• Title/Summary/Keyword: allowable level

Search Result 336, Processing Time 0.023 seconds

Target Reliability Index of Single Gravel Compaction Piles for Limit State Design (한계상태설계를 위한 단일 쇄석다짐말뚝의 목표신뢰도지수)

  • You, Youngkwon;Lim, Heuidae;Park, Joonmo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.5-15
    • /
    • 2014
  • Target reliability index in the limit state design indicated the safety margin and it is important to determine the partial factor. To determine the target reliability index which is needed in the limit state design, the six design and construction case histories of gravel compaction piles (GCP) were investigated. The limit state functions were defined by bulging failure for the major failure mode of GCP. The reliability analysis were performed using the first order reliability method (FORM) and the reliability index was calculated for each ultimate bearing capacity formulation. The reliability index of GCP tended to be penportional to the safety factor of allowable stress design and average value was ${\beta}$=2.30. Reliability level that was assessed by reliability analysis and target reliability index for existing structure foundations were compared and analyzed. As a result, The GCP was required a relatively low level of safety compared with deep and shallow foundations and the currd t reliability level were similar to the target reliability in the reinforced earth retaining-wall and soil-nailing. Therefore the target reliability index of GCP suggested as ${\beta}_T$=2.33 by various literatures together with the computed reliability level in this study.

Comparative Study of Reliability Design Methods by Application to Donghae Harbor Breakwaters. 2. Sliding of Caissons (동해항 방파제를 대상으로 한 신뢰성 설계법의 비교 연구. 2. 케이슨의 활동)

  • Kim, Seung-Woo;Suh, Kyung-Duck;Oh, Young-Min
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.2
    • /
    • pp.137-146
    • /
    • 2006
  • This is the second of a two-part paper which describes comparison of reliability design methods by application to Donghae Harbor Breakwaters. In this paper, Part 2, we deal with sliding of caissons. The failure modes of a vertical breakwater, which consists of a caisson mounted on a rubble mound, include the sliding and overturning of the caisson and the failure of the rubble mound or subsoil, among which most frequently occurs the sliding of the caisson. The traditional deterministic design method for sliding failure of a caisson uses the concept of a safety factor that the resistance should be greater than the load by a certain factor (e.g. 1.2). However, the safety of a structure cannot be quantitatively evaluated by the concept of a safety factor. On the other hand, the reliability design method, for which active research is being performed recently, enables one to quantitatively evaluate the safety of a structure by calculating the probability of failure of the structure. The reliability design method is classified into three categories depending on the level of probabilistic concepts being employed, i.e., Level 1, 2, and 3. In this study, we apply the reliability design methods to the sliding of the caisson of the breakwaters of Donghae Harbor, which was constructed by traditional deterministic design methods to be damaged in 1987. Analyses are made for the breakwaters before the damage and after reinforcement. The probability of failure before the damage is much higher than the allowable value, indicating that the breakwater was under-designed. The probability of failure after reinforcement, however, is close to the allowable value, indicating that the breakwater is no longer in danger. On the other hand, the results of the different reliability design methods are in fairly good agreement, confirming that there is not much difference among different methods.

Studies on the Contamination of Kimchi Material - Pesticide Residues in Vegitables - (김치의 오염(汚染)에 관(關)한 연구(硏究) - 김치 재료(材料)의 농약오염(農藥汚染) -)

  • Yoon, Suk-Kyung
    • Journal of Nutrition and Health
    • /
    • v.13 no.1
    • /
    • pp.51-58
    • /
    • 1980
  • In order to investigate the level of pesticide residues in the vegetables for Kimchi materials (Chinese cabbage, radish, red pepper, garlic and cucumber), which were produced in Andong district, organochlorine and organophosphur pesticide residues were analyzed using gas chromatography. The results were as follows; 1) In chinese cabbage, radish and some other vegetables harvested in early summer (June), organochlorine and organophosphur pesticide residues were detected in almost all of the samples tested, and a few of them showed a level higher than the organochlor APR(allowable pesticide residues). 2) Heptachlor, the soil insecticide was the most abundantly detected pesticide among the four organochlorine pesticides tested (Dieldrin, Endrin, BHC, Heptachlor) in this study. 3) Somewhat higher concentrations of organochlorine pesticides were detected in all kinds of sample vegetables harvested in late summer than in those harvested in early summer. And the frequency of organochlorine pesticide contamination was also increased, but the frequency of organophosphur pesticide contamination was decreased. 4) In the vegetable harvested in late autumn, level of organochlorine pesticide residues and frequency of contamination were markedly decreased and organophosphur pesticide residues (Diaginon, Malathion, Thiometon, EPN) were rarely detected. 5) The results of this study indicates that to take a lot of vegitables grown in summer was somewhat uncomfortable than those grown in autumn.

