Identification on Fatigue Failure of Impeller at Single Stage Feedwater Pumps During Commissioning Operation (단단 주 급수 펌프 임펠러에서 시운전 중 발생한 피로 절손에 관한 규명 연구)

  • Kim, Yeon-Whan;Kim, Kye-Yean;Bae, Chun-Hee;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.937-942
    • /
    • 2008
  • This paper presents a case history on failures of impeller and shaft due to pressure pulsation at single stage feed water pumps in 700 MW nuclear power plant during commissioning operation. The pumps had been service and had run for approximately $40{\sim}50$ hours. For the most part, the failures of impeller occurred with the presence of a number of fatigue cracks. All cracks were associated with the deleterious surface layer of impeller by visual and metallurgical examination. On-site testing and analytical approach was performed on the systems to diagnose the problem and develop a solution to reduce the effect of exciting sources. A major concern at high-energy centrifugal pump is the pressure pulsation created from trailing edge of the Impeller blade, flow separation and recirculation at centrifugal pumps of partial load. Pressure pulsation due to the interaction generating between impeller and casing coincided with natural frequencies of the impeller and shaft system during 1ow load operation. It was identified that dynamic stress exceeding the fatigue strength of the material at the thin shroud section due to the hydraulic instability at running condition below BEP.

A Bibliography study on the cause & syndrome of diffuse fluid-retention syndrome (일음(溢飮)의 원인(原因)과 증상(症狀)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Lou, Dong-Su
    • The Journal of Internal Korean Medicine
    • /
    • v.11 no.2
    • /
    • pp.128-136
    • /
    • 1990
  • I Studied some important medical literatures inorder to examine the cause & syndrome of diffuse fluid-retention syndrome and found out some facts as follows ; 1. cause of diffuse fluid-retention syndrome is Hwang Je Nae Kyong(黃帝內經) and so forth six kinds of medicine books are reffered sudden thirst of intestin and stomark cause of disease Golden chamber(金?要略) and so forth fifteen kinds of medicine books are reffered fluid water promote obscesses atributide at four extrenities and unable hidrosis cause of disease Elementary cause for medicine(醫學入門) and so forth kinds of book medicine books are reffered water in four extrenities cause of disease. The classified Medical Records of Famous physicians(名醫類安) reffered rest at wetness earthly cause of disease. 2. syndrome of diffuse fluid-retention syndrome is Golden chamber and so forth nineteen kinds of medicine books are reffered compression and pain of body syndrome of disease. Hwang Je Nae Kyong(黃帝內經) and so forth seven kinds of medicine books are reffered pulse ; the liver-pulse is soft and powder syndrome of disease. The classified Medical Records of Famous physicians(名醫類安) and so forth two kinds at medicine book are reffered general syndrome of disease. Today is reffered edema of four extremites syndrome of disease. The cause & syndrome of diffuse fluid-retention syndrome obtained was as follows ; cause of diffuse fluid-retention syndrome is fluid water promote abscess attributide at four extremities and unable hidrosis and compression and pain body is main syndrome and hyperhidrosis, vertigo, edema of four extremities alternating episodes of chills and fever can guan pulse is sunken and slippery and both chi wiry are represented syndrome of diffuse fluid-retention syndrome.

  • PDF

Effect of Ambient Temperature on the AC Electrical Treeing Phenomena in an Epoxy/Layered Silicate Nanocomposite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.221-224
    • /
    • 2013
  • Effects of ambient temperature on the ac electrical treeing and breakdown behaviors in an epoxy/layered silicate (1 wt%) were carried out in needle-plate electrode geometry. A layered silicate was exfoliated in an epoxy base resin,, using our ac electric field apparatus. To measure the treeing initiation and propagation, and the breakdown rate, constant alternating current (ac) of 10 kV (60 Hz) was applied to the specimen in a needle-plate electrode arrangement, at $30^{\circ}C$, $90^{\circ}C$ or $130^{\circ}C$ of insulating oil bath. At $30^{\circ}C$, the treeing initiation time and the breakdown time in the epoxy/layered silicate (1 wt%) system were 1.4 times higher than those of the neat epoxy resin. At $90^{\circ}C$ (lower than Tg), electrical treeing was initiated in 55 min, and propagated until 1,390 min at the speed of $0.35{\times}10^{-3}mm/min$, which was 4.4 times higher than that at $30^{\circ}C$; however, there was almost no further treeing propagation after 1,390 min. At $130^{\circ}C$ (higher than Tg), electrical treeing was initiated in 44 min, and propagated until 2,000 min at the speed of $0.96{\times}10^{-3}mm/min$. Typical branch type electrical treeing was obtained from the neat epoxy and epoxy/layered silicate at $30^{\circ}C$, while bush type treeing was observed out from the needle tip at $90^{\circ}C$ and $130^{\circ}C$.

