• 제목/요약/키워드: airborne

검색결과 1,718건 처리시간 0.025초

유리섬유 단열재 제조업 근로자의 공기중 유리섬유 폭로 특성 및 평가 방법에 관한 연구 (Characterization and Evaluation of Worker s Exposure to Airborne Glass Fibers in Glass Wool Manufacturing Industry)

  • 신용철;이광용;박천재;이나루;정동인;오세민
    • 한국환경보건학회지
    • /
    • 제22권2호
    • /
    • pp.43-57
    • /
    • 1996
  • To characterize worker's exposure to glass fibers, to find the correlation between airborne total dust concentrations and fiber concentrations and to recommend an appropriate evaluation method for worker's exposure to fibrous dusts in glass wool industry, we carried out this study. Average respirable fiber levels at five factories were 0.013-0.056 f/cc, and fairly below the OSHA PEL, 1 f/cc. A factory showed the lowest airborne fiber level, 0.013 f/cc, which was different significantly from those of other factories of which average fiber concentration was 0.046 f/cc. The cutting and grinding operations of insulation products resulted in higher airborne fiber cocentrations than any other processes(p<0.05). To characterize airborne fiber dimension, fiber length and diamter were determined using phase contrast microscope. The geometric means of airborne fiber lengths were $42-105 \mu m$. One factory had airborne fibers whose length distribution(GM = $105 \mu m$) was different from those of other factories(GM = $42-50 \mu m$). The percentages of respirable fibers less thinner than 3 gm were 38.9-90.9% at four factories, and two factories of them had the higher percentages than others. The findings explain for variation of airborne fiber diameters between factories. On the other hand, between the processes were the difference of fiber-length distributions observed. The cutting and grinding operations showed shorter fiber-length distributions than the fiber forming one. However, fiber-diameter distributions or respirable fiber contents were similar in all processes. The airborne fiber concentrations and the dust concentrations had relatively weak correlation(r=0.25), thus number of fibers couldn't be expected reliably from dust amount. Fiber count is appropriate for assessing accurate exposures and health effects caused by fibrous dusts including glass fibers. Ministry of Labor have established occupational exposure limit to glass fibers as nuisiance dust, but should establish it on the basis of respirable fiber concentration to provide adequate protection for worker's health

  • PDF

종합병원의 실내공기에 분포하는 부유 세균과 진균의 입경별 종류와 특성 (Size-based Characteristics of Airborne Bacteria and Fungi Distributed in the General Hospital)

  • 김기연;이창래;김치년;원종욱;노재훈
    • 한국산업보건학회지
    • /
    • 제16권2호
    • /
    • pp.101-109
    • /
    • 2006
  • The objective of this study is to provide fundamental data for pertinent management of indoor air quality through investigating the size-based characteristics of bioaerosol distributed in the general hospital. Measurement sites are main lobby, ICU, ward and laboratory and total five times were sampled with six-stage cascade impactor. Based on the result of this study, concentrations of airborne bacteria and fungi were the highest in main lobby as followed by an order of ward, ICU and laboratory. Concentrations of airborne bacteria was generally higher than those of airborne fungi and the ratio of indoor and outdoor concentration of both exceeded 1.0 in all the measurement sites of the general hospital. The predominant genera of airborne bacteria identified in the general hospital were Staphylococcus spp.(50%), Micrococcus spp.(15-20%), Corynebacterium spp.(5-20%), and Bacillus spp.(5-15%). On the other hand, the predominant genera of airborne fungi identified in the general hospital were Cladosporium spp.(30%), Penicillium spp.(20-25%), Aspergillus spp.(15-20%), and Alternaria spp.(10-20%). In regard to size distribution of bioaerosol, the detection rate was generally highest on 5 stage($1.1-2.1{\mu}m$) for airborne bacteria and on 1 stage(>$7.0{\mu}m$) for airborne fungi. Cleanliness of facilities in the general hospital and condition of HVAC system should be monitored regularly to prevent indoor air contamination by airborne microorganisms.

