• 제목/요약/키워드: air-particle flow

검색결과 395건 처리시간 0.03초

매연입자 온도 측정에의한 확산화염의 매연생성 특성 해석 (Analysis of Soot Formation Characteristics in Diffusion Flames with Soot Particle Temperature Measurement)

  • 이원남;정용현
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.241-249
    • /
    • 1999
  • Soot particle temperatures in co-flow diffusion flames have been measured using a two-color pyrometry at the pressure of 0.2 MPa(2 atm). The measured soot particle temperatures along with the integrated soot volume fractions are analyzed to understand soot formation characteristics. At 0.2 MPa, the addition of small amount of air into ethylene do not change the soot particle temperature in soot formation regions. This result showed that the increase of soot formation with addition of air is mostly due to the chemical effect of the added air, such as the increased role of C3 chemistry during the early stage of soot inception process. The addition of sufficient air into ethylene, however, changes soot particle temperatures and the understanding of soot formation characteristics becomes complicated. Measured soot particle temperatures also showed that there is no significant temperature effect for the synergistic effect of ethylene/propane mixture on soot formation.

  • PDF

이류체 노즐을 이용한 FPD 세정시스템 및 공정 개발 (Optimization of FPD Cleaning System and Processing by Using a Two-Phase Flow Nozzle)

  • 김민수;김향란;김현태;박진구
    • 한국재료학회지
    • /
    • 제24권8호
    • /
    • pp.429-433
    • /
    • 2014
  • As the fabrication technology used in FPDs(flat-panel displays) advances, the size of these panels is increasing and the pattern size is decreasing to the um range. Accordingly, a cleaning process during the FPD fabrication process is becoming more important to prevent yield reductions. The purpose of this study is to develop a FPD cleaning system and a cleaning process using a two-phase flow. The FPD cleaning system consists of two parts, one being a cleaning part which includes a two-phase flow nozzle, and the other being a drying part which includes an air-knife and a halogen lamp. To evaluate the particle removal efficiency by means of two-phase flow cleaning, silica particles $1.5{\mu}m$ in size were contaminated onto a six-inch silicon wafer and a four-inch glass wafer. We conducted cleaning processes under various conditions, i.e., DI water and nitrogen gas at different pressures, using a two-phase-flow nozzle with a gap distance between the nozzle and the substrate. The drying efficiency was also tested using the air-knife with a change in the gap distance between the air-knife and the substrate to remove the DI water which remained on the substrate after the two-phase-flow cleaning process. We obtained high efficiency in terms of particle removal as well as good drying efficiency through the optimized conditions of the two-phase-flow cleaning and air-knife processes.

장방형 공간내 난류유동및 오염물질 거동의 수치해석 (A Numerical Analysis of Turbulent Flow Field and Contamination Particles Movements in Rectangular Chambers)

  • 심우섭;송기천;황태연;신영철
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.350-364
    • /
    • 1991
  • The movements of small particles distributed uniformly in a steady flow in rectangular chambers having inlets and outlets were simulated numerically. Low Reynolds number turbulent model with a two-equation ($k-{\varepsilon}$) which describes the turbulent characteristics was applied to predict the air flow pattern and particles movements under the condition of the various locations and size of ducts. The calculation results show that the prediction of recirculation zone and stagnation point of flow is important to determine the particles behavior according to the design change. These results will be useful in designing the rectangular chambers for collective protection.

  • PDF

수직 Rayleigh 유동내의 입자 거동 해석 (Analysis for Particle Motion of Vertical Rayleigh flow)

  • 고석보;전용두;이금배
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.755-760
    • /
    • 2006
  • The exhaust gas with solid particle goes through the riser in both particle circulating type and circulating fluidized bed type heat exchanger to recover the heat. During heat transfer, gas velocity in vertical riser decreases as viscosity of exhaust gas decreases. In this case, when the particle size is fixed, sometimes the exhaust gas happens to have lower velocity which prohibit them to go out of the riser. In this paper the particle motion in vertical Rayleigh flow was studied. The behavior of heat transfer was investigated by means of velocity and temperature distribution. The result from numerical analysis was validated by the experimental results. Fortran code was used to analyze the particle motion in vertical Rayleigh flow.

  • PDF

파울링 예측을 위한 가스-입자 이상 유동 해석(1)-고온 풍동 설계 및 성능실험- (Particulate Two-Phase Flow Analysis for Fouling Prediction(I)-Design of Hot Wind Tunnel and Its Performance Experiment-)

  • 하만영;이대래
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3695-3705
    • /
    • 1996
  • We designed the hot wind tunnel to reproduce the conditions of utility boiler and carried out its performance test, in order to investigate the particulate two-phase flow behaviour, the fouling and heat transfer characteristics to the heat exchanger. The hot wind tunnel introduces the control system to control the temperature in the test section. The particle is injected into the hot gas stream. The fouling probe (cylindrical tube) is positioned normal to the particulate gas-particle two-phase flow and cooled by the air. The temperature of gas and cooling air, and temperature in the fouling probe are measured as a function of time, giving the local and averaged heat transfer and fouling factor. The shape of particulate deposition adhered to the fouling probe is also observed.

