• Title/Summary/Keyword: airborne

Search Result 1,724, Processing Time 0.025 seconds

A Study on Analysis of Component and the States of Measurement of Airborne Organic Solvents in Korea (우리나라의 공기중 유기용제 측정실태 및 성분분석에 관한 연구)

  • 원정일;신창섭
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.3
    • /
    • pp.139-149
    • /
    • 1999
  • This study was performed to investigate components of organic solvents and present statues of environmental measurements with official records of working environmental measurements of 4,181 workplaces in 3,280 workshops used airborne organic solvents. 1. The mean working hour of 4,181 workplace producing airborne organic solvents in 3,280 workshops was 437±28.7min, but the mean sampling time for measurement of airborne organic solvents was identified to be 254±28.8min. In 73.0% of 4,181 samples the sampling frequencys were Full-period, single sample measurement. 2. The total 54 components of organic solvents were measured in total airborne samples of 4,181 workplace in 3,280 workshops in both of first and second half-year. These were divided into 38 components, Group 1 substances (5 components), Group 2 substances (31 components) and Group 3 substances (2 components), regulated by the Industrial Safety and Health Law, and other 16 components without legal duty of working environment measurement. The most common component in each half-year was Toluene (84.8%, 88.2%), which was followed by Xylene (464.4%, 51.7%), Methyl ethyl ketone (31.1%, 34.4%), n-Hexane (22.7%, 27.8%) and Benzene (20.4%, 21.5%) in frequency. Of legal duty free components, Ethyl benzen, Trimethyl benzene and Pentane were frequently detected. In conclusion, these results show that the present legal classification system of organic solvents needs to revise. Also these results suggest that it must be necessary to analyze the component of airborne organic solvents mixture and to evaluate their effects on workers' health for the effective management of working environment in workshops treating with organic solvents.

  • PDF

A Study on Airborne Microorganism in Hospital (일부 병원 실내에서의 공기중 미생물 오염에 관한 연구)

  • Jung, Sun Hoi;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.231-241
    • /
    • 1998
  • To assess biological indoor air quality in hospital, concentrations of viable airborne microbes were determined at intensive care unit(ICU), patient room (PR), outpatient waiting room(OPWR) in hospitals of large(1000 beds), middle(500 beds), small(100 beds) hospitals, respectively. Gram positive bacteria, gram negative bacteria, fungi were sampled using suctional sampling method by RCS sampler (Reuter centrifugal air sampler) and RCS GK-A agar plate. In gram positive bacteria groups, CNS(Coagulase Negative Staphylococcus), Micrococcus, Lactobacillus, S. aureus, Enterococcus, St. viridans identified. In gram negative bacteria groups, A. baumannii, Kl. peumoniae and E. coli were identified, and Penicillium was identified in fugi groups. Results of the study were as follows. 1. The highest concentrations of airborne microbes was $971CFU/m^3$ at 5:00 PM in small hospital patient room, and average concentrations of airborne microbes in large, middle and small hospitals were $282CFU/m^3$, $289CFU/m^3$ and $625CFU/m^3$, respectively. Average concentrations of airborne microbes in office(control) was $90CFU/m^3$. Thus, the small hospital showed the worst condition. 2. Representatives of 8 different genera were identified in 150 samples. The most frequently isolated organisms were Staphylococcus (73.0%), Micrococcus (20.7%) and Lactobacillus (4.7%), respectively. Pathogenic microbes isolated were A. baumannii, E. coli, Enterococcus, Kl. peumoniae, S. aureus, St. viridans and Penicillium as fungi. In office, no pathogenic microbes were identified. Average concentrations of airborne pathogenic microbes in large, middle and small hospital were $5CFU/m^3$ (2%), $11CFU/m^3$ (4%) and $12CFU/m^3$ (2%), respectively. Thus, condition in a large hospital was better than those in a middle and a small hospital.

  • PDF

Assessment of Airborne Bacteria and Particulate Matters Distributed in Seoul Metropolitan Subway Stations (서울시 일부 지하철역 내 분포하는 부유 세균 및 입자상 오염물질 평가)

  • Kim, Ki-Youn;Park, Jae-Beom;Kim, Chi-Nyon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.254-261
    • /
    • 2006
  • In activity areas of subway workers and passengers in Seoul metropolitan subway lines 1-4, mein concentrations of airborne bacteria were relatively higher in workers' bedroom and station precinct whereas concentrations of particulate matters, $PM_{10}$ and $PM_{2.5}$, were relatively higher in platform, inside train and driver's seat as compared with other activity areas. This result indicates that little correlation between airborne bacteria and particulate matters was found, which assumed that most airborne particulate matters distributed in subway consisted of mainly inorganic dust like a metal particles. Mean concentrations of $PM_{10}$ and $PM_{2.5}$ in station precinct and platform exceeded the threshold limit value ($PM_{10}:150{\mu}g/m^3,\;PM_{2.5}:65{\mu}g/m^3$) but those in station office and ticket office were below it. The genera identified in all the activity areas of subway over 5% detection rate were Staphylococcus, Micrococcus, Bacillus and Corynebacterium, of which Staphylococcus and Micrococcus covered over 50% of total airborne bacteria and were considered as predominant genera distributed in subway.

