• Title/Summary/Keyword: airborne source

Search Result 105, Processing Time 0.025 seconds

Airborne infection risk of respiratory infectious diseases and effectiveness of using filter-embeded mechanical ventilator and infectious source reduction device such as air cleaner (실내 공간에서의 호흡기 감염병 공기전파감염 위험도와 공기정화장치(필터 임배디드 기계식 환기설비 및 공기청정기 등 실내 감염원 저감 장치) 사용에 따른 효율)

  • Park, Sungjae;Park, Geunyoung;Park, Dae Hoon;Koo, Hyunbon;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.73-94
    • /
    • 2020
  • Particulate infectious sources, including infectious viruses, can float in the air, causing airborne infections. To prevent indoor airborne infection, dilution control by ventilation and indoor air cleaners are frequently used. In this study, the risk of airborne infection by the operation of these two techniques was evaluated. In case of dilution control by ventilation, a high efficiency air filter was embedded at the inlet of supply air. In this study, infectious source reduction devices such as indoor air cleaner include all kinds of mechanical-filters, UV-photo catalysts and air ionizers through which air flow is forced by fans. Two mathematical models for influenza virus were applied in an infant care room where infants and young children are active, and the risk reduction efficiency was compared. As a result, in the case of individually operating the ventilator or the infectious source reduction device, the airborne infection risk reduction efficiencies were 55.2~61.2% and 53.8~59.9%, respectively. When both facilities were operated, it was found that the risk of airborne infection was reduced about 72.2~76.8%. Therefore, simultaneous operation of ventilation equipment and infectious source reduction device is the most effective method for safe environment that minimizes the risk of airborne infection of respiratory infectious diseases. In the case of a space where sufficient ventilation operation is difficult, it was found that the operation of an infectious source reduction device is important to prevent the spread of infectious diseases. This study is meaningful in that it provides an academic basis for strategies for preventing airborne infection of respiratory infectious diseases.

The Use of Vibro-acoustical Reciprocity to Estimate Source Strength and Airborne Noise Synthesis (구조-음향 상반성 원리를 이용한 공기기인 소음원의 강도 추정 및 소음 합성)

  • Kim, Yoon-Jae;Byun, Jae-Hwan;Kang, Yeon-June;Hong, Jin-Chul;Kwon, O-Jun;Kang, Koo-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.1
    • /
    • pp.42-49
    • /
    • 2009
  • In this paper, an alternative method was introduced to conduct a transfer path analysis for airborne noise. The method used the transfer function matrix composed of acoustic transfer functions that are referenced by the input voltage of a calibration source. A calibration factor which is converting a virtual voltage to source strength was deduced by vibro-acoustical reciprocity theorem. The calibration factor is then multiplied to the virtual input voltage to estimate the operational source strength. Three loudspeakers were used to noise sources of acrylic half car model. The method was applied to airborne noise transfer path analysis of the half car. The estimated source strength by transfer path analysis was compared the deduced source strength by vibro-acoustical reciprocity to verify the method.

Ground-Platform Sensor Position Optimization Based Hybrid Time Difference of Arrival Method for Airborne Emitter (Hybrid TDOA 알고리즘 기반의 Airborne Emitter 위치탐지를 위한 Ground-Platform 센서의 위치 최적화)

  • Park, Jin-Oh;Lee, Woo-Seok;You, Byung-Sek;Kook, Chan-Ho;Chung, Jae-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.886-893
    • /
    • 2010
  • This paper considers the problem of time difference-of-arrival(TDOA) source localization when the TDOA and angle of arrival(AOA) measurements from an airborne emitter source are subject to ground-platform sensor position. The optimization of sensors' position is a challenging problem and a solution with good localization accuracy has yet to be found. This paper proposes an estimator that can achieve these purposes and provides optimized sensor position for good localization accuracy using the proposed estimator. The developed algorithm and sensor position are then examined under the special case of a single airborne source. The theoretical developments are supported by simulations.

Prediction of Interior Noise Caused by Tire Based on Sound Intensity and Acoustic Source Quantification (공기 기인 소음 분석과 음향 인텐시티법을 이용한 타이어에 의한 실내 소음 예측)

  • Shin, Kwang-Soo;Lee, Sang-Kwon;Hwang, Sung-Uk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.315-323
    • /
    • 2013
  • Tire noise is divided into a road noise(structure-borne noise) and a pattern noise(air-borne noise). Whilst the road noise is caused by the structural vibration of the components on the transfer path from tire to car body, the pattern noise is generated by the air-pumping between tire and road. In this paper, a practical method to estimate the pattern noise inside a passenger car is proposed. The method is developed based on the sound intensity and airborne source quantification. Sound intensity is used for identifying the noise sources of tire. Airborne source quantification is used for estimating the sound pressure level generated by each noise source of a tire. In order to apply the airborne source quantification to the estimation of the sound pressure, the volume velocity of each source should be obtained. It is obtained by using metrics inverse method. The proposed method is successfully applied to the evaluation of the interior noises generated by four types of tires with different pattern each other.

Assessment of Airborne Microorganisms in a Swine Wastewater Treatment Plant

  • Kim, Ki-Youn;Ko, Han-Jong;Kim, Daekeun
    • Environmental Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.211-216
    • /
    • 2012
  • Quantification of the airborne microorganisms (bacteria and fungi) at a swine wastewater treatment plant was performed. Microbial samples were collected at three different phases of the treatment process over a 1-yr period. Cultivation methods based on the viable counts of mesophilic heterotrophic bacteria and fungi were performed. The concentrations of airborne bacteria ranged up to about $5{\times}10^3$ colony-forming unit (CFU)/$m^3$, and those of airborne fungi ranged up to about $9{\times}10^2CFU/m^3$. The primary treatment (e.g., screen, grit removal, and primary sedimentation) was found to be the major source of airborne microorganisms at the site studied, and higher levels of airborne bacteria and fungi were observed in summer. High levels of the respirable bioaerosol (0.65 to $4.7{\mu}m$ in size) were detected in the aeration phase. Among the environmental factors studied, temperature was strongly associated with fungal aerosol generation (with a Spearman correlation coefficient of 0.90 and p-value <0.01). Occupational biorisks are discussed based on the observed field data.

