• 제목/요약/키워드: alpha track

검색결과 57건 처리시간 0.032초

Adaptive ${\alpha}-{\beta}$ Tracker for TWS Radar System

  • Kim, Byung-Doo;Lee, Ja-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.506-509
    • /
    • 2005
  • An adaptive ${\alpha}-{\beta}$ tracker is proposed for tracking maneuvering targets with a track-while-scan radar system. The tracker gain is updated on-line corresponding to the adjusted process noise variance which is obtained via time averaging of the process over a sliding window. The adjusted process noise variance is used to compute the maneuverability index for the tracker gain based on the steady-state Kalman filter equation for each epoch. It is shown via simulation that the proposed approach provides robust and accurate position estimates during the target maneuver while the performance of the conventional ${\alpha}-{\beta}$ tracker is shown much degraded.

  • PDF

Application of CR-39 Microfilm for Rapid Discrimination Between Alpha-Particle Sources

  • Dwaikat, Nidal;Al-Karmi, Anan M.
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.881-885
    • /
    • 2017
  • This work presents a new technique for discriminating between alpha particles of different energy levels. In a first study, two groups of alpha particles emitted from radium-226 and americium-241 sources were successfully separated using a CR-39 microfilm of appropriate thickness. This thickness was adjusted by chemical etching before and after irradiation so that lower-energy particles were stopped within the detector, while higher-energy particles were revealed on the back side of the detector. The number of tracks on the front side of the microfilm represented all alpha particles incident on that side from the two sources. However, the number of tracks on the back side of the microfilm represented only the long-range alpha particles of higher energy that arrived at that side. Therefore, by subtracting the number of tracks on the back side from the number of tracks on the front side, one could easily determine the number of tracks for the short-range alpha particles of lower energy that remained embedded in the microfilm. Discrimination of the two energy levels is thus achieved in a simple, fast, and reliable process.

Alpha 입자비적법(粒子飛跡法)에 의(依)한 Radon 측정(測定) (Radon Measurement by Alpha Particle Track Method)

  • 강영호;박장식;김도성
    • Journal of Radiation Protection and Research
    • /
    • 제7권1호
    • /
    • pp.17-22
    • /
    • 1982
  • 지표하에서 방출되는 토양기체중의 라돈농도 측정은 환경방사능, 우라늄탐색, 지진예지 등에 관한 연구에 널리 이용되고 있다. 본 연구에서는 초산 셀룰로우즈(LR115-Type2와 CA80-15, Kodak $Path\'{e}$)와 CR-39의 플라스틱 비적검출기를 부착한 라돈컵을 제작하여 경북일원에서의 토양기체중 라돈농도를 측정하였다. 제작한 라돈컵내에는 일정량의 $CaSO_4$를 건조제로 사용하여 플라스틱 검출기에 미치는 습기의 영향을 감소시켰으며, 라돈컵의 라돈검출 환산인자는 $1tr/cm^2{\cdot}30days=1.2{\times}1.0^{-2}pCi/l$였다. 1981년 1월부터 1982년 2월 사이의 대구에서의 평균 라돈농도는 39.1pCi/l였다. 한편 1981년 8월부터 1982년 2월 사이의 대구, 안강, 경주, 포항, 청하, 안동에서의 평균 라돈농도는 각각 31.8pCi/l, 124.5pCi/l, 127.0pCi/l, 79.1pCi/l, 144.4pCi/l, 70.9pCi/l였으며, 이 결과를 TLD에 의한 환경방사능 측정치와 비교하였다.

  • PDF

철도선로용량 계산을 위한 강인성 분석모형에 관한 연구 (A Study on Robustness Analysis Model for Calculating Line Capacity in Railroad System)

  • 이창호;김봉선;김학식;이병권;김동희;홍순흠
    • 산업공학
    • /
    • 제16권spc호
    • /
    • pp.111-115
    • /
    • 2003
  • Railroad system is consisted of resources of rail track, signal system, and vehicles. Railway operation must use these limited resources and maximize resource utilization. Line capacity(number of trains throughput/day) is determined by such as parameters, line utilization rate($\alpha$), dummy rate for the break-through hour($\beta$), and dummy rate for the number of rail track intervals($\delta$). Line capacity simulation(LCS) determined the line capacity through simulation given $\alpha$, $\beta$, and $\delta$. This paper deals with the development of parameter evaluation simulation(PES). PES presents the decision maker with the relationship of line capacity and measurement of robustness for various scenarios in different parameters and then the decision maker can determine the appropriate parameters.

