasibility of such a process. Three continuously fed $55^{\circ}C$ laboratory reactor systems were used to define the kinetics and the site of reactions-control completely mixed reactors were compared to the expanded beds (AAFEB) with and without a hydrolysis unit preceding the attached film unit. Well defined laboratory-generated WAS was compared to actual WAS from a domestic sewage treatment facility. Sixty percent of the biodegradable organics were converted in an AAFEB at a 15-hour hydraulic retention time without hydrolysis, whereas greater than 95 perccent of the biodegradable organics were stabilized in a two-stage system consisting of a 3-day HRT hydrolysis reactor followed by a 15-hour HRT AAFEB. The limitations of this high rate process and its potential application are discussed.

  • PDF

Applicability Evaluation of Nitritation with Various Wastewater (다양한 하수를 대상으로 아질산화 반응 적용성 평가)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • As the seriousness of water pollution resulted from nitrogen is being magnified, research has been conducted to reduce nitrogen in sewage as well as wastewater. Particularly research on innovative nitrogen removal methods that are based on the reaction of nitritation and are economically feasible and eco-friendly has been receiving attention. However, research on the applicability and efficiency of the methods based on the reaction of nitritation has not been completely done yet. Accordingly, the current study has analyzed the characteristics of sewage flowing into municipal wastewater treatment plants, primary clarifier supernatant, recycled water, and livestock wastewater and also operated a laboratory-level reactor. The result shows that recycled water and livestock wastewater contain higher-concentration nitrogen than other kinds of sewage, so they increase nitrogen loading in the water treatment line. And the result of operating a reactor shows that because of ammonium nitrogen low concentration, sewage and primary clarifier supernatant do not induce the reaction of nitritation. Also, there exist differences in the conditions of retention time inducing the reaction of nitritation by the types of sewage, and this seems to be attributed to organic compound and ammonium nitrogen concentration. Among the kinds of sewage inducing the reaction of nitritation, anaerobic digester supernatant indicates the highest efficiency.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power generation and Stream - Design and Operation Guideline (바이오가스 이용 기술지침 마련을 위한 연구(III) - 기술지침(안) 중심으로)

  • Moon, HeeSung;Bae, Jisu;Pack, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.95-103
    • /
    • 2018
  • As a guideline for desulfurization and dehumidification pretreatment facility for optimizing utilization of biogas, the $H_2S$ concentration is set at 150 % which can be treated with iron salts, dehumidification is the optimum value for generator operation, and the relative humidity applied at the utilization of biogas in EU is set at 60 %. We have set up the generator facility guidelines to optimize utilization of biogas. The appropriate amount of biogas should be at least 90 % of the total gas generation, and the capacity of generator facility should be set at 20~30 %. In order to equalize the pressure of the incoming gas the generator, a gas equalization tank should be installed and the generator room average temperature should be kept at $45^{\circ}C$ or less. Since the gas is not produced at a certain methane concentration in the digester, the efficiency is lowered. Therefore, it is required to install an air fuel ratio control system according to the change in methane concentration. Therefore, it is necessary to compensate for the disadvantages of biogasification facilities of organic waste resources and optimize utilization of biogas and improve operation of facilities. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure), investigate the facilities problem and propose design, operation guidelines such as pre-treatment facilities and generators.

Enhanced Acidification Efficiency of Sewage Sludge by Seaweed Addition (해조류 첨가를 통한 하수슬러지 산발효 효율 증대)

  • Shin, Sang-Ryong;Lee, Mo-Kwon;Kim, Min-Gyun;Hong, Seong-Min;Kim, Dong-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.1
    • /
    • pp.15-21
    • /
    • 2017
  • In the present work, the synergistic effect of seaweed addition on organic acid production from sludge was investigated. The batch experiment was conducted at various mixing ratios of sewage sludge and seaweed (100:0, 75:25, 50:50, 25:75, 0:100 on a COD basis) under the substrate concentration of 20 g COD/L. The fermentation temperature was conducted under mesophilic condition ($35^{\circ}C$) and a heat-treated ($90^{\circ}C$ for 20 min) anaerobic digester sludge was used as a seeding source to suppress the methanogenic activity, The results showed that the amount of organic acid production increased as the content of seaweed increased: organic acids were 1.45, 3.22, 4.28, 5.24 and 4.82 g COD/L for the mixing ratio of 100:0, 75:25, 50:50, 25:75 and 0:100 respectively. The synergistic effect was calculated based on the organic acid production of individual sludge and seaweed, and was found to be 0.92, 1.14, 1.26 g COD/L at the mixing ratio of 75:25, 50:50 and 25:75, which indicates that 40% of synergy was obtained when 25% of seaweed was added. The synergistic effect could be ascribed to the high C/N ratio and biodegradability of seaweed.

