• Title/Summary/Keyword: amount of water

Search Result 7,107, Processing Time 0.045 seconds

Water Quality Management using WASPS & WASP Builder for a Basin of an Agricultural Reservoir (WASP5 & WASP Builder을 이용한 농업용저수지 유역의 수질관리)

  • Chung, Paul-Gene;Goh, Hong-Seok;Hyun, Mi-Hee;Lee, Eun-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.422-431
    • /
    • 2004
  • Water quality modeling was performed for the purpose of diagnosis and prediction of water quality in Gyoung Choen reservoir, using EUTR05/WASP Build model. WASP Builder is capable of visual display in window and it has an advantage of updating and modification for data. Field data of 1992, Spring, Summer, and Fall, were used to calibrate model and these results were validated using data of 2000, Spring, Summer, and Fall. The reservoir was divided into 4 epilimnion segments. Water quality system for modeling were consist of BOD, Chlorophyll-a, DO, $NH_3-N$, $NO_3-N$, T-N, $PO_4-P$, T-P. The results of water quality modelling using EUTR05/WASP Builder, a range of the Correlation for calibration of BOD, T-N, T-P, and Chlorophyll-a according to three seasons are 0.63~0.90, 0.81~0.97, 0.75~0.98, and 0.77~0.98 respectively. And the correlation between simulated and observed values for verification of BOD, T-N, T-P, and Chlorophyll-a according to three seasons are 0.93, 0.94, 0.81, and 0.80 respectively. Among the pollutant sources for a basin of the Gyoung Choen reservoir, generated amount of livestock is the highest and BOD, T-N, T-P of generated loading percentage are 94%, 81%, and 95%. So, we suppose that inflow load amount will decrease 50% and increase 50% only livestock about current load amount. If increasing load amount of livestock 50% in segment 2 and 3, BOD, T-N, and T-P simulated increasing to range of $0.02~0.15mg/{\ell}$, $0.029~0.08mg/{\ell}$, $0.011~0.029mg/{\ell}$ in comparison with current water quality

The Effect of Chemical Admixtures on Removal of Scattered Dust

  • Son, Ho Jeong;An, Jung Min;Chung, Chul-Woo;Lee, Jae-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.594-601
    • /
    • 2013
  • One of the important problems associated with building demolition is the dust generated during the work. The only way to reduce the demolition dust is to use a dust net during water spraying. However, it is difficult to supply the necessary amount of water to remove demolition dust, thus making it difficult to apply this method on a demolition site. This work attempted to find an alternative approach to dust removal by incorporating surfactant and high range AE water reducer in the water being sprayed. Through the experiment, it was found that the addition of surfactant did not contribute to the removal of demolition dust. However, the use of high range AE water reducer showed better performance than spraying plain water, indicating that some amount of demolition dust had been adsorbed on the high range AE water reducer.

A Study on the Water Supplies and Sewage Amount in the Apartment Complexes (아파트단지의 급수량 및 오수발생량에 대한 조사 연구)

  • Yun, Yeo-Jin;Choe, Myeong-Su;Bang, Gi-Ung
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.155-165
    • /
    • 1998
  • As an improvement on qualities of lives and a change in the habitual ways people eat require more water to be used for daily lives, the amount of wastewater generated from our usual lives is also expected to be in higher rate of consumption. The unit loading factor of sewage flow-rate based upon the number of people living in the apartment complexes has to be found for the design of the sewage or wastewater treatment facilities. These data are definitely thought to be useful for the plans to operate the sewage treatment facilities and for those to establish the plans toward a management of water qualities. Thus this study has shown that the data regarding the water supplies and the number of apartment residents within the 123 districts of KNHC(Korea National Housing Corporation) were collected and analyzed. One district in Seoul and the other local district were chosen an the experimental sites for th hourly, daily, weekly and seasonal measurements of the influent sewage flow-rate. The unit loading factor of influent sewage flow-rate were determined through the comparison of total sewage amount in combination with the number of people residing in two apartment complexes with supplying amount of water.

