• Title/Summary/Keyword: air-bridge

Search Result 177, Processing Time 0.116 seconds

Damage detection of a cable-stayed bridge based on the variation of stay cable forces eliminating environmental temperature effects

  • Chen, Chien-Chou;Wu, Wen-Hwa;Liu, Chun-Yan;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.859-880
    • /
    • 2016
  • This study aims to establish an effective methodology for the detection of instant damages occurred in cable-stayed bridges with the measurements of cable vibration and structural temperatures. A transfer coefficient for the daily temperature variation and another for the long-term temperature variation are firstly determined to eliminate the environmental temperature effects from the cable force variation. Several thresholds corresponding to different levels of exceedance probability are then obtained to decide four upper criteria and four lower criteria for damage detection. With these criteria, the monitoring data for three stay cables of Ai-Lan Bridge are analyzed and compared to verify the proposed damage detection methodology. The simulated results to consider various damage scenarios unambiguously indicate that the damages with cable force changes larger than ${\pm}1%$ can be confidently detected. As for the required time to detect damage, it is found that the cases with ${\pm}2%$ of cable force change can be discovered in no more than 6 hours and those with ${\pm}1.5%$ of cable force change can be identified in at most 9 hours. This methodology is also investigated for more lightly monitored cases where only the air temperature measurement is available. Under such circumstances, the damages with cable force changes larger than ${\pm}1.5%$ can be detected within 12 hours. Even though not exhaustively reflecting the environmental temperature effects on the cable force variation, both the effective temperature and the air temperature can be considered as valid indices to eliminate these effects at high and low monitoring costs.

A study on the solution suggesting and the problem investigating of spatial designing through the axis of circulation in the extension of general hospital - A case study : medical college's hospital of Hanyang University - (종합병원의 증축과정에서 동선 중심축 형성을 통한 공간디자인의 문제점 도출과 해결안 제시에 관한 연구 -한양대학교 의과대학 부속병원의 사례-)

  • Kim, Kyu Sung;Lee, Jung Man
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2003
  • Contemporary hospital has more and more extension because the growth and change of hospital has to respond the various needs. For expanding, the sky bridge(sky walk) becomes one of the method to interconnect two or more buildings on the air. Sometimes the designers don't know exactly how the sky bridge works after construction. Beyond the role of interconnecting two buildings, the role of sky bridge is transformed the main axis of pedestrian in the whole hospital organization. This scope of analysis is about the sky bridge of Hanyang University hospital. The first method is the investigation of the utilization in this time. The second is the analysis of design drawings got form the designing of the past(1994-1998). From this analysis, the conclusions are followings.;The designer who wants to apply the sky bridge should more consider about, 1) how the sky bridge impacts the whole spatial system such as the pedestrian, patients, physicians, service's facilities etc. 2) what the inside of sky bridge has something such as natural light, ventilation, and the height, depth, width of aisle, the sign for seeking orientation. etc. In future the research relating sky bridge should be studied some hospital as well as one hospital for comparing the characteristics of the concepts and organizations

  • PDF

Cracking Behavior of Concrete Bridge Deck Due to Differential Drying Shrinkage (교량 바닥판 콘크리트의 부등건조수축 균열특성에 관한 연구)

  • Yang, Joo Kyoung;Lee, Yun;Yang, Eun Ik;Park, Hae Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.329-335
    • /
    • 2009
  • The purpose of this study is to provide the efficient method and guideline of controlling the cracking in bridge deck concrete due to differential drying shrinkage. Drying shrinkage cracking is mainly influenced by the moisture diffusion coefficient that determines moisture diffusion rate inside concrete structures. In addition to the diffusion coefficient, surface coefficient of concrete surface and relative humidity of ambient air simultaneously affect the moisture evaporation from concrete inside to external air outside. Within the framework of cracking shrinkage cracking mechanism, it is necessary to conceive the numerical analysis, which involves these three influencing factors to predict and control the shrinkage cracking of concrete. In this study, moisture diffusion and stress analysis corresponding to drying shrinkage on bridge deck are performed with consideration of diffusion coefficient, surface coefficient, and relative humidity of ambient air. From the numerical results, it is found that cracking behavior due to differential drying shrinkage of bridge deck concrete shows different feature according to three influencing factors and the methodology of controlling of drying shrinkage cracks can be suggested from this study.

Failure Modeling of Bridge Components Subjected to Blast Loading Part I: Strain Rate-Dependent Damage Model for Concrete

  • Wei, Jun;Quintero, Russ;Galati, Nestore;Nanni, Antonio
    • International Journal of Concrete Structures and Materials
    • /
    • v.1 no.1
    • /
    • pp.19-28
    • /
    • 2007
  • A dynamic constitutive damage model for reinforced concrete (RC) structures and formulations of blast loading for contact or near-contact charges are considered and adapted from literatures. The model and the formulations are applied to the input parameters needed in commercial finite element method (FEM) codes which is validated by the laboratory blast tests of RC slabs from literature. The results indicate that the dynamic constitutive damage model based on the damage mechanics and the blast loading formulations work well. The framework on the dynamic constitutive damage model and the blast loading equations can therefore be used for the simulation of failure of bridge components in engineering applications.

