• Title/Summary/Keyword: air void

Search Result 263, Processing Time 0.028 seconds

A Prediction of the Air-lift Pump Performance by gas-liquid Flow Charac teristics of Riser (Riser의 기액유동 특성에 따른 Air-lift 펌프의 성능예측)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.252-258
    • /
    • 1999
  • As an effective means to convey crushed materials from seabed to on board ship and to raise hazardous or abrasive liquids air-lift pump provides a reliable mechanism due to its simple config-uration and easy-to-operate principle. The present study is focused on fundamental investigation of related performance by the analysis program based on the gas-liquid two-phase flow in circular pipes. The program covers pump operating in isothermal and vertical two-phase flow with Newto-nian liquids. it is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates and furthermore attachment of downcomer gives little effects on riser performance the conveyed liquid flow rate increases with larger submergence rate.

  • PDF

Evaluation of Physical and Mechanical Properties based on Liquid Composite Molding (액상성형공정별 물리적/기계적 특성 비교 평가)

  • Park, Dong-Cheol;Kim, Tai-Gon;Kim, Seung-Hyeok;Shin, Do-Hoon;Kim, Hyeon-Woo;Han, Joong-won
    • Composites Research
    • /
    • v.31 no.6
    • /
    • pp.304-310
    • /
    • 2018
  • Autoclave process has been remaining as one of the most robust and stable process in fabricating structural composite part of aerospace industry. It has lots of advantages, however exhibits some disadvantages or limitations in capital investment and operation. Recently, there have been various Out-of-Autoclave process being researched and developed to overcome those limitations. In this study, laminate specimens were fabricated using LCM (Liquid Composite Molding) process, regarded as one of potential OoA process. DB (Double bagging), CAPRI (Controlled Atmospheric Pressure Resin Infusion), VAP (Vacuum Assisted Process) and Autoclave process were used for laminate specimens. Void content, Thickness, Tg (Glass Transition Temperature), ILSS (Interlaminar Shear Strength) and Flexural strength properties were evaluated for comparison. It is verified that Autoclave based specimen has uniform thickness distribution, the lowest void content and outstanding mechanical properties. And, CAPRI based specimen exhibits relatively good physical and mechanical properties over DB and VAP based specimen and comparable mechanical properties with autoclave based specimen.

An Experimental Study on the Properties of Porous Concrete according to the Mix Factors and Compaction Load (배합조건 및 다짐하중에 따른 포러스 콘크리트의 특성에 관한 실험적 연구)

  • Lim, Seo-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.83-91
    • /
    • 2015
  • Porous concrete consists of cement, water and coarse aggregate and has been used for the purpose of decreasing the earth environmental load such as air and water permeability, sound absorption, etc. However, the physical and mechanical properties of porous concrete changes due to compaction load during construction. For such a reason, the purpose of this study is to investigate the physical and mechanical properties of porous concrete according to the kinds of binder, the ratio of water to binder and target void ratio. In particular, this study has been carried out to investigate the influence of compaction load on the void ratio, strength and coefficient of permeability. Aggregate used in this study are by-products generated during production of crushed gravel with a maximum size of 13mm. The results of this study showed that the target void ratio, the coefficient of permeability and compressive strength of porous concrete had a close relationship with the void ratio, and it will be possible that the void ratio is suggested by the mix design of porous concrete. The compressive strength of porous concrete was the highest at the content of the expansive admixture of 5% and compared to non-mixture, 10% mixture of silica fume improved compressive strength about 32%. And in the result of the study to change the compaction load, the compressive strength increased from the load of 15kN, the void ratio decreased from the load of 0.8kN, the coefficient of permeability decreased from the load 35kN, respectively.

Experimental study on flow pattern transitions for inclined two-phase flow (경사각 이상유동양식 천이에 관한 실험적 연구)

  • Kwak, Nam-Yee;Kim, Man-Woong;Lee, Jae-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3021-3026
    • /
    • 2007
  • In this paper, experimental data on flow pattern transition of inclination angles from 0-90 are presented. A test section is constructed 2 mm long and I.D 1inch using transparent material. The test section is supported by aluminum frame that can be placed with any arbitrary inclined angles. The air-water two-phase flow is observed at room temperature and atmospheric condition using both high speed camera and void impedance meter. The signal is sampled with sampling rate 1kHz and is analyzed under fully-developed condition. Based on experimental data, flow pattern maps are made for various inclination angles. As increasing the inclination angels from 0 to 90, the flow pattern transitions on the plane jg-jf are changed, such as stratified flow to plug flow or slug flow or plug flow to bubbly flow. The transition lines between pattern regimes are moved or sometimes disappeared due to its inclined angle.

  • PDF

A Study On Void Check for Top-Down Column Joint by Field Experiment (현장실험을 통한 역타설 이음부의 공극특성 분석)

  • Lee, Young-Do;Jung, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.1 s.15
    • /
    • pp.105-109
    • /
    • 2005
  • Classified with concrete as placing ways - direct ways, sheath way - and placing directing flange direction, web direction - is analyzed section and strength of hardened concrete. The results of this study is belows the more fluid of concrete, the more useful to top-down method. To minimize the voids of the reverse placement joints, It is more effect to use the sheath method than direct method in concrete placement. If the joint face is a plane, it is impossible to extract the air bubbles which caused voids, so we should consider about this, and decide to select which type of joints.

