• Title/Summary/Keyword: allowable stress

Search Result 581, Processing Time 0.029 seconds

Design Comparison of Composite Girder Bridges Designed by ASD and LRFD Methods (허용응력설계법 및 하중저항계수설계법에 의한 강합성 거더교 설계결과 비교)

  • Cho, Eun-Young;Shin, Dong-Ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.447-456
    • /
    • 2009
  • The design comparison and flexural reliability analysis of continuous span composite plate girder bridges are performed. The girders are designed by the methods of allowable stress design (ASD) and load and resistance factor design (LRFD). For the LRFD design, the design specification under development mainly by KBRC, based on AASHTO-LRFD specification in case of steel structures, is applied with the newly proposed design live load which has been developed by analyzing domestic traffic statistics from highways and local roads. For the ASD based design, the current KHBDC code with DB-24 and DL-24 live loads is used. The longest span length for the 3-span continuous bridges with span arrangement ratio of 4:5:4 is assumed to be from 30 m to 80 m. The amount of steel, performance ratios, and governing design factors for the sections designed by the ASD and LRFD methods are compared. In the reliability analysis for the flexural failure of the sections designed by two methods, the statistical properties on flexural resistance based on the yield strength statistics for over 16,000 domestic structural steel samples are applied.

Compression Test of a TBM Thrust Jack for Validating Buckling Stability (TBM 추진잭의 좌굴 안정성 검토를 위한 압축시험)

  • Mun-Gyu Kim;Min-Gi Cho;Jung-Woo Cho;Han-Young Jeong
    • Tunnel and Underground Space
    • /
    • v.33 no.5
    • /
    • pp.339-347
    • /
    • 2023
  • As the jacks provide a thrust force on the inclined surface, bending deformations by a side force occur in the pedestal and rod parts. This can induce disorder or degradation of the thrust module, buckling stability on the inclined compression condition should be clarified to secure the reliability of shield TBM. For analyzing the stability, a buckling testing method for hydraulic cylinder was investigated and compression testing system was installed. Before the test, a numerical analysis was conducted to check the stress concentration parts. The maximum allowable force was loaded on the cylinder specimen at 0 degree surface condition as a preliminary test. After the test, plastic deformations or hydraulic leakage was not observed. The static stability of it was verified at 0 degree condition.

A Study on Structural Behavior of Composite Deck Plate using a Pre-assembled Re-bar Truss (철근 선조립형 복합 데크플레이트의 하부근 선경축소에 따른 구조적 거동 평가)

  • Yoo, Byung-Uk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.129-138
    • /
    • 2006
  • Composite deck plate using a pre-assembled re-bar truss for slab with corrugated zinc galvanized sheet iron at manufactory, is given the improvement on design, manufacture, and performance for construction work of cast-in-place reinforced concrete slab by enabling to cast concrete directly without the form work. There are two methods in analyzing composite deck : Simplified 2D analysis and 3D analysis. Although simplified 2D analysis is being used up to date, the use of 3D analysis, allowing for the vierendeel behavior of composite deck by real configuration correlating to bar reducing, is demanded. To compare the simplified 2D analysis applied to allowable stress design with 3D analysis applied to limit state design, 8 specimen are manufactured. Main variables include the depth of slab, the length of span, the diameter of bottom bar and lattice bar, and the presence of corrugated zinc galvanized sheet iron. The comparison from the experimental result and analytical result indicates that applying of simplified 2D analysis is possible for the use of D10 with bottom bar. However, it is more reasonable to apply 3D analysis which allows to indicate vierendeel behavior considered the real configuration.

Shape Optimization of the Plane Truss Structures by Mixed Cooridination Method (혼합조정법(混合調整法)에 의한 평면(平面) 트러스 구조물(構造物)의 형상최적화(形狀最適化)에 관한 연구(硏究))

  • Lee, Gyu Won;Lim, Jeong Whan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.55-68
    • /
    • 1991
  • In this study, Mixed coordination method was selected to optimize the shape of the truss structures which takes multi-loading condition, allowable stress, buckling stress, displacement constraints into consideration. The structure was devided into substructures by Goal coordination method and the substructures were optimized by model coordination method which used two-level technique. Therefore the number of design variables and constrints can be decreased considerable. Under the condition of the same disign, the weight of truss structures can be decreased more considerable by means of optimizing even the shape of truss than by means of optimizing the section of truss while fixing geometrical configuration of it, even though there might be a little difference according to the early geomatrical shape of the truss and the design condition. Thus, the shape optimization of truss structures which utilize the results of this study can be helpful to the economical design of truss structures.

