• Title/Summary/Keyword: air-flow system

Search Result 2,495, Processing Time 0.026 seconds

A Study on Unsteady Flow measurement using Laser Doppler Velocimeter in Curved Duct (곡관에서 laser유속계를 이용한 비정상유동 계측에 대한 연구)

  • 조병기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.81-89
    • /
    • 1996
  • In the present study, the unsteady in a square-selctional 180.deg. curved duct are experimentally investigated. The experimental study using air in a square-sectional 180.deg. curved duct is carried out to measure axial velocity distributions with data acquisition and processing system. In this system, Rotating Machinery Resolver(RMR) and PHASE Software are used to obtain the results of unsteady flows. In conclusion, the exact measurement of unsteady flow using LDV system depends upon uniformity of metreials, duct thickness, and scattered particles.

  • PDF

Methodological Approaches to Reduce Uncertainties Associated with Air Sampling : Development and Assessment of a Six-port Manifold MFC System (대기 중 오염물질의 시료채취시 관측오차 저감방법에 대한 연구 : 6구형 매니폴더를 장착한 MFC system의 개발과 평가)

  • 김기현;오상인;최여진;김민영;최규훈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.377-386
    • /
    • 2003
  • In order to develop a confident sampling technique, we designed and constructed a 6-port manifold MFC sampling system for collecting gaseous pollutants in air. Using this instrumentation, we tested the performance criteria of MFC system in terms of: (1) flow rate; (2) MFC-to-MFC variability; (3) tube-to-tube variability; and (4) time. It was interesting to find that the later two factors did not show any significant variations, while the former two show substantially large variations. However, as most of those variabilities are consistent enough to form systematic patterns, we were able to explain the occurrence patterns of all those MFC biases in terms of those four major variables. The overall results of our experiment suggest that one needs to use correction factor for each MFC unit under a given flow rate to maintain optimal accuracy and precision for sampling of those pollutants.

A Study on the Urea-SCR System for NOx Reduction of a light-Duty Diesel Engine (소형 디젤엔진의 NOx 저감을 위한 Urea-SCR 시스템에 관한 연구)

  • Nam Jeong-Gil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.57-63
    • /
    • 2005
  • The effects of an urea injection at the exhaust pipe for a 4-cylinder DI(Direct Injection) diesel engine were investigated with the parameters such as urea-SCR(Selective Catalytic Reduction) and EGR system. The urea quantity was controlled by NOx quantity and MAF(Manifold Air Flow). The urea injection quantity can be controlled with the urea syringe pump, precisely. The effects of NOx reduction for the urea-SCR system were investigated with and without ECR engine, respectively. It was concluded that the SUF(Stoichiometric Urea Flow) is calculated and the NOx results are visualized with engine speed and load. Furthermore, the NOx map is made from this experimental results. It was suggested, therefore, that NOx reduction effects of the urea-SCR system without the EGR engine were better than that with the EGR engine except of low load and low speed.

A Study of Flow Characteristics through the Speed Control and Flow Resistance (유로저항에따른 속도제어를 통한 Zone별 유량특성 연구)

  • Oh, Byung-Kil;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.762-768
    • /
    • 2011
  • We use floor radiant heating system in the house of commons in winter Floor radiant heating system, which transfer heat by radiation, is one of the energy efficient and comfortable systems that. Floor radiant heating system is configured to be controlled by the room for energy-saving. Proper flow rate to a comfortable heating in the room is important. However, Using a constant speed circulation pump in separate rooms, heating system may cause an imbalance because of the difference of length of coil when operating in the rooms. In this study, our Research team examined heating imbalance due to the variation length through the coil length changes and flow control of the circulation pump.

Stabilization of Fuel F1ow in a Multi-Nozzle Combustion System Burning Natural Gas (천연가스 다노즐 열원설비의 연료 유동 안정화)

  • 박의철;차동진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1255-1265
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient flow in a utility gas turbine burning natural gas. The solution domain encompasses the supply gas pressure regulator to the combustor of the gas turbine that employs multi-nozzle fuel injectors. Some results produced for verification in the present study agree suite well with the experimental ones. It is found that the total gas flow may decrease noticeably during its combustion mode change, which would be the reason of momentary combustion upset, when a reference case of opening ratios of control valves in the system is applied. Several parameters are then varied in order to make the total gas flow stable over that period of time. Results of this study may be useful to understand the unsteady behavior of combustion system burning natural gas.

  • PDF

Development of Wireless Respiratory Air Flow and Urinary Flow Measurement System for Home Healthcare (가정용 무선 호흡기류 및 요속신호 계측 시스템 개발)

