• Title/Summary/Keyword: alternating

Search Result 1,373, Processing Time 0.033 seconds

Protection Techniques Against Electric Shock in Low Voltage DC Grounding Systems Depending on the Analysis of Earth Fault Current Paths (저압직류 접지시스템의 지락경로 흐름 분석에 따른 감전 보호기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Choi, Myeong-Il;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.232-238
    • /
    • 2016
  • This paper presents protection techniques against electric shock in low voltage DC(direct current) grounding systems depending on the analysis of earth fault current paths. Firstly, the comparison between alternating current and direct current on human was conducted, and current threshold values for each current path and for long duration were analyzed. Secondly, the analyses of the earth fault current flows were performed depending on the grounding types and earth fault conditions. Lastly, based on these analyses, adequate protection measures of electric shock depending on low voltage DC grounding types were provided.

Electrowetting of a droplet under an AC Electric Fields (교류전압 하에서의 액적의 전기습윤현상)

  • Hong, Jin-Seok;Ko, Sung-Hee;Kang, Kwan-Hyung;Kang, In-Seok
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.175-176
    • /
    • 2006
  • Electrowetting is prevailing for its various applicability on lap-on-a-chip, and MEMS devices, such as a pump, lens, micro-actuator in the micro-TAS technology. In the usual electrowetting, an AC power is preferred to DC practically. The AC electric field delays the contact angle-saturation, decreases the hysterisis, and is more stable in the view point of dielectric strength. But researches for AC electric field on electrowetting have not been reported very much yet. The different effect of AC on the electrowetting system, especially the effect of a frequency needs to be understood more concretely. In this work, the usual system for electrowetting, water droplet on the dielectric coated electrode (EWOD) is analyzed. Experimental study on the response of contact angles on input frequencies is performed. The simple circuit-model for EWOD system is considered to explain the experimental results. For more concrete understanding, the system is analyzed numerically, where simple AC-conduction model is used. Wetting tensions are analyzed under various input frequency to excavate the experimental results for the responses of the system on input frequencies.

  • PDF

A Comparison between EFIU and HEIU Schemes in ADI-FDTD Simulations (ADI-FDTD 해석에서의 EFIU와 HFIU 계산 방법 비교 연구)

  • Ju Sae-Hoon;Lee Kyung-Hoon;Hwang In-Ho;Kim Hyeong-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.8-16
    • /
    • 2006
  • In this paper, updating schemes for the alternating-direction implicit finite-difference time-domain method(ADI-FDTD) are studied, which method has the potential to considerably reduce the number of time iterations especially in case where the fine spatial lattice relative to the wavelength is used to resolve fine geometrical features. In numerical simulations for microwave structure using ADI-FDTD, time marching scheme comprises of two sub-iterations. Two different updating equation sets for ADI-FDTD simulations are presented. In order to discuss the characteristics of those schemes especially in view of applying boundary conditions, we solved two complementary 2-D problems.

Comparison of the Effect in ROM Increase and Pain Reduction on Stretching During Ultrasound Treatment in Patients With Frozen Shoulder (동결견 환자의 초음파치료 시 신장여부에 따른 관절가동범위 회복과 통증감소 효과 비교)

  • Yang, Hoe-Song
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.129-137
    • /
    • 2003
  • A single subject experimental design (alternating treatment design) was used to compare the effects of only ultrasound and ultrasound combined with stretching of the joint capsule on the ROM increase and pain reduction in patients with frozen shoulder. Two subjects were included in each group. In the only ultrasound treatment sessions, ultrasound was applied at the pain point of the shoulder joint in supine position. In the ultrasound combined with stretching treatment sessions, ultrasound was applied at the pain point of the shoulder joint positioned in external rotation and abduction in sitting position. Only ultrasound treatment and ultrasound combined with stretching treatment were alternately performed on each patient. Pain and disability was measured by shoulder pain and disability index (SPADI), and range of motion (ROM) was measured by scratch test. The results of this study showed that ultrasound combined with stretching treatment were more effective than only ultrasound treatment in ROM increase and pain reduction. However, disability score was not significantly different.

  • PDF

Structural Integrity Evaluation for Interference-fit Flywheels in Reactor Coolant Pumps of Nuclear Power Plants

  • Park June-soo;Song Ha-cheol;Yoon Ki-seok;Choi Taek-sang;Park Jai-hak
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.11
    • /
    • pp.1988-1997
    • /
    • 2005
  • This study is concerned with structural integrity evaluations for the interference-fit flywheels in reactor coolant pumps (RCPs) of nuclear power plants. Stresses in the flywheel due to the shrinkage loads and centrifugal loads at the RCP normal operation speed, design overspeed and joint-release speed are obtained using the finite element method (FEM), where release of the deformation-controlled stresses as a result of structural interactions during rotation is considered. Fracture mechanics evaluations for a series of cracks assumed to exist in the flywheel are conducted, considering ductile (fatigue) and non-ductile fracture, and stress intensity factors are obtained for the cracks using the finite element alternating method (FEAM). From analysis results, it is found that fatigue crack growth rates calculated are negligible for smaller cracks. Meanwhile, the material resistance to non-ductile fracture in terms of the critical stress intensity factor (K$_{IC}$) and the nil-ductility transition reference temperature (RT$_{NDT}$) are governing factors for larger cracks.

