• Title/Summary/Keyword: alternating group

Search Result 85, Processing Time 0.028 seconds

Scanning Electron Microscopic Study of the Effect of Tetracycline-HCl on the Change of Implant Surface Microstructure according to Application Time (염산테트라싸이클린의 적용시간에 따른 임플란트 표면변화에 관한 주사전자현미경적 연구)

  • Kim, Woo-Young;Lee, Man-Sup;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.523-537
    • /
    • 2002
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used. Implant surface was rubbed with 5Omg/ml tetracycline - HCl solution for ${\frac}{1}{2}$ min., 1 min., $1{\frac}{1}{2}$ min., 2 min., and 3min. respectively in the test group and with no conditioning in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. subsequently, the acid-etching process crated the micro roughness, which thus was superimposed on the macro roughness. 3. In the SLA surfaces, irrespective of the application time of 50mg/ml tetracycline-HCl solution, in general, test specimens were similar to control. 4. In the $TiO_2blasted$ surfaces the control specimen showed the rough surface with small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline-HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. In conclusion, pure titanium machined surfaces and SLA surfaces weren't changed irrespective of the application time of tetracycline-HCl solution. And the $TiO_2blasted$ surfaces conditioned with tetracycline - HCl solution began to be changed from $1{\frac}{1}{2}$ min. This results are expected to be applied to the regenerative procedures for peri-implantitis treatment.

Microstructural Change of Implant Surface conditioned with Tetracycline-HCI;SLA and TB surface implant (표면처리 시간에 따른 임플란트 미세구조의 변화;SLA와 TB 표면 임플란트)

  • Woo, Jung-A;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.921-937
    • /
    • 2005
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline- HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml tetracycline - HCl solution for $\frac{1}{2}$ min., 1min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}min.$ respectively in the test group and with no treatment in the control group. The sponge was soaked in every 30 seconds. Then, the specimens were processed for scanning electron microscopic observation. Based upon the analysis of photographs by three dentists who are not related with this study, the results were obtained as follows; 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml tetracycline - HCl solution, in general, test specimens were similar to control. 3. In the $TiO_2blasted$ surfaces, the control specimen showed the rough surface With small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas got wider after 1 minute.

Repeated Intramuscular-dose Toxicity Test of Water-soluble Carthami Flos (WCF) Pharmacopuncture in Sprague-Dawley Rats

  • Choi, Yoo-Min;Jung, Da-Jung;Kim, Seok-Hee;Kim, Jong-Uk;Yook, Tae-Han
    • Journal of Pharmacopuncture
    • /
    • v.18 no.1
    • /
    • pp.36-43
    • /
    • 2015
  • Objectives: Water-soluble carthami flos (WCF) is a new mixture of Carthami flos (CF) pharmacopuncture. We conducted a 4-week toxicity test of repeated intramuscular injections of WCF in Sprague-Dawley rats. Methods: Forty male and 40 female rats were divided into 4 groups of 10 male and 10 female SD rats: The control group received 0.5 mL/animal/day of normal saline whereas the three experimental groups received WCF at doses of 0.125, 0.25, and 0.5 mL/animal/day, respectively. For 4 weeks, the solutions were injected into the femoral muscle of the rats alternating from side to side. Clinical signs, body weights, and food consumption were observed; opthalmological examinations and urinalyses were performed. On day 29, blood samples were taken for hematological and clinical chemistry analyses. Then, necropsy was conducted in all animals to observe weights and external and histopathological changes in the bodily organs. All data were tested using a statistical analysis system (SAS). Results: No deaths were observed. Temporary irregular respiration was observed in male rats of the experimental group for the first 10 days. Body weights, food consumptions, opthalmological examinations, urinalyses, clinical chemistry analyses, organ weights and necropsy produced no findings with toxicological meaning. In the hematological analysis, delay of prothrombin time (PT) was observed in male rats of the 0.25- and the 0.5-mL/animal/day groups. In the histopathological test, a dose-dependent inflammatory cell infiltration into the fascia and panniculitis in perimuscular tissues was observed in all animals of the experimental groups. However, those symptoms were limited to local injection points. No toxicological meanings, except localized changes, were noted. Conclusion: WCF solution has no significant toxicological meaning, but does produce localized symptoms. No observed adverse effect level (NOAEL) of WCF in male and female rats is expected for doses over 0.5 mL/animal/day.

