• Title/Summary/Keyword: ambient air

Search Result 1,457, Processing Time 0.027 seconds

The Operation Characteristics of a Sea Water Source Heat Pump System (해수열원 히트펌프 시스템의 운전특성)

  • Chang, Ki-Chang;Baik, Young-Jin;Ra, Ho-Sang;Kim, Ji-Young;Lee, Jae-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1353-1357
    • /
    • 2008
  • A sea water source cascade heat pump was designed and tested in this study. The system was designed to perform a single stage operation in summer, as well as a cascade operation in winter to ensure the high temperature lift. A steady-state simulation model was developed to analyze and optimize its performance. The simulation results show that the R717 exhibits best performance among combinations considered in this study. A R410A also exhibits the highest performance among HFCs with the smallest compressor displacement. A 15-RT R410A-R134a pilot system was installed in the 5-story commercial building at Samcheok City by the East Sea. A scroll type R410A compressor, a reciprocating type R134a compressor, plate type condenser/ evaporator/ cascade heat exchanger and two electronic expansion valves were used to build a pilot. A titanium plate type heat exchanger is also used for the heat exchanging with a sea water. The heat source/sink water is supplied from the well below the seashore in the depth of 5 m. In the initial test of the system, supply water temperature was rising up to $67^{\circ}C$ using a sea water heat source of $9^{\circ}C$, while an ambient temperature was $4.5^{\circ}C$.

  • PDF

A Design and Test of a Sea Water Source Heat Pump System (해수열원 히트펌프 시스템의 설계 및 운전)

  • Lee, Jae-Hun;Kim, Ji-Young;Baik, Young-Jin;Chang, Ki-Chang;Ra, Ho-Sang;Shin, Kwang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1273-1278
    • /
    • 2008
  • A sea water source cascade heat pump was designed and tested in this study. The system was designed to perform a single stage operation in summer, as well as a cascade operation in winter to ensure the high temperature lift. A steady-state simulation model was developed to analyze and optimize its performance. The simulation results show that the R717 exhibits best performance among combinations considered in this study. A R410A also exhibits the highest performance among HFCs with the smallest compressor displacement. A 15-RT R410A-R134a pilot system was installed in the 5-story commercial building at Samcheok City by the East Sea. A scroll type R410A compressor, a reciprocating type R134a compressor, plate type condenser/ evaporator/ cascade heat exchanger and two electronic expansion valves were used to build a pilot. A titanium plate type heat exchanger is also used for the heat exchanging with a sea water. The heat source/sink water is supplied from the well below the seashore in the depth of 5 m. In the initial test of the system, supply water temperature was rising up to $67^{\circ}C$ using a sea water heat source of $9^{\circ}C$, while an ambient temperature was $4.5^{\circ}C$.

  • PDF

The Effects of Fuel Temperature on the Spray and Combustion Characteristics of a DISI Engine (직접분사식 가솔린 엔진에서 연료 온도에 따른 팬형 분무 및 연소 특성의 변화)

  • Moon, Seok-Su;Abo-Serie, Essam;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.103-111
    • /
    • 2006
  • The spray behavior of direct-injection spark-ignition(DISI) engines is crucial for obtaining the required mixture distribution for optimal engine combustion. The spray characteristics of DISI engines are affected by many factors such as piston bowl shape, air flow, ambient temperature, injection pressure and fuel temperature. In this study, the effect of fuel temperature on the spray and combustion characteristics was partially investigated for the wall-guided system. The effect of fuel temperature on the fan spray characteristics was investigated in a steady flow rig embodied in a wind tunnel. The shadowgraphy and direct imaging methods were employed to visualize the spray development at different fuel temperatures. The microscopic characteristics of spray were investigated by the particle size measurements using a phase Doppler anemometry(PDA). The effect of injector temperature on the engine combustion characteristics during cold start and warming-up operating conditions was also investigated. Optical single cylinder DISI engine was used for the test, and the successive flame images captured by high speed camera, engine-out emissions and performance data have been analyzed. This could give the way of forming the stable mixture near the spark plug to achieve the stable combustion of DISI engine.

Preparation and characterization of nanoporous monolith with high thermal insulation performance (나노 기공성 단열 실리카 모노리스 제조 및 특성 연구)

  • Choi, Hyun-Muk;Kim, Seong-Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.83-91
    • /
    • 2014
  • In this study, we synthesized two different silica monoliths by using sol-gel, solvent exchange, surface modification, ambient pressure drying processes, and surfactant-based templating technique followed by calcination process. All of the prepared two silica monoliths showed crack-free appearance with fairly good transparency, and furthermore were confirmed to have extremely high porosity, specific surface area, and mean pore size below 30 nm. The silica aerogel sample exhibited finer and more homogeneous nano-sized pore structure due to spring back effect caused by surface modification, which resulted in better thermal insulation performance. Based on measured thermal conductivities and theoretical relationship, multi-layered glass window system in which silica monolith prepared in this study was inserted as a middle layer was revealed to have superior thermal insulation performance compared to conventional air-inserted glass window system.