Student Exposure to Airborne Dusts in Classroom of Middle Schools (중학교 학생들의 분진폭로에 관한 조사연구)

  • 이영길;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.13 no.2
    • /
    • pp.25-33
    • /
    • 1987
  • This study was carried out to evaluate student exposures to dust in classroom of middle schools. A total of four schools, such as two in an urban and two in a rural area, were selected for this study. In this study, airborne dust concentrations were measured during a period from July 8 to July 18, 1986. Additional measurements of dust concentrations were conducted from November 4 to 7, 1986 to compare the results by seasonal variation. The results of this study were as follows. 1. Respirable dust concentrations were measured by both filtration method (C mg/m$^3$) and Digital Aerosol Monitor (cpm) to calculate anexchange factor K. K- value was 0.159 as follows. $K=\frac{c}{cpm} = \frac{2.71}{17.09} = 0.159$ 2. In summer when windows were opened, the concentrations of airborne respirable dusts measured by filter sampling method were 0.54-1.37 mg/m$^3$ in the morning and 0.79-1.75 mg/m$^3$ in the afternoon. Thus, higher levels were indicated in the afternoon. Meanwhile, the concentrations of airborne respirable dusts measured in winter were approximately twice as high as those in summer. 3. The highest dust concentrations were determined in School D which is a coeducational school with classroom of concrete floor. Walking roads in School D were not paved and students did not wear indoor-shoes. Dust levels in School D were approximately twice as high as levels in School B. All of the measured dust levels in four schools exceeded Korean Standard for outdoor air, 0.3 mg/m$^3$ for 24 hours. Results by Digital Aerosol Monitor indicated that there was no significant difference in dust levels among grades. The concentration of airborne dusts in the classroom was 1.5-3.0 times higher than that in the hall way. The concentration of airborne dusts during recess was 1.3-1.6 times higher than that during class. In winter, the dust concentrations during clean-up exceeded the permissible exposure limit, 10 mg/m$^3$ (as total dusts), for occupational exposures. 4. The concentrations of total dusts measured in winter were 1.5-2.4 times higher than those of respirable dusts measured simultaneously.

  • PDF

An Examination of Blood Lead Levels in Thai Nielloware Workers

  • Decharat, Somsiri;Kongtip, Pornpimol;Thampoophasiam, Prapin;Thetkathuek, Anamai
    • Safety and Health at Work
    • /
    • v.3 no.3
    • /
    • pp.216-223
    • /
    • 2012
  • Objectives: The objectives of this study were to determine the lead levels in blood samples from nielloware workers, to determine airborne lead levels, to describe the workers' hygiene behaviors, and to ascertain and describe any correlations between lead levels in blood samples and lead levels in airborne samples. Methods: Blood samples and airborne samples from 45 nielloware workers were collected from nielloware workplaces in Nakhon Sri Thammarat Province, Thailand. Lead levels were determined by flame atomic absorption spectrometry (FAAS), at a wavelength of 283.3 nm. FAAS was used especially adequate for metals at relatively high concentration levels. Results: The geometric mean of the 45 airborne lead levels was 81.14 ${\mu}g/m^3$ (range 9.0-677.2 ${\mu}g/m^3$). The geometric mean blood lead level of the 45 workers was 16.25 ${\mu}g/dL$ (range 4.59-39.33 ${\mu}g/dL$). No worker had a blood lead level > 60 ${\mu}g/dL$. A statistically significantly positive correlation was found between airborne lead level and blood lead levels (r = 0.747, p < 0.01). It was observed that personal hygiene was poor; workers smoked and did not wash their hands before drinking or eating. It was concluded that these behaviors had a significant correlation with blood lead levels (p < 0.001). Conclusion: Improvements in working conditions and occupational health education are required due to the correlation found between blood leads and airborne lead levels.