Effects of Early-life Feed Restriction with Diet, Dilution or Skip-feeding Programs on Compensatory Growth, Feed Efficiency, and Abdominal Pat, Pad Deposition in Broilers (사료의 희석 및 무급여일 설정방법에 의한 조기제한사양이 육계의 보상성장과 사료효율 및 복강지방 축적에 미치는 영향)

  • 이규호;오용석;함영훈
    • Korean Journal of Poultry Science
    • /
    • v.29 no.1
    • /
    • pp.37-43
    • /
    • 2002
  • This experiment was conducted to study the effect of early-life feed restriction with diet dilution on compensatory growth, feed efficiency and abdominal fat pad deposition in broilers. In this study, the chicks were randomly assigned to five treatments. Twenty chicks were assigned to each floor pen, and each dietary treatment was replicated with three pens. Birds In control group (C) were full-fed a starter diet throughout the experimental period, and all birds in four dietary treatments (T1-T4) were fed as starter diet diluted with 50% rice hulls. Birds in T1 were fed with a diluted starter diet ad libitum from 7- to 74-d. In T2,the feeding program was 1-d withdrawal alternating with 3-d feed and in T3 1-d withdrawal alternating with 2-d feed. The feeding Program in T4 was alternate days withdrawal and feeding. The feeding with the diluted starter diet (T1) did not significantly affect to growth rate as compared to the birds of C. When periods of 24 h feed withdrawal were Imposed in conjunction with the diluted diets, birds were under weight at 49 d. As the diluted diet treatment was combined with feed withdrawal (T2-T4), there were further less growth. During the 22 to 49 d Period,T1 birds had greater weight gain compared to other treatments (P<0.05) . Birds consumed less feed from 7- to 49-d when the rice hull dilution was used, and this effect was increased by imposition of feed withdrawal (P<0.07) . If rice hull was excluded from the calculation of feed intake (assumed indigestible) then Intake of the starter diet was markedly less for restricted vs. control birds. After 22 d and from 7 to 49 d, restricted birds had superior feed conversion (P<0.05) compared to control birds. Abdominal fat pad deposition and mortality were not influenced by early feed restriction by diluted diet (P<0.05) .

Novel 4,7-Dithien-2-yl-2,1,3-benzothiadiazole-based Conjugated Copolymers with Cyano Group in Vinylene Unit for Photovoltaic Applications

  • Kim, Jin-Woo;Heo, Mi-Hee;Jin, Young-Eup;Kim, Jae-Hong;Shim, Joo-Young;Song, Su-Hee;Kim, Il;Kim, Jin-Young;Suh, Hong-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.629-635
    • /
    • 2012
  • Two novel conjugated copolymers utilizing 4,7-dithien-2-yl-2,1,3-benzothiadiazole (DTBT) coupled with cyano (-CN) substituted vinylene, as the electron deficient moeity, have been synthesized and evaluated in bulk heterojunction solar cell. The electron deficient moeity was coupled with carbazole and fluorene unit by Knoevenagel condition to provide poly(bis-2,7-((Z)-1-cyano-2-(5-(7-(2-thienyl)-2,1,3-benzothiadiazol-4-yl)-2-thienyl)ethenyl)-alt-9-(1-octylnonyl)-9H-carbazol-2-yl-2-butenenitrile) (PCVCNDTBT) and poly(bis-2,7-((Z)-1-cyano-2-(5-(7-(2-thienyl)-2,1,3-benzothiadiazol-4-yl)-2-thienyl)ethenyl)-alt-9,9-dihexyl-9H-fluoren-2-yl) (PFVCNDTBT). The optical band gaps of PCVCNDTBT (1.74 eV) and PFVCNDTBT (1.80 eV) are lower than those of PCDTBT (1.88 eV) and PFVDTBT (2.13 eV), which is advantageous to provide better coverage of the solar spectrum in the longer wavelength region. The high $V_{oc}$ value of the PSC of PCVCNDTBT (~0.91 V) is attributed to its lower HOMO energy level ( 5.6 eV) as compared to PCDTBT ( 5.5 eV). Bulk heterojunction solar cells based on the blends of the polymers with [6,6]phenyl-$C_{61}$-butyric acid methyl ester ($PC_{61}BM$) gave power conversion efficiencies of 0.76% for PCVCNDTBT under AM 1.5, 100 mW/$cm^2$.

