• Title/Summary/Keyword: alpha/beta-ray discrimination

Search Result 3, Processing Time 0.014 seconds

Phoswich Detector for Simultaneous Measuring Alpha/beta Particles (알파/베타선 동시측정용 phoswich 검출기)

  • Kim, Gye-Hong;Park, Chan-Hee;Lee, Kune-Woo;Jung, Chong-Hun;Seo, Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • The new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for alpha/beta-ray simultaneous counting was developed for monitoring radiological contamination inside pipes. The detection performance was estimated using the PSD (pulse shape discrimination) method as a function of distance between the scintillator and radioactive source. The attenuation of particles traveling through a thin film for preventing the detector from being contaminated was experimentally estimated. It is concluded from our investigation that the phoswich detector developed can provide a sufficient alpha/beta-ray discrimination. The application of a thin film for preventing the detector from being contaminated was proven to be feasible.

  • PDF

Development of the ZnS(Ag)/BC-408 phoswich detector for monitoring radioactive contamination inside pipes (배관 내부 방사능 오염도 측정용 ZnS(Ag)/BC-408 phoswich 검출기 개발)

  • Kim, Gye-Hong;Park, Chan-Hee;Jung, Chong-Hun;Lee, Kune-Woo;Seo, Bum-Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.123-128
    • /
    • 2006
  • A small radiation detection system is necessary for the direct characterization of alpha/beta-ray contamination inside pipes generated during the decommission of a nuclear facility. In this work, the new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for ${\alpha}/{\beta}$ simultaneous counting was designed as part of a development of a equipment capable of monitoring radiological contamination inside pipes. The optimum counting conditions in dimensions of scintillator and a detection system were experimentally confirmed and a performance of alpha/beta-ray discrimination was evaluated. As a result, optimum conditions of a detector suitable for monitoring radiological contamination inside pipes and a feasibility of application to pipe-inside were confirmed.

Molecular docking study on the α3β2 neuronal nicotinic acetylcholine receptor complexed with α-Conotoxin GIC

  • Lee, Che-Wook;Lee, Si-Hyung;Kim, Do-Hyoung;Han, Kyou-Hoon
    • BMB Reports
    • /
    • v.45 no.5
    • /
    • pp.275-280
    • /
    • 2012
  • Nicotinic acetylcholine receptors (nAChRs) are a diverse family of homo- or heteropentameric ligand-gated ion channels. Understanding the physiological role of each nAChR subtype and the key residues responsible for normal and pathological states is important. ${\alpha}$-Conotoxin neuropeptides are highly selective probes capable of discriminating different subtypes of nAChRs. In this study, we performed homology modeling to generate the neuronal ${\alpha}3$, ${\beta}2$ and ${\beta}4$ subunits using the x-ray structure of the ${\alpha}1$ subunit as a template. The structures of the extracellular domains containing ligand binding sites in the ${\alpha}3{\beta}2$ and ${\alpha}3{\beta}4$ nAChR subtypes were constructed using MD simulations and ligand docking processes in their free and ligand-bound states using ${\alpha}$-conotoxin GIC, which exhibited the highest ${\alpha}3{\beta}2$ vs. ${\alpha}3{\beta}4$ discrimination ratio. The results provide a reasonable structural basis for such a discriminatory ability, supporting the idea that the present strategy can be used for future investigations on nAChR-ligand complexes.