A Study on Airborne Dust and Asbestos Concentrations in Subway Stations in Seoul Area (서울시 지하철 구내의 공기중 분진 농도에 관한 연구)

  • 백남원;박두용;장익선;신용철;이정인
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.2
    • /
    • pp.1-12
    • /
    • 1988
  • Airborne dust and asbestos fiber concentrations were determined in subway stations located in Seoul area. Two stations, such as Eulchiro 4-Ka Station of Line #2, constructed during a period of 1980-1984 and Hyehwa Station of Line #4, opened in 1985, were selected. The results of the study are as follows. 1. Daily time-weighted average (TWA) concentrations of airborne dusts from 07:00 to 20:00 hours in Line #2 and Line #4 were 0.43$\pm$0.08 mg/m$^3$ and 0.37$\pm$0.12 mg/m$^3$, respectively. Thus, the dust levels in Line #2 were significantly higher than the levels in Line #4 (p < 0.05). 2. Dust levels in the morning (07:00-11:00 hours), noon (11:00-16:00 hours) and in the evening (16:00-20:00 hours) in Line #2 were 0.47$\pm$0.17 mg/m$^3$, 0.37$\pm$0.08 mg/m$^3$, and 0.46$\pm$0.07 mg/m$^3$ respectively. Thus, dust levels in the morning and evening (i.e., during rush hours) were significantly higher than levels in the noon (p < 0.02). However, there was no such difference in dust levels by time in Line #4. 3. Airborne total dust concentrations were well below the occupational health standard of 10 mg/m$^3$, however, the levels were exceeding the ambient air standard recommended by the Korean Environment Administration. 4. All of airborne asbestos fiber concentrations were equal to or below 0.005 fibers/cc. The levels are within both occupational health standards and U.S. EPA criteria. 5. A consideration should be given to the improvements of cleaning methods (such as use of vacuum cleaning instead of brushing) and the existing ventilation (such as more air change and filtration of supply air) for a reduction of dust levels. 6. It is recommended that routine monitoring of airborne dusts and asbestos fibers be conducted because more dusts and asbestos fibers can be produced in the air due to the deterioration of facilities by age and water damage in future.

  • PDF

Characteristics of Bioaerosol Generation of Household Humidifiers by User Practices (가정용 가습기의 사용자 습관에 따른 실내공기 중 바이오에어로졸의 발생특성)

  • Kim, Ik-Hyeon;Kim, Ki Youn;Kim, Daekeun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.503-509
    • /
    • 2012
  • Objectives: This study was performed in order to evaluate the generation characteristics of airborne bacteria and fungi while operating a household humidifier, in consideration of user habits. Methods: Microbial samples were collected in a closed chamber with a total volume of 2.76 $m^3$, in which a humidifier was operated according to experimental strategies. A cultivation method based on the viable counts of mesophilic heterotrophic bacteria and fungi was performed. Experimental strategies were divided into three classes: the type of water in the water reservoir (tap water, cooled boiled water); the frequency of filling the reservoir (refill every day, no refill); and the sterilization method (sterilization function mode, humidifier disinfectants). Results: Significant increases in the concentration of airborne bacteria were observed while the humidifier was in operation. The concentration had increased to 2,407 $CFU/m^3$ by 120 hours when tap water filled the reservoir without any application of sterilization, while for cooled boiled water, it was merely 393 $CFU/m^3$ at a similar time point. Usages of disinfectant in the water tank were more effective in decreasing bioaerosol generation compared to sterilization function mode operation. Generation characteristics of airborne fungi were similar to those of bacteria, but the levels were not significant in all experiments. Calculated exposure factor can be used as an indicator to compare biorisk exposure. Conclusion: This study identified the potential for bioaerosol generation in indoor environments while operating a household humidifier. User practices were critical in the generation of bioaerosol, or more specifically, airborne bacteria. Proper usage of a humidifier ensures that any biorisks resulting from generated bioaerosol can be prevented.

The effect of repeated surface treatment of zirconia on its bond strength to resin cement

