• 제목/요약/키워드: anaerobic biofilm reactor

검색결과 43건 처리시간 0.031초

생물학적 수소생산을 위한 Trickling Bed Biofilter에서의 친수성과 소수성 담체의 영향 (Effect of Hydrophilic- and Hydrophobic-Media on the Fermentative Hydrogen Production in Trickling Bed Biofilter)

  • 전병승;이선미;김용환;채희정;상병인
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.465-469
    • /
    • 2006
  • Two mesophilic trickling bed bioreactors filled with two different types of media, hydrophilic- and hydrophobic-cubes, were designed and tested for hydrogen production via anaerobic fermentation of sucrose. Each reactor consisted of a column packed with polymeric cubes and inoculated with heat-treated sludge obtained from anaerobic digestion tank. A defined medium containing sucrose was fed with changing flow rate into the capped reactor, hydraulic retention time and recycle rate. Hydrogen concentrations in gas-phase were constant, averaging 40% for all conditions tested. Hydrogen production rates increased up to $10.5 L{\cdot};h^{-1}{\cdot}L^{-1}$ of reactor when influent sucrose concentrations and recycle rates were varied. Hydrophobic media provided higher value of hydrogen production rate than hydrophilic media at the same operation conditions. No methane was detected when the reactor was under a normal operation. The major fermentation by-products in the liquid effluent of the both trickling biofilters were acetate and butyrate. The reactor filled with hydrophilic media became clogged with biomass and bio gas, requiring manual cleaning of the system, while no clogging occurred in the reactor with hydrophobic media. In order to make long-term operation of the reactor filled with hydrophilic media feasible, biofilm accumulation inside the media in the reactor with hydrophilic media and biogas produced from the reactor will need to be controlled through some process such as periodical backwashing or gas-purging. These tests using trickling bed biofilter with hydrophobic media demonstrate the feasibility of the process to produce hydrogen gas in a trickle-bed type of reactor. A likely application of this reactor technology could be hydrogen gas recovery from pre-treatment of high carbohydrate-containing wastewaters.

  • PDF

Influence of Electric Potential on Structure and Function of Biofilm in Wastewater Treatment Reactor : Bacterial Oxidation of Organic Carbons Coupled to Bacterial Denitrification

  • NA BYUNG KWAN;SANG BYUNG IN;PARK DAE WON;PARK DOO HYUN
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권6호
    • /
    • pp.1221-1228
    • /
    • 2005
  • Carbon electrode was applied to a wastewater treatment system as biofilm media. The spatial distribution of heterotrophic bacteria in aerobic wastewater biofilm grown on carbon electrode was investigated by scanning electron microscopy, atomic force microscopy, and biomass measurement. Five volts of electric oxidation and reduction potential were charged to the carbon anode and cathode of the bioelectrochemical system, respectively, but were not charged to electrodes of a conventional system. To correlate the biofilm architecture of bacterial populations with their activity, the bacterial treatment efficiency of organic carbons was measured in the bioelectrochemical system and compared with that in the conventional system. In the SEM image, the biofilm on the anodic medium of the bioelectrochemical system looked intact and active; however, that on the carbon medium of the conventional system appeared to be shrinking or damaging. In the AFM image, the thickness of biofilm formed on the carbon medium was about two times of those on the anodic medium. The bacterial treatment efficiency of organic carbons in the bioelectrochemical system was about 1.5 times higher than that in the conventional system. Some denitrifying bacteria can metabolically oxidize $H_{2}$, coupled to reduction of $NO_{3}^{-}\;to\;N_{2}$. $H_{2}$ was produced from the cathode in the bioelectrochemical system by electrolysis of water but was not so in the conventional system. The denitrification efficiency was less than $22\%$ in the conventional system and more than $77\%$ in the bioelectrochemical system. From these results, we found that the electrochemical coupling reactions between aerobic and anaerobic reactors may be a useful tool for improvement of wastewater treatment and denitrification efficiency, without special manipulations such as bacterial growth condition control, C/N ratio (the ratio of carbon to nitrogen) control, MLSS returning, or biofilm refreshing.