공중화분에 의한 시정장애 현상의 물리적 및 화학적 특성 규명 (Physico-Chemical Characteristics of Visibility Impairment by Airborne Pollen)

  • 김경원
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.863-875
    • /
    • 2006
  • Intensive visibility monitoring was conducted to investigate physical and chemical characteristics of visibility impairment by airborne pollen. Light attenuation coefficients were optically measured by a transmissometer, a nephelometer, and an aethalometer. Elemental, ionic, and carbonaceous species were chemically analyzed on the filters collected by $PM_{2.5}$ and $PM_{10}$ samplers. Aerosol size distribution was analyzed using a cascade impactor during airborne pollen period. Airborne pollen count was calculated using a scanning electron microscope. Airborne pollen was emitted into the atmosphere in springtime and funker degraded visibility through its scattering and absorbing the light. Average light extinction coefficient was measured to be $211{\pm}36Mm^{-1}$ when airborne pollen was not observed. But it increased to $459{\pm}267Mm^{-1}$ during the airborne pollen period due to increase of average $PM_{2.5}$ and $PM_{10}$ mass concentration and relative humidity and airborne pollen count concentration for $PM_{10}$, which were measured to be $46.5{\pm}29.1{\mu}g\;m^{-3},\;97.0{\pm}41.7{\mu}g\;m^{-3},\;54.1{\pm}11.6%$, and $68.2{\pm}89.7m^{-3}$, respectively. Average light extinction efficiencies for $PM_{2.5}$ and $PM_{10}$ were calculated to be $5.9{\pm}0.9$ and $4.5{\pm}0.8m^2 g^{-1}$ during the airborne pollen period. Light extinction efficiency for $PM_{10}$ increased further than that for $PM_{2.5}$. The average light extinction budget by airborne pollen was estimated to be about 24% out of the average measured light extinction coefficient during the airborne pollen period.

국내외 공기감염 분야 연구동향 (Review of Recent Studies on the Airborne Infection)

  • 권순박;김창수
    • 한국입자에어로졸학회지
    • /
    • 제6권2호
    • /
    • pp.81-90
    • /
    • 2010
  • Several studies have suggested the possibility of airborne transmission of infectious diseases such as tuberculosis, pandemic influenza. because the number of patients increases explosively, if infectious disease had a high basic reproduction number, pharmaceutical interventions such as vaccination, chemoprophylaxis in the early stage of epidemic. Thus, non-pharmaceutical interventions such as mask-wearing, installing air cleaners, school closure are important to control and prevent the infectious diseases. However, the current technology on the mask, air cleaning, ventilation, and etc., seems to be not originated from the understanding of infection via airborne transmission. It is important to estimate the aerodynamic behavior of saliva droplets by coughing or speaking in order to understand the phenomena of airborne infection. In addition, the prediction of transmission of infectious diseases through the air is critical to prevent or minimize the damage of infection. In this review, we reviewed the recent studies on the airborne infection by focusing on the aerodynamic characteristics of saliva droplets and modeling of airborne transmission.

함정의 격실 소음도에 관한 통계적 조사 연구 (Statistical Investigation on Airborne Noise Levels of Navy Shipboard Compartments)

  • 김종철;박일권;조대승
    • 한국소음진동공학회논문집
    • /
    • 제13권8호
    • /
    • pp.637-644
    • /
    • 2003
  • Airborne noise is one of the considerable environmental factors for navy ship personnel who should accomplish their tasks in restricted ship spaces against adverse health effect of noise. However, it is difficult to find studies on actual condition of airborne noise for navy ships. In this study, we measured airborne noise levels at 379 compartments of 33 Korean navy ships. Using the measured data, we presented mean values and their standard deviations of measured noise levels with factors of ship type, compartment category, and operation mode. Additionally, we evaluated the mean value and cumulative probability of airborne noise levels of compartments with those of the US navy ships. These results can be rationally used in making the proper airborne noise criteria of the navy ship for the future.

Inactivation of Airborne E. coli and B. subtilis Bioaerosols Utilizing Thermal Energy

  • Lee, Yun-Ha;Lee, Byung-Uk
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권11호
    • /
    • pp.1684-1689
    • /
    • 2006
  • Airborne microorganisms, which are currently termed bioaerosols, have received attention owing to the harmful effects they have on human health. As the concern over airborne microorganisms grows, there also grows an urgent need to study and develop efficient methods for controlling them. In this study, thermal energy using a thermal tube was tested as a control method, mainly against airborne E. coli. For a comparison, B. subtilis var. niger spores were utilized in the experimentation. It was found that the widely known inactivation conditions for microorganisms were not adequate against airborne microorganisms. The experimental results demonstrated the need for extensive studies that should investigate adequate and economic conditions to control against airborne bacteria. In this study, thermal energy exposed by the thermal tube demonstrated an inactivation performance for controlling E. coli bioaerosols.

Local Detection of Road Using Mathematical Morphology On Airborne SAR Image

  • Yang, Jin-Hyun;Moon, Wooil-M.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.17-22
    • /
    • 2002
  • This paper is concerned with a local detection of road on an airborne SAR image. The roads can be characterized by their geometry and radiometry. Roads are assumed as linear, thin, and elongated objects that are darker than their surroundings on an airborne SAR image. With these assumptions, a series of morphological filters are applied and tested successively. This approach is simple and almost non parametric and has been successfully applied to an airborne SAR image.