Reduction of Highly Concentrated Perchlorate in Aqueous Medium by Newly Isolated Bacterial Strains Rhodococcus sp. YSPW01 and YSPW02 (신균주 Rhodococcus sp. YSPW01과 YSPW02를 이용한 수중 내 고농도 Perchlorate 환원 특성 연구)

  • Lee, Sang-Hoon;Hwang, Jae-Hoon;Akhil, Kabra;Lee, Dae Sung;Jeon, Byong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.352-358
    • /
    • 2014
  • The feasibility of perchlorate reducing-bacteria isolated from the sludge of an anaerobic digester was determined using ammonium perchlorate in aqueous medium. Growth kinetics of the two perchlorate reducing bacteria including Rhodococcus sp. YSPW01 and YSPW02 were investigated using acetate as the electron donor in batch experiment. The growth of YSPW01 and YSPW02 reached a steady-state at 26 and 9 h, respectively. The initial perchlorate concentration was completely reduced within 8 and 7 h by YSPW01 and YSPW02, respectively. The reduction rates were 2.1 and $15mg\;L^{-1}h^{-1}$ for YSPW01, and 3.2 and $15.5mg\;L^{-1}h^{-1}$ for YSPW02, at 1:1 and 5:1 ratios of acetate:perchlorate (w:w), respectively. In this study, the bacteria Rhodococcus sp. YSPW01 and YSPW02 demonstrated a potential for the perchlorate reduction, which could be further investigated for development of an efficient strategy to treat the perchlorate contaminated waters.

Pre-Treatment of Sewage Sludge by Hydrodynamic Cavitation-II: Enhancement of Digestion Efficiency (수리동력학적 캐비테이션을 이용한 하수 슬러지의 전처리-II: 소화효율 향상)

  • Maeng, Jang-Woo;Lee, Eun-Young;Bae, Jae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.3
    • /
    • pp.264-270
    • /
    • 2010
  • Waste activated sludge from sewage treatment plants mainly consisted of flocs of bacterial cell, and thus hard to be stabilized anaerobically due to rigid cell walls. One of the pretreatment methods to overcome this barrier is the venturi cavitation system (VCS) adopting hydrodynamic cavitation. This research was conducted to investigate the effects of the pretreatment of waste activated sludge by VCS on the anaerobic digestibility. Depending on the pretreatment period with the VCS, methane production, COD removal and VS removal efficiency increased 41%~45%, 36.5%~43.1% and 18.4~24.1%, respectively, compared to the control case. The increase in methane production from digester was 3.3~4.2 times higher than the theoretical methane potential of the increased SCOD after the VCS pre-treatment. This suggests that the VCS pre-treatment not only increases SCOD but also improves the digestibility of solid fractions. The energy mass balance indicated that the energy consumed for sludge pre-treatment could be recovered by the increased methane production after pre-treatment, suggesting the high potential for field application.

A Semi-Pilot Test of Bio-barrier for the Removal of Nitrate in Bank Filtrate (강변여과수의 질산성질소 제거를 위한 생물학적 반응벽체의 준파일럿 실험에 관한 연구)

  • Moon, Hee-Sun;Chang, Sun-Woo;Nam, Kyoung-Phile;Kim, Jae-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.302-308
    • /
    • 2005
  • Nitrate is one of common contaminants frequently found in the bank filtrate. Biological autotrophic denitrification into permeable reactive barrier(PRB) system to reduce nitrate concentration in bank filtrate was implanted. The objectives of research are to investigate effect of inoculation, to evaluate alternative alkalinity sources, and to determine effect of hydraulic characteristics, such as retention time, flow rate on the performance of semi-pilot PRB system. Semi-pilot scale biological PRB system was installed using elemental sulfur and limestone/oyster shell as reactive materials near Nakdong River in Kyoungnam province, Korea. Nitrate concentration in bank filtrate was reduced by indigenous microorganisms in oyster shell as welt as by inoculating microorganisms isolated from the sludge of an anaerobic digester in a wastewater treatment plant. Oyster shell as well as limestone can be used as an alkalinity source. However, oyster shell resulted in suspended solids of effluent. As the flow rate in the system increased from 66 to 132 mL/min and accordingly the residence time decreased from 15 to 7.5 hours, nitrate concentration in effluent increased and nitrate removal efficiencies decreased from 75 to 58% at the fixed thickness of 80 cm of PRB.