혐기성 유동층 반응기에서 층팽창에 따른 처리특성 및 미생물 부착특성 (A Study on the Characteristics of the Treatment with Bed Expansion and the Biomass Attachment in the Start-up of the AFBR)

  • 안재동;정종식;장인용
    • 한국환경보건학회지
    • /
    • 제21권2호
    • /
    • pp.20-26
    • /
    • 1995
  • The objective of this study is to estimate the effect of the bed expansion and the characteristics of attached biomass in the start-up in the anaerobic fluidized bed reactor(AFBR). The fluidized bed reactor was operated with bacteria supported on the bed of granular activated carbon(GAC). The reactor was operated at 35$\circ$C, 5 kg $COD/m^3\cdot day$ at bed expansion varying from 0 to 100% with soluble glucose wastewater(5,000 mg/l). When the effluent reached a steady state at 100% of bed expansion, maximum COD removal efficiency of 87.3% and 0.031 $m^3CH_4/kg COD_{removed}$ were obtained. At higher bed expansion, COD removal efficiency, methane production rate and biogas production rate increased. Especially, at 50% of bed expansion, the efficiency of the treatment increasedg rapidly in the AFBR. The biomass colonized in the pits and crevices of the GAC particle and no complete biofilm was established in the bioreactor during the experiment.

  • PDF

생물막 반응기에서 아질산성 질소의 축척에 미치는 영향인자 (Parameters Affecting Nitrite Accumulation in Submerged Biofilm Reactor)

  • 황병호;황경엽;최의소
    • 대한환경공학회지
    • /
    • 제22권10호
    • /
    • pp.1789-1797
    • /
    • 2000
  • 질산화에 요구되는 산소량과 탈질소화에 요구되는 탄소원의 양을 감소시킬 수 있는 암모니아성 질소의 아질산성 질소로의 부분적 질산화 반응을 유도하기 위해 생물막 반응기를 이용하여 고농도 암모니아성 질소를 함유하고 있는 혐기성 소화슬러지 탈수여액을 대상으로 알칼리도/암모니아성 질소의 농도비, pH, FA(free ammonia), 온도변화에 따른 아질산성 질소의 축적현상에 대한 연구를 수행하였다. 실험결과 유입수의 알칼리도/암모니아성 질소의 농도비를 증가시킴에 따라 유출수의 아질산성 질소의 축적도 증가하였으며, 이는 알칼리도의 농도가 증가함에 따라 반응기내의 pH가 높게 유지됨으로서 FA의 농도가 증가하게 되어 Nitrobacter의 성장을 선택적으로 저해시키기 때문인 것으로 판단된다. 일정한 알칼리도/암모니아성 질소의 농도비 조건에서 온도가 증가할수록 아질산성 질소의 축적도 증가하였다.

  • PDF

유동상 생물막법을 적용한 BNR공법에서의 인제거 영향인자 (Factors affecting Phosphorus removal in BNR process applied Moving Bed Biofilm)

  • 박운지;김동욱;이찬기
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.3-10
    • /
    • 2006
  • In this study, the of MBBR(moving bed biofilm reactor) process for Phosphorus Removal efficiency depending on seasons and the factors affecting phosphorus removal efficiency in the process is evaluated. As a result of experiment, T-P removal efficiency has its highest value in winter, (80.8%). and T-P removal efficiency has its lowest value in autumn, (49%). Optimum SRT for Phosphorus Removal revealed is about 8.8 days and process performs more efficiently as the temperature decreases. It is accepted that nitrate to anaerobic zone is affecting the Phosphorus removal process. With increasing the organic loading rate, Phosphorus removal efficiency also increases. Also, an experiment has been conducted to find out the highest efficiency according to Media existence and it has revealed that Media addition provides better phosphate removal.

  • PDF

연속흐름반응조에서 바이오필름형태의 탈염소화 미생물에 의한 TCE분해 모니터링 (Monitoring Anaerobic Reductive Dechlorination of TCE by Biofilm-Type Culture in Continuous-Flow System)

