• 제목/요약/키워드: air-water ratio

검색결과 848건 처리시간 0.023초

잠열 전달이 일어나는 얇은 익형주위의 천음속 습공기 유동에서의 마하수와 익형 두께비의 영향 (THE EFFECTS OF MACH NUMBER AND THICKNESS RATIO OF AIRFOIL ON TRANSONIC FLOW OF MOIST AIR AROUND A THIN AIRFOIL WITH LATENT HEAT TRANSFER)

  • 이장창
    • 한국전산유체공학회지
    • /
    • 제17권4호
    • /
    • pp.93-102
    • /
    • 2012
  • Once the condensation of water vapor in moist air around a thin airfoil occurs, liquid droplets nucleate. The condensation process releases heat to the surrounding gaseous components of moist air and significantly affects their thermodynamic and flow properties. As a results, variations in the aerodynamic performance of airfoils can be found. In the present work, the effects of upstream Mach number and thickness ratio of airfoil on the transonic flow of moist air around a thin airfoil are investigated by numerical analysis. The results shows that a significant condensation occurs as the upstream Mach number is increased at the fixed thickness ratio of airfoil($\epsilon$=0.12) and as the thickness ratio of airfoil is increased at the fixed upstream Mach number($M_{\infty}$=0.80). The condensate mass fraction is also increased and dispersed widely around an airfoil as the upstream Mach number and thickness ratio of airfoil are increased. The position of shock wave for moist air flow move toward the leading edge of airfoil when it is compared with the position of shock wave for dry air.

연직상향(鉛直上向) 사각충돌수분류(四角衝突水噴流)의 포화비등 열전달에 관한 연구 (A Study on Saturated Boiling Heat Transfer in Upward Rectangular Impinging Water Jet System)

  • 이종수;엄기찬;서정윤
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.395-403
    • /
    • 1991
  • The purpose of this investigation was to characterize nucleate boiling and burn-out heat flux for rectangular free jet with saturated water impinging perpendicularly and upward against a flat uniform heat flux surface. Heat flux measured for Reynolds number based on rectangular nozzle width and for aspect ratio. The result of nucleate boiling heat transfer was presented nondimensional experimental equation including Nusselt, Boiling, Subcooling, Reynolds and Weber number. The effect of aspect ratio of heated surface in the burn-out heat flux had not appeared distinctly. But for the same aspect ratio, burn-out heat flux increased linearly with increment of nozzle exit velocity.

  • PDF

Effect of Flow Direction on Two-Phase Flow Distribution of Refrigerants at a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.717-727
    • /
    • 2006
  • The present study experimentally investigated the effect of flow direction and other flow parameters on two-phase flow distribution of refrigerants at a T-junction, and also suggested a prediction model for refrigerant in a T-junction by modifying previous model for air-water flow. R-22, R-134a, and R-410A were used as test refrigerants. As geometric parameters, the direction of the inlet or branch tube and the tube diameter ratio of branch to inlet tube were chosen. The measured data were compared with the values predicted by the models developed for air-water or steam-water mixture in the literature. We propose a modified model for application to the reduced T-junction and vertical tube orientation. Among the geometric parameters, the branch tube direction showed the biggest sensitivity to the mass flow rate ratio for the gas phase, while the inlet quality showed the biggest sensitivity to the mass flow rate ratio among the inlet flow parameters.

Polystyrene Beads를 사용한 경량 폴리머 시멘트 모르타르의 기초적 성질 (Fundamental Properties of Lightweight Polymer-Cement Mortars Using Polystyrene Beads)

  • 이기원;신영수;이윤수;황진하
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.327-332
    • /
    • 2000
  • The objective of this study was to improve the defects of lightweight cement concrete by treating with redispersible polymer powders. The statistical relationships of water-cement ratios, contents of lightweight aggregates and polymer powers and be used for predicting the concrete strength. It was found that the varieties and techniques adopted in this experiment were capable of identifying the influence of various tested for air contents, flow test, water absorption, specific gravity, flexural and compressive strength. This study showed that fundamental properties were very affected by cement- lightweight aggregate ratio, polymer-cement ratio and water-cement ratio.

  • PDF

발수 처리한 ALC 분말이 유화처리 정제유지류(ERCO) 혼입 모르타르의 품질특성에 미치는 영향 (Effects of Water Repellency Treated ALC Powder on the Properties of Mortar Mixed with ERCO)

  • 이명호;박준희;김상섭;박재용;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.112-113
    • /
    • 2014
  • This study was done to resolve the air reduction in mortar when mixed with ERCO. Effects of the water repellent ALC powder due to its particle size and substitution ratio on the cement mortar with ERCO was analyzed. Results showed more water repellent ALC powder ensured more air but did not affect the size of particles. It was determined the compression was caused by more air and water added to achieve the flow. Therefore, substituting with water repellent ALC powder may compensate for the air reduction in mortar with ERCO. Other measures and approaches are needed in order to resolve the reduced strength.