  • PDF

A Study on the Cause and Improvement of Crack in the Installing Structure of the Bulkhead of Aircraft (항공기 Bulkhead 체결구조의 균열 원인 및 개선에 관한 연구)

  • Choi, Hyoung Jun;Park, Sung Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.448-454
    • /
    • 2020
  • This study aims to determine the cause of structural defects occurring during aircraft operations and to verify the structural integrity of the improved features. The fracture plane was analyzed to verify the characteristics of the cracks and the fatigue failure leading to the final fracture was determined by the progress of the cracks by the repeated load. During aircraft operations, the comparative analysis of the load measurement data at the cracks with the aircraft design load determined that the measured load was not at the level of 30% of the design to be capable of being damaged. A gap analysis resulted in a significant stress of approximately 32 ksi at the crack site. Pre-Load testing also confirmed that the M.S. was reduced by more than 50% from +0.71 to +0.43, resulting in a sharp increase in aircraft load and the possibility of cracking when combined. Thus, structural reinforcement and the removal of the gap for aircraft cracking sites improved the defect. Based on the structural strength analysis of the improvement features, the bulkhead has a margin of about +0.88 and the fitting feature is about +0.48 versus allowable stress. In addition, the life analysis results revealed an improvement of approximately 84000 hours.

Evaluation on Bearing Resistance of Transverse Members in Steel Strip Reinforcement using Pullout Tests and Theoretical Equations (인발시험과 이론식을 이용한 강재스트립 보강재에 설치된 지지부재의 지지저항 특성 평가)

  • Han, Jung-Geun;Yoon, Won-Il;Hong, Ki-Kwon;Hong, Won-Pyo;Lee, Kwang-Wu;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.2
    • /
    • pp.33-40
    • /
    • 2010
  • In this study, the pullout tests are conducted to evaluate pullout resistance of steel strip reinforcement with transverse members. The test results are compared with theoretical equations and then the failure mechanism of transverse members is evaluated. The bearing resistance stress(${\sigma}^{\prime}_b$) of transverse members, which is applied pullout force at 50mm displacement, is closed from punching shear failure to general shear failure. The behavior by increment of a number of transverse members became closer to general shear failure. The behavior of transverse members at maximum pullout force, which is closed to general shear failure, is indicated that it is unrelated to normal stress and a number of transverse members. However, if the allowable displacement of reinforced soil wall is considered, it is impossible to apply in design. The test results are compared with bearing resistance evaluations using Prandtl's plastic theory and cylindrical cavity expansion theory. The analysis results are indicated that the bearing resistance by pullout tests is closed to predicted result by Prandtl's plastic theory, which are located between general shear failure and punching shear failure.

  • PDF

Centralized Controller High-altitude Work Car Elevations Lift Structure Safety Assessment (중앙집중식 컨트롤러 고소작업차의 고소리프트의 구조안정성 평가)

  • Kim, Jun-tae;Lee, Gi-yeong;Lee, Sang-sik;Park, Won-yeop
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.4
    • /
    • pp.350-357
    • /
    • 2017
  • This study was conducted as a post - study on the development of a centralized controller and a hydraulic lift system including structural analysis and remote control for the development of a vertically elevated car. The safety review was carried out through the structural modification of the elevator lift which was developed during the previous research. 3D modeling was performed with Solidworks, and a model of finite element was created through Hypermesh S / W. In addition, the loading environment of the work vehicle for the evaluation is a condition in which the loading amount is 250 kg per position (total, upper, upper, lower, and lower) on the work table, ), The structural analysis was carried out under the condition that the load was 600 kg, and safety was examined in various aspects. As a result, when the allowable load of 250 kg and the excess load of 600 kg are excluded (except Case-11), the stress level is below the yield strength. In the case of Case-11, there is a region exceeding the yield strength at the center support portion of the safety bar at the upper end even after excluding the component which generates the maximum stress, but it does not affect the safety aspect of the whole structure Respectively. Looking at the deflection results, it can be seen that in all cases the maximum deflection occurs in the same table, and the tendency of sagging in both 250 kg and 600 kg is the same.