  • PDF

Safety Evaluation of Radioactive Material Transport Package under Stacking Test Condition (방사성물질 운반용기의 적층시험조건에 대한 안전성 평가)

  • Lee, Ju-Chan;Seo, Ki-Seog;Yoo, Seong-Yeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.1
    • /
    • pp.37-43
    • /
    • 2012
  • Radioactive waste transport package was developed to transport eight drums of low and intermediate level waste(LILW) in accordance with the IAEA and domestic related regulations. The package is classified with industrial package IP-2. IP-2 package is required to undergo a free drop test and a stacking test. After free drop and stacking tests, it should prevent the loss or dispersal of radioactive contents, and loss of shielding integrity which would result in more than 20 % increase in the radiation level at any external surface of the package. The objective of this study is to establish the safety test method and procedure for stacking test and to prove the structural integrities of the IP-2 package. Stacking test and analysis were performed with a compressive load equal to five times the weight of the package for a period of 24 hours using a full scale model. Strains and displacements were measured at the corner fitting of the package during the stacking test. The measured strains and displacements were compared with the analysis results, and there were good agreements. It is very difficult to measure the deflection at the container base, so the maximum deflection of the container base was calculated by the analysis method. The maximum displacement at the corner fitting and deflection at the container base were less than their allowable values. Dimensions of the test model, thickness of shielding material and bolt torque were measured before and after the stacking test. Throughout the stacking test, it was found that there were no loss or dispersal of radioactive contents and no loss of shielding integrity. Thus, the package was shown to comply with the requirements to maintain structural integrity under the stacking condition.

A Comparative Analysis of Maximum Entropy and Analytical Models for Assessing Kapenta (Limnothrissa miodon) Stock in Lake Kariba (카리브호수 카펜타 자원량 추정을 위한 최대엔트피모델과 분석적 모델의 비교분석)

  • Tendaupenyu, Itai Hilary;Pyo, Hee-Dong
    • Environmental and Resource Economics Review
    • /
    • v.26 no.4
    • /
    • pp.613-639
    • /
    • 2017
  • A Maximum Entropy (ME) Model and an Analytical Model are analyzed in assessing Kapenta stock in Lake Kariba. The ME model estimates a Maximum Sustainable Yield (MSY) of 25,372 tons and a corresponding effort of 109,731 fishing nights suggesting overcapacity in the lake at current effort level. The model estimates a declining stock from 1988 to 2009. The Analytical Model estimates an Acceptable Biological Catch (ABC) annually and a corresponding fishing mortality (F) of 1.210/year which is higher than the prevailing fishing mortality of 0.927/year. The ME and Analytical Models estimate a similar biomass in the reference year 1982 confirming that both models are applicable to the stock. The ME model estimates annual biomass which has been gradually declining until less than one third of maximum biomass (156,047 tons) in 1988. It implies that the stock has been overexploited due to yieldings over the level of ABC compared to variations in annual catch, even if the recent prevailing catch levels were not up to the level of MSY. In comparison, the Analytical Model provides a more conservative value of ABC compared to the MSY value estimated by the ME model. Conservative management policies should be taken to reduce the aggregate amount of annual catch employing the total allowable catch system and effort reduction program.

