• Title/Summary/Keyword: amplitude method

Search Result 2,237, Processing Time 0.03 seconds

MOTION IN A HANGING CABLE WITH VARIOUS DIFFERENT PERIODIC FORCING

  • Oh, Hyeyoung
    • The Pure and Applied Mathematics
    • /
    • v.21 no.4
    • /
    • pp.281-293
    • /
    • 2014
  • We investigate long-term motions of the cable when cable has different types of periodic forcing term. Various different types of solutions are presented by using the 2nd order Runge-Kutta method under various initial conditions. There appeared to be small- and large-amplitude solutions which have different nodal structure.

Digital Control of Single Phase Buck-Boost Converter by Pulse Amplitude Modulation Mehtod (PAM방식을 적용한 단상 승강압형 정류기의 디지탈제어)

  • 김태진;변영복;조기연;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.54-57
    • /
    • 1998
  • This paper describes a digital implementation of a pulse amplitude modulation(PAM) method for a unity-power-factor buck-booster converter. A digital controller is designed and implemented by a Digital Signal Processor(DSP) to replace the analog control circuit for PAM. Experimental results are presented and compared with simulations.

  • PDF

Time-domain hybrid method for simulating large amplitude motions of ships advancing in waves

  • Liu, Shukui;Papanikolaou, Apostolos D.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.3 no.1
    • /
    • pp.72-79
    • /
    • 2011
  • Typical results obtained by a newly developed, nonlinear time domain hybrid method for simulating large amplitude motions of ships advancing with constant forward speed in waves are presented. The method is hybrid in the way of combining a time-domain transient Green function method and a Rankine source method. The present approach employs a simple double integration algorithm with respect to time to simulate the free-surface boundary condition. During the simulation, the diffraction and radiation forces are computed by pressure integration over the mean wetted surface, whereas the incident wave and hydrostatic restoring forces/moments are calculated on the instantaneously wetted surface of the hull. Typical numerical results of application of the method to the seakeeping performance of a standard containership, namely the ITTC S175, are herein presented. Comparisons have been made between the results from the present method, the frequency domain 3D panel method (NEWDRIFT) of NTUA-SDL and available experimental data and good agreement has been observed for all studied cases between the results of the present method and comparable other data.

Effects of anesthesia on echocardiograms in myocardial infarcted dogs (심근경색 유발견에서 마취가 심초음파에 미치는 영향)

  • Yoon, Jung-hee;Sung, Jai-ki
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.3
    • /
    • pp.669-685
    • /
    • 1997
  • The present study was performed to evaluate the effects of xylazine and tiletamine + zolazepam on echocardiograms before and after experimental myocardial infarctions in clinically normal dogs taken preliminary examinations related to cardiac function. The results are as follows. With xylazine administration, left ventricle end-diastolic dimension, left ventricle end-systolic dimension, left atrium/aorta, ejection time and velocity of circumferential fiber shortening increased and mitral valve CD slope, % delta D decreased(p<0.01). In tiletamine+zolazepam administered group, interventricular septum amplitude(p<0.01), mitral valve DE slope(p<0.05) and ejection time(p<0.01) decreased and left atrium/aorta, ejection time also decreased compared with xylazine group(p<0.01). In 48 hours after experimental myocardial infarction group, anterior aortic wall amplitude decreased compared with control, xylazine, tiletamine + zolazepam group, respectively(p<0.01). Posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end systolic dimension increased compared with control and tiletamine + zolazepam group, respectively(p<0.01). Left ventricular posterior wall end systolic dimension decreased compared with control(p<0.01). Left ventricular posterior wall amplitude decreased compared with control and tiletamine+zolazepam group(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % thickening left ventricular posterior wall decreased compared with control(p<0.05). % delta D decreased compared with control and tiletamine+zolazepam group(p<0.01). Ejection time decreased compared with xylazine(p<0.01). Velocity of circumferential fiber shortening increased compared with control and tiletamine + zolazepam group(p<0.01). With xylazine administration 48 hours after experimental myocardial infarction, anterior aortic wall amplitude, posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end-diastolic dimension increased compared with control(p<0.01). Left ventricle end-systolic dimension increased compared with control and tiletamine + zolazepam group, respectively(p<0.01). Left ventricular posterior wall end-systolic dimension and left ventricular posterior wall end-diastolic dimension decreased compared with control(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % thickening left ventricular posterior. wall(p<0.05) and % delta D(p<0.01) decreased compared with control. Velocity of circumferential fiber shortening increased compared with tiletamine + zolazepam group(p<0.01). With tiletamine + zolazepam administration 48 hours after experimental myocardial infarction, anterior aortic wall amplitude decreased compared with control, xylazine and tiletamine+zolazepam group, respectively(p<0.01). Posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end-systolic dimension increased compared with control and tiletamine+zolazepam group(p<0.01). Left ventricular posterior wall end-systolic dimension, left ventricular posterior wall end-diastolic dimension and interventricular septum amplitude decreased compared with control(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % delta D decreased compared with control and tiletamine + zolazepam group(p<0.01). Ejection time decreased compared with xylazine group and velocity of circumferential fiber shortening increased compared withtiletamine+zolazepam group(p<0.01). Conclusively, echocardiography was proved to be a useful, diagnostic, non-invasive and simple method for establishing the diagnosis of myocardial infarction and evaluating the effects of drug on cardiac function before and after myocardial infarction.