Behaviour of single piles and pile groups in service to adjacent tunnelling conducted in the lateral direction of the piles (사용 중인 단독 및 군말뚝의 측면에서 실시된 터널굴착으로 인한 말뚝의 거동)

  • Lee, Cheol-Ju
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.4
    • /
    • pp.337-356
    • /
    • 2012
  • Three-dimensional (3D) numerical analyses have been performed to study the behaviour of single piles and grouped piles to adjacent tunnelling in the lateral direction of the pile. In the numerical analyses, the interaction between the tunnel, the pile and the soil next to the piles and shear transfer mechanism have been analysed allowing soil slip at the pile-soil interface by using interface elements. The study includes the shear stresses at the soil next to the pile, the axial force distributions on the pile and the pile settlement. It has been found that existing elastic solutions may not accurately estimate the pile behaviour since several key issues are excluded. Due to changes in the shear transfer between the pile and the soil next to the pile with tunnel advancement, the shear stresses and axial force distributions along the pile change drastically. Downward shear stress develops above the tunnel springline while upward shear stress is mobilised below the tunnel springline, resulting in a compressive force on the pile. In addition, mobilisation of shear strength at the pile-soil interface was found to be a key factor governing pile-soil-tunnelling interaction. It has been found that grouped piles are less influenced by the tunnelling than the single pile in terms of the axial pile forces. The reduction of apparent allowable pile capacity due to pile settlement resulted from the tunnelling seemed to be insignificant.

Comparative analysis of cutter acting forces and axial stresses of single and double disc cutters by linear cutting tests (선형절삭시험에 의한 더블디스크커터와 싱글디스크커터의 커터 작용력과 축응력에 대한 실험적 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Park, Young-Taek;Lee, Gyu-Phil;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.181-191
    • /
    • 2014
  • This study aims to evaluate cutter acting forces as well as axial stresses and torques in the shaft of two kinds of disc cutters including a single disc cutter and a double disc cutter with the same cutter ring geometry in a series of linear cutting tests. From the tests, the mean values of normal forces and rolling forces acting on the double disc cutter were approximately twice as high as those from the single disc cutter. Similarly, the mean values of axial stresses in the shaft of the double disc cutter were also twice as high as those from the single disc cutter even though the comparisons of torques from two kinds of disc cutters were insignificant since they showed very low values. However, it is necessary to take the durability of a tapered roller bearing used for the double disc cutter into high consideration since the average normal force from the double disc cutter exceeds the allowable force for a disc cutter with the diameter of 432 mm (17 inches). Finally, there is no practical problem in terms of axial stresses in the shaft of the double disc cutter since they are much lower than the yielding stress of the cutter shaft material, even though the axial stresses in the shaft of the double disc cutter are approximately twice as high as those from the single disc cutter.

Experimental Studies on the Structural Safety of Pipe-Houses (파이프하우스의 구조안전에 관한 실험적 연구)

  • 김문기;남상운
    • Journal of Bio-Environment Control
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 1995
  • This study was carried out to make fundamental data for structural safety test of pipe- houses. Experiment on the stress distribution of pipe- houses was conducted to find suitable structural analysis model by examination of end support conditions of pipe. Besides, the loading test and the pile driving test were done to find pull-out capacity and bearing capacity of pipe on the assumption that pipe is pile foundation. For single span pipe - house, the theoretical results assuming the end support condition of pipe is fixed under ground agreed closely with the experimental results of stress distribution. On the other hand for double span pipe -house, the end support conditions of pipe were fixed support when vertical load is applied, and hinged one when horizontal load is applied. The pull - out capacity and allowable bearing capacity of the pipe portion that was buried in the grounds that were soft soil of paddy field and medium or hard soils of dry field derived from experimental results.

  • PDF