• 제목/요약/키워드: air velocity measurement

검색결과 261건 처리시간 0.028초

곡관에서 laser유속계를 이용한 비정상유동 계측에 대한 연구 (A Study on Unsteady Flow measurement using Laser Doppler Velocimeter in Curved Duct)

  • 조병기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권4호
    • /
    • pp.81-89
    • /
    • 1996
  • In the present study, the unsteady in a square-selctional 180.deg. curved duct are experimentally investigated. The experimental study using air in a square-sectional 180.deg. curved duct is carried out to measure axial velocity distributions with data acquisition and processing system. In this system, Rotating Machinery Resolver(RMR) and PHASE Software are used to obtain the results of unsteady flows. In conclusion, the exact measurement of unsteady flow using LDV system depends upon uniformity of metreials, duct thickness, and scattered particles.

  • PDF

슬라이더의 동적거동에 대한 실험적 고찰(DFHT를 이용한 슬라이더의 동적거동 측정 방법) (Experimental study of dynamic response of a slider(A Measurement of Slider Dynamic Using DFHT))

  • 강태식;김재원;박노열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1117-1121
    • /
    • 2001
  • The dynamic behavior of slider is investigated using Dynamic Flying Height Tester(DFHT). The dependence of slider's dynamic fluctuation on disk velocity is measured, and a comparison is made with the computational result.

  • PDF

정지공기중 점성유체 분류의 분열길이 측정 (Measurement of Breakup Length of Viscous Liquid Jet in Stagnant Air)

  • 임정현;류근영;임성빈;노수영
    • 한국분무공학회지
    • /
    • 제3권4호
    • /
    • pp.1-7
    • /
    • 1998
  • The measurement of breakup length of viscous liquid jet in stagnant air was conducted by a 3CCD digital video camera. The nozzle diameters of 4, 6, 8mm with L/d=50 were selected and the dynamic viscosity of viscous liquid made of glycerine and water was in the range of $1.061\times10^{-6}m^2/s$ to $4.935\times10^{-5}m^2/s$. The critical velocity is decreased and the breakup length is increased with the increase of nozzle diameter at the same dynamic viscosity of liquid. At the same nozzle diameter, the breakup length and the critical velocity are both increased with the increase of dynamic viscosity of liquid. It is found in the theoretical analysis that the initial disturbance level is the main cause of occurrance of critical Reynolds number in the stability curve. The comparison of experimental critical Reynolds number and the empirical correlation by Tanasawa and Toyota reveals the relatively good agreement.

  • PDF

다점 피토관을 이용한 기체 유량 측정의 불확도 평가 (Uncertainty Assessment of Gas Flow Measurement Using Multi-Point Pitot Tubes)

  • 양인영;이보화
    • 한국유체기계학회 논문집
    • /
    • 제19권2호
    • /
    • pp.5-10
    • /
    • 2016
  • Gas flow measurement in a closed duct was performed using multi-point Pitot tubes. Measurement uncertainty was assessed for this measurement method. The method was applied for the measurement of air flow into a gas turbine engine in an altitude engine test facility. 46 Pitot tubes, 15 total temperature Kiel probes and 9 static pressure tabs were installed in the engine inlet duct of inner diameter of 264 mm. Five tests were done in an airflow range of 2~10 kg/s. The flow was compressible and the Reynolds numbers were between 450,000 and 2,220,000. The measurement uncertainty was the highest as 6.1% for the lowest flow rate, and lowest as 0.8% for the highest flow rate. This is because the difference between the total and static pressures, which is also related to the flow velocity, becomes almost zero for low flow rate cases. It was found that this measurement method can be used only when the flow velocity is relatively high, e.g., 50 m/s. Static pressure was the most influencing parameter on the flow rate measurement uncertainty. Temperature measurement uncertainty was not very important. Measurement of boundary layer was found to be important for this type of flow rate measurement method. But measurement of flow non-uniformity was not very important provided that the non-uniformity has random behavior in the duct.

평판 핀 튜브 열교환기의 공기측 강제대류 열전달계수에 대한 실험 및 수치계산 (Experimental Measurement and Numerical Computation on the Air-Side Forced Convective Heat Tranfer Coefficient in Plate Fin-Tube Exchangers)

  • 윤영환;팽진기;윤건식
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.729-737
    • /
    • 2006
  • Air-side forced convective heat transfer of a plate fin-tube heat exchanger is investigated by experimental measurement and numerical computation. The heat exchanger consists of staggered arrangement of refrigerant pipes of 10.2 m diameter and the pitch of fins is 3.5 m. In the experimental study, the forced convective heat transfer is measured at Reynolds number of 1082, 1397, 1486, 1591 and 1649 based on diameter of refrigerant piping and mean velocity. Average Nusselt number for the convective heat transfer coefficient is also computed for the same Reynolds number by commercial software of STAR-CD with standard $k-{\varepsilon}$ turbulent model. It is found that the relative errors of average Nusselt numbers between experimental and numerical data are less than 6 percentage in Reynolds number of $1082{\sim}1649$. The errors between experiment and other correlations are ranged from 7% to 32.4%. But the correlation of Kim at al is closest to the experimental data within 7% of the relative error.