  • Cha, Eun-Jong;Lee, In-Kwang;Lee, You-Mi;Han, Soon-Wha;Han, Jeong-Su;Suh, Jae-Won;Park, Chan-Sik;Kim, Kyung-Ah
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1350-1357
    • /
    • 2012
  • Medical system for personal health management recently changes its paradigm from hospital service to self home care based on ubiquitous technology for healthcare anywhere at any time. The present study developed a wireless bio-signal measurement system for patients to self manage pulmonary disease and benign prostate hyperplasia(BPH), both of which are chronic diseases with increasing frequency in modern society. Velocity-type respiratory air flow transducer adapted to develop respiratory module for pulmonary disease management was simplified in structure to measure uni-directional flow since most important diagnostic parameters are evaluated on the expiratory flow signal only. Standard weight measurement technique was introduced to obtain urinary flow signal for BPH management. Three load cell signals were acquired for averaging to minimize noise, followed by accuracy evaluation. Transmission and receiver modules were also developed with user program for wireless communication. Averaged relative errors were 2.05 and 1.02% for respiratory volume and maximal flow rate, respectively, and the relative error was 2.17% for urinary volume, demonstrating that both modules enabled very accurate measurements. Wireless communication distance was verified within 15m, long enough for home care application. The present system allows the user to select a necessary measurement module on a particular health demand and to immediately provide the self-test results, thus better quality health care would be possible.

Performance Analysis of Refrigeration System Using the CFC-Alternative and Scroll Compressor (CFC-대체냉매와 스크롤압축기를 사용한 냉동시스템 성능해석)

  • Pak, H.Y.;Park, K.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.366-381
    • /
    • 1995
  • A performance analysis of refrigeration system using the HFC-134a and scroll compressor is performed numerically. The refrigeration system mainly consists of various standard components such as heat exchanger, compressor, and expansion device. The model for heat exchanger performance is based on a tube-by-tube method which is analyzed separately by considering the cross-flow heat transfer with the outdoor air flow and pressure drop. Compressor is used the scroll-type compressor which has many merits such as high efficiency, low noise and vibration, and small in size. Short-tube is included as an expansion device. Vapour and liquid line are also considered for the performance analysis of refrigeration system. Using the modeling of various components of refrigeration system, a performance comparison of CFC-12 and HFC-134a is performed numerically for the various outdoor air temperature and various values of short-tube diameter. As the results of this study, the refrigeration system performance decreases as the outdoor air temperature increases. And the optimum short-tube diameter based on COP is 1.37mm for this system.

  • PDF

A Study on the operation of Air Traffic Control System for a Korean Light Aircraft Carrier (한국형 경항공모함 항공관제장비 운영에 대한 연구)

  • Youn-chul Choi;Yong-tae Jung;Young-jin Cho;Do-hyun Kim;Won-hyuk Choi;Yoon-Su Park
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.2
    • /
    • pp.173-181
    • /
    • 2023
  • Aircraft carriers need to maintain an orderly flow of aircraft in order for military ships to conduct combat through aircraft. Maintaining aircraft flow is an important factor in strengthening ship and aviation safety. In order to maintain aircraft flow, it is essential to develop a state-of-the-art air control system that provides higher quality control information by simultaneously accommodating radar-based monitoring information and monitoring information based on CNS integrated technology. Based on this point, this study describes the function and operation method of specific control equipment for the operation of the Aviation Support System and Air Traffic Control System required to operate light aircraft carriers in Korea based on overseas cases.

Evaluation of Local Loss Coefficients for Different Waveguide-Below-Cutoff (WBC) Arrays of Electromagnetic Pulse (EMP) Shied in Buildings (도파관 배열에 의한 국부저항계수 산정)

  • Pang, Seung Ki;Chae, Young Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.7
    • /
    • pp.366-372
    • /
    • 2017
  • The objective of this study was to characterize Waveguide-Blow-Cutoff (WBC) array for Electromagnetic Pulse (EMP) shield in air duct or water pipe, the typical pathway of pulse in indoor space with critical electronic device. A numerical investigation with three different WBC designs (circular, rectangular, and hexagonal or honeycomb) was conducted to satisfy recommended shielding effectiveness (SE) levels from 80 dB to 140 dB. Pressure drop between upstream and downstream of EMP shields based on WBC arrays was also investigated to understand air flow feature in air duct of HVAC system. Results showed that honeycomb geometry outperformed other shapes in terms of reducing the depth of EMP shield, thus providing better air flow in duct path with lower local loss coefficient in HVAC system under SE requirements.

Velocity and Temperature Profiles of Steam-Air Mixture on the Film Condensation (막응축 열전달에서 공기-수증기 혼합기체의 속도 및 온도분포)

  • 강희찬;김무환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2675-2685
    • /
    • 1994
  • A study has been conducted to provide the experimental information for the velocity and temperature profiles of steam-air mixutre and to investigate their roles on the film condensation with wavy interface. Saturated gas mixture of steam-air was made to flow through the nearly horizontal$(4.1^{\circ})$ square duct of 0.1m width and 1.56m length at atmospheric pressure, and was condensated on the bottom cold plate. The air mass fraction in the gas mixture was changed from zero(W =0, pure steam) to one(W =1, pure air), and the bulk velocity was varied from 2 to 4 m/s. Water film was injected concurrently to investigate the effect of wavy interface on the condensation. The velocity and temperature profiles were measured by LDA system and thermocouples along the three parameters ; air mass fraction, mixture velocity and film flow rate. The profiles moved toward the interface with increasing steam mass fraction, mixture velocity and film flow rate. The Prandtl and Schmidt numbers were near one in the present experimental range, however there was no complete similarity between the velocity and temperature profiles of gas mixture. And the heat transfer characteristics and interfacial structure were coupled with each other.