• 제목/요약/키워드: alternating current

검색결과 392건 처리시간 0.025초

DyCoO3 세라믹스의 교류전도특성 (Alternating-Current Electrical Conduction Properties of DyCoO3 Ceramics)

  • 정우환
    • 한국재료학회지
    • /
    • 제20권3호
    • /
    • pp.161-166
    • /
    • 2010
  • The ac, dc conductivity and dielectric properties of $DyCoO_3$ were reported in the temperature range of 77 - 300K and in the frequency range of 20 Hz - 100 kHz. It was observed that at low temperature, ac conductivity is much higher than dc conductivity and the hopping carrier between localized states near the Fermi level was the dominant loss mechanism. A comparison of the measured ac conductivity $\sigma(\omega)$ was made with some of the models of hopping conductivity of the proposed earlier in the literature. It was observed that in $DyCoO_3$ the measured ac conductivity, over the entire frequency and temperature region, can be explained reasonably well by assuming two contributions $\sigma_1(\omega)$ and $\sigma_2(\omega)$ to the measured $\sigma(\omega)$. The first, $\sigma_1(\omega)$, which dominates at low temperature, may be due to impurity conduction in a small polaron; the second, $\sigma_2(\omega)$, which dominates at higher temperatures, depending on the frequency of measurements, may be due to the hopping of a small polaron and is reasonable for the dielectric relaxation peak.

Ga-doped ZnO 투명전극을 적용한 교류무기전계발광소자 특성 연구 (Top-emission Electroluminescent Devices based on Ga-doped ZnO Electrodes)

  • 이운호;장원태;김종수;이상남
    • 반도체디스플레이기술학회지
    • /
    • 제16권2호
    • /
    • pp.44-48
    • /
    • 2017
  • We explain optical and electrical properties of top and bottom-emission structured alternating-current powder electroluminescent devices (ACPELDs) with Ga-doped ZnO(GZO) transparent electrode. The top-emission ACPELDs were layered as the metal electrode/dielectric layer/emission layer/top transparent electrode and the bottom-emission ACPELDs were structured as the bottom transparent electrode/emission layer/dielectric layer/metal electrode. The yellow-emitting ZnS:Mn, Cu phosphor and the barium titanate dielectric layers were layered through the screen printing method. The GZO transparent electrode was deposited by the sputtering, its sheet resistivity is $275{\Omega}/{\Box}$. The transparency at the yellow EL peak was 98 % for GZO. Regardless of EL structures, EL spectra of ACPELDs were exponentially increased with increasing voltages and they were linearly increased with increasing frequencies. It suggests that the EL mechanism was attributed to the impact ionization by charges injected from the interface between emitting phosphor layer and the transparent electrode. The top-emission structure obtained higher EL intensity than the bottom-structure. In addition, charge densities for sinusoidal applied voltages were measured through Sawyer-Tower method.

  • PDF

Electromagnetic Electron-Cyclotron Wave for Ring Distribution with Alternating Current (AC) Electric Field in Saturn Magnetosphere

  • Haridas, Annex Edappattu;Kanwar, Shefali;Pandey, Rama Shankar
    • Journal of Astronomy and Space Sciences
    • /
    • 제39권2호
    • /
    • pp.35-42
    • /
    • 2022
  • During their respective missions, the spacecraft Voyager and Cassini measured several Saturn magnetosphere parameters at different radial distances. As a result of information gathered throughout the journey, Voyager 1 discovered hot and cold electron distribution components, number density, and energy in the 6-18 Rs range. Observations made by Voyager of intensity fluctuations in the 20-30 keV range show electrons are situated in the resonance spectrum's high energy tail. Plasma waves in the magnetosphere can be used to locate Saturn's inner magnetosphere's plasma clusters, which are controlled by Saturn's spin. Electromagnetic electron cyclotron (EMEC) wave ring distribution function has been investigated. Kinetic and linear approaches have been used to study electromagnetic cyclotron (EMEC) wave propagation. EMEC waves' stability can be assessed by analyzing the dispersion relation's effect on the ring distribution function. The primary goal of this study is to determine the impact of the magnetosphere parameters which is observed by Cassini. The magnetosphere of Saturn has also been observed. When the plasma parameters are increased as the distribution index, the growth/damping rate increases until the magnetic field model affects the magnetic field at equator, as can be seen in the graphs. We discuss the outputs of our model in the context of measurements made in situ by the Cassini spacecraft.