A Study on Characteristics and Modeling of CMV by Grounding Methods of Transformer for ESS (ESS용 변압기의 접지방식에 의한 CMV 모델링 및 특성에 관한 연구)

  • Choi, Sung-Moon;Kim, Seung-Ho;Kim, Mi-Young;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.587-593
    • /
    • 2021
  • Since 2017, a total of 29 fire accidents have occurred in energy storage systems (ESSs) as of June 2020. The common mode voltage (CMV) is one of the electrical hazards that is assumed to be a cause of those fire accidents. Several cases of CMV that violate the allowable insulation level of a battery section are being reported in actual ESS operation sites with △-Y winding connections. Thus, this paper evaluates the characteristics of CMV. An ESS site was modeled with an AC grid, PCS, and battery sections using PSCAD/EMTDC software. As a result of a simulation based on the proposed model, it was confirmed that characteristics of CMV vary significantly and are similar to actual measurements, depending on the grounding method of the internal transformer for PCS. The insulation level of the battery section may be severely degraded as the value of CMV exceeds the rated voltage in case of a grounding connection. It was found that the value of CMV dramatically declines when the internal transformer for PCS is operated as non-grounding connection, so it meets the standard insulation level.

Appropriateness Evaluation of Train Vibration Evaluation Method Considering Vibration Levels of Retaining Wall Adjacent to Railway Tunnels (철도터널과 인접한 흙막이 가시설의 진동 수준을 고려한 열차진동 평가방법의 적정성 평가)

  • Donghee Woo;Yeongjin Lee;Yongjae Song;Kangil Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.10
    • /
    • pp.5-13
    • /
    • 2023
  • With the recent increase in development projects centered on urban areas, the construction of building structures is increasing in areas adjacent to the urban railway operation section. In this case, since ground vibration is generated by the train in operation and affects the adjacent structure, the building structure needs appropriate vibration reduction against train vibration generated at the adjacent location from the desing phase. However, the vibration levels calculated vary depending on the train vibration evaluation method, which means that the implementation of vibration reduction may vary depending on the train vibration evaluation method. Therefore, this study calculated the vibration level according to ground conditions, tunnel depth and separation distance between vibration sources and adjacent structures using numerical analysis and train vibration evaluation methods, and compared them to designning phase. And the appropriate separation distance between the tunnel and the adjacent structure was evaluated by comparing the vibration level with the allowable standards. As a result of the study, the Ungar and Bender evaluation method is evaluated as the most appropriate among the train vibration evaluation methods, and the appropriate separation distance between the tunnel and the adjacent structure is evaluated to be more than 4.5D.

Effect of Light Receiving rate on Growth and Quality of Ginseng Cultivated in Plastic House

  • Sang Young Seo;Jong hyeon Cho;Chang Su Kim;Hyo Jin Kim;Min Sil An;Du Hyeon Yoon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.12a
    • /
    • pp.62-62
    • /
    • 2020
  • Ginseng is a shade-plant cultivated using shading facilities. However, at too low light levels, root growth is poor, and at high light levels, the destruction of chlorophyll reduces the photosynthesis efficiency due to leaf burn and early fall leaves. The ginseng has a lightsaturation point of 12,000~15,000 lux when grown at 15 to 20℃ and 9,500 lux at 25℃. This study was conducted to select the optimal light intensity of 3-year-old ginseng grown in blue-white film plastic house. The seeds were planted in the blue-white film plastic house with different light receiving rate (March 17, 2020). Between April and September, the average air temperature in the house was 20.4-20.7℃. Average soil temperature was 18.3℃-18.5℃. The chemical properties of the test soil was as follows. The pH level was 7.0-7.4, EC was 0.5-0.6 dS/m, OM was at the levels of 33.6-37.7 g/kg, P2O5 was 513.0-590.8 mg/kg, slightly higher than the allowable 400 mg/kg. The amount of light intensity, illuminance, and solar radiation in the blue-white film house was increased as the light-receiving rate increased and the amount of light intensity was found to be 9-14% compared to the open field, 8-13% illuminance and 9-14% solar irradiation respectively. The photosynthesis rate was the lowest at 3.1 µmolCO2/m2/s in the 9% light blue-white plastic house and 4.2 and 4.0 µmolCO2/m2/s in the 12% and 14% light blue-white plastic house, respectively. These results generally indicate that the photosynthesis of plants increases with the amount of light, but the ginseng has a lower light saturation point at high temperatures, and the higher the amount of light, the lower the photosynthetic efficiency. The SPAD (chlorophyll content) value decreased as the increase of light-receiving rate, and was the highest at 32.7 in 9% light blue-white plastic house. Ginseng germination started on April 11 and took 13-15 days to germinate. The overall germination rate was 82.9-85.8%. The plant height and length of stem were long in the 9% light-receiving plastic house. The diameter of stem was thick in the 12-14% light-receiving plastic house. In the 12% and 14% light-receiving plastic house, the length and diameter of taproot was long and thick, so the fresh weight of root per plant was 20 g or more, which was heavier than 16.9 g of the 9% light-receiving plastic house. The disease incidence (Alternaria blight, Gray mold and Damping-off etc.) rate were 0.9-2.7%. The incidence of Sclerotinia rot disease was 7.5-8.4%, and root rot was 0-20.0%. The incidence ratio of rusty root ginseng was 34.4-38.7% level, which was an increase from the previous year's 15% level.