Palaeomagnetism of Cretaceous Rocks in the Ǔisǒng Area, Kyǒngsang Basin, Korea (의성지역 백악기 암석에 대한 고자기 연구)

  • Kim, In-Soo;Lee, Hyun Koo;Yun, Hyesu;Kang, Hee-Cheol
    • Economic and Environmental Geology
    • /
    • v.26 no.3
    • /
    • pp.403-420
    • /
    • 1993
  • The Cretaceous Kyongsang Basin is known to be composed of several tectonic blocks (or subbasins) with each distinct stratigraphic succession. The study area represents a major part of one of these blocks, i. e. the $\check{U}is\check{o}ng$ block. The area is charaterized by a suite of WNW-trending sinistral strike-slip faults as well as a number of ring faults. A total of 292 independently oriented core samples were drilled from 23 sites, covering virtually all the formations of the Cretaceous $Ky\check{o}ngsang$ Supergroup. Alternating field and thermal demagnetization experiments were conducted to reveal the primary magnetization. Due to the homoclinal nature of the strata in the area, it was not possible to make use of the conventional fold test It is, however, believed that the primary remanent components have been obtained from the majority of the formations, considering the similarity of the palaeomagnetic pole positions with those of contemporary strata of other blocks and the existence of antiparallel reversed remanence. It was found neither any significant difference in magnetic declination on each side of the strike-slip faults nor systematic change of magnetic declination with distance from the fault-line. This does not support such a block rotation hypothesis associated with the strike-slip faulting in the area as alleged by some authors. The samples from the outcrops on or near the fault-lines were severely overprinted by the recent magnetic fields regardless of age and lithology. Epithermal Au-Ag-Cu-Pb-Zn mineralizations are known along some fault lines in the area. It is interpreted that these two facts are closely related with fluid circulations along the fracture zones caused by fault activities. In regard to the age of the strata as deduced from the magnetostratigraphic consideration, the $Ch\check{o}mgok$ formation and the lower strata should be older than Barremian or 124 Ma. The age of volcanics of the $Yuch^{\prime}\check{o}n$ Group sampled in this study should be younger than Campanian or 83 Ma.

  • PDF

Development of Improvement Technology for Achieving Higher Throughput Limit Utilized in the Evaluation of Next Generation Dry Pumps (첨단공정용 드라이펌프 유량 측정 한계 향상기술 개발)

  • Shin, J.H.;Ko, M.K.;Cheung, W.S.;Yun, J.Y.;Lim, J.Y.;Kang, S.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.411-417
    • /
    • 2009
  • The constant volume flow meter system (the chamber volume in the 22 L class) was developed to estimate the pumping speed of the dry pump used for the industry of the next generation semiconductor and display. In order to insure the validity of the system, The base pressure and the leak rate in the enclosed system were checked, which were the $6{\times}10^{-8}\;mbar$ and $1.5{\times}10^{-6}\;mbar-L/s$, respectively. Furthermore, it is also confirmed that the value of throughput limit in this system was as much as 1 order of magnitude lower than that in a previously developed system in the 875 L class. By using this developed system, the pumping speed of the new small dry pump was measured. It is believed that the new developed system can be alternating the expensive constant pressure flow meter system in the range of $1{\times}10^{-2}\;mbar-L/s{\sim}1{\times}10^{-3}\;mbar-L/s$.

Crystal Structure of Xenon Encapsulate within Na-A Zeolite

  • Im, U Taek;Park, Man;Heo, Nam Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.1
    • /
    • pp.75-80
    • /
    • 2000
  • The positions of Xe atoms encapsulated in the molecular-dimensioned cavities of fully dehydrated Na-A have been determined. Na-A was exposed to 1050atm of xenon gas at 400 $^{\circ}C$ for seven days, followed by cooling at pressure to encapsulate Xe atoms. The resulting crystal structure of Na-A(7Xe) (a = 12.249(1) $\AA$, $R_1$ = 0.065, and $R_2$ = 0.066) were determined by single-crystal X-ray diffraction techniques in the cubic space group Pm3m at 21(1) $^{\circ}C$ and 1 atm. In the crystal structure of Na-A(7Xe), seven Xe atoms per unit cell are distributed over four crystallographically distinct positions: one Xe atom at Xe(1) lies at the center of the sodalite unit, two Xe atoms at Xe(4) are found opposite four-rings in the large cavity, and four Xe atoms, two at Xe(2) and others at Xe(3), respectively, occupy positions opposite and between eight- and six-rings in the large cavity. Relatively strong interactions of Xe atoms at Xe(2) and Xe(3) with $Na^+$ ions of four-, eight-, and six-rings are observed:Na(1)-Xe(2) = 3.09(6), Na(2)-Xe(3) = 3.11(2), and Na(3)-Xe(2) = 3.37(8) $\AA$. In each sodalite unit, one Xe atom is located at its center. In each large cavity, six Xe atoms are found, forming a distorted octahedral arrangement with four Xe atoms, at equatorial positions (each two at Xe(2) and Xe(3)) and the other two at axial positions (at Xe(4)). With various reasonable distances and angles, the existence of $(Xe)_6$ cluster is proposed (Xe(2)-Xe(3) = 4.78(6) and 4.94(7), Xe(2)-Xe(4) = 4.71(6) and 5.06(6), Xe(3)-Xe(4) = 4.11(3) and 5.32(4) $\AA$, Xe(2)-Xe(3)-Xe(2) = 93(1), Xe(3)-Xe(2)-Xe(3) = 87(1), Xe(2)-Xe(4)-Xe(2) = 91(4), Xe(2)-Xe(4)-Xe(3) = 55(2), 59(1), 61(1), and 68(1), and Xe(3)-Xe(4)-Xe(3) = 89($^{\circ}1$)). These arrangements of the encapsulated Xe atoms in the large cavity are stabilized by alternating dipoles induced on Xe(2), Xe(3), and Xe(4) by eight- and six-ring $Na^+$ ions as well as four-ring oxygens, respectively.