Seismic response prediction and modeling considerations for curved and skewed concrete box-girder bridges

  • Ramanathan, Karthik;Jeon, Jong-Su;Zakeri, Behzad;DesRoches, Reginald;Padgett, Jamie E.
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1153-1179
    • /
    • 2015
  • This paper focuses on presenting modeling considerations and insight into the performance of typical straight, curved, and skewed box-girder bridges in California which form the bulk of the bridge inventory in the state. Three case study bridges are chosen: Meloland Road Overpass, Northwest Connector of Interstate 10/215 Interchange, and Painter Street Overpass, having straight, curved, and skewed superstructures, respectively. The efficacy of nonlinear dynamic analysis is established by comparing the response from analytical models to the recorded strong motion data. Finally insights are provided on the component behavioral characteristics and shift in vulnerability for each of the bridge types considered.

Development of Wireless Power Transfer Coils for Loosely Coupled Dual-Active-Bridge Converter (Loosely Coupled Dual Active Bridge Converter 용 무선 전력 전송 코일 개발)

  • Lee, Jaehong;Lee, Seung-Hwan;Kim, Sungmin;Han, Dongyeop;Kim, Myung-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.31-33
    • /
    • 2019
  • 본 논문에서는 고주파 변압기 대신 무선 전력 전송 시스템을 적용해 양방향 전력 전송을 가능케 해주는 loosely coupled dual-active-bridge 컨버터에서, 코일 간 전송 효율을 높이기 위한 코일 형상 설계에 관한 연구를 진행하였다. 유한 요소법을 통해 여러 형태의 페라이트 코어에 대해 해석했다. 페라이트 코어 형태가 I-자 일 때 가장 높은 quality factor의 코일을 얻을 수 있었다. 또한, I-core의 ferrite plate의 크기에 따라 무선 전력 전송의 효율을 결정하는 코일의 coupling coefficient와 코일의 quality factor가 변하고 trade-off 관계가 있음을 확인하였다. 3cm의 air-gap에 대해 최대 효율을 가지는 코일 형상을 설계하여 시뮬레이션을 통해 97.8%의 코일간 전송효율을 얻었다.

  • PDF

Integrated Magnetic Transformer for ZVS Phase Shift Full Bridge Converter

  • Li, Xin-Lan;Shin, Yong-Hwan;Won, Jae-Sun;Kim, Jong-Sun;Shin, Hwi-Beom
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.119-126
    • /
    • 2010
  • An integrated magnetic (IM) transformer is proposed for a phase shifted full bridge (PSFB) converter with zero voltage switching (ZVS). In a proposed IM transformer, the transformer is located on the center leg of E-core and the output inductor is wound on two outer legs with air gap. The proposed IM transformer is analyzed by using the magnetic capacitor model. For reducing the core size, EE core is redesigned. The proposed IM transformer is experimentally verified on a 1.2 kW prototype converter. The converter efficiency with the proposed IM transformer is about 93 % at full load and its volume size can be reduced. It can be expected that the power density can be largely increased with the proposed IM transformer.

Visualization of Micro-Scale Plasma Generated in a Semiconductor Bridge (SCB) (반도체브리지로부터 발생되는 마이크로 플라스마 가시화)

  • Kim Jong-Uk;Park Chong-Ook;Kim Sun-Hwan;Lee Jung-Bok
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.53-54
    • /
    • 2002
  • Plasma ignition method has been applied in various fields particularly to the rocket propulsion, pyrotechnics, explosives, and to the automotive air-bag system. Ignition method for those applications should be safe and also operate reliably in hostile environments such as; electromagnetic noise, drift voltage, electrostatic background and so on. In the present study, a semiconductor bridge (SCB) plasma ignition device was fabricated and its plasma characteristics including the propagation speed of the plasma, plasma size, and plasma temperature were investigated with the aid of the visualization of micro scale plasma $(i.e.,\;\leq\;350\;{\mu}m)$, which generated from a Micro-Electro-Mechanical poly-silicon semiconductor bridge (SCB).

  • PDF

A Study on the optimal length of air cavity for Solar heat removal with Air-Vent System (일사열 배제를 위한 통기벽체 적정 길이에 대한 검토)

  • Kim, Sang-Jin;Kum, Jong-Soo;Choi, Kwang-Hwan;Shin, Byong-Hwan;Chung, Yong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.33-38
    • /
    • 2004
  • Outside wall systems we lost much energy from the dew of thermal bridge and unsuitable adiabatic construction. The air vent wall system can make reduce cooling loads from the outside wall in summer. The basic concept is connected with buoyant force by the difference of density. An external surface of a wall absorbs solar radiation, and transfers it to the air in the cavity. The warmed air gets buoyant force. So the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable. The purpose of this study is finding optimal length of air cavity by numerical analyses.

Evaluation of Concrete Bridge Deck Deterioration Using Ground Penetrating Radar Based on an Extended Common Mid-Point Method (확장형 공통중간점법 기반 지표투과레이더를 이용한 콘크리트 교량 바닥판 열화 상태 평가)

  • Baek, Jong Eun;Lee, Hyun Jong;Oh, Kwang Chin;Eom, Byung Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.82-92
    • /
    • 2012
  • This study proposed a new non-destructive evaluation method for concrete bridge deck deterioration using ground penetrating radar (GPR). To calculate dielectric constant of the concrete bridge deck, an extended common mid-point (XCMP) method was developed for a two-layered structure using an air-coupled GPR antenna setup. The deterioration conditions of the concrete bridge deck such as deterioration depth was evaluated based on the dielectric constant and surface-to-average dielectric constant ratio of the concrete bridge deck. A GPR field test was conducted on an old concrete bridge with asphalt concrete surfacing to validate the new evaluation method. The test results showed that the newly proposed method estimated pavement thickness and deterioration depth of the concrete deck in a reasonable level.