An Experimental Study on the Evaluation of Porous Concrete using Industrial By-products of Planting Factory (산업부산물을 이용한 포러스콘크리트의 식생능력평가에 관한 연구)

  • 박승범;권혁준;서대석;윤덕열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.779-784
    • /
    • 2002
  • Porous concrete with a great deal of continuous porosity enables to contain water and to pass air freely through firmly hardened material, and allow necessary nutrients to reach roots of vegetation. Therefore, this paper deals with the voluntary properties and efficiency for planting of plant porous concrete. The results of experiment showed that void volumes were 17% to 31%, and compressive strength ranged between 80kgf/cm$^2$ and 180kgf/cm$^2$ when the ratio of the paste to aggregate was 0.3-0.5 When the aggregate size are 20-30mm, the paste to aggregate ratio is 0.3, and the length of Paranial Ryegress came up as 32cm. Ut supra the efficiency of planting goes through Paranial Ryegrass in result the length of plant are in compliance with void volume and aggregate size.

  • PDF

A Study on the Sea-water Purification Properties of Porous Concrete (포러스콘크리트의 해수정화특성에 관한 실험적 연구)

  • Seo, Dae-Seuk;Park, Seong-Bum;Lee, Jun;Song, Jae-Lib;Kim, Jung-Hee
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.649-652
    • /
    • 2006
  • This paper describe the performance of seawater purification, to which living organisms can adapt, and the physical properties of porous concrete with continuous void. Although conventional concrete has been regarded as a destroyer of nature, seawater and air can pass freely through concrete when it is made porous by forming continuous void. This not only enables plants to vegetables, but also makes it possible for microscopic animals and plants, including bacteria, to attach to and inhabit uneven surface as well as internal voids when the concrete is provided in a natural seawater area or seawater side area. As a result, porous concrete using recycled aggregate improved the performance of seawater purification. In this study, The performance of seawater purification of porous concrete using recycled aggregate analyzed by T-P, T-N.

  • PDF

A Numerical Study on the Two-Phase Natural Circulation Flow in Reactor Cavity under External Vessel Cooling (원자로 외벽냉각시 원자로공동에서의 자연순환 이상유동에 대한 수치적 연구)

  • Kim, Hong-Min;Seo, Jun-Woo;Kim, Kwang-Yong;Park, Rae-Joon;Ha, Kwang-Soon;Kim, Sang-Baik
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.781-785
    • /
    • 2003
  • This work presents a numerical analysis of two-phase natural circulation flow in reactor cavity under external vessel cooling. Steady, incompressible, three-dimensional Reynolds-averaged Navier-Stokes equations for multiphase flows with zero equation turbulence model are solved to predict the shear key effect on the circulation rate of cooling water and the distribution of void fraction according to the different mass flow of inlet air. Results show that shear key has a positive effect on the circulation rate of cooling water and induce a local increase of void fraction below the shear key, but not remarkably.

  • PDF

Two-Phase Flow Characteristics in an Adiabatic Horizontal Tube (단열 수평관내 이상류의 유동특성)

  • Choi, B.H.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.36-40
    • /
    • 2004
  • Two-phase loop systems using the latent heat capacity of their working fluids can meet the increasing power requirements and are well suited to thermal management systems of future large applications, due to its abilities to handle large heat loads and to provide them at uniform temperatures regardless of the changes in the heat loads. Therefore some experiments on the effect of the gas and liquid superficial velocities, $j_G,\;j_L$ on flow pattern transition, void fraction and frictional pressure loss were performed on a co-current air-water flow in an adiabatic horizontal tube. The flow patterns were depended on the superficial velocity of each phase. It snowed that the increasing $j_L$, resulted in a significant increase in the frictional pressure loss for all flow patterns, at a constant $j_G$. The experimental results were also evaluated with some of existing models and correlations.

  • PDF

Vibration Characteristics of Heat Exchanger Tube Bundles in Two-Phase Cross-Flow (2상 횡유동을 받는 열교환기 관군의 진동특성)

  • 김범식;박태철
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.199-208
    • /
    • 1994
  • Two-phase cross-flow exists in many shell-tube heat exchangers such as nuclear steam generators, condensers and reboilers. An understanding of damping and of flow-induced vibration excitation mechanisms in necessary to avoid problems due to excessive tube vibration. In this paper, we present the results of experiments on normal-triangular tube bundles of pitch to tube diameter ratio, p/d, 1.22, 1.32 and 1.47. The bundle were subjected to air-water mixtures to simulate realistic mass fluxes and vapour qualities corresponding to void fractions from 5 to 99%. Damping, fluidelastic instability and turbulence- induced excitation are discussed. The behaivior of damping and two vibration mechanisms are different for intermittent flows from for bubbly flows. The effect of pitch to tube diameter ratio and void fraction is dominant on damping and fluidelastic instability.

  • PDF