지표공기중(地表空氣中)의 ${\alpha}$ 방사능측정(放射能測定) 및 해석(解析) (Measurement and Assessment of Alpha Activity in Ground Air)

  • 전재식;명동범
    • Journal of Radiation Protection and Research
    • /
    • 제11권2호
    • /
    • pp.130-138
    • /
    • 1986
  • CA 80-15 및 LR 115-1 cellulose nitrate 비적검출기를 사용하여 지표공기중의 ${\alpha}$방사능을 측정 해석하였는바 이 검출기의 검출효율은 $0.1{\mu}Ci$$^{241}Am\;{\alpha}$선을 사용하여 결정하였다. 지표에서 방출되는 라돈과 그 자핵종들에 의한 ${\alpha}$방사능을 검출하기 위하여 두가지의 라돈컵을 사용하였으며 이들을 각각 지름이 15cm, 깊이가 45cm인 이웃한 두개의 땅구덩이를 만들어 그 안에 설치하여 일정기간 ${\alpha}$방사능에 노출하였다. 두 라돈컵중 하나는 구덩이 지표면에 거꾸로 밀착시켜 밀폐공간이 되게 하고 다른 하나는 바닥에서 일정한 거리를 띄우고 컵 윗면에 구멍을 뚫어 공기의 소통이 가능하도록 하여 그 검출결과를 비교 검토하였다. ${\alpha}$입자에 피폭된 비적검출기는 부식처리한 후 현미경으로 판독하고 통계분석 하였으며 그 결과를 지표공기 단위부피당 ${\alpha}$방사능농도로 환산 평가하였다.

  • PDF

일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가 (Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings)

  • 정은교;김기웅
    • 한국산업보건학회지
    • /
    • 제27권1호
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.

Characterization of saturation of CR-39 detector at high alpha-particle fluence

  • Ghazaly, M. El;Hassan, Nabil M.
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.432-438
    • /
    • 2018
  • The occurrence of saturation in the CR-39 detector reduces and limits its detection dynamic range; nevertheless, this range could be extended using spectroscopic techniques and by measuring the net bulk rate of the saturated CR-39 detector surface. CR-39 detectors were irradiated by 1.5 MeV high alpha-particle fluence varying from $0.06{\times}10^8$ to $7.36{\times}10^8\;alphas/cm^2$ from Am-241 source; thereafter, they were etched in a 6.25N NaOH solution at a temperature of $70^{\circ}C$ for different durations. Net bulk etch rate measurement of the 1.5 MeV alpha-irradiated CR-39 detector surface revealed that rate increases with increasing etching time and reaches its maximum value at the end of the alpha-particle range. It is also correlated with the alpha-particle fluence. The measurements of UV-Visible (UV-Vis) absorbance at 500 and 600 nm reveal that the absorbance is linearly correlated with the fluence of alpha particles at the etching times of 2 and 4 hour. For extended etching times of 6, 10, and 14.5 hour, the absorbance is saturated for fluence values of $4.05{\times}10^8$, $5.30{\times}10^8$, and $7.36{\times}10^8\;alphas/cm^2$. These new methods pave the way to extend the dynamic range of polymer-based solid state nuclear track detectors (SSNTDs) in measurement of high fluence of heavy ions as well as in radiation dosimetry.

다중표적추적을 위한 효과적인 필터 알고리듬에 대한 연구 (A study of effective filter algorithms for multi-target tracking)

  • 이동관;송택렬
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.99-99
    • /
    • 2000
  • An effect ive filter algorithm that can manage radar beam pointing efficiently is needed to track multi-target in the air. For effective beam management the filter has lobe good enough to predict future position of target and based on this filter output radar beam is control led to point toward the predicted target position in the air. In this paper, we investigate the ${\alpha}$-${\beta}$ filter known for its brief filter structure with the steady-state Kalman filter gain, the ruv filter, and the coordinate-transformed filter that can decouple the measurement noise variance.

  • PDF

Photometric Reverberation Mapping with SQUEAN: A Test Study using Medium Bands

  • Taak, Yoon Chan;Im, Myungshin;Choi, Changsu
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.71.1-71.1
    • /
    • 2016
  • Photometric reverberation mapping is an effective alternative to time consuming spectroscopy. It usually employs narrow bands to track the luminosity variations of broad emission lines, such as Balmer lines, and broadbands for the continuum variability. Here, we investigate the feasibility of substituting these for medium bands, with 50nm widths, that are currently being used on the SED Camera for QUasars in EArly uNiverse (SQUEAN) installed on the 2.1m Otto Struve Telescope at McDonald Observatory. Three targets with recent variability and/or short expected time lags were selected, and observed for 15 minutes each in the medium band containing $H{\alpha}$, and the two adjacent bands for continuum subtraction afterwards. Analysis shows that for one of the objects, SDSS J0350+0037, the pure $H{\alpha}$ emission line flux has a S/N ~ 12, so that variabilities up to ~ 8% are detectable. Thus, future observations using these medium bands on SQUEAN seem to be practical.

  • PDF