• 제목/요약/키워드: amount of ventilation

검색결과 210건 처리시간 0.02초

전투기 후류처리용 엄체호 최적설계에 관한 연구 (A Study on Optimal Design of the Fighter Igloo Diffuser)

  • 윤용현
    • 한국항공운항학회지
    • /
    • 제18권4호
    • /
    • pp.86-91
    • /
    • 2010
  • New Design configurations of the fighter aircraft igloo diffuser were studied based on the closed ventilation type in contrast to the conventional open distribution type. To validate the enhanced and safe performance, the exhaust flow patterns of the two igloo diffuser types were simulated by both experimental and computational approaches as design tools. Flow visualizations were conducted to investigate the exhaust flow patterns in experimental approach. In addition, the commercial code called Fluent was used to calculate flow field properties. Computational simulations provided detailed parametric studies that significantly reduced the amount of experimentation necessary to alter the design parameters of the existing fighter igloo diffuser. The closed ventilation type of the igloo diffuser was shown the better results.

태안 시설원예단지의 온실 냉난방 부하 분석 (Analyses of Heating and Cooling load in Greenhouse of Protected Horticulture Complex in Taean)

  • 서원명;배용한;허해준;곽철순;이석건;이종원;윤용철
    • 한국농공학회논문집
    • /
    • 제51권6호
    • /
    • pp.45-52
    • /
    • 2009
  • This study was conducted in the process that the basic plan of the formation of the thermal energy complex in the Iwon reclaimed land of Taean was being made. Targeting for the large-sized greenhouse to be made in this area, it examined the cooling and heating load and the amount of ventilation, and also analyzed the economic efficiency of heating. The research results are as per the below: The minimum ambient temperature of this area was measured on January 7, 2001, which was $-18.7^{\circ}C$, and the maximum ambient temperature of this area was measured on July 24, 1994, which was $36.7^{\circ}C$. The maximum heating load was 39,011 MJ/h, but the date when the maximum heating load was not consistent with the date when the minimum temperature was measured. The maximum cooling load was 88,562MJ/h, It was approximately 2.3 times of the maximum heating load, which was measured at 14:00 hours on September 4, 2000. The maximum amount of ventilation heat was 138,639MJ/h. Assuming the rate of solar heat use as 10%, 20%, 50%, and 100%, the total sum of cost-benefit would be ₩-193,450,000, ₩-634,930,000, ₩-3,372,960,000, and ₩-9,850,420,000, respectively 20 years later. The break-even point of the geothermal heat pump would be about 4 years for 10% use, about 3 years for 20% or 50% use, and approximately 6 years for 100% use. It was found that 50% use would be most advantageous. In case two systems are combined, the break-even point will be 10 years, 8 years, and 11 years respectively.

터널형 하우스에서 환기방법이 참외의 생육 및 품질에 미치는 영향 (Effect of the Ventilation Method on the Growth and Quality of Melon (Cucumis melo L.) in Greenhouse of Tunnel Type)

  • 신용습;연일권;도한우;서동환;배수곤;최성국;최부술
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.187-193
    • /
    • 1996
  • 여름철 고온기 참외재배시 환기방법에 따른 시설내 온도차이가 참외의 생육 및 품질에 미치는 영향을 구명하고자 측면환기공 환기구(Type 1), 측면환기공 환가+천정 환기공 환기구(Type 2) 및 권취식 환기구(Type 3)로 구분하여 시험을 실시한 결과를 요약하면 다음과 같다. 1. 환기방법별 온도의 하강효과는 Type 3이 가장 좋았고 Type 2, Type 1의 순으로 나타났다. 2. 환기방법에 따른 온도분포는 측면환기공만 있는 Type 1과 천정환기통 및 측면환기공이 있는 Type 2의 경우 환기공 및 환기통의 면적이 적어 중력환기 및 풍력환기가 미세하여 온도가 상승하였다. Type 3은 측면환기 면적이 넓어 풍력환기에 의한 공기의 유입, 유출이 쉬워 온도분포가 비교적 균일하였다. 3. 실측치를 이용하여 내외기온차이에 의한 환기량을 추정한 결과, Type 3이 Type 1 및 Type 2보다도 많음을 알 수 있었다. 4. 생육 및 상품성을 조사한 결과, Type 3이 Type 2, Type 1보다도 엽수 및 엽면적이 증가하여 생육이 양호하였고 과중, 과육두께, 기형과율, 상품과율 등 상품성도 우수하였다. 5. 수확시기별 상품수량은 각처리 공히 수확초기 보다는 후기로 갈수록 증가하였다. 특히 Type 3에서 뚜렷한 경향을 보였다.