Effect of 3D Printed Spiral Antenna Design on Inductive Coupling Wireless Power Transmission System (3차원 프린팅을 이용한 무선전력전송의 안테나 설계 특성 규명)

  • Kim, Ji-Sung;Park, Min-Kyu;Lee, Ho;Kim, Chiyen
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.8
    • /
    • pp.73-80
    • /
    • 2020
  • The 3D printing of electronics has been a major application topics in additive manufacturing technology for a decade. In this paper, wireless power transfer (WPT) technology for 3D electronics is studied to supply electric power to its inner circuit. The principle of WPT is that electric power is induced at the recipient antenna coil under an alternating magnetic field. Importantly, the efficiency of WPT does rely on the design of the antenna coil shape. In 3D printed electronics, a flat antenna that can be placed on the printed plane within a layer of a 3D printed part is used, but provided a different antenna response compared to that of a conventional PCB antenna for NFC. This paper investigates the WPT response characteristics of a WPT antenna for 3D printed electronics associated with changes in its design elements. The effects of changing the antenna curvature and the gap between the wires were analyzed through experimental tests.

Fluctuations of Coastal Water Temperatures Along Korean and Japanese Coasts in the East Sea

  • KANG Yong-Q.;CHOI Seong-Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.6
    • /
    • pp.351-360
    • /
    • 1988
  • Based on historic data of monthly means of sea surface temperatures (SST) for 24 years $(1921\~1944) $ at 23 Korean and Japanese coastal stations in the East Sea (the Japan Sea), we analyzed spatio-temporal characteristics of coastal SST and SST anomalies. The means of SST at Korean coast are higher than those at Japanese coast of the same latitudes, and the annual range of SST at Korean coast are larger than those at Japanese coast. Empirical orthogonal function analysis shows that almost all $(96\%)$ of the SST fluctuations are described by simultaneous seasonal variations. The flurtuations of SST anomalies are small in the Korea Strait and large at the boundaries between the warm and told currents in the basin. The fluctuations of SST anomalies along Korean coast are correlated each other The same is true for SST anomalies along Japanese coast. However, there is only weak correlation between the SST anomalies at Korean coast and those at Japanese coast. Empirical orthogonal function analysis shows that $27\%$ of the coastal SST anomalies in the East Sea are described by simultaneous fluctuations, and $12\%$ of them are described by alternating fluctuations between Korean and Japanese coasts.

  • PDF

Electrical Quadruple Layer under the AC Electric Field

  • Suh, Yong-Kweon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.167-176
    • /
    • 2006
  • In this paper we show that solutions of the nonlinear Nernst-Planck equation possesses the quadruple-layer structure near the interface when the electrolyte receives a high frequency forcing such as a high-frequency alternating current. Very near to the interface wall, the well-known, classical Stern layer exists. Near to the Stern layer we have the secondly thin layer (to be called inner layer in this paper) where the ion concentrations behave under the same frequency as the external forcing. However, in this layer, the positive and negative ion concentrations develop with the time phase 180-degree different from each other. Next to this second layer, we have the third layer (called middle layer) in which two ion concentrations change with the time period double the forcing, and both concentrations behave in the same time phase. In the outermost layer, i.e. the forth layer, (called outer layer) the ion concentrations show the same-phase development as the third one but decaying very slowly in time. Our assertion is mostly based on the 1-D numerical simulation for the Nernst-Planck equation under a high frequency AC field assuming that the quadruple layer is very thin compared with the length scale representative of the bulk region.

  • PDF

A Study on the Characteristics of Cutting for A16061-T6 (A16061-T6재의 절삭가공 특성에 관한 연구)

  • 강상도;채왕석;김경우;김우순;김동현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.202-208
    • /
    • 2003
  • This study carried out a cutting experiment on Duralumin A16061-76, which is light but strong and highly anticorrosive, so recently popular as a lightweight material, by changing cutting conditions and alternating 4 insert tips, and examined the effect of each insert tip on cutting force at certain cutting conditions, the measurements of the coarseness of processed surfaces roughness, and the chip workability. The 1311owing conclusions were drawn from the results. Cutting force for cutting tool is when insert tips were alternated at each cutting condition, the cutting force of cutting tools was highest then CBN tools were use(1 next by Ceramic tools, Cermet tools, and WC tools. Therefore, WC tools are considered most suitable for cutting Duralumin A16061-T6. Surface roughness as for the coarseness of surfaces according to insert tips applied to Duralumin A16061-T6 under the cutting condition of depth of cut below 1mm, feed rate below 0.24mm/rev and cutting speed over 100m/min the coarseness of material surface roghness appeared to be finest when WC tools were used, next by Ceramic tools, Cermet tools, and CBN tools.

  • PDF

Change in Magnetic Flux in the Air Due to Load (하중에 의한 공기중 자속의 변화)

  • Lee, Jeong-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • In order to determine the effective way of measuring the Mode I stress intensity factor($K_1$) by means of the alternating current potential drop(ACPD) technique for a material containing a two-dimensional surface crack, the change in magnetic flux in the air due to load was studied theoretically and experimentally. The magnetic flux in the air between crack surfaces is uniform and is not changed by increasing the load in the specimen and experimental results are the same as those obtained from theoretical analysis. Therefore, the change in potential drop due to load in the measuring system which was designed to induce a large amount of electro-motive force was caused by the change in internal inductance of material and the change in the mutual inductance concerned with internal inductance of material.