• Title/Summary/Keyword: ambient cold

Search Result 169, Processing Time 0.031 seconds

Effects of ambient temperature and rumen-protected fat supplementation on growth performance, rumen fermentation and blood parameters during cold season in Korean cattle steers

  • Kang, Hyeok Joong;Piao, Min Yu;Park, Seung Ju;Na, Sang Weon;Kim, Hyun Jin;Baik, Myunggi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.5
    • /
    • pp.657-664
    • /
    • 2019
  • Objective: This study was performed to evaluate whether cold ambient temperature and dietary rumen-protected fat (RPF) supplementation affect growth performance, rumen fermentation, and blood parameters in Korean cattle steers. Methods: Twenty Korean cattle steers (body weight [BW], $550.6{\pm}9.14kg$; age, $19.7{\pm}0.13months$) were divided into a conventional control diet group (n = 10) and a 0.5% RPF supplementation group (n = 10). Steers were fed a concentrate diet (1.6% BW) and a rice straw diet (1 kg/d) for 16 weeks (January 9 to February 5 [P1], February 6 to March 5 [P2], March 6 to April 3 [P3], and April 4 to May 2 [P4]). Results: The mean and minimum indoor ambient temperatures in P1 ($-3.44^{\circ}C$, $-9.40^{\circ}C$) were lower (p<0.001) than those in P3 ($5.87^{\circ}C$, $-1.86^{\circ}C$) and P4 ($11.18^{\circ}C$, $4.28^{\circ}C$). The minimum temperature in P1 fell within the moderate cold-stress (CS) category, as previously reported for dairy cattle, and the minimum temperatures of P2 and P3 were within the mild CS category. Neither month nor RPF supplementation affected the average daily gain or gain-to-feed ratio (p>0.05). Ruminal ammonia nitrogen concentrations were higher (p<0.05) in cold winter than spring. Plasma cortisol concentrations were lower (p<0.05) in the coldest month than in the other months. Serum glucose concentrations were generally higher in colder months than in the other months but were unaffected by RPF supplementation. RPF supplementation increased both total cholesterol (p = 0.004) and high-density lipoprotein (HDL) concentrations (p = 0.03). Conclusion: Korean cattle may not be significantly affected by moderate CS, considering that the growth performance of cattle remained unchanged, although variations in blood parameters were observed among the studied months. RPF supplementation altered cholesterol and HDL concentrations but did not affect growth performance.

Performance differences of Rhode Island Red, Bashang Long-tail Chicken, and their reciprocal crossbreds under natural cold stress

  • Xie, Shanshan;Yang, Xukai;Gao, Yahui;Jiao, Wenjie;Li, Xinghua;Li, Yajie;Ning, Zhonghua
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.10
    • /
    • pp.1507-1514
    • /
    • 2017
  • Objective: The Bashang Long-tail chicken (BS), an indigenous Chinese breed, is considered cold tolerant. We selected BS, the Rhode Island Red (RIR), and their reciprocal crossbreds for the present study. The objectives were: i) to validate whether BS is cold tolerant and whether egg production and cold tolerance of crossbreds could be improved; and ii) to determine the physiological characteristics that underlie cold tolerance and favorable egg production performance in cold environments. Methods: A total of 916 chickens were reared in warm and natural cold environments (daily mean ambient temperature varied from $7.4^{\circ}C$ to $26.5^{\circ}C$ in the warm environment and from $-17.5^{\circ}C$ to $27.0^{\circ}C$ in the cold environment). To investigate their adaptability to the cold environment, the egg production performance and body weight were monitored and compared between breeds and environments. The cloacal temperature and serum biochemical parameters were monitored to reveal the physiological characteristics underlie cold tolerance and favorable egg production performance in the cold environment. Results: The warm environment experiment showed that RIR had the highest egg production performance, and that the reciprocal crossbreds had a higher egg production performance than BS. While in the cold environment RIR had the lowest egg production performance, and the reciprocal crossbreds had a higher egg production performance than BS. In the cold environment BS and reciprocal crossbreds had higher triiodothyronine, tetraiodothyronine levels than RIR. At 35 and 39 wk of age, when the ambient temperature was extremely low (varied from $-20^{\circ}C$ to $0^{\circ}C$), serum glucose, follicle-stimulating hormone, luteinizing hormone, estradiol of BS and crossbreds were higher than RIR. Conclusion: Bashang Long-tail chicken has a favorable cold tolerance ability. Crossbreeding with RIR and BS is an effective way to develop cold tolerant chickens with improved egg production performance.