Comparison of Movement of Rapid Alternating Movements of Hands in Idiopathic Parkinson's Disease Patients and Normal Subjects using Angular Velocity Measurement System (각속도 측정시스템을 이용한 특발성 파킨슨병 환자와 정상인의 빠른 손놀림 동작의 비교)

  • Kim, Ji-Won;Kwon, Yu-Ri;Eom, Gwang-Moon;Jun, Jae-Hoon;Yi, Jeong-Han;Lee, Jeong-Whan;Kwon, Do-Young;Koh, Seong-Beom;Park, Byung-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.674-677
    • /
    • 2010
  • The purpose of this study was to analyze bradykinesia of forearm movement in patients with Parkinson's disease (PD) as compared to those of normal subjects. A gyrosensor was selected for the measurement of forearm movement, because it can provide angular velocity signal which is free from the gravitational artifact and also because it can be conveniently used during clinical test of bradykinesia. Forty PD patients (age: $65.7\pm11.1$ yrs, H&Y stage:$2.3\pm0.5$), 14 age-matched elderly subjects ($65\pm3.9$ yrs) and 17 healthy young subjects ($24\pm2.1$ yrs) participated in this study. Angular velocity during forearm movement of pronation/supination was measured in both arms. Suggested quantitative measures of bradykinesia were root-mean-squared (RMS) angular velocity, RMS angle, peak power and total power which were derived from the angular velocity. ANOVA showed that all measures were significantly different among three groups (p<0.001). Subsequent post-hoc test revealed that all measures in PD patients were significantly smaller than in healthy elderly and healthy young subjects (p<0.05). This results suggest that PD patients can be differentiated from normal subjects using suggested measures.

Analysis of Cross-Phase Modulation using a periodic signal in a Single-Mode Fiber (주기적 신호를 이용한 단일모드 광섬유의 상호 위상변조 해석)

  • Lee, Jong-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2963-2967
    • /
    • 2015
  • The pump-probe scheme is used to analyze the cross-phase modulation penalty of a single-mode fiber in a WDM system. The pump signal is assumed to be a periodically modulated input like a raised sinusoidal. The periodic signal models an alternating bit sequence, and leads to an analytical expression of CPM penalty which is measured by EOP. The derived expression shows good agreement with numerical results in conventional single-mode fiber systems over a wide range of channel spacing, ${\Delta}f$. In dispersion-shifted fiber systems when ${\Delta}f$ < 100GHz, the derived expression shows increased discrepancy with the numerical results due to the increased FWM. This is not a surprising because the pump-probe scheme is used to analyze system performance degradation due to CPM.

Long-Lasting and Highly Efficient TRIAC Dimming LED Driver with a Variable Switched Capacitor

  • Lee, Eun-Soo;Choi, Bo-Hwan;Nguyen, Duy Tan;Choi, Byeung-Guk;Rim, Chun-Taek
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1268-1276
    • /
    • 2016
  • A triode for alternating current (TRIAC) dimming light emitting diode (LED) driver, which adopts a variable switched capacitor for LED dimming and LED power regulation, is proposed in this paper. The proposed LED driver is power efficient, reliable, and long lasting because of the TRIAC switch that serves as its main switch. Similar to previous TRIAC dimmers for lamps, turn-on timing of a TRIAC switch can be controlled by a volume resistor, which modulates the equivalent capacitance of the proposed variable switched capacitor. Thus, LED power regulation against source voltage variation and LED dimming control can be achieved by the proposed LED driver while meeting the global standards for power factor (PF) and total harmonic distortion (THD). The long life and high power efficiency of the proposed LED driver make it appropriate for industrial lighting applications, such as those for streets, factories, parking garages, and emergency stairs. The detailed analysis of the proposed LED driver and its design procedure are presented in this paper. A prototype of 80 W was fabricated and verified by experiments, which showed that the efficiency, PF, and THD at Vs = 220 V are 93.8%, 0.95, and 22.5%, respectively; 65 W of LED dimming control was achieved with the volume resistor, and the LED power variation was well mitigated below 3.75% for 190 V < Vs < 250 V.

Effect of an Electric Field on the AC Electrical Treeing in Various Epoxy/Reactive Diluent Systems