  • PDF

Mutagenic Activity of Organic Pollutans in Drinking Water in Seoul (수도권 상수중 유기오염물질의 돌연변이원성)

  • Shin, Dong-Chun;Jang, Jae-Yeon;Jo, Seong-Joon;Chung, Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.284-294
    • /
    • 1988
  • To measure the mutagenic activity of micro-organic pollutants in drinking water, mutagenicity test was conducted using Salmnella typhimurium TA 98 strain on the water sample taken from three water supply stations and six tap water in Seoul in July and November 1987. The results were as follows : 1. The average amounts of organic matters in raw, treated, and tap water sampled in July were 0.38mg/l, 0.28mg/l, and 0.45mg/l. respectively, and sampled in November were 0.34mg/l, 0.24mg/l, and 0.22mg/l, respectively. The amount of organic matters of tap water sampled in November did not increase while that of tap water sampled in July increased compare to those of raw or treated water. 2. The amount of organic matters is the highest in neutral fraction compare to acidic and basic fractions. 3. In the five out of six tap water and raw water of Paldang and Kuui station sampled in July, the mutagenicity ratios were greater then two (both direct and indirect mutagenicity). 4. In the three out of six tap water and raw and treated water of Kuui station sampled in November, the mutagenicity ratios were greater than two. 5. While mutagenic activities were low in acidic and basic fraction, they were high in neutral fraction. The samples which had high mutagenic acitivity in the total amount also showed high mutagenic activity in neutral fraction. 6. While mutagenic acitivity was decreased after the treatement of water, it was increased in tap water as the distance from the water supply station increases.

  • PDF

Effect of Water Induction on the Performance and Exhaust Emissions in a Diesel Engine (II)

  • Ryu, Kyunghyun;Oh, Youngtaig
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1640-1647
    • /
    • 2004
  • This study was to investigate the effects of water induction through the air intake system on the characteristics of combustion and exhaust emissions in an IDI diesel engine. The fuel injection timing was also controlled to investigate a method for the simultaneous reduction of smoke and NOx when water was injected into the combustion chamber. The formation of NOx was significantly suppressed by decreasing the gas peak temperature during the initial combustion process because the water played a role as a heat sink during evaporating in the combustion chamber, while the smoke was slightly increased with increased water amount. Also, NOx emission was significantly decreased with increase in water amount. A simultaneous reduction in smoke and NOx emissions was obtained when water was injected into the combustion chamber by retarding more 2$^{\circ}C$A of the fuel injection timing than without water injection.

A Study on the Simultanious Reduction of Smoke and NOx by Water Injection through Intake Port in Diesel Engine (디젤기관에서 흡기관내로의 물 분사에 의한 매연과 NOx의 동시 저감에 관한 연구)

  • Ryu, Kyung-Hyun;Oh, Young-Taig
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2186-2191
    • /
    • 2003
  • This study is to investigate the effects of water induction through the air intake system on the characteristics of combustion and exhaust emissions in diesel engine. The effects of water induction through the air intake port were considered in IDI diesel engine in this study. The formation of NOx was significantly suppressed by decreasing the gas peak temperature during the initial combustion process because the water play a role as a heat sink during evaporating in the combustion chamber, but the smoke was slightly increased with increased water amount. Also, NOx significantly decreased with increase in water amount. A simultaneous reduction in smoke and NOx emissions can be obtained when water is injected into the combustion chamber by retarding the fuel injection timing more than without water injection.

  • PDF

Method of estimating exploitable groundwater amount considering relationship between precipitation and recharge and the variation of 10-year minimum precipitation (강수량-함양량 관계와 10년 최소강수량 변화를 고려한 지하수 개발가능량 산정 기법)

  • Chung, Il-Moon;Lee, Jeongwoo;Lee, Jeong Eun;Kim, Min Soo
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.6
    • /
    • pp.421-427
    • /
    • 2019
  • The amount of exploitable groundwater amount in Korea has been determined by multiplying the 10-year frequency low precipitation by the recharge rate. In practice, however, the interpretation of the frequency analysis of precipitation is omitted, and the value obtained by multiplying the average recharge rate by the minimum precipitation in the recent 10 years is used as the recharge amount. Therefore, the contradiction arises that the amount of precipitation to be applied is determined according to the period selection rather than the actual low precipitation by the 10-year frequency analysis. In this study, we proposed a method for estimating the exploitable groundwater amount using the recharge amount considering the moving averaged 10-year minimum precipitation and the size of precipitation. This method was applied to the Uiwang, Gwacheon and Seongnam areas and the exploitable groundwater amount was calculated and compared with the results obtained by conventional methods. As a result, it has been confirmed that if the 10-year minimum precipitation is selected in the period including the extreme drought, the problem of underestimating the exploitable groundwater amount can be overcome by using the moving average minimum precipitation.

