• Title/Summary/Keyword: all inspection

Search Result 1,040, Processing Time 0.031 seconds

Development of an intelligent and integrated system for automatic inspection of steam-generator tubes in nuclear power plant (원전 증기 발생기 전열관 검사 자동화를 위한 지능형 통합 시스템 개발)

  • Kang, Soon-Ju;Choi, Yoo-Rark;Choe, Seong-Su;Woo, Hee-Gon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.3
    • /
    • pp.236-241
    • /
    • 1996
  • This paper presents a new eddy current testing system for inspecting tubes of steam generator in nuclear power plant. The proposed system adopted embedded expert system concept to automate tasks of the inspection such as inspection planning and flaw signal interpretation, and integrated all the tasks into a client/server type computing architecture using database management system. Therefore, human factor errors occurred during inspection could be minimized and the inspection data could be transferred in real-time. As a result, we can increase the level of inspection confidence and the productivity of a personal inspector. A prototype of the proposed system has been developed for 5 years and the test operation has been performed in domestic nuclear power plants.

  • PDF

Feasibility study of spent fuel internal tomography (SFIT) for partial defect detection within PWR spent nuclear fuel

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Hyun Joon Choi;Hakjae Lee;Yong Hyun Chung;Chul Hee Min
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2412-2420
    • /
    • 2024
  • The International Atomic Energy Agency (IAEA) mandates safeguards to ensure non-proliferation of nuclear materials. Among inspection techniques used to detect partial defects within spent nuclear fuel (SNF), gamma emission tomography (GET) has been reported to be reliable for detection of partial defects on a pin-by-pin level. Conventional GET, however, is limited by low detection efficiency due to the high density of nuclear fuel rods and self-absorption. This paper proposes a new type of GET named Spent Fuel Internal Tomography (SFIT), which can acquire sinograms at the guide tube. The proposed device consists of the housing, shielding, C-shaped collimator, reflector, and gadolinium aluminum gallium garnet (GAGG) scintillator. For accurate attenuation correction, the source-distinguishable range of the SFIT device was determined using MC simulation to the region away from the proposed device to the second layer. For enhanced inspection accuracy, a proposed specific source-discrimination algorithm was applied. With this, the SFIT device successfully distinguished all source locations. The comparison of images of the existing and proposed inspection methods showed that the proposed method, having successfully distinguished all sources, afforded a 150 % inspection accuracy improvement.

A Profile Tolerance Usage in GD&T for Precision Manufacturing (정밀제조를 위한 기하공차에서의 윤곽공차 사용)

  • Kim, Kyung-Wook;Chang, Sung-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.2
    • /
    • pp.145-149
    • /
    • 2017
  • One of the challenges facing precision manufacturers is the increasing feature complexity of tight tolerance parts. All engineering drawings must account for the size, form, orientation, and location of all features to ensure manufacturability, measurability, and design intent. Geometric controls per ASME Y14.5 are typically applied to specify dimensional tolerances on engineering drawings and define size, form, orientation, and location of features. Many engineering drawings lack the necessary geometric dimensioning and tolerancing to allow for timely and accurate inspection and verification. Plus-minus tolerancing is typically ambiguous and requires extra time by engineering, programming, machining, and inspection functions to debate and agree on a single conclusion. Complex geometry can result in long inspection and verification times and put even the most sophisticated measurement equipment and processes to the test. In addition, design, manufacturing and quality engineers are often frustrated by communication errors over these features. However, an approach called profile tolerancing offers optimal definition of design intent by explicitly defining uniform boundaries around the physical geometry. It is an efficient and effective method for measurement and quality control. There are several advantages for product designers who use position and profile tolerancing instead of linear dimensioning. When design intent is conveyed unambiguously, manufacturers don't have to field multiple question from suppliers as they design and build a process for manufacturing and inspection. Profile tolerancing, when it is applied correctly, provides manufacturing and inspection functions with unambiguously defined tolerancing. Those data are manufacturable and measurable. Customers can see cost and lead time reductions with parts that consistently meet the design intent. Components can function properly-eliminating costly rework, redesign, and missed market opportunities. However a supplier that is poised to embrace profile tolerancing will no doubt run into resistance from those who would prefer the way things have always been done. It is not just internal naysayers, but also suppliers that might fight the change. In addition, the investment for suppliers can be steep in terms of training, equipment, and software.

