• Title/Summary/Keyword: airflow

Search Result 761, Processing Time 0.023 seconds

Experimental and Numerical Research on the Airflow Inside Asymmetric Nasal Cavities (비대칭 비강 내 공기유동에 관한 실험 및 수치해석적 연구)

  • Kim, Sung-Kyun;Park, Joon-Hyung;Leim, Huynh Quang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.749-754
    • /
    • 2010
  • Knowledge of the characteristics of airflow in nasal cavities is essential to understand the physiological and pathological aspects of nasal breathing. In our laboratory, a series of experimental investigations on the nasal airflow was conducted; airflow in models of normal and deformed nasal cavities under both constant and periodic flow conditions was studied by PIV. Some of the patients with asymmetric nasal cavities experience pain or discomfort, while other patients with asymmetric nasal cavities do not experience pain. Airflows inside asymmetric nasal cavities with and without obstructions due to a bent nasal septum are investigated both experimentally by PIV and numerically by using the general-purpose FVM code in order to determine the reason for the above-mentioned discrepancy. The comparisons between two cases are tried. Heat and humidity distribution are investigated numerically.

An Aerodynamic Study of Velopharyngeal Closure Function in Cleft Palate Patients (구개열 환자의 비인강폐쇄 기능에 대한 공기역학적 연구)

  • Ahn, Tae-Sub;Yang, Sang-Ill;Shin, Hyo-Keun
    • Speech Sciences
    • /
    • v.1
    • /
    • pp.237-259
    • /
    • 1997
  • Cleft Palate speech appears to have hyper/hyponasality with velopharyngeal insufficiency and articulation disorders. Previous studies on Cleft Palate speech have shown that speech tends to have lower airflow and air pressure. To examine the aerodynamic characteristics of Cleft Palate speech, Aerophone II Voice function Analyzer was used. We measured sound pressure level, airflow, air pressure and glottal power. Three Cleft Palate adults and five normal adults participated in this experiment. The test words are composed of: (1) the sustained vowel /o/ (2) /CiCi/, where C is one of three different stop consonants in Korean (3) /bimi/. Subjects were asked to produce /bimi/ five times without opening their lips. All the data was statistically tested by t-test for Cleft Palate patients before operation groups and control groups and paired t-test for Cleft Palate patients before and after operation groups. The results were as follow: (1) Cleft Palate patients generally speak with incomplete oral closure and lower oral air pressure. As a result, the SPL of Cleft Palate before operation is 3 dB lower than control groups. (2) Airflow of Cleft Palate in phonation and articulation is lower than that of control groups. However, it increased after operation. Lung volume and mean airflow in phonation are significantly increased (p<0.05). (3) Although velopharyngeal function (velar opening rate) of Cleft Palate is poor in comparison with control groups, it was recovered after operation. In this event maximum flow rate and mean airflow rate are significantly increased (p<0.05). (4) Air pressure of Cleft Palate in speech is lower than that of control groups. In general, the air pressure of Cleft Palate increased after operation. In this event air pressure of glottalized consonant is significantly increased (p<0.04). (5) Glottal Power(mean power, mean efficient and mean resistant) of Cleft Palate patients is lower than that of control groups. But mean efficient and mean resistant of Cleft Palate patients increased significantly (p<0.05) after operation.

  • PDF

Evaluation of Internal through Analysis of Airflow and Ventilation of Coal Storage Shed (옥내저탄장 기류 흐름 및 환기량 분석을 통한 내부 유동 평가)

  • Jo, Hyun-Joung;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.334-342
    • /
    • 2022
  • The stringent air environment conservation act forced to build an indoor dome for coal storage. However, it causes some problems due to accumulation of fly ash and harmful substances inside. To solve this problem, this study analyzed the pattern of internal airflow and the amount of ventilation for an indoor coal yard. Overall, the airflow inside the indoor coal yard tended to move to the southwest facing the mountain. In addition, sea-breeze was blowing from the northern louver window facing the sea, where airflow was flowing in. The total flow rate flowing into the indoor coal yard was 918,691 m3/h, and the number of natural ventilation per hour was 0.6 times. Therefore, it is proposed to install a forced ventilation device at the location where internal air flow is concentrated.

Concentration variability of atmospheric radon and gaseous pollutants at background area of Korea between 2017 and 2018

  • Kim, Won-Hyung;Yang, Hyo-Sun;Bu, Jun-Oh;Kang, Chang-Hee;Song, Jung-Min;Chambers, S.
    • Analytical Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.32-40
    • /
    • 2022
  • The concentrations of radon in the atmosphere were measured at the Gosan site of Jeju Island during 2017-2018, in order to investigate the time-series variation characteristics and the dependency of airflow transport pathways. The mean 222Rn concentration was 2,480 mBq m-3, and its monthly concentration in November was 3,262 mBq m-3, more than twice as that in July (1,459 mBq m-3). The diurnal radon concentrations increased throughout the nighttime to the maximum (2,862 mBq m-3) at around 7 a.m., then gradually decreased throughout the daytime by the minimum (1,997 mBq m-3) at around 3 p.m. The seasonal and monthly variations of CO, NO2, O3 showed a roughly similar pattern to that of radon for the same period, as high in winter and low in summer. The cluster back trajectory analysis described that about 60 % of overall airflow pathways was influenced by the airflow from China. The concentrations of radon and gaseous pollutants were relatively high as the airflow was influenced by China continent, but comparatively much lower as influenced by the northern Pacific Ocean.