Low Temperature Storage of Rough Rice Using Cold-Air in Winter (II) - Low Temperature Storage Characteristics of Rough Rice Using a Cooling System in the Top of a Bin - (겨울철 냉기를 이용한 벼의 저온저장 (II) - 빈상부 쿨링시스템을 이용한 냉각 벼의 저온저장 특성 -)

  • Lee, Jae-Seok;Hong, Hyun-Ki;Li, He;Park, Jong-Soo;Ham, Tack-Mo;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.32 no.1 s.120
    • /
    • pp.13-19
    • /
    • 2007
  • Storage rough rice in low temperature using the winter cold air avoids rough rice temperature increase which happens from early May, and this is possible by installing a cooling system in the top of a bin, the room between top rice level and bin ceiling. The research objective is to establish low temperature rough rice storage technique, furnishing winter cold air to rough rice, by investigating the cooling system potential of maintaining low rough rice temperature and by analyzing rough rice storage characteristics over a storage period. The rough rice storage characteristics were evaluated from January to August 2003, using a storage and dry bin of 400-ton capacity. Results of this research are as follows: Cooling bin using the cooling system in the top of the bin maintained the rice temperature less than 15$^{\circ}C$ in entire portions in August. Moisture contents and germination rates of rough rice were decreased over the storage period, on the other hand, the rough rice stored in the ambient temperature bin had relatively lower moisture contents and germination rates to compare with the bin using winter cold air. Crack ratio and acid value of brown rice in the ambient temperature bin storage had increased more than the cooling bin storage. The result indicates that the storage bin using winter cold air and the cooling system maintains moisture content and germination of rice, minimizes cracked kernel and acid value, and preserves rice quality as well.

Low Temperature Storage of Rough Rice Using Cold-Air in Winter(I) - Storage Characteristics after Rough Rice Cooling - (겨울철 냉기를 이용한 벼의 저온저장(I) - 벼 냉각 후 저장특성 -)

  • Lee J. S.;Han C. S.;Ham T. M.;Yon K. S.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.155-160
    • /
    • 2005
  • The objective of this research was to establish a domestically available cooling storage technique by cold-air in winter, using winter cool air ventilation fur determining rough rice cooling method in the storage and dry bin. The rough rice storage characteristics of two test conditions, winter cool-air ventilation storage and ambient temperature storage, were evaluated from January to July 2001, using a storage and dry bin of 300-ton capacity. Results of this research are as follows: Grain temperature was from $-5.1\~-8.5^{\circ}C$ after winter cool-air ventilation, and grain initial temperature for ambient temperature bin storage was $0.3\~1.9^{\circ}C$. Moisture content of rough rice decreased from $0.28\;to\;0.93\%$ and from $1.53\;to\;1.92\%$ to compare with original moisture contents for winter cool-air ventilation, and for ambient temperature bin storage, respectively. Broken ratio of brown rice from winter cool-air ventilation bin increased from $0.16\;to\; 0.92\%$, and brown rice broken ratio was from $2.24\;to\;2.86\%$ for ambient temperature bin storage to compare with initial broken ratio. Hardness of stored rice increased along storage period increase in alt storage methods, and cooling bin storage increased rice hardness of 0.271kgf: this increasing was lower then the other methods from 0.059 to 2.239kgf. Germination rates were decreased approximately 9.03, 3.14 and $3.20\%$ for upper, middle, and bottom of ventilating winter air bin, respectively, and germination rates of 2.70, 3.47 and $4.14\%$ were approximately decreased for upper, middle, and bottom parts of ambient temperature bin storage, respectively.

Analysis of Performance of Building Integrated PV System into Cold Facade (건물일체형 Cold Facade PV 시스템의 성능 분석)

  • Kim, Hyun-Il;Kang, Gi-Hwan;Park, Kyung-Eun;Yu, Gwon-Jong;Suh, Seung-Jik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1104-1105
    • /
    • 2008
  • This paper presents the assesment of experimented data and estimated data for electrical and thermal performance evaluation of building integrated photovoltaic(BIPV) system of cold facade type. BIPV module is used to estimate the dependence of module temperature on irradiance, ambient temperature and indoor temperature. The module temperature of no free ventilated facade PV system is higher than cold facade PV system about 13.4$^{\circ}C$. By the results on simulation, the reduction of electrical power loss is 9.57% into cold facade according to free ventilation. The annual averaged PR of BIPV system into cold facade is about 73.1%.

  • PDF

The Basic Insulation Design of 60 kV Bushing for Netural Line of 154 kV Class HTS Transformer (154 kV급 고온초전도 변압기의 중성선용 60 kV 부싱의 기초 절연설계)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.32-35
    • /
    • 2008
  • A common problem in many fields of cryogenic power engineering is applying high voltage to cold parts of superconducting apparatus. In many cases, a bushing provides electrical insulation for the conductor which makes the transition from ambient temperature to the cold environment. The 60 kV class cryogenic high voltage bushing for neutral line of the 154 kV / 100MVA high temperature superconducting (HTS) transformer was described. The bushing is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors; in the axial direction, there was a temperature difference from ambient to about 77 K. For the insulation design of cryogenic bushing, electrical insulation characteristics of the GFRP were discussed in this paper.