Investigation of occurrence factors on brucellosis-outbreak farm in Korea (소 브루셀라병 동시 다두 발생 농장의 발생 요인 조사)

  • Kim, Ji-Yeon;Kang, Shin-Seok;Her, Moon;Lee, Kichan;Sung, So-Ra;Gu, Jung-Hui;Kang, Sung-Il;Lee, Hyang-Keun;Kim, Yu-Jin;Kim, Dong-Gil;Jung, Suk-Chan
    • Korean Journal of Veterinary Service
    • /
    • v.35 no.4
    • /
    • pp.263-268
    • /
    • 2012
  • From the end of July 2012, several cases of abortion have been happened at the Korean indigenous cattle farm with 124 heads in Chungbuk province, Korea. Serological tests such as Rose-bengal test (RBT) and standard tube agglutination test (STAT) have been performed according to the standard official protocols of bovine brucellosis and 41 cattle turned out to be brucellosis-positive simultaneously. To find out the main factors of brucellosis outbreaks and spreads, additional serological, etiological and molecular investigation were applied. Totally, 11 B. abortus were isolated from 10 cattle's specimens including lymph-nodes and/or testis, and drinking water in cowhouse. In genotyping by multi-locus VNTR assay (MLVA) using 17 loci markers, the present B. abortus isolates were shown all the same pattern, D1 genotype, which has been reported in Gyeonggi and Gangwon province, Korea. These results suggest that the input of brucellosis might come from neighboring farms directly or indirectly, even if by unknown factor and expansion within farm would accelerate by materials related with aborting cows.

Survey on Pesticide Residues in Commercial Agricultural Products in the Northern Area of Seoul(2008) (서울특별시 강북지역 유통 농산물 중 농약잔류실태조사(2008))

  • Seung, Hyun-Jung;Park, Sung-Kyu;Ha, Kwang-Tae;Kim, Ouk-Hee;Choi, Young-Hee;Kim, Si-Jung;Lee, Kyeong-Ah;Jang, Jung-Im;Jo, Han-Bin;Choi, Byung-Hyun
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.4
    • /
    • pp.357-367
    • /
    • 2009
  • This study was carried out to investigate the current status of pesticide residues in 3,735 agricultural products in the northern area of Seoul from January to December in 2008. 3,735 samples, comprising 119 types of agricultrural products were assessed via a multiresidue method to detect 260 pesticides. Pesticide residues were detected in 19.7% (737 of 3,735 samples), and the rate at which the detected residues violated the maximum residue levels(MRLs) of the Korean Food Code was 3.2% (121 of 3,735 samples). Pesticide residues were detected in 72 spin-aches, 64 peppers, 45 sweet peppers, 40 perilla leaves, 38 korean cabbages and 37 dried agricultural products. The samples that violated the MRLs included 14 perilla leaves, 13 spinaches, 12 leek, 6 lettuces(leaf), 6 chards and 6 gyeojchaes. Procymidone, endosulfan, chlorfenapyr, cypermethrin, bifenthrin, tebuconazole and fenvalerate were all frequently observed. Procymidone, endosulfan, dimethomorph and diniconazole were the pesticides most frequently detected at levels that violated the Korean Food Code MRLs.

Legal Aspects on the Procedures and Settlement of the Disputes arising from the WTO Preshipment Inspection (WTO 선적전검사제도에 따른 실태와 분쟁조정의 해결에 관한 고찰)

  • Seo, Jeong-Il
    • Journal of Arbitration Studies
    • /
    • v.8 no.1
    • /
    • pp.293-322
    • /
    • 1998
  • General Administrative Procedures of the Preshipment Inspection 1. Initial notification Preshipment Inspection is initiated by Agency when it receives notice either from the importing country, or the seller, that an export needs to be imspected 1.1 Notice from the importing country 1.2 Notice from the seller 2. Preliminary price verification After receipt of initial notification, Agency undertakes, Where possible, a preliminary price verification, based upon the Inspection Order and other contractual documents received. 3. Customs classification When required by the Government of the importing country. Agency forms an opinion of the Customs Classification Code based upon the Customs Tariff Book and Rules of Classification of the country of importation. The Customs Classification Code determines the tariff rate on the basis of which the importer will be required to pay import duties. 4. Import eligibility 5. Arrangements for physical inspection 5.1 Inspection request from seller 5.2 Place of inspection 5.3 Date of inspection 5.4 Physical inspection procedures 6. Physical inspection results When the physical inspection is completed, the inspector submits his report to the Agency office and the result of inspection will be communicated to the seller and, where applicable, the place of inspection. The result will state: satisfactory or conditional of unsatisfactory. The seller is welcome to present his views in writting to Agency in the event there is any query regarding the issuance of a conditional of unsatisfactory inspection result. 6.1 Satisfactory 6.2 Conditional 6.3 Unsatisfactory 7. Shipment of the goods The seller is advised to check with Agency prior to shipment if the physical inspection result has not been received or there are any doubts concerning whether a Clean Report of Findings will be issued. 8. Final price verification and classification Based on the results of physical inspection and appropriate final documents, Agency finalises the price verification and the Agency opinion of Customs classification code. When the preliminary price verification has not resulted in any unresolved questions and the inspection result and other documents received are consistent with the preliminary documentation, Agency will not normally require any additional information. The main exception would be if the terms of sale require reference to prices at the date of shipment. 9. The Report of Findings 9.1 Types of Reports of Findings - Clean Reports of Findings(CRF) The Agency will issue a Clean Reports of Findings(CRF), or equivalent document, normally within two working days after receipt of the necessary correct final documents and a satisfactory result in all aspects of the inspection. - Discrepancy Report.