A System Dynamics Model to Analyze the Effects of Investments for Improvement of Environmental Conditions in Nak-Dong River Basin (낙동강 유역 환경개선 투자 효과 분석을 위한 시스템다이내믹스 모델)

  • Park, Suwan;Kim, Kimin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.561-569
    • /
    • 2016
  • In this paper a concept of the paradigm shift in the operations of Water and Wastewater systems regarding the production and usage of water was introduced. Based on this concept the interrelationships between the water quality in the upper basin of NakDong River relative to Busan and the degree of satisfaction of the customers on the water supply service in Busan were modeled using the System Dynamics modeling methodology. SamRangJin basin area was determined as the upper basin of Busan after analyzing the relationships between the water quality of MoolGeum water intake point and water quality data of various mid- and upper water intake points along NakDong River. The amount of contaminants generated in SamRangJin basin was modeled using the Gross Regional Domestic Product in the area and the treated amount was calculated using the efficiency of wastewater treatment and the degree of improvement of environmental condition per investment. The water quality at MoolGeum water intake point was modeled to take the effects of the remaining amount of contaminants after treatment and the non-point source contaminants in SamRangJin basin. Using the developed System Dynamics model the effects of the investment for the improvement of environmental condition in SamRangJin basin were compared to the case of alternate water source development for Busan in terms of the degree of satisfaction of the customers on the water supply service in Busan.

Varietal Difference in Water Absorption Characteristics of Milled Rice, and Its Relation to the Other Grain Quality Components

  • Hae Chune, Choi;Jeong Hyun, Chi;Soo Yeon, Cho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.44 no.3
    • /
    • pp.288-295
    • /
    • 1999
  • Nineteen japonica and Tongil-type rices were selected from seventy nine Korean and Japanese rice cultivars grown in 1989 based on the water uptake behavior of milled rice under the room temperature and boiling conditions. The selected rice cultivars were investigated for water absorbability and some physicochemical characteristics of milled rice, proper water amount for cooking and sensory evaluation of cooked rice. The relationships among the tested grain properties were also examined. The highest varietal variation of water uptake rate was observed at twenty minutes after soaking in water. The maximum water uptake of milled rices at room temperature occurred mostly at about eighty minutes after soaking in water. Newly harvested rices showed a significantly lower water uptake rate of milled rice at 20 minutes after soaking, a relatively higher maximum water absorption ratio under the room temperature, and the less water uptake and volume expansion of boiled rice compared with the one-year old rice samples. The water uptake rate and the maximum water absorption ratio showed significantly negative correlations with the K/Mg ratio and alkali digestion value(ADV) of milled rice. The rice materials showing the higher amount of hot water absorption exhibited the larger volume expansion of cooked rice. The harder rices with lower moisture content revealed the higher rate of water uptake at twenty minutes after soaking and the higher ratio of maximum water uptake under the room temperature condition. These water uptake characteristics were not associated with the protein and amylose contents of milled rice ansd the palatability of cooked rice. The water/rice ratio(in w/w basis) for optimum cooking was averaged to 1.52 in dry milled rices (12% wet basis) with varietal range from 1.45 to 1.61 and the expansion ratio of milled rice after proper boiling was averaged to 2.63(in v/v basis). The water amount needed for optimum cooking was the lowest in Cheongcheongbyeo (Tongil-type rice) and the highest in Jinbubyeo, and the amount could be estimated with about 70% fittness by the multiple regression formula based on some water uptake characteristics, ADV and amylose content of milled rice as the independent variables. Nineteen rice cultivars were classified into seven groups based on scatter diagram projected by principal component analysis using eight properties related to water uptake and gelatinization of milled rice.

  • PDF

Treatment of Concrete Wastewater in Repair of Bridge Deck (교량 바닥판 보수공사에서 발생하는 콘크리트 폐수처리 방안)

  • Lee, Bong-Hak;Choi, Pan-Gil;Kim, Jung-Ki
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.125-132
    • /
    • 2008
  • As of 2003, construction waste has been produced at the level of 130,614.8 tons/day, in which the amount of waste concrete was 92,639.1 tons/day and accounted for about 66.4% of the amount of construction waste. Waste concrete is mainly produced in construction work and civil engineering work. Especially, road surface crushing method using a large amount of water requires thorough management of concrete wastewater. The aim of this study was to analyze water pollution due to concrete wastewater generated in repair of bridge deck using road surface crushing equipment and to suggest reasonable countermeasures for solve the problem. In this study, it was surveyed current conditions of produced concrete wastewater in bridge deck repair, analyzed physical features of concrete wastewater, expected effects of water pollution on inflow rivers if it is not treated, established treatment plan of water pollution by categories, and calculated capacity of each treatment process and required amount of necessary chemicals. As a result of sampling wastewater generated in field sites and testing it at a lab scale, it was revealed that the original wastewater was produced in removing concrete from bridge deck slabs using surface crushing equipment whose pH was 12.53, CODMn was 12.910mg/L, SS was 547.0mg/L, and other heavy metals were included in extremely small quantities.

  • PDF