  • 박선화;한경진;홍의전;안홍일;김남희;김현구;김태승;김영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권5호
    • /
    • pp.49-55
    • /
    • 2012
  • A 1.28 L-batch reactor and continuous-flow stirred tank reactor (CFSTR) fed with formate and trichloroethene (TCE) were operated for 120 days and 56 days, respectively, to study the effect of formate as electron donor on anaerobic reductive dechlorination (ARD) of TCE to cis-1,2-dichloroethylene (c-DCE), vinyl chloride (VC), and ethylene (ETH). In batch reactor, injected 60 ${\mu}mol$ TCE was completely degraded in the presence of 20% hydrogen gas ($H_2$) in less than 8 days by anaerobic dechlorination mixed-culture (300 mg-soluble protein), Evanite Culture with ability to completely degrade tetrachloroethene (PCE) and -TCE to ETH under anaerobic conditions. Once the formate was used as electron donor instead of hydrogen gas in batch or chemostat system, the TCE-dechlorination rate decreased and acetate production rate increased. It indicates that the concentration of hydrogen produced in both systems is possibly more close to threshold for homoacetogenesis process. Soluble protein concentration of Evanite culture during the batch test increased from 300 mg to 688 mg for 120 days. Through the protein monitoring, we confirmed an increase of microbial population during the reactor operation. In CFSTR test, TCE was fed continuously at 9.9 ppm (75.38 ${\mu}mol/L$) and the influent formate feed concentration increased stepwise from 1.3 mmol/L to 14.3 mmol/L. Injected TCE was accumulated at 18 days of HRT, but TCE was completely degraded at 36 days of HRT without accumulation of the injected-TCE during the left of experiment period, getting $H_2$ from fermentative hydrogen production of injected formate. Although c-DCE was also accumulated for 23 days after beginning of CFSTR operation, it reached steady-state in the presence of excessive formate. We also evaluated microbial dynamic of the culture at different chemical state in the reactor by DGGE (denaturing gradient gel electrophoresis).

생물막 반응키에서의 폐수 처리 및 Fluorescence In Situ Hybridization에 의한 복합 미생물계 구조 해석 (Wastewater Treatment and Microbial Structure Analysis by Fluorescence In Situ Hydridizationin a Biofilm Reactor)

  • 김동진;한동우;이수철;박병곤;권일;성창근;박완철
    • KSBB Journal
    • /
    • 제17권1호
    • /
    • pp.80-87
    • /
    • 2002
  • 유기물 제거뿐만 아니라 안정적으로 질소와 인의 동시 제거를 위한 순환식 생물막 반응기를 제작, 운전하여 최적의 운전 인자를 도출하고, 질소 제거의 텃 번째 단계인 질산화 및 뒤이은 탈질에 관여하는 미생물들의 군집 구조 분석을 수행하였다. 유기물 제거와 질소와 인의 동시 제거를 위한 순환식 생물막 반응기는 143일 동안 운전되었다. 이 결과 $COD_{cr},\;BOD_5$, SS의 경우 각각 88, 88, 97%의 평균 제거효율을 보였다 이 기간 중 질산화율은 약 96% 정도로 유입 ${{NH_4}^{+}}_{-}N$의 대부분이 제거됨을 보였다. 하지만 탈질율은 평균 45% 정도로 나타났다. 반응기로 유입되는 총 인의 경우 약 44%가 제거되었다. 질소제거의 첫 번째 단계인 질산화가 일어나는 호기성 반응조 내 질산화 미생물의 경우 FISH 관찰 결과, 주요 암모니아 산화균 및 아질산 산화균으로는 Nitrosomonas spp.와 Nitrospira sap.가 관찰되었다. 또한 탈질 반응이 일어나는 준혐기성 반응조에서는 Rhodobacter, Rhodovulum, Roseebacter 그리고 Paracoccus 속에 속하는 탈질 미생물들이 전체 미생물의 약 10~20% 정도를 차지하며 분포하였다.

입상미생물을 이용한 고농도 유기성폐수의 혐기성처리 (Anaerobic Treatment of High Strength Organic Wastewater by Granulated Microorganism)

  • 임재명;한동준;전태성;이현주
    • 산업기술연구
    • /
    • 제16권
    • /
    • pp.61-70
    • /
    • 1996
  • This research aims to find granulation and organic removal of the piggery wastewater with the upflow blanket filter(UBF) reactor. UASB process had the effect of high pH on the granulation phase. But teh effect was decreased after the granule formation. The filter zone of the UBF reactor had the function of GSS and contributed to removing the organic because of its biofilm formation. The removal rates of total COD and soluble COD were 70% ~ 80% and 60 ~ 80% at an influent organic loading range of $2{\sim}17.4kgCOD/m^3{\cdot}d$, respectively. The methane production rate with the organic removal was $0.21{\sim}0.34{\ell}CH_4/gCOD_{rem}$ and the maximum methan production rate was $0.34CH_4{\ell}/gCOD_{rem}$ at the volumetric loading $5kgCOD/m^3{\cdot}d$.

