• 제목/요약/키워드: air-permeability

검색결과 589건 처리시간 0.028초

고정형 스크류 혼합 방식을 이용한 초속경 도막방수층 에어 셀 구조의 수증기투과성에 관한 연구 (A Stud on the Water Vapor Permeability of Air Cell Structure of Ultra Rapid Harding Membrane Waterproofing Using Fixed Screw Hybrid Method)

  • 김윤호;김현민;박진상;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.225-226
    • /
    • 2013
  • Existing polyurethane membrane waterproofing has been raised defects such as heaving. Therefore, We will be utilizing as the basic experimental data by the water vapor permeability test to the air cell structure of ultra rapid harding membrane waterproofing using the static mixing system in this study.

  • PDF

Optimization for Permeability and Electrical Resistance of Porous Alumina-Based Ceramics

  • Kim, Jae;Ha, Jang-Hoon;Lee, Jongman;Song, In-Hyuck
    • 한국세라믹학회지
    • /
    • 제53권5호
    • /
    • pp.548-556
    • /
    • 2016
  • Recently, porous alumina-based ceramics have been extensively applied in the semi-conductor and display industries, because of their high mechanical strength, high chemical resistance, and high thermal resistance. However, the high electrical resistance of alumina-based ceramics has a negative effect in many applications due to the generation of static electricity. The low electrical resistance and high air permeability are key aspects in using porous alumina-based ceramics as vacuum chucks in the semi-conductor industry. In this study, we tailored the pore structure of porous alumina-based ceramics by adjusting the mixing ratio of the starting alumina, which has different particle sizes. And the electrical resistance was controlled by using chemical additives. The characteristics of the specimens were studied using scanning electron microscopy, mercury porosimetry, capillary flow porosimetry, a universal testing machine, X-ray diffraction, and a high-resistance meter.

집진용 세라믹 필터의 제조 및 공기 투과 특성 (Preparation of Ceramic Foam Filter and Air Permeability)

  • 박재구
    • 한국대기환경학회지
    • /
    • 제16권4호
    • /
    • pp.381-388
    • /
    • 2000
  • Ceramic foam prepared with cordierite as a starting material by foam method was tested to evaluate the feasibility as a filter for the dust collection in hot gas. Two different types of agents Benzethonium chloride (BZTC, C27H42NO2Cl) and Sodium Lauryl Sulfate(SLS, CH3(CH2)11OSO3Na) were used as foaming agents in foaming process. Porosityof ceramic foam was about 80% and mean pore size were 100${\mu}{\textrm}{m}$ for SLS agent and 200 ${\mu}{\textrm}{m}$ for BZTC. It was observed that ceramic foam was composed of continuous macro-pore structure with opening windows interconnecting macro-pores. The surface of ceramic foam support of was coated with cordierite particles ranged from 20${\mu}{\textrm}{m}$ to 50${\mu}{\textrm}{m}$ Meso-pore size in the coating layer on ceramic foam was below 10${\mu}{\textrm}{m}$. While air permeability of the support increased with increasing macro-pore size coated ceramic filters showed a constant permeability without regard to the macro-pore size of the support. The permeabuilities of support varied in the range of 600$\times$10-13m2 to 1000$\times$10-13m2. For the case of coated ceramic filter it was about 200$\times$10-13m2. As a result of particle trapping test by using fly ash the particle removal efficiency was over the 99.9%.

  • PDF

The Effect of MnO2 Content on the Permeability and Electrical Resistance of Porous Alumina-Based Ceramics

  • Kim, Jae;Ha, Jang-Hoon;Lee, Jongman;Song, In-Hyuck
    • 한국세라믹학회지
    • /
    • 제54권4호
    • /
    • pp.331-339
    • /
    • 2017
  • Porous alumina-based ceramics are of special interest due to their outstanding mechanical properties and their thermal and chemical stability. Nevertheless, the high electrical resistance of alumina-based ceramics, due to the generation of static electricity, leads to difficulty in applying a vacuum chuck in the semi-conductor process. Therefore, development of alumina-based ceramics for applications with vacuum chucks aims to have primary properties of low electrical resistance and high air permeability. In this study, we tailored the electrical resistance of porous alumina-based ceramics by adjusting the amount of $MnO_2$ (with $TiO_2$ fixed at an amount of 2 wt%) and by using coarse alumina powder for high air permeability. The characteristics of the specimens were studied using scanning electron microscopy, mercury porosimeter, capillary flow porosimetry, universal testing machine, X-ray diffraction and high-resistance meter.

침엽수 원판(圓板)의 투과성 증진을 위한 저압증기폭쇄(低壓蒸氣爆碎)처리 효과 (The Effect of Law Pressure Steam Explosion Treatment on the Improvement of Permeability in the Softwood Disks)

  • 이남호;하야시 카즈오
    • Journal of the Korean Wood Science and Technology
    • /
    • 제25권3호
    • /
    • pp.37-42
    • /
    • 1997
  • This study was carried out to track the heated-air flows within the tree disk through measuring the distribution of wood temperatures during explosing the 7.5mm-thick Japanese cedar disk and to investigate the effects of the time for the first explosion cycle and the number of explosion cycles on the improvement of permeability of tree disk. If the tree disk are explosed when the temperatures of the shell and core of it are not equilibrium yet, all of the inflated airs in the shell after explosion don't flow out toward the autoclave and some of them flow into the core of which the air pressures are lower than those of the shell. It is very effective for the improvement of permeability of tree disk to make the first explosion cycle when the temperatures of the shell and the core equilibrate at the setting temperature of steam in the autoclave. The more tree disks were explosed under the same conditions of first explosion, the more their permeabilities were improved.

