Effects of Pre-Oxidation for Recirculation of Aquaculture Wastewater (양어용수 재이용을 위한 전 산화처리의 효과)

  • Lim, Jae-Lim;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.103-111
    • /
    • 2000
  • Ozonation and advanced oxidation($H_2O_2/O_3$) process were investigated under various experimental conditions to improve the efficiency of biological filter used for the treatment of recycled wastewater from aquaculture. Ammonia removal followed the first-order reaction whose reaction rate constant(k) was $2.0{\times}10^{-2}min^{-1}$ in ozonation. The ammonia removal rate increased according as the bicarbonate alkalinity is increased. About 46% $NH_3$ was oxidized by ozone at 200 mg/L as $CaCO_3$. When alkalinity existed in wastewater, ammonia removal rate by advanced oxidation was very low due to the inhibition effect of bicarbonate. However, when initial pH was adjusted to about 8.2 by 0.1 N KOH, ammonia removal rate was improved higher than that by ozonation. Especially. ammonia removal rate was the highest at $H_2O_2/O_3$ of 0.25 and about 90% of ammonia was removed in 30 min at this ratio as pH was maintained over 9. In the case of wastewater containing ammonia and organic constituents, ammonia removal efficiency by both ozonation and advanced oxidation decreased seriously because organic constituents consumed the oxidant faster than ammonia. In addition the optimal $H_2O_2/O_3$ ratio was changed. Like ammonia removal, DOC(dissolved organic carbon) increased for first 10 min and then decreased slowly because the particulate organic constituents were oxidized rapidly and then produce DOC. Even when the ammonia concentration by twice, oxidation of DOC was not retarded.

  • PDF

Study of Toxic Gas Removal Characteristics by Chemical Analysis of Essential Oil using SPME Method (SPME법을 이용한 식물정유 성분분석을 통한 유해가스 제거 특성연구)

  • 박영규
    • KSBB Journal
    • /
    • v.19 no.3
    • /
    • pp.231-235
    • /
    • 2004
  • This paper was investigated to clarify the possibility of ammonia gas removal by essential oil. First of all, the chemical analysis was peformed to analyze the composition of an essential oil by GC-MS. The monoterpenes in an essential oil react with ammonia by neutralization and their reaction mechanism was elucidated. Based on their chemical neutralized reaction, the removal efficiencies of ammonia gas were studied to derive the optimal conditions in the scrubber tower such as optimal temperature and pH. The experimental result shows that the removal efficiency of ammonia gas was achieved over 98 % by the misty aerosol dispersion of scrubber tower.

Removal of Ammonia Nitrogen and Reduction of THMs in Low Temperature by BAC Pilot Plant (BAC Pilot Plant 를 이용한 겨울철 암모니아성 질소 제거 및 THMs 변화)

  • Kang, Eun-Jo;Seo, Young-Jin;Lee, Won-Kwon;Chun, Pyoung-Hee;Lee, Ji-Hyung;Yoon, Jung-Hyo;Kim, Dong-Youn
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.4
    • /
    • pp.107-114
    • /
    • 1995
  • The raw drinking water quality is getting worse because of the winter drought and the conventional treatment system is'nt suitable to obtain the satisfied quality of water. So, the advanced water system, BAC(Biological Activated Carbon) process is said to be effective to remove dissolved organics and ammonia nitrogen. In our study, the BAC pilot plant using Nak-dong river water is tested in low temperature. Following results are found from the study. The ammonia nitrogen removal rate of BAC system using wood-based carbon (PICABIOL) was 99% in $6^{\circ}C$ temperature. Chlorine dosage in wood-based BAC effluent was reduced to 67% of that in sand filtered wate. It resulted from the removal of ammonia nitrogen. Also, THM formed by chlorine addition in wood-based BAC effluent was decreased to 65% of that in sand filtered water. In the case of dual-filter, the removal efficiency of ammonia nitrogen was increased 30% more than in conventional sand filter. According to this result, the ammonia nitrogen load to BAC system could be lessened by the use of dual-filter.

  • PDF

Effect of Pre-NH3 Stripping on the Advanced Sewerage Treatment by BNR (BNR에 의한 하수의 고도처리에 미치는 NH3 스트리핑 전처리의 영향)

  • Seo, Jeong-Beom;An, Kwang-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.846-850
    • /
    • 2006
  • The biological nutrient removal from domestic wastewater with low C/N ratio is difficult. Therefore, this study was performed to increase influent C/N ratio by ammonia stripping without required carbon source and for improving treatment efficiencies of sewerage by the combination process of ammonia stripping and BNR (StripBNR). The results of this study were summarized as follows. BOD removal efficiencies of BNR and StripBNR were 95.3% and 93.2%, respectively. T-N and T-P removal efficiencies of BNR were 53.3% and 40.8%, respectively. T-N and T-P removal efficiencies of StripBNR were 72.8% and 62.9%, respectively. Concentrations of $NH_3-N$, $NO_2-N$ and $NO_3-N$ at BNR effluent were 0.03 mg/L, 0.08 mg/L and 9.12 mg/L, respectively. On the other hands, concentrations of $NH_3-N$, $NO_2-N$ and $NO_3-N$ at StripBNR effluent were 5.79 mg/L, 0.01 mg/L and 0.14 mg/L, respectively. Consequently, influent C/N ratio of BNR process was increased by ammonia stripping. Removal efficiency of T-N and T-P was improved about 20% by the process of StripBNR.