와류기인진동을 이용한 신재생에너지 발전에서 유체력 추정연구 (Estimation of Fluid Force for Renewable Energy Generation Using Vortex-induced Vibrations)

  • 박홍래
    • 신재생에너지
    • /
    • 제19권2호
    • /
    • pp.23-30
    • /
    • 2023
  • Vortex-induced vibrations are a type of flow-induced vibrations caused by alternating lift forces. With increasing demand for renewable energy, the application of vortex-induced vibrations to renewable energy has been widely studied. Vortex-induced vibrations for aquatic clean energy (VIVACE) converter is a renewable energy device that generates electricity from rivers or oceans using vortex-induced vibrations. To increase the design life and power harnessing capacity of the VIVACE converter, the estimation of fluid forces due to vortex-induced vibrations is essential. Herein, vortex-induced vibrations were experimentally tested, and their amplitude and frequency response were measured. The amplitude results showed four different branches: initial branch, upper branch, lower branch, and desynchronization range. According to the fluid force coefficient results, the maximum lift coefficient occurred at the upper branch. Additionally, a mathematical model is proposed to estimate fluid forces due to vortex-induced vibrations without using measurement devices. This mathematical model enables the estimation of fluid force coefficients and phase lag using amplitude and frequency response of vortex-induced vibrations.

Comparison of event tree/fault tree and convolution approaches in calculating station blackout risk in a nuclear power plant

  • Man Cheol Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.141-146
    • /
    • 2024
  • Station blackout (SBO) risk is one of the most significant contributors to nuclear power plant risk. In this paper, the sequence probability formulas derived by the convolution approach are compared with those derived by the conventional event tree/fault tree (ET/FT) approach for the SBO situation in which emergency diesel generators fail to start. The comparison identifies what makes the ET/FT approach more conservative and raises the issue regarding the mission time of a turbine-driven auxiliary feedwater pump (TDP), which suggests a possible modeling improvement in the ET/FT approach. Monte Carlo simulations with up-to-date component reliability data validate the convolution approach. The sequence probability of an alternative alternating current diesel generator (AAC DG) failing to start and the TDP failing to operate owing to battery depletion contributes most to the SBO risk. The probability overestimation of the scenario in which the AAC DG fails to run and the TDP fails to operate owing to battery depletion contributes most to the SBO risk overestimation determined by the ET/FT approach. The modification of the TDP mission time renders the sequence probabilities determined by the ET/FT approach more consistent with those determined by the convolution approach.

Pt Catalysts Prepared via Top-down Electrochemical Approach: Synthesis Methodology and Support Effects

  • Alexandra Kuriganova;Igor Leontyev;Nikolay Leontyev;Nina Smirnova
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권3호
    • /
    • pp.345-352
    • /
    • 2024
  • The synthesis of Pt nanoparticles and catalytically active materials using the electrochemical top-down approach involves dispersing Pt electrodes in an electrolyte solution containing alkali metal cations and support material powder using an alternating pulsed current. Platinum is dispersed to form particles with a predominant crystallographic orientation of Pt(100) and a particle size of approximately 7.6±1.0 nm. The dispersed platinum particles have an insignificant content of PtOx phase (0.25±0.03 wt.%). The average formation rate was 9.7±0.5 mg cm-2 h-1. The nature of the support (carbon material, metal oxide, carbon-metal oxide hybrid) had almost no effect on the formation rate of the Pt nanoparticles as well as their crystallographic properties. Depending on the nature of the support material, Pt-containing catalytic materials obtained by the electrochemical top-down approach showed good functional performance in fuel cell technologies (Pt/C), catalytic oxidation of CO (Pt/Al2O3) and electrochemical oxidation of methanol (Pt/TiO2-C) and ethanol (Pt/SnO2-C).

고출력 LED 모듈 역률 개선 방법 연구 (A Study on Methodology to Improve the Power Factor of the High Power LED Module)

  • 노영환
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.335-340
    • /
    • 2014
  • 친환경 및 에너지 효율에 대한 관심이 증대되고 있는 가운데 LED(Light Emitting Diode)는 제어방식이 정 전류구동과 SMPS(Switching Mode Power Supply)방식으로 구동하므로 소형화 및 경량화를 이룰 수 있고 전력 소모가 적으며 효율이 높아 광원 및 조명장치에 활용하는데 유용하다. LED 생산업체는 고출력 LED 모듈의 칩 설계 원천기술의 확보가 필요하고, LED 를 조명으로 적용시키기 위해 전력손실을 줄일 수 있는 고출력 LED 모듈 개발을 위한 구동회로 설계와 역률 개선의 방안 연구가 필요하다. 산업현장에서 교류(AC) 직결 LED 구동소자인 HV9910를 일반적으로 사용하고 있다. 본 논문에서 HV9910에 PFC와 Noise Filter를 추가한 구동회로의 역률 및 효율에 대한 개선방법을 시뮬레이션을 통해 검증하는데 있다.