  • PDF

인천항의 대기 중 비래염분량의 시설물별 특성 및 해안거리에 따른 감소량 추정 (Estimation of Reduction Rate of Airborne Chlorides base on Coastal Distance and Facilities in Incheon Port, South Korea)

  • 정자혜;이종석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.13-21
    • /
    • 2023
  • 본 연구에서는 인천항만 시설물의 대기 중 비래염분량을 조사하였다. 2021.9 ~ 2023.8월, 총 2년 동안 북항, 남항, 신항에 총 15개의 염분포집기를 설치하여 대기 중 비래염분량을 측정하고, 항만시설물과 측정환경에 따른 비래염분량의 분포 특징과, 해안거리에 따른 비래염분량의 감소 특성을 분석하였다. 그 결과, 북항, 남항, 신항의 월별 비래염분량 분포는 0.4 ~ 3.3 mdd로 유사하게 나타났으며, 해안선의 방향을 고려한 계절풍의 영향으로 북항과 남항은 겨울에, 신항은 여름에 비래염분량이 높게 나타났다. 측정환경에 따른 비래염분량의 특징으로는 동일 지역에서 내해보다 내륙에 위치하여 바다에서 부는 바람이 내해를 통과하여 지나가는 위치에 있는 지점에서 비래염분량이 높게 나타났다. 또한 동일지역에서 해안거리가 동일한 두 지점일지라도 지면으로부터 높이에 따라서 비래염분량에 차이가 있었다. 한편 간만대의 경우, 월별 비래염분량은 상부보다는 하부에서 현저히 높게 나타났으며, 예외적으로 상부의 비래염분량이 하부만큼 높은 기간은 최고조위와 조위차가 높은 특징이 있었다. 해안으로부터 거리에 따른 항별 비래염분량의 감소율식을 도출하였으며, 그 결과, 해안으로부터 멀어질수록 비래염분량의 감소율은 신항이 가장 크고, 남항이 가장 작게 나타났다.

한국인의 혈중 망간농도와 공기중 망간농도의 관련성 (Associations between Airborne Manganese and Blood Manganese in the Korean General Population according to KNHANES 2008-2009)

  • 정경식;이종대;김용배
    • 한국환경과학회지
    • /
    • 제22권12호
    • /
    • pp.1589-1598
    • /
    • 2013
  • The objective of this study was to evaluate associations between airborne manganese and blood manganese in a general population of South Korean adults. The concentrations of airborne manganese in total suspended particulate (TSP) were calculated from data obtained from ambient air-monitoring stations (AAMSs) located in South Korea. Blood manganese data obtained Korean National Health and Nutrition Examination Survey (KNHANES) using a rolling sampling design involving a complex, stratified, multistage, probability cluster survey of a representative sample of the non-institutionalized civilian population of South Korea. Airborne manganese geometric means was 46.10 $ng/m^3$, blood manganese geometric means were 1.19 ${\mu}g/d{\ell}$ for male and 1.40 ${\mu}g/d{\ell}$ for female. In multiple linear regression analysis of log transformed blood manganeseas a continuous variable on airborne manganese, after adjusting for covariates including gender, age, job, smoking and drinking status, education level, BMI (body mass index). Airborne manganese was positively associated with blood manganese with statistical significance. The present study confirms that airborne manganese is a possible contributor to the increase of blood manganese in the adult general population.

사료제조공장 내 공기 중 세균과 진균 분포에 관한 연구 (Distribution of airborne microorganism in the feedstuff manufacture factory)

  • 김기연;정연일;김치년;원종욱;노재훈
    • 한국산업보건학회지
    • /
    • 제17권4호
    • /
    • pp.335-342
    • /
    • 2007
  • The objective of the study is to investigate the distribution patterns of airborne bacteria and fungi in the feedstuff manufacture factory. The mean levels of airborne bacteria and fungi in the feedstuff manufacture factory were $113({\pm}18)cfu/m^3$ and $89({\pm}5)cfu/m^3$ for pelleting process and $198({\pm}5)cfu/m^3$ and $124({\pm}12)cfu/m^3$ for powdering process, respectively. The percentage of respirable and total concentration of airborne bacteria and fungi in the feedstuff manufacture factory ranged from 60% to 90% and were higher in pelleting process than powdering process. The ratio of indoor and outdoor airborne microorganism exceeded 1.0 regardless of types of feedstuff manufacture process. Based on the result of the study, there would be an association between environmental factors such as relative humidity and carbon dioxide and airborne microorganism's bioactivity.