Diffusion Behaviors and Electrical Properties in the In-Ga-Zn-O Thin Film Deposited by Radio-frequency Reactive Magnetron Sputtering

  • Lee, Seok Ryeol;Choi, Jae Ha;Lee, Ho Seong
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.322-328
    • /
    • 2015
  • We investigated the diffusion behaviors, electrical properties, microstructures, and composition of In-Ga-Zn-O (IGZO) oxide thin films deposited by radio frequency reactive magnetron sputtering with increasing annealing temperatures. The samples were deposited at room temperature and then annealed at 300, 400, 500, 600 and $700^{\circ}C$ in air ambient for 2 h. According to the results of time-of-flight secondary ion mass spectrometry and X-ray photoelectron spectroscopy, no diffusion of In, Ga, and Zn components were observed at 300, 400, 500, $600^{\circ}C$, but there was a diffusion at $700^{\circ}C$. However, for the sample annealed at $700^{\circ}C$, considerable diffusion occurred. Especially, the concentration of In and Ga components were similar at the IGZO thin film but were decreased near the interface between the IGZO and glass substrate, while the concentration of Zn was decreased at the IGZO thin film and some Zn were partially diffused into the glass substrate. The high-resolution transmission electron microscopy results showed that a phase change at the interface between IGZO film and glass substrate began to occur at $500^{\circ}C$ and an unidentified crystalline phase was observed at the interface between IGZO film and glass substrate due to a rapid change in composition of In, Ga and Zn at $700^{\circ}C$. The best values of electron mobility of $15.5cm^2/V{\cdot}s$ and resistivity of $0.21{\Omega}cm$ were obtained from the sample annealed at $600^{\circ}C$.

Heat Spreading Properties of CVD Diamond Coated Al Heat Sink (CVD 다이아몬드가 코팅된 알루미늄 방열판의 방열 특성)

  • Yoon, Min Young;Im, Jong Hwan;Kang, Chan Hyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.297-302
    • /
    • 2015
  • Nanocrystalline diamond(NCD) coated aluminium plates were prepared and applied as heat sinks for LED modules. NCD films were deposited on 1 mm thick Al plates for times of 2 - 10 h in a microwave plasma chemical vapor deposition reactor. Deposition parameters were the microwave power of 1.2 kW, the working pressure of 90 Torr, the $CH_4/Ar$ gas ratio of 2/200 sccm. In order to enhance diamond nucleation, DC bias voltage of -90 V was applied to the substrate during deposition without external heating. NCD film was identified by X-ray diffraction and Raman spectroscopy. The Al plates with about 300 nm thick NCD film were attached to LED modules and thermal analysis was carried out using Thermal Transient Tester (T3ster) in a still air box. Thermal resistance of the module with NCD/Al plate was 3.88 K/W while that with Al plate was 5.55 K/W. The smaller the thermal resistance, the better the heat emission. From structure function analysis, the differences between junction and ambient temperatures were $12.1^{\circ}C$ for NCD/Al plate and $15.5^{\circ}C$ for Al plate. The hot spot size of infrared images was larger on NCD/Al than Al plate for a given period of LED operation. In conclusion, NCD coated Al plate exhibited better thermal spreading performance than conventional Al heat sink.

An Experimental Study of Water Vapor Pressure Change by Ambient Temperature at the Interface between Concrete and Fluid-Applied Membrane Layer

  • Ko, Jin-Soo;Kim, Byung-Yun;Park, Sung-Woo;Lee, Mun-Hwan;Lee, Sung-Bok
    • International Journal of Concrete Structures and Materials
    • /
    • v.3 no.1
    • /
    • pp.15-23
    • /
    • 2009
  • Over about 30% of problems in construction is related to water-leaking, and the loss from this problem can incur as much as three times the cost of initial construction. Thus, water vapor pressure is known to be the primary cause of defective waterproofing. Accordingly, the theories on the relationship between water pressure and temperature as well as damp-proofing volume of concrete and the change in vapor pressure volume were reviewed and analyzed in this study by making test samples after spraying a dampness remover and applying waterproofing materials to the prepared test specimens. The result of measuring water vapor pressure with the surface temperature of the waterproofing (fluid-applied membrane) layer at the experimental temperature setting of about $10^{\circ}C$, which is the annual average temperature of Seoul, indicated that (1) the temperature of the fluid-applied membrane elevated to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about 0.03 N/mm 2 when the surface temperature of the waterproofing layer was raised to about $80^{\circ}C$. (2) when the temperature of the fluid-applied membrane of the waterproofing layer was raised from $30^{\circ}C$ to $35^{\circ}C$, water vapor pressure of about 0.01 N/mm 2 was generated, and (3) when a thermal source was applied to the fluid-applied membrane (waterproofing) layer, the temperature increased from $35^{\circ}C$ to $40^{\circ}C$, and approximately $0.005\;N/mm^2$ of water vapor pressure was generated.