Simulation of the Kitchen and Bathroom Exhaust Systems in High-Rise Apartment Buildings (고층 아파트의 주방 및 욕실 배기 시스템 시뮬레이션)

  • 김영돈;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.996-1006
    • /
    • 2003
  • The objective of this study is to find major variables which influence the performance of kitchen and bathroom exhaust systems in high-rise apartment buildings. For this purpose, the influencing factors on the exhaust airflow rates from the kitchen or bathroom are identified and in every cases, which are made of combinations between the influencing factors, the exhaust airflow rates are calculated through the simulations. The results of the simulation show that the exhaust airflow rates from the kitchen and bathroom mainly depends on outdoor air temperature, number of floors, airtightness of the building envelope, fan on ratio, vertically connected to same shaft, exhaust fan capacity for kitchen or bathroom, roof ventilator capacity and shaft area for kitchen or bathroom exhaust.

Effect of Mandibular Reposition on Airway Resistance (하악의 위치 변화가 기도저항에 미치는 영향)

  • 최재갑;정태훈
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.65-73
    • /
    • 1998
  • This study evaluated whether substantial airflow resistance changes occurred by changing jaw position in normal and snoring subjects. A case-control design was utilized to assess group differences. Subjects included 11 snoring patients and 10 non-snoring subjects. Airway resistance was assessed using a whole body plethysmograph. Subjects in this study had their mouth opening standardized to a position of 7 mm of vertical separation and the resistance was measured under the following conditions; normal jaw position and 2/3 maximum protrusive jaw position. The results were as follows : 1. The airway resistance was higher in snoring group than in non-snoring group. 2. Both groups had a significant decrease in their airflow resistance upon jaw protrusion. In conclusion, these data document that airflow resistance can be significantly influenced by jaw positioning. Moving the jaw in a protrusive position produced reduction of resistance.

  • PDF

Reduction of Disk Vibration and PES Using a Disk Damper (HDD의 DISK 진동감쇠 및 PES 저감을 위한 Disk Damper의 설계와 그 해석)

  • 권정민;강성우;한윤식;황태연;구자춘
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.3
    • /
    • pp.201-207
    • /
    • 2004
  • High speed rotating airflow inside a HDD chamber causes sub-micron scale disk vibration that could generate significant TMR problems in most of current HDD products. Many publications are presented for the reduction of airflow excitation. One of the most effective methods widely adopted in high-end HDD products is SqueezeAir Bearing Plate (SABP). However, because of its tight assembly clearance between the damper and disk, this method could not be easily implemented in volume production. This article presents a disk damper design that is modified to be feasible for volume production by virtue of a new airflow modeling method.

RESISTANCE OF COFFEE BEANS AND COFFEE CHERRIES TO AIR FLOW

  • Nordin Irbrahim, M.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.886-895
    • /
    • 1993
  • Experimental were conducted to obtain information on the effect of airflow rates and bed depths on the resistance of coffee cherries and coffee beans available locally (Coffea Liberica). The airflow used were in the range of 0.06 to 0.6 cu. m/s-sq.m. The moisture content of the coffee cherries ranged from 10 % to 50% (wet basis) and that of coffee beans ranged from 12% to 30% )wet basis). Two methods of filling were used i.e. loose fill and packed fill. Pressure drops across the material bed in a vertical column were measured at several depths using inclined manometer. The pressure drop increased directly with air flow rate as well as bed depths. The effects of air flowrates and moisture contents on the resistance in terms of pressure drip per unit bed depth were analysed. The pressure drop per unit depth across the material bed varied slightly due to different depth. The resistance to airflow decreased with the increase in moisture content for loose fill. However, the effect of moisture content is not apparent for packed fill.

  • PDF

Influence of External Air Velocity for Tribological Characteristics between Sintered Friction Material and Disk (외부 공기속도 변화에 따른 소결마찰재와 디스크간 마찰특성)

  • Lee, Jong Seong;Lee, Hi Sung
    • Tribology and Lubricants
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • Cu-matrix sintered brake pads and low-alloy heat-resistant steel are commonly applied to basic brake systems in high-energy moving machines. In this research, we analyzed the tribological characteristics to determine the influence of the air velocity between the disk and pad. At a low brake pressure with airflow, the friction stability was decreased as a result of the lack of tribofilm formation at the disk surface. However, there were no significant changes in the friction coefficient under any of the test conditions. The wear rates of the friction materials were decreased with an increase in the airflow velocity. As a result, the airflow velocity influenced the friction stability, as well as the wear rate of the friction materials and disk, but not the friction coefficient.

Development of an Integrated Multizone Model for Indoor Air Environment Prediction (실내공기환경 예측을 위한 통합 다구획 모델의 개발)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.17 no.9
    • /
    • pp.993-1003
    • /
    • 2008
  • Interior space in most buildings is divided into several zones. The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. An integrated multizone model to predict these environmental factors simultaneously was developed. Also, a computer program for this model was written by the language of VISUAL BASIC. The proposed model was applied to a apartment with five rooms that had been tested by Chung. Comparison of predicted results by this study with measured results by Chung showed that their variations were within 14% for airflow rates, 1% for temperatures, 12% for humidities, and 5% for concentrations. It was seen that the opening operation schedule of building has a significant effect on the air moisture md contaminant removal. Thus, this model may be available for predicting the indoor air environment and may be contributed to design the ventilation plan for controling of indoor air quality.