가시화기법을 이용한 룸 에어컨 내부의 유동 구조에 관한 연구 (Study on Flow Structure inside Room Air Conditioner Using Visualization Technique)

  • 이수홍;라선욱;강근;고한서
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2713-2717
    • /
    • 2008
  • Whole flow fields of a room air conditioner (RAC) have been visualized by a Particle Image Velocimetry (PIV) technique to analyze the flow structure with various inlet and outlet angles, and to control an eccentric vortex which affects an efficiency and noise of the RAC. A test model with 5 stages of a cross flow fan has been manufactured and a transparent acryl has been installed at the side of the test model for the PIV experiment. The inlet and outlet flows and the flow inside the cross flow fan have been analyzed by varying the inlet grill angles and outlet blade angles. The movement of the eccentric vortex has been investigated experimentally by developing the measurement technique for the inner flow field of the cross flow fan. From the visualization of the inner flows, the origins of the noise inside the RAC and the condensation points around the outlet parts of the cold air have been observed and the solution of the problems can be proposed in this study.

  • PDF

2단 평행판 전기집진기의 방전부 특성 실험 (Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner)

  • 김익생;이재옥;김용진;최헌오
    • 설비공학논문집
    • /
    • 제5권1호
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

그래뉼 타입 활성탄 필터의 100 나노 미만 다분산 초미세먼지 표면흡착 제거 효율 연구 (Filtration Efficiency of Granular Activated Carbons to Polydisperse Ultrafine Particles through the Surface Adsoprtion)

  • 조경일;강기원;신지윤;김창혁
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.79-86
    • /
    • 2022
  • Many commercial air purifiers currently have deployed granular activated carbon (GAC) filters for removing volatile organic compounds in the indoor air. GACs are generally used to remove gaseous contaminants in the air through adsorption by the inner surfaces of pores. In addition, airborne particles can be also filtered by the surface adsorption of the GACs, which can improve the life-time of the particulate filters. In this study, the filtration efficiency of GACs to ultrafine particles through surface adsorption was investigated at different volume flow rates by deploying a continuous particle filtration system. The polydisperse sodium chloride (NaCl) particles were generated by a set of an atomizer and a diffusion dryer, and then mixed with particle-free air at different volume flow rates. The penetration of ultrafine particles and pressure drop for each experimental condition were measured to figure out the effect of the volume flow rate on the surface adsoprtion of the GACs to particles, ~ 2 mm. The particle filtration efficiency of the GACs decreased as the volume flow rate increased from 4 to 14 lpm. However, the 5 times thicker GAC filter layer decreased the penetration of ultraparticles than a preious study. The filtration efficiency of the single granule was also higher than the previous result in the literature with smaller granule filter materials.

튜브 전기로를 이용한 TiO2 나노입자의 합성 및 특성 분석 (Synthesis and Analysis of Nanosized TiO2 Particles Using a Tube Furnace)

  • 배귀남;현정은;이태규;정종수
    • 한국대기환경학회지
    • /
    • 제20권3호
    • /
    • pp.411-419
    • /
    • 2004
  • Titania particles are widely used as a photocatalyst to treat various contaminants in air and water. Titania particles were formed by vapor-phase oxidation of titanium tetraisopropoxide (TTIP) in a tube furnace between 773 and 1,273 K. The effect of process variables such as furnace temperature, flow rate of carrier air, and flow rate of sheath air on powder size and phase characteristics was investigated using a scanning mobility particle sizer (SMPS), transmission electron microscopy (TEM) and X-ray diffraction (XRD). The size distribution of synthesized titania particles was characterized with mode diameter and peak concentration. The mode diameter ranging from 20 to 80 nm decreased with increasing flow rates of sheath air and carrier air, and increased with increasing furnace temperature. The peak concentration increased with increasing flow rates of sheath air and carrier air The best synthetic condition for high production rate can be derived from the experimental data set represented by mode diameter and peak concentration. The crystal structure of synthesized titania particles was found to be anatase phase, ensuring high photocatalytic potential.

부산 도심지역 기습 폭우 후 형성된 도로면 토사의 재비산에 의한 미세먼지 농도 상승 (Concentration Rise of Fine Particle according to Resuspended Dust from Paved Roads after Sudden Heavy Rain in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제25권5호
    • /
    • pp.705-713
    • /
    • 2016
  • This study investigates the concentration sudden rise in fine particle according to resuspended dust from paved roads after sudden heavy rain in Busan on August 25, 2015. The localized torrential rainfall in Busan area occurred as tropical airmass flow from the south and polar airmass flow from north merged. Orographic effect of Mt. Geumjeong enforced rainfall and it amounted to maximum 80 mm/hr at Dongrae and Geumjeong region in Busan. This heavy rain induced flood and landslide in Busan and the nearby areas. The sudden heavy rain moved soil and gravel from mountainous region, which deposited on paved roads and near roadside. These matters on road suspended by an automobile transit, and increased fine particle concentration of air. In addition outdoor fine particle of high concentration flowed in indoor by shoes, cloths and air circulation.