  • Bang, Jeong-Hwan;Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.308-311
    • /
    • 2013
  • The effect of an electric field on the ac electrical treeing in various epoxy/reactive diluent systems was studied in a needle-plate electrode geometry. Diglycidyl ether of bisphenol A (DGEBA) type epoxy was used as a base resin, and 1,4-butanediol diglycidyl ether (BDGE) or polyglycol (PG) as a reactive diluent was introduced to the DGEBA system, in order to decrease the viscosity of the DGEBA epoxy system. BDGE was acted as a chain extender, and PG acted as a flexibilizer, after the curing reaction. To measure the treeing initiation time and the propagation rate, three constant alternating currents (ac) of 10, 13 and 15 kV/4.2 mm (60 Hz) were applied to the specimen, in a needle-plate electrode arrangement, at $30^{\circ}C$ of insulating oil bath. When 10 kV/4.2 mm (60 Hz) was applied, the treeing initiation time and the propagation rate in the DGEBA system were 356 min and $1.10{\times}10^{-3}$ mm/min, respectively, those in the DGEBA/BDGE system were 150 min and $1.14{\times}10^{-3}$ mm/min, respectively. Those in the DGEBA/PG system were 469 min and $1.05{\times}10^{-3}$ mm/min, respectively. As 15 kV/4.2 mm (60 Hz) was applied, the propagation rate in the DGEBA system was $5.41{\times}10^{-3}$ mm/min, and that in the DGEBA/PG system was $1.42{\times}10^{-3}$ mm/min. These values meant that PG could be used as a reactive diluent in the DGEBA system, without the deterioration of the insulation breakdown property.

Testicular Epidermoid Cyst on Diffusion-Weighted MR Imaging and ADC Map : A Case Report (확산강조영상과 현상확산계수(ADC) 영상을 통한 고환 표피 낭종의 진단: 증례 보고)

  • Kim, Mi-Sun;Kim, Kyung-Ah;Chang, Sun-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.154-159
    • /
    • 2011
  • Testicular epidermoid cyst is a rare benign tumor, accounting for 1-2% of all testicular tumors. It can be cured by organ preserving surgery, so accurate preoperative diagnosis is very important for preventing unneccessary and extensive orchiectomy. We experienced a case of an 18-year-old man who presented with a painless lump in his right testis. The testicular mass showed an onion ring sign on ultrasonography. Computed tomography images showed the mass as a low attenuating lesion with curvilinear calcification. On Magnetic resonance imaging (MRI), the mass appeared as high signal intensity with internal alternating low signal intensity patterns on T2-weighted images. The mass was displayed as having homogeneous high signal intensity on diffusion magnetic resonance imaging and showed lower apparent diffusion coefficient values than normal testis parenchyma, similar to intracranial epidermoid cysts. Testicular MRI with DWI and ADC map can help to more accurately diagnose testicular epidermoid cyst.

Inductive Micro Thin Film Sensor for Metallic Surface Crack Detection (금속 표면결함 검출용 자기유도 마이크로 박막 센서)

  • Kim, Ki-Hyeon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.395-400
    • /
    • 2008
  • Alternating magnetic field was used for detection of surface flaws on nonmagnetic and magnetic metallic specimens. The nondestructive sensor probe was composed of the planar coil with inductive magnetic thin film yoke as a sensing component and a single straight typed exciting coil. The planar inductive coil sensor with magnetic yoke was fabricated by sputtering, electroplating, dry etching and photolithography process. The alternative currents with the range of 0.1A to 1.0A (0.7 MHz to 1.8 MHz) were applied to the exciting coil. The specimens were prepared with the slit shaped artificial surface flaws (minimum depth and width; 0.5 mm) on metallic plate (Al; nonmagnetic metal and FeC; magnetic metal). The detected signal for the positions and shapes of surface flaws on specimens were obtained with high sensitivity and high signal to ratio. The measured output signals by the non-contacted scanning on surface of FeC specimen with micron-sized crack were converted to the images of the flaws. And these results were compared with the optical images, respectively.

A Comparative Study on the Ultrastructures of the Egg Envelope in Fertilized Eggs of Fishes, Characidae, Three Species (카라신과 어류 3종의 수정란 난막 미세구조에 대한 비교 연구)

  • Kim, Dong-Heui;Reu, Dong-Suck;Deung, Young-Kun
    • Applied Microscopy
    • /
    • v.26 no.3
    • /
    • pp.277-291
    • /
    • 1996
  • The structures of the egg envelope in fertilized eggs of three species of characidae, head and tail light fish (Hemigrammus ocellifer), black tetra (Gymnocorymbus ternetzi), and buenos aires tetra (Hemigrammus caudovittatus) were studied using light and electron microscopes. The fertilized eggs in all species were colorless, transparent, spherical and non-floted type. The egg envelopes have a single micropyle resembling the pathway of sperm in the area of the animal pole. The micropyle was surrounded by protruded lines of the egg envelope in a radiated form. Egg envelopes of fertilized eggs in both head and tail light fish and buenos aires tetra consisted of three distinct layers; an outer layer, a middle layer and an inner layer. And that of blacktetra consisted of two layers; an outer layer and an inner layer. Also, an outer layers of both head and tail light fish and black tetra were adhesive types but, in that of buenous aires tetra was non-adhesive type. An outer surface of egg envelope in black tetra was arranged by pores regularly. In that of head and tail light fish and buenos aires tetra have a rough side. An inner layer of egg envelope in fertilized eggs consisted of lamellae alternating with interlamellae of lower electron density; an inner layer of fertilized eggs in head and tail light fish consisted of three layers, that of black tetra was four layers, and that of buenos aires tetra was five layers.

  • PDF