  • PDF

터널환기제어를 위한 차종별 오염물 배출량 추정 (Estimation of Pollutants Exhausted :From vehicles for Tunnel ventilation Control)

  • 홍대희;김우동;김태형;민원
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.110-115
    • /
    • 2002
  • The tunnels built in recent years are equipped with traffic counters and pollution sensors (mostly, CO and Vl sensors). Utilizing these built-in sensors, it is possible to develop an algorithm to estimate the amount of pollutants exhausted from the each class of cars passing through the tunnel. These estimated data can be effectively utilized not only for ventilation control but also for designing ventilation facilities. The diffusion of pollutants in a tunnel can be described with one-dimensional diffusion-convection equation. This equation is approximated with interpolation functions and weighted residual method converting to adequate form for standard state estimate algorithms. With this converted equations, a least square optimization based algorithm is developed, whose outputs are the estimated amounts of pollutants emitted from each class of cars. In order to verify the feasibility of the developed algorithms, simulations are performed with the real data acquisitioned from the Tunnae tunnel located in Young-Dong highway in Korea.

Comprehensive Field Measurement of Indoor Air and Thermal Quality in Naturally Ventilated Office Building with Double-Skin Façade

  • Ito, Kazuhide;Shiraishi, Yasuyuki
    • 국제초고층학회논문집
    • /
    • 제2권4호
    • /
    • pp.293-314
    • /
    • 2013
  • Double-Skin Façade (DSF), which is a kind of passive indoor environmental control technique, is effective way to control environmental loads while maintaining the transparency especially in perimeter zone and hence the adoption example of DSF keep increasing recently. The objective of this study was to perform a field survey of air quality environment with natural ventilation through DSF and thermal environment within office building with six stories during a mild climate period in Japan. Moreover, to understand the comprehensive environmental performance of the target building, questionnaire survey was conducted to subjectively evaluate the productivity and satisfaction with the environmental factors in office space. In this field measurement, there was a positive correlation between the DSF internal ventilation flow and the amount of solar radiation on the DSF normal surface; the primary driving force for ventilation in the DSF was considered to be the buoyancy force caused by solar radiation. The results of questionnaire survey with regard to productivity level indicated the need for improvement in the thermal (temperature) and spatial environment (room size and furniture placement).

강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험 (Simulation and Verification Experiment of Cooling and Heating Load for a Test Space with Forced Ventilation)

  • 김동혁;홍희기;유호선;김욱중
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.947-954
    • /
    • 2006
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling and heating loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8 : 30 to 21 : 00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual thermal loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Heating load and cooling load including sensible and latent were compared between by experiment and by simulation. Both of thermal loads associated with ventilation show a close agreement within an engineering tolerance.

실측을 통한 신축공동주택의 실내공기질에 관한 연구 (The Study on the Indoor Air Quality in a Newly Built Apartment Rouse by Field Measuring)

  • 이경희;배종수;조성우;박민용;박창섭;최정민
    • 한국주거학회논문집
    • /
    • 제17권4호
    • /
    • pp.111-117
    • /
    • 2006
  • The harmfulness of HCHO and VOCs from construction material and furniture has been increased gradually. It must be need to prevent pollution materials' accumulation indoor effectively and to remove very small amount of harmful pollution materials in various plans, because these kinds of pollution materials greatly affect human body, Therefore, this study is focused to find out the improvements of Indoor Air Quality in execution of natural ventilation and bakeout to reduce indoor chemical pollution materials or not. After effects of indoor air quality by natural ventilation and bake-out being examined, it is follows the conclusion. As for the density change of TVOC and Toluene according to time lapse, in case the middle and high-story areas have bake-out, the density increased once, but it showed the gradual decrease after bake-out was stopped, and it was shown that it exceeded the standards recommended for newly built apartment. The bake-out is effective to discharge the HCHO and TVOC from the construction material and the furniture, and the natural ventilation is effective remove the indoor pollution materials.