  • PDF

Construction of High-Precision Ultrasonics Distance Amplitude Characteristics Curve for Integrity Evaluation of Rail Weld Zone (레일용접부의 건전성평가를 위한 고정밀 초음파 거리진폭특성곡선의 구축)

  • 윤인식
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.8-13
    • /
    • 2003
  • This study proposes integrity evaluation method of weld zone in rails using high precision distance amplitude characteristics curve(DACC) and ultrasonic signals. For these purposes, the ultrasonic signals for defects(porosity and crack) of weld zone in rails are acquired in the type of time series data and echo strength. 6 lines in the DACC indicated damage evaluation standard of weld zone in rails. The aquired ultrasonic signals agree fairly well with the mesured results of reference block and sensitivity block(defect location, beam propagation distance, echo strength, etc). The proposed high precision DACC in this study can be used for integrity evaluation of weld zone in rails.

Large Amplitude Nonlinear Vibration of Rectangular Plates with Simply Support and Fixed Edges (단순지지 및 고정된 직사각형평판의 비선형변동)

  • ;;Kim, Beam Soo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.1 no.3
    • /
    • pp.141-145
    • /
    • 1977
  • In this paper, approximate solutions of the von Karman equations for the free flexural vibration of a transversely isotropic thin rectangular plate with two simply supported edges and two clamped edges are obtained. Applying one term Ritz-Galerkin procedure, the spatial dependent part of the equation is separated and time dependent function is found to be the Duffing's equation. Then the relation between nonlinear period and amplitude of the vibration is obtained by using averaging method which is a method of the perturbation procedure. It can be seen that averaging method is easy and agrees well with prior results.

A Study on the Ultrnsonic Distance Amplitude Characteristics Curve for Weld Defects Evaluation of Titanium Weld Zone (티타늄 용접부의 용접결함평가를 위한 초음파거리진폭특성곡선에 관한 연구)

  • Yi, Won;Park, Hee-Dong;Yun, In-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.7-12
    • /
    • 2008
  • This study proposes integrity evaluation method of weld zone in titanium using titanium distance amplitude characteristics curve(TDACC) and ultrasonic signals. For these purposes, the ultrasonic signals for porosity defects of weld zone in titanium are acquired in the type of time series data and echo strength. 4 lines in the DACC indicated damage evaluation standard of weld zone in titanium. The acquired ultrasonic signals agree fairly well with the measured results of reference block and sensitivity block(defect location, bean1 propagation distance, echo strength, etc). The proposed TDACC in this study agree fairy well with the measured results of weld zone in titanium(weld defects as porosity). The proposed TDACC in this study can be used for integrity evaluation of weld zone in titanium.

The Analysis of Power Line Galloping by Describing Function Method (Describing Function Method를 이용한 송전선의 전선도약(Galloping)현상 해석에 관한 연구)

  • 노창주;박한석;변기식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.4
    • /
    • pp.339-345
    • /
    • 1992
  • Estimates of maximum amplitudes of conductor galloping are needed in order to determine appropriate phase-to-phase clearances on the overhead lines. One approach to obtaining these estimates is through the use of mathematical models of conductor galloping. Unfortunately, the models that consider both vertical conductor motion (Den Hartog type) and torsional conductor motion are often too complex for practical use. However, the estimates of maximum amplitude obtained from galloping models that assume only vertical (Den Hartog type) conductor motion tend to be too conservative. This paper presents the DF method to obtain the estimates of the amplitude and the frequency of galloping limit cycle, along with the wind pressure at which they occur, from a nonlinear dynamic model that considers both Den Hartog type and torsional conductor motion. From these results, the useful data for the line design guide and further insight into the mechanism of the conductor galloping are obtained.

  • PDF

Large Amplitude Heave and Roll Simulations by the Chimera RANS Method

  • Kang, Chang-Ho
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • An oscillating body motion with extremely large amplitude has been studied using the viscous flow solver. Time simulations of oscillating ship hull in prescribed heave and roll motions are presented using RANS method with FAM approach (Chen, 1995). For viscous flows, laminar flow and turbulent flow with $textsc{k}$-$\varepsilon$ model are considered and compared. The viscous flow solver of RANS method is performed together with a Chimera type of multi-block grid system to demonstrate the advantage of accurate and efficient zonal approach. In the present study, effects of viscosity and oscillation degree are discussed using Re=1000 and Re=1000000. Large motion of oscillating body shows clear vortex propagation that is not possible for inviscid flow to present.

  • PDF

Combination resonances of imperfect SSFG cylindrical shells rested on viscoelastic foundations

  • Foroutan, Kamran;Ahmadi, Habib
    • Structural Engineering and Mechanics
    • /
    • v.75 no.1
    • /
    • pp.87-100
    • /
    • 2020
  • The present paper investigates the combination resonance behavior of imperfect spiral stiffened functionally graded (SSFG) cylindrical shells with internal and external functionally graded stiffeners under two-term large amplitude excitations. The structure is embedded within a generalized nonlinear viscoelastic foundation, which is composed of a two-parameter Winkler-Pasternak foundation augmented by a Kelvin-Voigt viscoelastic model with a nonlinear cubic stiffness, to account for the vibration hardening/softening phenomena and damping considerations. With regard to classical plate theory of shells, von-Kármán equation and Hook law, the relations of stress-strain are derived for shell and stiffeners. The spiral stiffeners of the cylindrical shell are modeled according to the smeared stiffener technique. According to the Galerkin method, the discretized motion equation is obtained. The combination resonance is obtained by using the multiple scales method. Finally, the influences of the stiffeners angles, foundation type, the nonlinear elastic foundation coefficients, material distribution, and excitation amplitude on the system resonances are investigated comprehensively.