  • PDF

암모니아-물 흡수식 냉각기의 동적 해석 (Dynamic Analysis of an Ammonia-Water Absorption Chiller)

  • 김병주
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.990-998
    • /
    • 2004
  • Dynamic behavior of an ammonia-water absorption system was investigated numerically. Thermal-hydraulic model for a single-effect 3 RT chiller was developed by applying transient conservation equations of total mass, $NH_3$ mass, energy and momentum to each component. Transient variations of system properties and transport variables were analysed during start-up operation. Numerical analyses were performed to quantify the effects of bulk concentration and charging ratio on the system performance in terms of cooling capacity, coefficient of performance, and time constant of system. For an absorption chiller considered in the present study, optimum charging ratio and bulk concentration were to found to exist, which resulted in the maximum cooling capacity and COP. The time constant increased as the charging ratio increased, but decreased with the increase of bulk concentration.

하천수 열원 열펌프 시스템의 성능 특성 및 경제성 평가 (Performance Characteristics and Economic Assessment of a River Water: Source Heat Pump System)

  • 박차식;정태훈;박홍희;김용찬
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.621-628
    • /
    • 2009
  • The objectives of this study are to analyze the performance of a river water-source heat pump and to carry out economic assessment for the heat pump. The COP of the river water-source heat pump was 3-21% higher than that of the air-source heat pump because river water provides stable operating temperature compared with air temperature throughout the year. The economic analysis was carried out by comparing the initial and operating cost of the river water-source heat pump with those of the conventional air-source heat pump. The ratio of the life cycle operating cost to the life cycle cost increased with the increase of building capacity. The payback period was found to be less than 3.5 years when the capacity of the river water-source heat pump was larger than 10 RT.

포틀랜드 시멘트 모르타르의 미세구조와 동결융해저항성에 대하여 (Microstructure and Freeze-Thaw Resistance of Portland Cement Mortars)

  • 이종호;장복기
    • 한국세라믹학회지
    • /
    • 제28권11호
    • /
    • pp.917-925
    • /
    • 1991
  • For the present experiment five Portland cement mortars are in order: mortars with two different water/ cement ratios (W/C=0.45 and 0.50, each having no chemical additive), and those with an additive such as superplasticizer, air-entraining agent or water-repelling agent. We fix the W/C ratio of mortars having additive so that their pastes can yield the same workability as that of the cement mortar of W/C=0.50 with no additive. It is shown that the freeze-thaw resistivity depends heavily on the characteristic of wide pores. Despite a good deal of wide pores, the air-entrained specimen shows a good freeze-thaw resistivity due to appropriate air-pores. And also the specimen with water-repelling agent, which proves to cause the microstructure to become hydrophobic, make good resistance to freeze-thaw cycles in spite of its high wide-porosity. Our suggestion is that the freeze-thaw durability of Portland cement mortar/concrete can be more effectively enhanced by using air-entraining agent or water-repelling agent, and simutaneously by taking proper measures against foaming and/or the increased tendency of wide-pore building due to additive.

  • PDF

Y-Jet 노즐에서의 혼합관 길이변화에 따른 분무특성 연구 (Change of Spray Characteristics with Mixing Port Length of Y-Jet Atomizers)

  • 송시홍;이상용
    • 대한기계학회논문집
    • /
    • 제18권11호
    • /
    • pp.3021-3031
    • /
    • 1994
  • Experiments have been performed to find out the effect of the mixing port length of Y-jet atomizers on the spray performance, using air and water as the test fluids. Water and air flow rates and drop sizes were measured at each injection pressure condition for different mixing port length. The air flow rate was almost unaffected by the change of the mixing port length. However, the water flow rate was relatively susceptible to the change of the mixing port length. The mixing point pressure was very much influenced by the mixing port length. Variations of spatial distribution of Sauter Mean Diameter (SMD, $D_{32}$) and the cross-section-averaged SMD ($D_{32,m}$) with different mixing port length and air/water mass flow rate ratio were examined. Generally, when the mixing port length was reduced, the mean drop size decreased and became spatially even.

회수수 안정화제 종류 및 혼입률 변화에 따른 시멘트 모르타르의 특성 (Properties of Cement Mortar according to the Kinds and Adding Ratio of Recycling Water-Stabilizing Agent)

  • 정덕우;김광화;이문환;이세현;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.477-480
    • /
    • 2003
  • This study discusses the fundamental properties of cement mortar with the kinds and adding ratio of stabilizing agent of recycled water. According to the results, fluidity and air content hardly make difference by the kinds and adding ratio of stabilizing agent. When recycled water is used, setting time is shortened slightly in comparison with plain mortar because of an increase of fine particle. And it is similar to the use of recycled water in the case of A, Band D(stabilizing agent), but shortened significantly in the case of C. Also, it does not show difference with variation of the adding ratio, but as the adding ratio increases, it approach to the value of plain mortar. When recycled water is used, compressive strength is similar to plain concrete, and it shows the larger value in order of D, C and A. As the adding ratio of stabilizing agent increases, it decreases at 3days, but increases at 7 and 28days. However, at the adding ratio of 0.5%, it decreases, instead. Length change ratio by drying shrinkage increases in the case of B in comparison with plain mortar, but is similar to plain mortar in the other stabilizing agent. As the adding ratio of stabilizing agent increases, it decreases, however, increases at the adding ratio of 0.5%

  • PDF