  • Maciel, Lucas Campagnaro;Amaral, Marina;Queiroz, Daher Antonio;Baroudi, Kusai;Silva-Concilio, Lais Regiane
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.291-298
    • /
    • 2020
  • PURPOSE. The aim of this study is to evaluate the influence of repeated surface treatments on wettability and surface roughness for zirconia surface and bond strength of zirconia-based ceramics to resin cement. MATERIALS AND METHODS. Seventy blocks (10 × 10 × 3 mm) of zirconia-based ceramics were fabricated and divided into two groups according to the surface treatments: (A) 110 ㎛ Al2O3 airborne-particle abrasion and (R) 110 ㎛ silica modified Al2O3 airborne-particle abrasion. At stage 2, each group was subdivided into 5 groups according to the surface retreatments: (a) 110 ㎛ Al2O3 airborne-particle abrasion, (r) 110 ㎛ silica modified Al2O3 airborne-particle abrasion, (D) diamond bur, (Da) diamond bur + 110 ㎛ Al2O3 airborne-particle abrasion, and (Dr) diamond bur + 110 ㎛ silica modified Al2O3 airborne-particle abrasion. Cylinders of self-adhesive resin cement were cemented onto each treated ceramic surface and subjected to micro-shear bond strength test. Additional specimens were prepared for roughness and wettability analyses. The data were subjected to t-test and One-way ANOVA followed by Tukey's post hoc test (α=.05). RESULTS. At stage 1, group R presented higher bond strength values than group A (P=.000). There was a statistically significant increase of bond strength at stage 2 for group A (P=.003). The diamond bur influenced the surface roughness, increasing the values (P=.023). Group R provided better wettability. Regardless of the applied surface treatment, most of failures were adhesive. CONCLUSION. The combination of application and reapplication of Rocatec Plus showed the best results of bond strength. Surface retreatment and recementation might be an indicated clinical strategy.

Evaluation of Environmental Circumstance Within Swine and Chicken Houses in South Korea for the Production of Safe and Hygienic Animal Food Products (일부지역 양돈장 및 양계장 공기중 박테리아, 진균, 내독소 농도)

  • Kim, Young-Hwan;Suh, Hyung-Joo;Kim, Jin-Man;Jung, Yeon-Hoon;Moon, Kyong-Whan
    • Food Science of Animal Resources
    • /
    • v.28 no.5
    • /
    • pp.623-628
    • /
    • 2008
  • This study was undertaken to determine the concentrations of airborne bacteria, fungi, particles, and endotoxin in swine and chicken houses. Six swine buildings and seven chicken houses were randomly selected in southern Gyonggi Province, South Korea. The geometric mean concentrations of airborne bacteria in swine and chicken houses were $2.7{\times}10^5\;CFU/m^3$ and $5.6{\times}10^7\;CFU/m^3$, respectively. The airborne bacteria concentrations in chicken houses were significantly higher than those of swine houses (p<0.05). The geometric mean concentration of airborne fungi in swine houses was $4.9{\times}10^3\;CFU/m^3$, which was higher than the value of $2.1{\times}10^3\;CFU/m^3$ found in chicken houses. The mean concentrations of airborne particles and endotoxin in swine houses were $3.48\;mg/m^3$ and $943.1\;EU/m^3$, and they were $15.43\;mg/m^3$ and $1,430.5\;EU/m^3$ in chicken houses, respectively. A significant difference between swine and chicken houses was found for total dust (p<0.05), but not for endotoxin. In this study, the concentrations of endotoxin in both swine and chicken houses as well as particles in chicken houses were high, and in about 50% of the samples exceeded the worker health safety levels of $614\;EU/m^3$ suggested in previous studies. These results may indicate a considerable respiratory hazard for workers in these environments.

A Study of Airborne Microbes in the NSICU According to Number of Persons Who Pass through Every Hour (일지역 신경외과 중환자실내의 통행량에 따른 낙하균 분석)

  • Park Hyoung-Sook;Kang In-Soon;Kim Jin-Wha;Eo Hyun-Ju
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.11 no.1
    • /
    • pp.41-48
    • /
    • 2004
  • Purpose: The purpose of this study was to analyze the colony count of airborne microbes contamination every hour in the Neurosurgical Intensive Care Unit (NSICU) in order to identify the relationship of colony count to person-visits. Method: Data were collected during from 11:00 a.m. September 5 to 11:00 a.m. September 6, 2002. This study used blood agar & nutrient agar and handtally counter (USA) for collection of airborne microbes and number of person-visits. Data was analyzed using the SPSSWIN 10.0 with means, Pearson correlation coefficient, and simple regression. Result: The result of this study are as follows. Total colony count of airborne microbes for 24 hours in the NSICU was 4,609. Total number of person-visits to the NSICU was 15,347. The highest scores fur the total colony count in different areas of the NSICU was the rear door, followed by the preparation room, and the front entrance, while the lowest count was in the isolation rooms. There was a statistically significant relationship between colony count and number of person-visits to the NSICU. The most frequently airborne microbes in the NSICU were Micrococcus, CNS, Staphylococcus Micrococcus, Aureus. Conclusion: These findings indicate that the number of person-visits in hospitals influences total colony count of airborne microbes. This study contributes to assessment of biological indoor air quality in hospital and in the development of an NSICU care plan.

  • PDF