Acute Effects of PM10 on Asthma Hospitalization Among Children and Benefit Analysis at Four Major Cities in Korea (PM10이 소아천식 입원에 미치는 급성 영향 및 건강편익 평가 -서울, 인천, 부산, 울산 4개 도시를 중심으로-)

  • Bae, Hyun-Joo;Kim, Myung-Hyun;Lee, Ae-Kyung;Park, Jeong-Im
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • This study assessed the relationships between levels of $PM_{10}$ and hospitalization rates for asthma among children from 2003 to 2005 at four major cities in Korea. In addition, we estimated the reduced number of asthma hospitalization associated with an ambient $PM_{10}$ improvement to the acceptable levels as recommended by the World Health Organization (WHO). The Generalized Additive Model (GAM) was used to estimate the relative risks (RR) of asthma hospitalization associated with changes in $PM_{10}$ The RRs of children's asthma hospitalization for every $10{\mu}g/m^3$ increment in $PM_{10}$ were 1.009(95% CI = 1.004-1.014) in Seoul, 1.013(95% CI = 1.006-1.021) in Incheon, 1.009(95% CI = 1.002-1.016) in Busan, and 1.021(95% CI = 1.005-1.037) in Ulsan. We assessed $PM_{10}$ related health benefits from implementing the WHO's guidelines (24-hour average $50{\mu}g/m^3$) using the U.S. Environmental Protection Agency's Environmental Benefits Mapping and Analysis Program. The estimated benefits were 439(95% CI = 216-666) reduced asthma hospitalization in Seoul, 720(95% CI = 304-1,151) in Incheon, 260(95% CI = 66-459) in Busan, and 126(95% CI = 30-228) in Ulsan. It was concluded that improving $PM_{10}$ condition to the WHO guideline would make a significant contribution to the reduction in asthma hospitalization among children. Therefore, public health measures are still needed to improve air quality in Korea.

Research and Development Status of HALE Aircraft with Turbo-charged Reciprocating Engine (다단 터보차저 시스템이 장착된 왕복동 엔진을 사용하는 고고도 장기체공 항공기 연구개발 현황)

  • Kang, Young Seok;Lim, Byeung Jun;Cha, Bong Jun
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.56-64
    • /
    • 2017
  • A high altitude long endurance aircraft which carries out missions of environmental research communication relay or ground surveillance, should have the capacity to cruise in the stratosphere at a relatively low speed for a long dwell time without the necessity of refueling. When one considers the propulsion system for such an aircraft, a reciprocating engine with a serial turbo-charger system to boost rarefied ambient air up to sea level condition, would represent an good, informed and practical choice regardless of the cruising altitude of the aircraft. In this paper, high altitude long endurance aircraft developed by overseas research groups and research trends, regarding multi-stage turbocharger systems, are introduced.

Estimation of the Effect of Clean Road System on the $PM_{10}$ Concentration at a Heavy Traffic Roadside - A Case study for Daegu City - (클린로드 시스템 가동이 도로변 $PM_{10}$ 농도에 미치는 영향 분석- 대구지역의 사례연구 -)

  • Jo, Byung-Yoon;Baek, Sung-Ok
    • Particle and aerosol research
    • /
    • v.8 no.3
    • /
    • pp.111-120
    • /
    • 2012
  • In Daegu, a road cleaning system was constructed in the central part of the city and has been operated from April, 2011. We evaluated the effect of the system on the concentration of $PM_{10}$ at a roadside monitoring site. The ambient $PM_{10}$ concentration data were logged every 1 min for a period of 20 weeks from May to October, 2011, by means of light scattering method, and then every 5 min data were used in the statistical analysis. The measured data were verified by comparing them with beta-ray data obtained at the same site. Correlation coefficient between the two groups was highly significant (r=0.79), though the absolute levels of light scattering data appeared to be approximately 2.8 times higher than the beta-ray data. Diurnal, daily, weekly, and monthly variations of $PM_{10}$ data did not show any evidence of decreasing effect owing to the clean road system. A comparison of roadside $PM_{10}$ data with non-roadside data also revealed very similar pattern, implying the variation of the $PM_{10}$ concentrations is mainly affected by the traffic conditions near the monitoring site. However, if the operating conditions of the clean road system can be improved, i.e. increasing the frequency and duration of water cleaning, the road cleaning effect may improve the air quality indirectly by means of removing the resuspended particles from the road.