  • PDF

다공성 건축자재의 투습 및 통기성 분석에 대한 연구 (Analysis of Water-Vapor Permeance and Ventilation Property of the Porous Construction Materials)

  • 김종원;안영철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.754-757
    • /
    • 2008
  • To maintain the indoor air quality, many ventilation systems and technologies have been developed in the highly insulated and air tight buildings. In this study, a porous construction material, which is applicable to passive ventilation system, is developed and measured the performances of the permeability and the resistance of water vapor, and the dust collection efficiency. The average coefficient of water vapor permeability shows $3.6\;g/m^2{\cdot}h{\cdot}mmHg$, which is slightly higher than Hanji ($2.4{\sim}3.2\;g/m^2{\cdot}h{\cdot}mmHg$) and the average water vapor resistance factor shows $0.303\;g/m^2{\cdot}h{\cdot}mmHg/g$, which is slightly smaller than Hanji($0.309{\sim}0.315\;g/m^2{\cdot}h{\cdot}mmHg/g$). The pressure drop of the porous construction material is smaller than the HEPA filter and the minimum dust collection efficiency shows 82.8% in the range of $2{\sim}9\;cm/s$.

  • PDF

알루미늄 발포금속의 유효열전도도와 침투율의 측정 (Measurement of effective thermal conductivity and permeability on aluminum foam metal)

  • 백진욱;강병하;김서영;현재민
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.185-192
    • /
    • 1999
  • Effective thermal conductivities and pressure-drop-related properties of aluminum foam metals have been measured. The effects of porosity and cell size in the aluminum foam metal are investigated in detail. The porosity of the foam metal, considered in the present study, varies from 0.89 to 0.96 and the cell size from 0.65㎜ to 2.5㎜. The effective thermal conductivity is evaluated by comparing the temperature gradient of the foam metal with that of the thermal conductivity-known material. The pressure drop in the foam metal is measured by a highly precise electric manometer while air is flowing through the aluminum foam metal in the channel. The results obtained indicate that the effective thermal conductivities are found to be increased with a decrease in the porosity while the effective thermal conductivities ire little affected by the cell size at a fixed porosity. However, the pressure drop is strongly affected by the cell size as well as the porosity. It is seen that the pressure drop is increased as the cell size becomes smaller, as expected. The minimum pressure drop is obtained in the porosity 0.94 at a fixed cell size. A new correlation of the pressure drop is proposed based on the permeability and Ergun's coefficient for the aluminum foam metal.

  • PDF

절연용 통기완충 시트와 폴리우레탄 도막 방수재를 복합 적층한 탈기 시스템에 관한 연구 (A Study on the Air-Vent System of Complex Layer Applied Poly-Urethane Waterproofing Material and Air-Permeability Buffer Sheet)

  • 오상근;박봉규;고장렬;박윤철;김수련
    • 한국건축시공학회지
    • /
    • 제2권1호
    • /
    • pp.139-146
    • /
    • 2002
  • This study deals with the characterizing and the application like as insulation materials in the joint part in concrete surface layer and waterproofing sheet especially for roof slabs. Using steel materials and butil-rubber tape to band waterproofing sheet and concrete surface together before this waterproofing system will be applied. It can be expected to both the curability and the watertightness by coating poly-urethane 2 or 3 times with sheet surface. Therefore this waterproofing system can be possible to protect water without the damage when vapor is going out from concrete and without air pockets because of the difference temperature inside and out. This system particularly consists of air bents and elastic waterproofing sheet considering the physical damage while water can cause purely physical damage. This system is one of the most efficient ways of waterproofing system without air pocket.

남성용 정장의 온열특성 연구 (Thermal Characteristics of Men's Suit Ensembles)

  • 송민규;전병익
    • 한국의류산업학회지
    • /
    • 제1권3호
    • /
    • pp.264-274
    • /
    • 1999
  • 최근에 사용되고 있는 남성용 정장 중, 여름용 30종, 겨울용 30종 등 총 60종을 시료로 하여 이들의 온열특성 중 보온성(무풍시=0.2 m/sec 이하, 풍속시=1.2 m/sec)과 이와 관련된 물성, 즉 공기투과도, 무게, 두께 등을 측정 및 분석하여 앙상블 및 가먼트의 보온성을 예측하는 회귀식을 개발하였다. 그 결과로는 일반적인 남성용 정장의 물성으로 두께 및 무게는 겨울용이 높았으며, 여름용과 겨울용을 확실히 구별할 수 있는 인지는 공기투과도였는데 여름용의 공기투과도는 겨울용보다 약 3~6배 정도 높았다. 남성용정장의 온열특성을 보면 겨울용 정장의 보온성이 여름용보다 높았고, 풍속이 있을 때 앙상블의 보온성은 최대 30% 정도 감소하는 경향을 나타내었다. 또한, 정장상하의 물성을 독립변수로 하여 가먼트 및 앙상블의 보온성을 추정하는 회귀식을 개발하였는데, 회귀식분석결과, 정장앙상블의 보온성에 영향을 주는 인자는 두께, 무게, 및 사이즈로 나타났다.

  • PDF

종이 물성에 따른 판형 전열교환기의 성능 (Performance of a Plate-Type Enthalpy Exchanger Made of Papers Having Different Properties)

  • 김내현;조진표;송길섭;김동훈
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.547-555
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Papers having different properties were made from the same pulp by calendering or refining. Enthalpy exchanger samples were made from the papers, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were obtained, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that effective efficiency of latent heat transfer was approximately the same independent of the samples, which suggests that papers made of the same pulp show similar water vapor transmission characteristics independent of the degree of calendering or refining. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.