  • PDF

Low Temperature Effects on the Nitrification in a Nitrogen Removal Fixed Biofilm Process Packed with SAC Media

  • Jang, Se-Yong;Byun, Im-Gyu
    • 한국환경과학회지
    • /
    • 제22권1호
    • /
    • pp.1-6
    • /
    • 2013
  • A fixed biofilm reactor system composed of anaerobic, anoxic(1), anoxic(2), aerobic(1) and aerobic(2) reactor was packed with synthetic activated ceramic (SAC) media and adopted to reduce the inhibition effect of low temperature on nitrification activities. The changes of nitrification activity at different wastewater temperature were investigated through the evaluation of temperature coefficient, volatile attached solid (VAS), specific nitrification rate and alkalinity consumption. Operating temperature was varied from 20 to $5^{\circ}C$. In this biofilm system, the specific nitrification rates of $15^{\circ}C$, $10^{\circ}C$ and $5^{\circ}C$ were 0.972, 0.859 and 0.613 when the specific nitrification rate of $20^{\circ}C$ was assumed to 1.00. Moreover the nitrification activity was also observed at $5^{\circ}C$ which is lower temperature than the critical temperature condition for the microorganism of activated sludge system. The specific amount of volatile attached solid (VAS) on media was maintained the range of 13.6-12.5 mg VAS/g media at $20{\sim}10^{\circ}C$. As the temperature was downed to $5^{\circ}C$, VAS was rapidly decreased to 10.9 mg VAS/g media and effluent suspended solids was increased from 3.2 mg/L to 12.0 mg/L due to the detachment of microorganism from SAC media. And alkalinity consumption was lower than theoretical value with 5.23 mg as $CaCO_3$/mg ${NH_4}^+$-N removal at $20^{\circ}C$. Temperature coefficient (${\Theta}$) of nitrification rate ($20^{\circ}C{\sim}5^{\circ}C$) was 1.033. Therefore, this fixed film nitrogen removal process showed superior stability for low temperature condition than conventional suspended growth process.

Dechlorination of High Concentrations of Tetrachloroethylene Using a Fixed-bed Reactor

  • Chang, Young-C.;Park, Chan-Koo;Jung, Kweon;Kikuchi, Shintaro
    • 한국환경보건학회지
    • /
    • 제36권4호
    • /
    • pp.323-336
    • /
    • 2010
  • We evaluated the properties of a fixed-bed column reactor for high-concentration tetrachloroethylene (PCE) removal. The anaerobic bacterium Clostridium bifermentans DPH-1 was able to dechlorinate PCE to cis-1,2-dichloroethylene (cDCE) via trichloroethylene (TCE) at high rates in the monoculture biofilm of an upflow fixed-bed column reactor. The first-order reaction rate of C. bifermentans DPH-1 was relatively high at $0.006\;mg\;protein^{-1}{\cdot}l{\cdot}h^{-1}$, and comparable to rates obtained by others. When we gradually raised the influent PCE concentration from $30\;{\mu}M$ to $905\;{\mu}M$, the degree of PCE dechlorination rose to over 99% during the operation period of 2,000 h. In order to maintain efficiency of transformation of PCE in this reactor system, more than 6 h hydraulic retention time (HRT) is required. The maximum volumetric dechlorination rate of PCE was determined to be $1,100\;{\mu}mol{\cdot}d^{-1}l$ of reactor $volume^{-1}$, which is relatively high compared to rates reported previously. The results of this study indicate that the PCE removal performance of this fixed-bed reactor immobilized mono-culture is comparable to that of a fixed-bed reactor mixture culture system. Furthermore, our system has the major advantage of a rapid (5 days) start-up time for the reactor. The flow characteristics of this reactor are intermediate between those of the plug-flow and complete-mix systems. Biotransformation of PCE into innocuous compounds is desirable; however, unfortunately cDCE, which is itself toxic, was the main product of PCE dechlorination in this reactor system. In order to establish a system for complete detoxification of PCE, co-immobilization of C. bifermentans DPH-1 with other bacteria that degrade cDCE aerobically or anaerobically to ethene or ethane may be effective.