• 제목/요약/키워드: air-duct cooling

검색결과 59건 처리시간 0.024초

정사각덕트의 코너부에서 이차유동 특성 (A Characteristics of a Secondary flow in a Corner Section of Square Duct)

  • 정정무;김지환;유영태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.753-758
    • /
    • 2000
  • Heat engine and fluid machinery in the plant have to linked with various ducts network and the corresponding design have to be concerned about effectiveness and stability of system of plant. To optimum control and design system concerning stability, economization, operating effectiveness we have to exact analysis flow properties of a duct applying to fluid machinery, heat exchanger, cooling machine, air conditioning equipment. therefore, it is necessary to research the duct, heat transfer equipment, for increasing overall effectiveness of air conditioning system by suggesting basic data of the duct resulting from organic research. So we can contribute to technical development of the duct. In case of speeding up the flow rate of the duct, lots of wave velocity components are occurred the value of boundary layer resulting from developing the boundary layer at both walls of duct.

  • PDF

에너지 절약용 냉방사이클 (Cooling Cycle for Energy Saving)

  • 이흥주;김용구
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.116-127
    • /
    • 1989
  • Research on reheating cooling cycle and its practical application have been made to prevent unequalized distribution of temperature and humidity of room due to lack of supply air volume and dewdrops on supply diffusers to be taken place as a result of lower temperature of supply air than that of dew point of room air in cooling cycle of constant air volume, single duct, single zone and draw-through fan type. In view of the fact that human body is insensitive to humidity, it is possible not only to construct the complete non-reheating cooling cycle by increasing the humidity point allowable with the deduction of occupant's sense of pleasantness minimizing, but also to get cooling cycle decreasing the reheating quantity if the humidity exceeds the point allowable. In addition, it is possible to save maximum 8% in electric energy for cooling in cooling system by constructing non-reheating cooling cycle instead of reheating cooling cycle and by increasing the relative humidity of room from 50% to 65% in case efficiency and air pressure of cooling system are low. It is also possible to get an optimum cooling cycle by determining the room humidity in consideration of pleasantness of occupants and conservation rate of electric energy if the cooling capacity, efficiency and total pressure of cooling equipment are fixed.

  • PDF

추진시스템 냉각유로의 주행풍 유동에 대한 수치해석적 연구 (Study on Numerical Analysis for Ram-Air flow of Cooling Duct on the Propulsion System)

  • 유성열;조정래;조태식;김철주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.507-513
    • /
    • 2009
  • The cooling technology of power conversion semiconductors in the propulsion system for the HEMU(High Electrical Multi Unit) are applied in water cooling method and phase change method such as the immersed type and the heat pipe type. Both of cooling systems need a condenser and a fan through forced wind to emit that is radiated heat from electric power conversion semiconductor(IGBT) stack effectively, now in the case of Japanese Fastec 360S, is using ram-air that is flowed in establishing cooling passage to propulsion system for cooling of condenser. In this research, it is that achieved the computing numerical analysis using ADINA of commertial program to examine flow characteristics and pressure distribution of ram-air for a condenser in cooling passage.

  • PDF

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF

초임계상태 이산화탄소의 정사각 단면 직덕트 내 난류유동 및 열전달의 전산해석 (Numerical Analysis of Turbulent Carbon Dioxide Flow and Heat Transfer under Supercritical State in a Straight Duct with a Square Cross-Section)

  • 최영돈;주광섭;김용찬;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1004-1013
    • /
    • 2002
  • Turbulent carbon dioxide flows and cooling heat transfers under supercritical state in a straight duct with a square cross-section are numerically analyzed employing low Reynolds number $\kappa-\varepsilon$ model and algebraic stress model. The flow is assumed to be (quasi-incompressible. Predicted Nusselt number and friction factor are compared with the experimental data, Blasius correlation for friction factor and Dittus-Boelter correlation for Nusselt number. Computational results for the Fanning's friction factor agree well with the all Rohsenow and Choi's correlation, Liou and Hwang's experimental data and Blasius correlation. The results obtained by algebraic stress model agree more with the Liou and Hwang's experimental data, while the results obtained by low Reynolds number $\kappa-\varepsilon$ model agree more with Blasius correlation. In the computation of Nusselt number, Dittus-Boelter correlation can not exactly fit the computational results. Therefore we propose the new correlation$Nu=0.053Re^{0.73}Pr^{0.4}$for the turbulent cooling heat transfer of carbon dioxide under supercritical state.