Temperature Change in the Largest Industrial City, Korea

  • Lee, Byeong-Kyu;Lee, Sang-Tae
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.194-204
    • /
    • 2015
  • This study analyzed a change trend of ambient temperature over the last sixty years in the largest industrial city in Korea, Ulsan. Linear warming rates in Ulsan over the last 25 (1985 to 2009), 40 (1970 to 2009), and 60 (1950 to 2009) years were 0.0507, 0.0416, and $0.0277^{\circ}C/yr$, respectively. The annual average temperature (AAT) and the annual average of the daily lowest temperature (AADLT) in Ulsan increased 1.3 and $2.9^{\circ}C$, respectively, over the last fifty years (1960 to 2009). The increasing slopes of the AAT and AADLT over the fifty years in Ulsan were higher or much higher than those in neighboring cities and on a global scale. In the comparison analysis of daily average temperature over the most recent ten years, the highest ($15.9^{\circ}C$) was observed in the industrial area followed by the downtown, coastal, suburban, and rural areas with 14.6, 14.5, 14.0, and $12.8^{\circ}C$, respectively. The number of cold days less than $5.0^{\circ}C$ decreased, while the number of hot days higher than $20.0^{\circ}C$ increased. The decreasing slopes in the cold days in lower latitude cities were steeper than those in higher latitude cities in Korea.

Diffusion Modelling of Cold Discharge on Coastal waters (연안역의 냉배수 확산모델링)

  • Kim, Jong-Kyu;Kim, Jong-Hwa
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.13 no.2
    • /
    • pp.132-145
    • /
    • 2001
  • The cold discharge from LNG(liquefied natural gas) terminal makes the water temperature around the terminal fall down. This temperature reduction may result in serious changes on marine ecosystem of the coastal area. The numerical model experiments of material transport and tidal circulation in the inner bay, Chinhae Bay are investigated in the dispersion of cold discharge from LNG terminal. The condition of ambient water is exposed to tide, tidal current and cold discharge temperature. Simple numerical model experiments highlight the importance of tidal circulation and cold discharge at each case and some results are discussed. The results of this study can be used as the guideline for the site selection of LNG terminals and long-term marine environmental impact assessment.

  • PDF

Effects of Direct Moxibustion Applied to EX-LE4 and EX-LE5 on the Pain Behavior and Expression of TRPM8 in the Rat Model of Ambient Cold Exposed Osteoarthritis (추위에 노출된 슬관절염 모델에서 내슬안, 외슬안 직접구가 통증행동과 TRPM8 발현에 미치는 영향)

  • Ji, Byeong Uk;Kim, Yiquot;Lee, Ji Eun;Koo, Sungtae
    • Korean Journal of Acupuncture
    • /
    • v.33 no.4
    • /
    • pp.204-212
    • /
    • 2016
  • Objectives : The aim of the study is to investigate the effects of moxibustion on the pain behavior and expression of TRPM8 in the dorsal root ganglion(DRG) in the rat model of ambient cold(AC) exposed osteoarthritis(OA). Methods : OA was induced by the injection of $50{\mu}l$ of 2% monosodium iodoacetate(MIA) into the knee joint cavity. To examine the level of pain, weight bearing forces(WBFs) of affected limb was measured. For the AC exposure, the animals were housed in 6 h/day at $4^{\circ}C$ for 14 days after MIA injection. Moxibustion treatment was performed at EX-LE4 and EX-LE5 with 5 cons(1, 7 or 10 mg) per day for 13 days from 5 days after MIA injection. The expressions of TRPM8 in DRG were measured by western blotting analysis. Results : The WBFs of MIA-AC group were decreased significantly compared to MIA group at 2, 3, 6, 7, 8 and 9 days after arthritis induction. After the first 6 h-AC exposure, expressions of TRPM8 in MIA-AC group were increased significantly compared to those of naive group. After moxibustion treatment, only the WBFs of 7 mg treated group were restored significantly. Moreover, the over-expressions of TRPM8 were attenuated by the moxibustion treatment in AC exposed rats. Conclusions : The data suggest that AC can increase arthritic knee pain via up-regulated TRPM8 and moxibustion treatment improve the arthritic pain via modulation of TRPM8 expression in DRG in the rat model of AC exposed MIA induced arthritis.

A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere (환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구)

  • Son, Eun-Seong;Seo, Young-Kyo;Lee, Dong-Hyun;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.