  • PDF

Optimal Configuration of the Truss Structures by Using Decomposition Method of Three-Phases (3단계(段階) 분할기법(分割技法)에 의한 평면(平面)트러스 구조물(構造物)의 형상(形狀) 최적화(最適化)에 관한 연구(硏究))

  • Lee, Gyu Won;Song, Gi Beom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.39-55
    • /
    • 1992
  • In this research, a Three Level Decomposition technique has been developed for configuration design optimization of truss structures. In the first level, as design variables, behavior variables are used and the strain energy has been treated as the cost function to be maximized so that the truss structure can absorb maximum energy. For design constraint of the optimal design problem, allowable stress, buckling stress, and displacement under multi-loading conditions are considered. In the second level, design problem is formulated using the cross-sectional area as the design variable and the weight of the truss structure as the cost function. As for the design constraint, the equilibrium equation with the optimal displacement obtained in the first level is used. In the third level, the nodal point coordinates of the truss structure are used as coordinating variable and the weight has been taken as the cost function. An advantage of the Three Level Decomposition technique is that the first and second level design problems are simple because they are linear programming problems. Moreover, the method is efficient because it is not necessary to carry out time consuming structural analysis and techniques for sensitivity analysis during the design optimization process. By treating the nodal point coordinates as design variables, the third level becomes unconstrained optimal design problems which is easier to solve. Moreover, by using different convergence criteria at each level of design problem, improved convergence can be obtained. The proposed technique has been tested using four different truss structures to yield almost identical optimum designs in the literature with efficient convergence rate regardless of constraint types and configuration of truss structures.

  • PDF

Cost-effective Investigation on Contaminated Land and Assessment of Measurement Uncertainty (오염토양의 효율적 조사기법과 측정불확도의 평가방법)

  • 이종천
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.49-59
    • /
    • 2004
  • The concectration and distribution of contaminants obtained from a contaminated land investigation or an environmental geochemistry survey constitutes the basis of a decision-making process on environmental policies or of scientific researches. As the quality of data determines the reliability of the result, the investigation plan should be adjusted according to the purpose of the investigation. In general, the effort to improve the data quality had been focused mainly on the QA/QC procedures in laboratories. The rapid progress of analytical instrument has also contributed toward improving the analytical precision to a sacrificable degree. Nevertheless, in many cases, it is not the analytical precision that needs improvement for the better precision of overall measurement process: it is rather during the sampling process in the field that is responsible for the poor precision. To assess the data quality on a measured value, ISO recommends to provide information on "measurement uncertainty" along with the measured value. The measurement uncertainty in an environmental measurement context can be explained as the statistical number that expresses the degree of the uncertainty stemming from the sampling and analytical procedures. There is a cost involved in order to improve the precision of sampling and analytical methods so as to decrease the degree of measurement uncertainty. The economical point of compromise in an investigation planning can be achieved when the allowable degree of uncertainty has been set before-hand. The investigation can then be planned accordingly not to exceed the uncertainty limit. Furthermore, if the measurement uncertainty estimated from the preliminary investigation can be separated into sampling and analytical uncertainties, it can be used as a criterion where the resources for the investigation should be allotted cost-effectively to reinforce the weakest link of the whole investigation process. This paper aims to present a method of estimating the level of measurement uncertainty of a measured contamination concentration at a site used as an example and to show how the estimated uncertainty can be applied to serve the particular purpose of an investigation.