Towards a novel approach to improve drinking water quality at Dhaka, Bangladesh

  • Serajuddin, Md.;Chowdhury, Md. Aktarul Islam
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.136-142
    • /
    • 2018
  • The river water source of Saidabad Surface Water Treatment Plant at Dhaka, Bangladesh, is deteriorated too much to be treated by conventional treatment process due to excessive ammonia pollution. In order to improve the raw water quality before it enters into the main treatment chain, a pilot study was conducted for pre-treatment of the raw water. The objective is to investigate the rate of reduction of ammonia using the Meteor pilot, a biological pretreatment system, which is a laboratory scale Moving Bed Biofilm Reactor with a nominal volume of hundred liters, filled with 50 L of Meteor 660 media. The reduction of ammonia was quite significant on average 73%, while the reduction of COD was in a range from 20 to 60%. The Meteor pilot was able to treat and nitrify the raw water and produce an effluent that respects the guarantee of ammonia < $4.0mg\;NH_3-N/L$ when the raw water ammonia concentration was < $15mg\;NH_3-N/L$. The study identified operating parameters necessary to achieve the desired goal of adequate ammonia removal. The study results would benefit a range of systems across the country by providing guidance on the design and operation of a biological pre-treatment system for ammonia removal.

Application of Ferrate (VI) for Selective Removal of Cyanide from Plated Wastewater (도금폐수 중 시안(CN)의 선택적 제거를 위한 Ferrate (VI) 적용)

  • Yang, Seung-Hyun;Kim, Younghee
    • Clean Technology
    • /
    • v.27 no.2
    • /
    • pp.168-173
    • /
    • 2021
  • The treatment of plated wastewater is subject to various and complex processes depending on the pH, heavy metal, and cyanide content of the wastewater. Alkali chlorine treatment using NaOCl is commonly used for cyanide treatment. However, if ammonia and cyanide are present simultaneously, NaOCl is consumed excessively to treat ammonia. To solve this problem, this study investigated 1) the consumption of NaOCl according to ammonia concentration in the alkaline chlorine method and 2) whether ferrate (VI) could selectively treat the cyanide. Experiments using simulated wastewater showed that the higher the ammonia concentration, the lower the cyanide removal rate, and the linear increase in NaOCl consumption according to the ammonia concentration. Removal of cyanide using ferrate (VI) confirmed the removal of cyanide regardless of ammonia concentration. Moreover, the removal rate of ammonia was low, so it was confirmed that the ferrate (VI) selectively eliminated the cyanide. The cyanide removal efficiency of ferrate (VI) was higher with lower pH and showed more than 99% regardless of the ferrate (VI) injection amount. The actual application to plated wastewater showed a high removal ratio of over 99% when the input mole ratio of ferrate (VI) and cyanide was 1:1, consistent with the molarity of the stoichiometry reaction method, which selectively removes cyanide from actual wastewater containing ammonia and other pollutants like the result of simulated wastewater.

Factors Influencing the Removal of Nutrient by Seawater (해수에 의한 영양염 제거에 있어서 영향인자의 평가)

  • Cortes, Aiza;Kim, Woo-Hang
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2009.06a
    • /
    • pp.145-147
    • /
    • 2009
  • Nutrients in wastewater should be removed prior to release in the receiving waters to prevent the occurrence of eutrophication. In this study, seawater is used to remove ammonia and phosphate by the formation of struvite ($MgNH_{4}PO_{4}{\cdot}6H_{2}O$). It aims to know the optimum conditions for the removal of nutrients using seawater as source of magnesium ions. Experiments were performed using jar tester and pH of ammonium-phosphate solutions were adjusted Samples were drawn at different mixing times. It was shown that simultaneous removal of ammonia and phosphate is rapid, with no significant reduction beyond 10 min of mixing Another important parameter is pH, where range 10-11 showed the optimum nutrient removal. Increase in the volume of seawater, which meant an increase in magnesium ions also lead to better removal.

  • PDF

Aqeous Neutralizer as Reactive Solvents for Odorous Ammonia Removal

  • Park, Young-G.
    • Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.119-124
    • /
    • 2008
  • Ammonia is an inorganic compound that may cause severe odor problem. In this study the effectiveness of applying natural neutralizer to destroy and remove the odor-causing compound from gas streams was studied. Experimental result evaluated with a bench-scale apparatus via the neutralization of gas phase. This indicates that the natural neutralization depends on the gas concentration, gas residence time, temperature and pH. Removal efficiency of ammonia from gas stream was achieved by 95% using theconvection in the packed bed. This study proved the chemical neutralization technology was effective for controlling inorganic odor-causing compound.

Performance Assessment of Electrolysis Using Copper and Catalyzed Electrodes for Enhanced Nutrient Removal from Wastewater

  • Kim, Woo-Yeol;Son, Dong-Jin;Yun, Chan-Young;Kim, Dae-Gun;Chang, Duk;Sunwoo, Young;Hong, Ki-Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.124-132
    • /
    • 2017
  • The performance of electrolytic processes using copper and catalyzed electrodes for enhanced nutrient removal with various catalyzers and combinations of electrodes was evaluated. The catalyzed electrodes removed more ammonia nitrogen than the copper electrode, but higher ammonia removal was achieved using a Pt/Ti anode. On the other hand, electrolysis using the Pt/Cu anode consumed less energy and cost less. During electroreduction, nitrate was better removed by a pair of copper electrodes than by the catalyzed electrodes. During electrolysis of synthetic wastewater, ammonia removal not only increased owing to direct oxidation at the anode, but was also influenced by indirect oxidation at the cathode. Platinum-coated copper and titanium cathodes actively produced oxidizers and thus removed more ammonia than a pure metal cathode. Although phosphorus was removable irrespective of the type of catalyzer, electrocoagulation using the copper electrode achieved complete removal of phosphorus in a period of less than 10 min.