신축아파트 환기방식에 따른 실내공기질 변화와 이에 대한 시뮬레이션 및 건강 위해성 평가 (Simulation and Health Risk Evaluation of Indoor Air Quality Changes by Ventilation System in New Apartment)

  • 포위;정재연;정인수
    • 한국농촌건축학회논문집
    • /
    • 제23권4호
    • /
    • pp.38-45
    • /
    • 2021
  • In this study, air quality conditions were identified and analyzed in real time, at the same time, living habits and ventilation methods were maintained in the daily life of residents, and thus, this present study focuses on the lifestyles of residents. Previous studies showed a difference from this study, focusing on the study on the effects of changes in indoor air quality on human health according to the indoor air quality process test standards of the Ministry of Environment. Formaldehyde concentrations exceeded all ventilation standards, but satisfied the organic standards of the Ministry of Environment when ventilation devices and air purifiers were activated. As such, it was investigated that a large amount of formaldehyde emission in the condo is initially ventilated, but a certain concentration is maintained. The change in PM2.5 concentration according to the ventilation method showed a clear difference. As a result of simulating indoor air flow during natural ventilation, the effects of wind speed and wind direction affect the flow rate of indoor air, and indoor polluted air is stagnant even in the presence of wind and is not completely discharged. When the risk assessment results are averaged on the day of measurement, the trends of change between adults and children are almost equivalent, but the results address that children are more sensitive to risk than adults.

공동주택단지배치의 간극비와 바람장의 상관관계에 관한 연구 (A Study on Correlations of the Gap Ratio of Apartment Houses Arrangement and the Wind Field)

  • 문출성;오세규;조성우
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.75-82
    • /
    • 2011
  • In Korea, the ratio of population in urban areas used to be only 50.1% in 1970, but with the value risen to 90.8% in 2009, urbanization is going on rapidly. Urbanization, which occurs by the rampantly planted buildings, has become major source of raising building density, changing wind direction and reducing wind amount, and such reductions are affecting even inside the building. In each year, among the total energy consumption in Korea, residential portion takes up significant ratio, and specifically the ratio of apartment house is shown to be highest. In order to solve such problem, many studies are being conducted for the improvement of natural ventilation performance. The natural ventilation performance of apartment house are significantly determined by the characteristics of external and internal structure, but in macroscopic perspective, the performance is established fundamentally by the layout characteristics of the main building of the apartment house in preparation for wind conditions. So far researches on raising the thermal comfort through elevation of ventilation performance have been conducted actively, but many of them propose only theoretical concepts deduced through wind path analysis, and do not include any indicator to measure ventilation performance simply only with area data from layout planning stage. Therefore, in this study, gap ratio a wind field measuring indicator was developed, and after the ventilation characteristics by layout types and main building uniformity were identified, the scope of gap ratio efficient for ventilation and that of uniformity were clarified, followed by verification through simulation.

유기인계 농약 중독환자에서 기계환기 필요성에 대한 예측인자 분석 (The Factors that Predict Using Mechanical Ventilation for Patients with Organophosphate Intoxication)

  • 박동찬;박정배;김윤정;신수정;문유호;박신률;류현욱;서강석;정제명
    • 대한임상독성학회지
    • /
    • 제8권2호
    • /
    • pp.106-112
    • /
    • 2010
  • Purpose: The purpose of this study is to investigate the factors that predict using mechanical ventilation for patients with organophosphate intoxication. Methods: We retrospectively reviewed the medical records of 111 patients with acute organophosphate intoxication and who were treated in our emergency center from January 2000 to December 2008. We compared the toxicologic characteristics, the laboratory findings and the APACHE II scores between the Mechanical Ventilation group (MV group) and the non-Mechanical Ventilation group (the non MV group). Results: Sixty three patients were in the MV group and 48 patients were in the non MV group. In the MV group, the patients had an older age (p<0.001), a larger amount of ingestion (p<0.001), a lower initial serum cholinesterase level (p=0.003), a higher APACHE II score (p<0.001) and they ingested a more toxic agent (p=0.001). There were no significant differences in gender, the type of visit and the arrival time between the MV group and the non MV group. Conclusion: We suggest that the patient's age, the amount of organophosphate ingestion, the toxicity of the agent, the initial serum cholinesterase level and the APACHE II score are important factors to determine if mechanical ventilation will be applied for patients with organophosphate intoxication.

  • PDF