Biogas production using organic waste (유기성 폐기물을 이용한 바이오가스 생산)

  • Yoo, Eunsil;Hong, Soonhyouk;Kim, Daeyoung;Jun, Haks
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.110.2-110.2
    • /
    • 2011
  • 바이오가스 생산은 현재 정부에서 추진하고 있는 저탄소 녹색성장으로 인해 더욱 그 가치의 중요성이 부각되고 있다. 스웨덴 Scandinavian Biogas Fuel AB(SBF) 사의 바이오 가스 생산 기술을 이용함으로 소화효율을 개선하고 바이오가스 발생량을 극대화하였다. 전국 403개 공공하수처리시설 중 소화조가 설치된 처리시설은 65 개소이며 이중 57 개소에서 총 64개 소화조를 운영 중이다. 하지만 국내 소화조의 효율은 유입수질 저하, 운영, 관리 미숙으로 인해 전진국의 1/4 수준으로 에너지 이용률이 미미한 편이다. 환경부는 2010년부터 에너지 이용, 생산사용 확대, 추진을 위해 하수처리시설별 이용 가능한 에너지 잠재력의 종류, 양, 지역 내 수요자, 공급자 의 현황 규모 등을 정리해 2012년부터 에너지 이용사업 확대를 추진한다. SBF의 기술을 바탕으로 하수처리시설에서 들어오는 하루 슬러지 $1370m^3$와 음식물쓰레기 180t을 함께 처리하며 바이오가스 생산량을 더욱 늘렸다. 각 $7,000m^3$의 달걀모양(egg shape) 소화조 2개를 운영하며 생 슬러지와 음식물 쓰레기 처리 후 바로 소화조로 투입, 혐기 소화하는 방식이며 슬러지 최종처분방법은 탈수 후 소각된다. 반입되는 생 슬러지의 평균 TS 1.7%, VS 63% 이며 농축 후에는 평균 TS 9%, VS 75% 이다. 또 소화조로 들어가는 음식물 쓰레기는 평균 TS 8%, VS 85% 이며 소화 후 평균 TS 3.6% VS 59% 이다. 그리고 소화조의 pH는 7.3~7.8,유기산의 농도는 150mg/L~350mg/L, 가스발생량은 하루 평균 $26,500Nm^3$이며 소화효율은 평균 67%이다. 혐기성소화는 산소가 없는 무 산소 상태 에서 분해 가능한 유기물을 분해시켜 메탄으로 전환시키고 우리는 현재 이 가스를 소화조 가온에 사용하고, 판매하고 있다. 소화효율을 높이기 위하여 가온과 교반이 행해지는데 가온방식은 직접가온방식(증기주입식)과 간접가온방식(열교환방식)이 있다. 그중 우리는 간접가온방식을 채택하여 소화효율을 높였고 일반중온 혐기소화온도보다 약간 높은 $38^{\circ}C$로 운전한다. 그리고 일반적으로 알려진 교반방식인 가스교반, 기계교반, 이 둘은 병행한 교반이 아닌 독자적인 방법을 이용, 소화조 내의 슬러지가 정체되어 교반되지 않는 부분을 최소화 하였다. 이때 미생물이 투입되기 힘든 소화조 아래 쪽 으로도 고루분포 되어 슬러지를 이용 하게 되고 소화조 상하부의 온도차가 $1^{\circ}C$ 이하로 거의 완벽한 교반상태를 보여 줌 으로써 소화효율을 최대한으로 한다. 더욱이 소화일수 부족으로 인한 전반적 소화효율 저하가 발생하지 않도록 input과 output 조절을 통한 적정소화일수 20~25일을 최대한 맞추어 운전하여 소화조 설계용량의 평균 90%를 활용하고 있다.

  • PDF

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power generation and Stream - Results of the Precision Monitoring (바이오가스 이용 기술지침 마련을 위한 연구(II) - 정밀모니터링 결과 중심으로)

  • Moon, HeeSung;Bae, Jisu;Park, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.1
    • /
    • pp.65-78
    • /
    • 2018
  • According to the in social aspects such as population growth, urbanization and industrialization, development of livestock industry by meat consumption, amount of organic wastes (containing sewage sludge and food waste, animal manure, etc) has been increased annually in South Korea. Precise monitoring of 11 organic wastes biogas facilities were conducted. The organic decomposition rate of organic wastewater was 68.2 % for food wastes, 66.8 % for animal manure and 46.2 % for sewage sludge and 58.8 % for total organic wastes. As a result of analyzing the biogas characteristics before and after the pretreatment, the total average of the whole facility was measured to be 560 ppm using iron salts and desulfurization, and decreased to 40 ppm when the reduction efficiency was above 90 %. Particularly, when iron salt is injected into the digester, the treatment efficiency is about 93 %, and the average is reduced to 150 ppm. In the case of dehumidification, the absolute humidity and the relative humidity were analyzed. The dew point temperature of the facility where the dehumidification facility was well maintained as $14^{\circ}C$, the absolute humidity was $12.6g/m^3$, and the relative humidity was 35 %. Therefore, it is necessary to compensate for the disadvantages of biogasification facilities of organic waste resources and optimize utilization of biogas and improve operation of facilities. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure) through precision monitoring.