PIV기법에 의한 엇갈린 관군 배열 내부의 유동장 측정 (Measurement of Flow Field through a Staggered Tube Bundle using Particle Image Velocimetry)

  • 김경천;최득관;박재동
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.595-601
    • /
    • 2001
  • We applied PIV method to obtain instantaneous and ensemble averaged velocity fields from the first row to the fifth row of a staggered tube bundle. The Reynolds number based on the tube diameter and the maximum velocity was set to be 4,000. Remarkably different natures are observed in the developing bundle flow. Such differences are depicted in the mean recirculating bubble length and the vorticity distributions. The jet-like flow seems to be a dominant feature after the second row and usually skew. However, the ensemble averaged fields show symmetric profiles and the flow characteristics between the third and fourth measuring planes are not so different. comparison between the PIV data and the RANS simulation yields severe disagreement in spite of the same Reynolds number. It can be explained that the distinct jet-like unsteady motions are not to be accounted in th steady numerical analysis.

  • PDF

전기 집진기에서의 Submicron 입자의 집진 특성에 관한 연구-I. 전기적 특성 (A Study on the Collection Characteristics of Submicron Particles in an Electrostatic Precipitator - I. Electrical Characteristics)

  • 김용진;황태근;유주식
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.572-578
    • /
    • 2001
  • This study conducts a laboratory measurement on a cylindrical electrostatic precipitator(ESP) with a 30mm-diameter cylinder. Several kinds of test aerosols are generated with an atomizer and a diffusion dryer. The effects of applied voltage, flow state, gas velocity, and gas temperature on the electrical characteristics of the precipitator and onset of corona are experimentally investigated. The corona onset voltage is decreased, as diameter of discharge electrode wire becomes small or temperature of the precipitator increases. As the fluid velocity or particle load in the precipitator increases, the corona current is decreased.

  • PDF

PIV measurement of the flow field in rectangular tunnel

  • Park, Sang-Kyoo;Yang, Hei-Cheon;Lee, Yong-Ho;Chen, Gong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.886-892
    • /
    • 2008
  • The development of fluid mechanics is briefly reviewed and the importance of fluid flows to heat and mass transfer in nature as well as to science and engineering is outlined. This paper presents the experimental results of air flow in the rectangular tunnel which has four different exhaust outlets, each distance of which from the inlet is 0, 30, 60 and 90mm respectively. This experiment is conducted by using the olive oil as the tracer particles and the kinematic viscosity of the air flow is $1.51{\times}10^{-5}\;m^2$/s. The flow is tested at the flow rate of 1.3 $m^3$/h and the velocity of 0.3 m/s. PIV technology can be used to make a good description of the smoke flow characteristics in the tunnel.

열선유속계에 의한 디이젤기관 연소실내의 공기유동 측정 (Measurement of Air Motion in a Diesel Engine Combustion Chamber using Hot Wire Anemometer)

  • 우대성;고대권;안수길
    • 수산해양기술연구
    • /
    • 제23권2호
    • /
    • pp.86-94
    • /
    • 1987
  • 열선유속계를 이용하여 디이젤 기관 연소실내의 한점에서 유속을 측정한 결과는 다음과 같은 결론을 얻었다. 1. 연소실내의 유동은 cylinder의 원주방향의 속도 성분이 크며, 유속변화는 밸브 timing과 피스톤 속도등에 밀접한 관계가 있다. 2. 유속은 흡입시부터 증가하여 압축행정중 흡입밸브가 닫히는 60$^{\circ}$ABDC에서 최대치를 갖고 이후 피스톤의 속도가 감소함에 따라 유속도 감소하여 팽창행정중 배기 밸브가 열리는 120$^{\circ}$ATDC에서 다시 증가하였다. 3. 평균유속은 shroud 밸브 사용시가 no shroud 밸브 사용시보다 낮지만 shroud 밸브 사용시 흡입행정에서 난류강도가 가장 크게 나타났다. 4. 90$^{\circ}$shroud 밸브 사용시가 120$^{\circ}$shroud 밸브 사용시보다 난류강도는 더 크고, 90$^{\circ}$shroud의 180$^{\circ}$위치에서 난류강도가 제일 크게 나타났다.(이 논문의 결론부분임)

  • PDF

열선유속계에 의한 디이젤기관 연소실내의 공기유동 측정 (Measurement of Air Motion in a Diesel Engine Combustion Chamber using Hot Wire Anemometer )

  • 우대성;고대권;안수길
    • 수산해양기술연구
    • /
    • 제23권2호
    • /
    • pp.40-40
    • /
    • 1987
  • 열선유속계를 이용하여 디이젤 기관 연소실내의 한점에서 유속을 측정한 결과는 다음과 같은 결론을 얻었다. 1. 연소실내의 유동은 cylinder의 원주방향의 속도 성분이 크며, 유속변화는 밸브 timing과 피스톤 속도등에 밀접한 관계가 있다. 2. 유속은 흡입시부터 증가하여 압축행정중 흡입밸브가 닫히는 60°ABDC에서 최대치를 갖고 이후 피스톤의 속도가 감소함에 따라 유속도 감소하여 팽창행정중 배기 밸브가 열리는 120°ATDC에서 다시 증가하였다. 3. 평균유속은 shroud 밸브 사용시가 no shroud 밸브 사용시보다 낮지만 shroud 밸브 사용시 흡입행정에서 난류강도가 가장 크게 나타났다. 4. 90°shroud 밸브 사용시가 120°shroud 밸브 사용시보다 난류강도는 더 크고, 90°shroud의 180°위치에서 난류강도가 제일 크게 나타났다.(이 논문의 결론부분임)