Observation of Ridge-Runnel and Ripples in Mongsanpo Intertidal Flat by Satellite SAR Imagery (인공위성 SAR 영상을 이용한 몽산포 조간대의 Ridge-Runnel 및 연흔 관찰)

  • Jang, So-Yeong;Han, Hyang-Sun;Lee, Hoon-Yol
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.115-122
    • /
    • 2010
  • In this study, we analyzed ridge-runnel structure and ripple marks by using Envisat ASAR, JERS-1 SAR images and in-situ data in Mongsanpo intertidal flat located in Taean-Gun, Korea. A group of light-and-dark lines parallel to the shoreline, alternating 3-5 times, were observed in the intertidal flat in Envisat ASAR images. The patterns are related to ridge-runnel structure in the intertidal flat exposed to air. Well-drained runnels, typically with ripple marks, showed strong backscattering while runnels submerged by surface water or ridges, typically smooth with no ripple, have weak backscattering coefficients in Envisat ASAR images. In JERS-1 SAR images, however, the backscattering was very low on the entire intertidal flat and no ridge-runnel structure could be observed. The wavelengths of ripple marks measured from in-situ observations have ranges from 4 to 10 cm that satisfies the Bragg scattering condition of the 1st-order in Envisat ASAR images operating in C-band, but not in JERS-1 SAR that used L-band. Through this study using SAR images, we could successfully analyze the sedimentary conditions of intertidal flats with ridge-runnel and ripple marks which are not easily observed by optical sensors. It is expected that the results of this study with SAR images will contribute to the sedimentary research over intertidal flats.

Kr Atoms and Their Chlustering in Zeolite A

  • Im, U Taek;Jang, Jang Hwan;Jeong, Gi Jin;Heo, Nam Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.9
    • /
    • pp.1023-1029
    • /
    • 2001
  • The positions of Kr atoms encapsulated in the molecular-dimensioned cavities of fully dehydrated zeolite A of unit-cell composition Cs3Na8HSi12Al12O48 (Cs3-A) have been determined. Cs3-A was exposed to 1025 atm of krypton gas at 400 $^{\circ}C$ for four days, followed by cooling at pressure to encapsulate Kr atoms. The resulting crystal structure of Cs3-A(6Kr) (a = $12.247(2)\AA$, R1 = 0.078, and R2 = 0.085) has been determined by single-crystal X-ray diffraction techniques in the cubic space group Pm3m at $21(1)^{\circ}C$ and 1 atm. In the crystal structure of Cs3-A(6Kr), six Kr atoms per unit cell are distributed over three crystallographically distinct positions: each unit cell contains one Kr atom at Kr(1) on a threefold axis in the sodalite unit, three at Kr(2) opposite four-rings in the large cavity, and two at Kr(3) on threefold axes in the large cavity. Relatively strong interactions of Kr atoms at Kr(1) and Kr(3) with Na+ ions of six-rings are observed: Na-Kr(1) = 3.6(1) $\AA$ and Na-Kr(3) = $3.08(5)\AA.$ In each sodalite unit, one Kr atom at Kr(1) was displaced $0.74\AA$ from the center of the sodalite unit toward a Na+ ion, where it can be polarized by the electrostatic field of the zeolite, avoiding the center of the sodalite unit which by symmetry has no electrostatic field. In each large cavity, five Kr atoms were found, forming a trigonal-bipyramid arrangement with three Kr(2) atoms at equatorial positions and two Kr(3) atoms at axial positions. With various reasonable distances and angles, the existence of Kr5 cluster was proposed (Kr(2)-Kr(3) = $4.78(6)\AA$ and Kr(2)-Kr(2) = $5.94(7)\AA$, Kr(2)-Kr(3)-Kr(2) = 76.9(3), Kr(3)-Kr(2)-Kr(3) = 88(1), and Kr(2)-Kr(2)-Kr(2) = $60^{\circ}).$ These arrangements of the encapsulated Kr atoms in the large cavity are stabilized by alternating dipoles induced on Kr(2) by four-ring oxygens and Kr(3) by six-ring Na+ ions, respectively.