Browse > Article

Simulation of the Kitchen and Bathroom Exhaust Systems in High-Rise Apartment Buildings  

김영돈 (서울대학교 대학원 건축학과)
김광우 (서울대학교 건축학과)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.15, no.12, 2003 , pp. 996-1006 More about this Journal
Abstract
The objective of this study is to find major variables which influence the performance of kitchen and bathroom exhaust systems in high-rise apartment buildings. For this purpose, the influencing factors on the exhaust airflow rates from the kitchen or bathroom are identified and in every cases, which are made of combinations between the influencing factors, the exhaust airflow rates are calculated through the simulations. The results of the simulation show that the exhaust airflow rates from the kitchen and bathroom mainly depends on outdoor air temperature, number of floors, airtightness of the building envelope, fan on ratio, vertically connected to same shaft, exhaust fan capacity for kitchen or bathroom, roof ventilator capacity and shaft area for kitchen or bathroom exhaust.
Keywords
Kitchen and bathroom exhaust; Network model; High-rise apartment building;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Coping with air pressure problems in tall buildings /
[ Tamblyn,R.T. ] / ASHRAE Transaction
2 Unification and Improvement of Energy Efficiency Code for Buildings and Houses /
[ Ministry of Commerce, Industry and Energy ] / 1998-E-BD04-P-32
3 A study on Prediction Model of Ventilation Performance for Multi-Family Housings using Airflow Analysis /
[ Lee,Y.G. ] / Ph.D. thesis, Yonsei University
4 /
[ SAREK ] / SAREK Handbook Vol. 4 Sanitary · Fire Protection and Environment
5 Ventilation system of high-rise apartment bulidings /
[ Kim,S.G. ] / Magazine of SAREK
6 A Study for the improvement and performance test of common exhaust duct through kitchen on high rise apartment house /
[ Kim,I.K. ] / Daewoo Construction Technology Report
7 /
[ ASHRAE ] / ASHRAE Duct Fitting Database
8 Input Data for Multizone Airflow and IAQ Analysis /
[ Persily,A.K.;Ivy,E.M. ] / NISTIR 6585
9 /
[ ARHRAE ] / ARHRAE Handbook Fundamentals
10 /
[ Walton,G.N.;Dols,W.S. ] / CONTAMW 2.0 User Manual, NISTIR 6921
11 Performance of a kitchen ventilation system with supplementary supply and exhaust air /
[ Kang,Y.M.;Han,H.T. ] / Proceedings of the SAREK 2001 Summer Annual Conference (Ⅱ)
12 /
[ National Environmental Balancing Bureau ] / Testing Adjusting Balancing Manual for Technicians