  • PDF

Prevalence and antimicrobial susceptibility of Brachyspira species in pigs in Korea

  • Lim, Suk-Kyung;Lee, Hee-Soo;Nam, Hyang-Mi;Cho, Yun Sang;Jung, Suk-Chan;Joo, Yi-Seok
    • Korean Journal of Veterinary Research
    • /
    • v.52 no.4
    • /
    • pp.253-257
    • /
    • 2012
  • The purpose of this study was to investigate the prevalence of Brachyspira species and antimicrobial susceptibility of Brachyspira (B.) hyodysenteriae isolates in Korea. A total of fifty-five Brachyspira species were isolated; five (1.0%) beta-hemolytic Brachyspira species and 50 (10.4%) weak hemolytic Brachyspira species from 116 different diarrheic pig samples and 367 apparently normal pig samples. In farm level, beta hemolytic and weak hemolytic Brachyspira species were detected in 7.4% (5/68) and 19.1% (13/68) of tested pig farms, respectively. By phenotypic and genotypic characterization, all beta hemolytic Brachyspira isolates was classified as group I (B. hyodysenteriae), whereas weak hemolytic Brachyspira species isolates were group III (B. innocens or B. murdochii). B. hyodysenteriae isolates showed high level of minimum inhibition concentrations to macrolide antimicrobials. This study shows that the prevalence of pathogenic B. hyodysenteriae in pigs is low but antimicrobial resistance of the pathogens is high in Korea. This is the first report of the prevalence of Brachyspira group III and antimicrobial susceptibility of B. hyodysenteriae in pigs in Korea. Our results could provide basic data for the management and treatment guidelines of Brachyspira infection.

Development of Automated Surface Inspection System using the Computer V (컴퓨터 비젼을 이용한 표면결함검사장치 개발)

  • Lee, Jong-Hak;Jung, Jin-Yang
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.668-670
    • /
    • 1999
  • We have developed a automatic surface inspection system for cold Rolled strips in steel making process for several years. We have experienced the various kinds of surface inspection systems, including linear CCD camera type and the laser type inspection system which was installed in cold rolled strips production lines. But, we did not satisfied with these inspection systems owing to insufficient detection and classification rate, real time processing performance and limited line speed of real production lines. In order to increase detection and computing power, we have used the Dark Field illumination with Infra_Red LED, Bright Field illumination with Xenon Lamp, Parallel Computing Processor with Area typed CCD camera and full software based image processing technique for the ease up_grading and maintenance. In this paper, we introduced the automatic inspection system and real time image processing technique using the Object Detection, Defect Detection, Classification algorithms. As a result of experiment, under the situation of the high speed processed line(max 1000 meter per minute) defect detection is above 90% for all occurred defects in real line, defect name classification rate is about 80% for most frequently occurred 8 defect, and defect grade classification rate is 84% for name classified defect.

  • PDF

Determining factor about the regulation compliance of inspection on harmful machine, instrument and equipment (위험기계.기구 및 설비 검사의 규제 순응 결정 요인)

  • Yi, Kwan-Hyung;Oh, Ji-Young;Rhee, Kyung-Yong
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.77-84
    • /
    • 2007
  • This study was planned to investigate what the main factor of the regulation compliance of inspection on harmful machine, instrument and equipment by industrial safety and health act is. This study subject was composed of three groups as employers, employees of manufacturing and using the harmful machine and safety inspectors. Manufacturing workplace were 236 places, using workplace were 201 places and the safety inspectors were 100 people. The study subject was sampled by stratified random sampling considering the type of harmful Machine. Data for analysis is collected from each sample using interview with structured questionnaires. Compliance is measured by 2, 3, and 4 point scale composed by 8 sub items such as general perception, understanding, clearness, necessity, relevancy, implementation, penalty, and general compliance of the regulation. The level of 8 items of employer's compliance are not differentiated among three groups. The determining factors for inspection observance of the workplace using the harmful Machine were understanding, penalty and cognized compliance. The determining factors for inspection observance of the workplace manufacturing the harmful Machine were understanding and object conformity. These results show that the strategy to adapt the regulated group to inspection regulation will be the elevation of understanding for regulation first of all.

Height & Position Control of a Power Line Inspection Robot Using Various Sensors (다양한 센서를 이용한 배전선 점검 로봇의 높이 및 자세제어)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.2
    • /
    • pp.169-175
    • /
    • 2009
  • A new wire detection algorithm for power line inspection by a mobile robot has been proposed in this paper. There have been a lot of studies in order to support the high-quality electric power. For the high-quality power supply, it is necessary to investigate the power lines and insulators before the lines or insulators were disconnected or damaged. Although Korea Electric power Corp. has made many efforts for the quality improvement, it is not enough to inspect all the power lines by human inspectors. According to this problem, it is decided to replace the human operators by the power line inspection robot. When the robots are used for the inspection, there could be several advantages, for example, the working efficiency and the prevention of accident. And also the shortage of human power for dangerous jobs can be resolved. In this paper, as a part of the development of power line inspection robot, DICRO, the sensor fusion and fuzzy control algorithms are developed to detect the wire and slope of the wire. The effectiveness of the proposed algorithms is proved by the real experiments with DICRO which is under development so far.