Identification of Airborne-noise Source and Analysis for Noise Source Contribution of a GDI Engine Using Sound Intensity Method (음향 인텐시티법을 이용한 GDI 엔진 소음원 규명 및 소음 기여도 분석에 관한 연구)

  • Kim, Byung-Hyun;Lee, Sang-Kwon;Yoon, Joon-Seok;Shin, Ki-Chul;Lee, Sang-Jik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.985-993
    • /
    • 2012
  • In this paper, a new method is proposed to estimate the sound pressure generated from gasoline direct injection (GDI) engine. There are many noise sources as much as components in GDI engine. Among these components, fuel pump, fuel injector, fuel rail, pressure pump and intake/exhaust manifolds are major components generated from top of the engine. In order to estimate the contribution of these components to engine noise, the total sound pressure at the front of the engine is estimated by using airborne source quantification (ASQ) method. Airborne source quantification method requires the acoustic source volume velocity of each component. The volume velocity has been calculated by using the inverse method. The inverse method requires many tests and has ill-condition problem. This paper suggested a method to obtain volume velocity directly based on the direct measurement of sound intensity and particle velocity. The method is validated by using two known monopole sources installed at the anechoic chamber. Finally the proposed method is applied to the identification and contribution of noise sources caused by the GDI components of the test engine.

A Study on the Quantitative Analysis of SO$_2$ Dry Deposition in the Northeastern Asia (동북아 지역에서의 SO$_2$ 건성 침적에 관한 정량분석)

  • 홍민선;김순태;이동섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.3
    • /
    • pp.231-241
    • /
    • 1997
  • A tracer model was applied in the Far East Asia to investigate the dry deposition rates of air pollutants on Korean Peninsula originated from different countries including China and Japan. Wind direction was chosen to predict the maximum deposition rates and SO$_2$ was chosen as a tracer to estimate the source strength. Model simulation shows that inflow, deposition and airborne ratios of China-originated SO$_2$ were 50%, 8% and 30%, respectively, at most. Also it was found that deposition, outbounded and airborne ratios of Korea-originated SO$_2$ were 15~77%, 8~75%, and 3~30%, respectively Model simulation also shows that inflow, deposition and airborne ratios of Kyushu-originated SO$_2$ were, 30~45%, 8~14% and 20~25%, respectively. This study shows that tracer model can be applied on the estimation of air pollutants partitioning in regional scale and that more sophisticated modules and schemes can be developed and applied to better predict the transboundary amounts of air pollutants in this region.

  • PDF

Properties on the Airborne Chlorides of Offshore Bridges on the Western/Southern Coast in South Korea (국내 서/남해안 해상교량의 월별, 높이별 비래염분량 특성)

  • Jung, Jahe;Min, Jiyoung;Lee, Binna;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.59-67
    • /
    • 2022
  • In this study, the monthly airborne chlorides flying into the offshore bridges were investigated depending on the sea level. The target structures were 9 bridges located on the western and southern coast of South Korea. The airborne chlorides were measured at different sea levels on each bridge every month during 1 year. The results showed that the strongest seasonal wind from the northwest in winter expecially have led increase of the airborne chlorides, and its effect was more significant in the western coast than the southern coast. It was also found that the airborne chlorides declined with the increase of sea level. Three types of curves were suggested for analyzing the decrease trend with the sea level, based on the airborne chlorides at the lowest measurement height of main tower. The trend was varied depending on the sea area, and even in the same sea area, the local topographic condition affected the airborne chlorides. It means that the location and local topography should be considered simultaneously for durability management in the framework of the chloride source, and then the influence of the chloride source should be classified, e.g. safe and dangerous. From these results, it is expected that it could be used as baseline data for the evaluation of the deterioration environment in the Detailed guidelines for safety and maintenance of facilities [Performance evaluation]_Bridge.

Autonomous Unmanned Flying Robot Control for Reconfigurable Airborne Wireless Sensor Networks Using Adaptive Gradient Climbing Algorithm (에어노드 기반 무선센서네트워크 구축을 위한 적응형 오르막경사법 기반의 자율무인비행로봇제어)

  • Lee, Deok-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.6 no.2
    • /
    • pp.97-107
    • /
    • 2011
  • This paper describes efficient flight control algorithms for building a reconfigurable ad-hoc wireless sensor networks between nodes on the ground and airborne nodes mounted on autonomous vehicles to increase the operational range of an aerial robot or the communication connectivity. Two autonomous flight control algorithms based on adaptive gradient climbing approach are developed to steer the aerial vehicles to reach optimal locations for the maximum communication throughputs in the airborne sensor networks. The first autonomous vehicle control algorithm is presented for seeking the source of a scalar signal by directly using the extremum-seeking based forward surge control approach with no position information of the aerial vehicle. The second flight control algorithm is developed with the angular rate command by integrating an adaptive gradient climbing technique which uses an on-line gradient estimator to identify the derivative of a performance cost function. They incorporate the network performance into the feedback path to mitigate interference and noise. A communication propagation model is used to predict the link quality of the communication connectivity between distributed nodes. Simulation study is conducted to evaluate the effectiveness of the proposed reconfigurable airborne wireless networking control algorithms.