Improvement of Dynamic Behavior of Shunt Active Power Filter Using Fuzzy Instantaneous Power Theory

  • Eskandarian, Nasser;Beromi, Yousef Alinejad;Farhangi, Shahrokh
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1303-1313
    • /
    • 2014
  • Dynamic behavior of the harmonic detection part of an active power filter (APF) has an essential role in filter compensation performances during transient conditions. Instantaneous power (p-q) theory is extensively used to design harmonic detectors for active filters. Large overshoot of p-q theory method deteriorates filter response at a large and rapid load change. In this study the harmonic estimation of an APF during transient conditions for balanced three-phase nonlinear loads is conducted. A novel fuzzy instantaneous power (FIP) theory is proposed to improve conventional p-q theory dynamic performances during transient conditions to adapt automatically to any random and rapid nonlinear load change. Adding fuzzy rules in p-q theory improves the decomposition of the alternating current components of active and reactive power signals and develops correct reference during rapid and random current variation. Modifying p-q theory internal high-pass filter performance using fuzzy rules without any drawback is a prospect. In the simulated system using MATLAB/SIMULINK, the shunt active filter is connected to a rapidly time-varying nonlinear load. The harmonic detection parts of the shunt active filter are developed for FIP theory-based and p-q theory-based algorithms. The harmonic detector hardware is also developed using the TMS320F28335 digital signal processor and connected to a laboratory nonlinear load. The software is developed for FIP theory-based and p-q theory-based algorithms. The simulation and experimental tests results verify the ability of the new technique in harmonic detection of rapid changing nonlinear loads.

전자기 진동을 이용한 Al-Si 합금의 조직 제어에 관한 연구 (A Study on the Structural Controlling of Al-Si Alloy by Using Electromagnetic Vibration)

  • 최정평;김기배;남태운;윤의박
    • 한국주조공학회지
    • /
    • 제26권5호
    • /
    • pp.205-210
    • /
    • 2006
  • 여러 전자기 재료 프로세싱 연구 중에서 연구 되어지지 않았던 Al-Si 합금의 조직제어를 직류 자기장과 교류 전류장을 사용하여 시도 하였다. 본 연구의 목적은 Al-Si 합금에서의 새로운 거시, 미시 조직제어를 하기 위해 사용된 전자기 진동의 영향을 조사하는 것이다. 전자기 진동이 초정 알루미늄의 형상 변화를 위해 낮은 진동수 (>60Hz)로 주어질 경우, 수지상의 형상이 구상화 형상으로 변해갔다. 전자기 진동이 공정 실리콘 형상 변화를 위해 주어졌을 경우, 높은 진동수 (>500Hz)에서 조대한 판상 조직이던 실리콘이 미세한 섬유상 조직으로 변화하고, 기계적 성질도 우수해졌다.

평면형 다중접합 열전변환기의 특성 (Characteristics of a Planar Multijunction Thermal Converter)

  • 조현덕;김진섭;이종현;이정희;박세일;권성원
    • 대한전자공학회논문지SD
    • /
    • 제38권10호
    • /
    • pp.699-705
    • /
    • 2001
  • 교류의 실용 표준기로 사용하기 위해 TC 1에서 TC 6까지 6개의 평면형 열전변환기를 설계 및 제작하였다. 공기중 및 진공중의 전압 감응도는 TC 6의 경우 열손실이 가장 작아 약 4.03 mV/mW 및 약 6.38 mV/mW의 가장 큰 값을 나타내었다. 열시정수는 히터의 열관성이 가장 부족한 TC 6을 측정하여 약 8 ms를 얻었다. FRDC(fast reversed DC) 방법에 의한 교류-직류 전압 및 전류 변환오차는 40 Hz∼10 ㎑ 주파수 범위에서 1 V 및 5 mA의 정현파 실효전압 및 실효전류를 인가하였을 때 약 ±0.41∼±0.85 ppm 및 약 ±0.15∼±1.16 ppm으로서 실용표준으로 사용하기에 적합하였다.

  • PDF