흡수식 공조 시스템의 동적 모델과 시뮬레이션 (Dynamic Models and Simulation of the Absorption Air Conditioning System)

  • 한도영;이승기
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.994-1003
    • /
    • 2000
  • Control algorithms for the absorption air conditioning system may be developed by suing dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help the development of effective control algorithms for the system. In this study, a dynamic simulation program for the absorption air conditioning system was developed. Dynamic models for an absorption chiller, a cooling tower, an air handling unit, a boiler, a three way valve, a controller, and a duct were developed and programed. Control algorithms for the absorption chiller, the cooling tower, and the air handling unit were selected, and analyzed to show the effectiveness of dynamic models. From the simulation results, it may be concluded that this simulation program may be effectively used for the development of optimal control algorithms of the absorption air conditioning system.

  • PDF

제너 다이오드를 이용한 공기 유속계측 장치개발

  • 김영재;김희식;조흥근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.496-500
    • /
    • 1996
  • An air flow measurement device is proposed. The thermal characteristic of a semiconductor element is adopted as a cooling parameter of thermal convection rate. The difference between forced convection and natural convection of two Zener diodes results enough difference in temperature. Experiment at various air flow conditions shows the measuring capability of the air flow in a duct. This measuring device has some merits, such as a reliability n hard field condition, simple circuit for signal processing, small volume of the element, less air flow resistance, independance of various ai temperature. The experimental result shows that it is an exact and usefull air flow measurement device.

  • PDF

토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석 (Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses)

  • 남상운;김영식
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.215-224
    • /
    • 2009
  • 공기유동 제어기술의 개발을 위한 기초자료를 제공 할 목적으로 토마토 재배 온실의 냉난방과 환기 및 공기유동 관련 실태를 조사하고, 온실유형과 난방방식별 온습도 분포를 실측하여 균일도를 분석하였다. 충남 부여 세도지역의 토마토 재배 온실 136농가를 대상으로 조사한 결과 대부분을 차지하는 단동 플라스틱 온실의 천창 설치 비율이 낮고 환기팬과 유동팬 설치비율도 매우 낮을 뿐만 아니라 설치제원도 편차가 매우 큰 것으로 나타났다. 아치형 단동 플라스틱온실의 천창 환기 구조의 개발보급과 연동곡부의 천창도 지붕상부로 이동시킬 필요가 있으며, 개별 천창구조 및 환기팬과 유동팬에 대한 설치 가이드라인의 제정이 요구된다. 냉방설비를 설치한 농가는 하나도 없었으며 난방방식의 대부분을 차지하는 온풍난방에서 덕트의 설치제원 역시 편차가 큰 것으로 나타났고, 온풍덕트의 배기풍속 및 배기온도 또한 거리에 따른 편차가 매우 큰 것으로 관측되었다. 수출경쟁력 화보를 위한 고품질의 생산물을 연중 안정적으로 생산하기 위해서는 온실냉방기술의 보급이 절실하며 난방방식이나 덕트설치 방식의 개선이 필요한 것으로 판단된다. 온실내 온습도 분포가 균일한지 여부를 판단하는 지표로 사용되고 있는 최대 편차와 실제 균등한 정도를 나타낼 수 있는 균일도와의 관계를 분석해 본 결과 높은 상관관계를 보였으나 주간에는 직선식으로 야간에는 2차 곡선식으로 다르게 표현되었다. 온습도 분포의 균일한 정도를 판정할 수 있는 객관적인 기준이 마련된다면 최대편차 대신 균일도를 지표로 사용하는 것이 더 합리적일 것으로 판단된다. 온실유형과 난방방식에 따라 온 습도분포의 균일도가 상당히 다른 것을 확인할 수 있었으며 야간에는 온수난방의 경우 이랑배관으로, 온풍난방의 경우 온풍덕트의 적절한 배치를 통하여, 주간에는 환기와 공기유동을 통하여 균일도를 개선할 수 있을 것으로 판단되었다.

일체형 주상용 몰드 변압기의 덕트에 따른 열해석 특성 연구 (The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition)

  • 조한구;이운용;박영두
    • 한국전기전자재료학회논문지
    • /
    • 제17권3호
    • /
    • pp.348-352
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and ow loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구 (The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition)

  • 조한구;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF